RESUMEN
OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS: Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS: Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (Ë750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (Ë750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p Ë 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION: Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex Ë750 mm³.
Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/terapia , Diseño de PrótesisRESUMEN
BACKGROUND: Despite continuous improvements in transcatheter aortic valve implantation (TAVI), periprocedural strokes remain a devastating complication. Randomized controlled trials failed to demonstrate a reduction in clinically apparent strokes or mortality after TAVI due to cerebral embolic protection (CEP). To identify potential targets of CEP strategies during TAVI, we evaluated affected brain regions, and temporal patterns of stroke onset in a routine clinical sample. METHODS AND RESULTS: A total of 3,164 consecutive patients treated with TAVI from 2008 to 2019 at a single center were screened for cerebrovascular events. Affected cerebral regions were determined according to clinical symptoms and brain imaging. Rates of disabling stroke and non-disabling stroke at 30 days were 2.2% and 1.4%, respectively. The frequency of all strokes decreased from 5.0% to 3.0% over time (P = .012). Patients with impaired left-ventricular function (OR 2.19), increased CHA2DS2-VASc (OR 1.39) and moderate/severe spontaneous echo contrast (OR 3.60) had a higher stroke risk. Acute symptom onset occurred during TAVI (19.4%), within 24 hours (40.3%) or later (25.0%); 98.3% of strokes were of ischemic origin. In intraprocedural strokes, 53.2% of lesions were found in locations considered protected by current CEP devices, and 37.5% of patients with intraprocedural strokes were exclusively affected in these areas. Baseline or procedural parameters were not associated with embolic distribution patterns. CONCLUSIONS: Most strokes occurred early after TAVI - but not necessarily during the procedure - and affected multiple brain regions only partially protected by current CEP devices. Efficient prevention of cerebrovascular events may require strategies beyond the TAVI procedure to minimize stroke risk and additional randomized controlled trials will be required to clarify the role of CEP in efficient stroke prevention during TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Implantación de Prótesis de Válvulas Cardíacas , Embolia Intracraneal , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Encéfalo/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Embolia Intracraneal/epidemiología , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
AIM AND OBJECTIVE: We sought to investigate and compare outcomes 2 years after Hybrid-stenting with bioresorbable vascular scaffolds (BVS) and contemporary metallic drug-eluting stents (DES) within the same coronary lesion versus BVS alone. METHODS: Between 11/2012 and 7/2015 at our institution, 134 (33.2%) were treated with Hybrid-stenting for complex or long coronary lesions, 270 patients were treated by BVS alone. The primary outcome of interest was target lesion failure (TLF) at 2-years of follow-up. RESULTS: Patients treated by Hybrid-stenting were more frequently men (80% vs. 70%, p = 0.04) had extensive multivessel disease (84% vs. 71%, p < 0.01) including more complex (89% vs. 52%, p < 0.01) and longer lesions (28.9 mm vs 16.4 ± mm, p < 0.01) resulting in longer treated segments (47.3 mm vs 21.5 mm, p < 0.01) and more residual in-segment stenosis (12.3% vs 8.5%, p < 0.01) compared to BVS alone patients. At 2 years, cumulative incidence of TLF was 9.7% of Hybrid-stenting patients and 11.5% of BVS alone patients (p = 0.62), myocardial infarction (3.0% vs 4.1%, p = 0.59) and mortality (1.5% vs 4.1%, p = 0.17), respectively. Target lesion revascularization occurred in 9 Hybrid-stenting patients (2 located in DES) and in 20 BVS alone patients, cumulative incidence 6.7% vs. 7.4% (p = 0.80). Chronic kidney disease and residual in-segment stenosis >30% were identified as independent predictors of TLF at 2-years. CONCLUSION: Despite differences in clinical and angiographic profile, Hybrid-stenting performed similar to BVS alone at 2 years after percutaneous coronary intervention.
Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
The enteric nervous system has to adapt to altering dietary or environmental conditions and presents an enormous plasticity that is conserved over the whole lifespan. It harbours neural-crest-derived neurons, glial cells and their precursors. Based on a nestin-green fluorescent protein (NGFP) transgenic model, a histological inventory has been performed to deliver an overview of neuronal and glial markers for the various parts of the gastrointestinal tract in newborn (postnatal day 7) and adult mice under homeostatic conditions. Whereas NGFP-positive glial cells can be found in all parts of the gut at any individual age, a specific NGFP population is present with both neuronal morphology and marker expression in the myenteric plexus (nNGFP). These cells appear in variable quantities, depending on age and location. Their overall abundance decreases from newborn to adults and their spatial distribution is also age-dependent. In newborn gut, nNGFP cells are found in similar quantities throughout the gut, with a significantly lower presence in the duodenum. Their expression increases in the adult mouse from the stomach to the colon. All of these nNGFP cells expressed either (but not both) of the glia markers S100 or glial fibrillary acidic protein (GFAP). In the S100-positive glia population, a subset of cells also shows a neuronal morphology (nS100), without expressing nestin. Thus, the presence of premature neurons that express NGFP demonstrates that neurogenesis takes place far beyond birth. In enteric neurons, NGFP acts as a marker for neuronal plasticity showing the differentiation and change in the phenotype of neuronal precursor cells.
Asunto(s)
Proteínas Fluorescentes Verdes/metabolismo , Plexo Mientérico/metabolismo , Nestina/metabolismo , Proteínas Recombinantes de Fusión/metabolismo , Animales , Animales Recién Nacidos , Biomarcadores/metabolismo , Calbindina 2/metabolismo , Calbindinas/metabolismo , Comunicación Celular , Proliferación Celular , Forma de la Célula , Proteína Ácida Fibrilar de la Glía/metabolismo , Ratones , Ratones Endogámicos BALB C , Plexo Mientérico/citología , Neuroglía/citología , Neuroglía/metabolismo , Neuronas/citología , Neuronas/metabolismo , Óxido Nítrico Sintasa de Tipo I/metabolismo , Fenotipo , Proteínas S100/metabolismoRESUMEN
BACKGROUND: Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS: This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS: Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS: Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION: Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.
RESUMEN
(1) Background: Transfemoral transcatheter aortic valve implantation (TAVI) has become the standard treatment for most patients with severe symptomatic aortic stenosis. Intravascular lithotripsy may facilitate transfemoral TAVI (IVL-TAVI) even in patients with severely calcified iliofemoral disease. We assessed technical aspects and clinical outcomes of this novel approach compared to alternative transaxillary access (TAX-TAVI). (2) Methods: IVL-TAVI was performed for severe iliofemoral calcifications precluding standard transfemoral access in 30 patients from 2019 to 2022 at a single academic heart center. IVL was performed as part of the TAVI procedure in all cases. Results were compared to a control group of 44 TAX-TAVI procedures performed for the same indication from 2016 to 2021. The safety outcome was a composite of all-cause death, stroke, access-related bleeding ≥ type 2 within 24 h and major vascular access site complications at 30 days. The efficacy outcome was defined as a technical success according to VARC-3. (3) Results: Median age was 78.2 [74.3, 82.6] years, 45.9% were female and mean STS-PROM was 3.6% [2.3, 6.0]. Iliofemoral calcifications were more severe in the IVL-TAVI vs. TAX-TAVI groups (lesion length: 63.0 mm [48.6, 80.3] vs. 48.5 mm [33.1, 68.8]; p = 0.043, severe calcification at target lesion: 90.0% vs. 68.2%; p = 0.047, and median arc calcification 360.0° [297.5, 360.0] vs. 360.0° [180.0, 360.0]; p = 0.033). Technical success was achieved in 93.3% vs. 81.8% (p = 0.187) in IVL- and TAX-TAVI and the safety outcome occurred in 10.0% vs. 31.8% in IVL- and TAX-TAVI (p = 0.047), respectively. (4) Conclusions: IVL-assisted transfemoral TAVI was feasible and safe with favorable outcomes compared to TAX-TAVI. IVL may further expand the number of patients eligible for transfemoral TAVI and may help overcome limitations of an alternative access.
RESUMEN
BACKGROUND: Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). AIM: We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI. METHODS: A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed. RESULTS: In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT < CD (1-year mortality: ET ≥ vs. < CD: 15.01vs. 33.1%, AT ≥ vs < CD 16.3 vs. 26.5%, p < 0.001). Moreover, multivariable analysis identified ET ≥ CD (HR 0.61 [95% CI 0.43-0.87; p < 0.007]) to be associated with beneficial outcome after TAVI, independent from clinical risk factors and echocardiography-derived parameters. CONCLUSION: Among the studied hemodynamic parameters T-LVAo provides the highest diagnostic value, whereas ET is an outcome predictor beyond clinical risk factors and echocardiographic parameters in AS patients following TAVI. These parameters could be of considerable use in diagnostic evaluation and risk assessment of patients scheduled for TAVI. T-LVAo (yellow): defined as time between left ventricular and aortic systolic pressure peaks. ET (green): Ejection Time defined as time from the start to flow end. AT (orange): Acceleration time defined as time from the start to the peak flow. AOP: aortic pressure, AVC: aortic valve calcification, CI: confidence interval, HGAS: high-gradient aortic stenosis, LGAS: low-gradient aortic stenosis, LVP: left ventricular pressure, SD: standard deviation.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Hemodinámica , Función Ventricular Izquierda , Volumen Sistólico , Índice de Severidad de la EnfermedadRESUMEN
BACKGROUND: Beneficial results of transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) in patients at all risk strata have led to substantial changes in guideline recommendations for valvular heart disease. AIM: To examine influence of these guideline changes on a real-world TAVI cohort, we evaluated how risk profiles and outcomes of TAVI patients developed in our single-center patient cohort over a period of 12 years. METHODS: Baseline, procedural and 30-day outcome parameters of TAVI patients were retrospectively compared between three time periods (period 1: 2008-2012, period 2: 2013-2017, period 3: 2018-2020). RESULTS: Between 03/2008 and 12/2020, a total of 3678 patients underwent TAVI at our center. The median age was 81.1 years (25th, 75th percentile: 76.7, 84.9) with no significant change over time. The EuroSCORE II showed a continuous and significant decline from 5.3% (3.3, 8.6) in period 1 to 2.8% (1.7, 5.0) in period 3 (p < 0.001). Furthermore, rates of permanent pacemaker implantation, acute kidney injury, and paravalvular leakage ≥ moderate continuously declined over time. Accordingly, the 30-day mortality fell from 9.3% in period 1 to 4.3% in period 3 (p < 0.001). CONCLUSION: Despite substantial guideline alterations, median patient age remained largely unchanged in our TAVI cohort over the past 12 years. Therefore, increased age still appears to be the main reason to choose TAVI over SAVR. However, risk profiles declined substantially. Significant improvements in early outcomes suggest favorable influence of less invasive access routes, improved device platforms and growing user experience.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Niño , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodosRESUMEN
Background: Valve-in-valve (ViV) transfemoral transcatheter aortic valve implantation (TAVI) for failing aortic surgical bioprostheses or transcatheter heart valves (THV) has demonstrated a reasonable clinical and hemodynamic efficacy. Traditionally, self-expanding (SE) supra-annular THV are considered to result in superior hemodynamics compared with balloon-expandable intra-annular THV after ViV. However, so far no data are found on latest-generation intra-annular SE THV for aortic ViV procedures which might be superior with regard to coronary access or subsequent valve reintervention. Aim: We herein aim to evaluate a latest-generation SE intra-annular THV for aortic ViV procedures. Materials and methods: Between May 2022 and November 2022, five consecutive patients (4/5 female with mean age of 76.2 years and mean Society of Thoracic Surgeons predicted risk of mortality score of 2.9%) received ViV TAVI using the Navitor system (Abbott, Chicago, IL, USA) for treatment of failing surgical bioprostheses or THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium 3 (VARC-3) definitions. Results: At 30 days, absence of mortality and VARC-3 adjudicated clinical endpoints were documented. Echocardiography at 30 days revealed complete absence of paravalvular leakage and single-digit mean transvalvular gradients (mean of 6.0â mmHg) in all patients. Conclusion: The investigated intra-annular SE THV results in excellent 30-day outcomes for aortic ViV procedures for failing surgical bioprostheses or THV. Despite the intra-annular design, hemodynamic results were excellent, even in small bioprostheses. Ease of use of this valve platform is reflected by only two cycles of resheathing in five ViV procedures with hemodynamic stability during all steps of valve deployment.
RESUMEN
INTRODUCTION: The transplantation of neural crest derived stem cells (NCSC) is a potent alternative for the treatment of Hirschsprung's disease (HSCR). Cells to be transplanted should find an appropriate microenvironment to survive and differentiate. Influences of HSCR-smooth-muscle-protein extracts upon isolated myenteric plexus cells, dissociated dorsal root ganglia and NCSC were studied in vitro to investigate the quality of this microenvironment effects. METHODS: Postnatal human gut from children undergoing colonic resection due to HSCR was divided in segments. Smooth muscle was dissected and homogenized. Glial-cell-line-derived-neurotrophic-factor (GDNF) and transforming-growth-factor-ß-1 (TGFß-1) concentration were measured in the homogenates from the individual segment using ELISA. Myenteric plexus and dissociated dorsal root ganglia (DRG) cultures, as well as NCSCs were exposed to protein extracts derived from ganglionic and aganglionic HSCR segments, and their effect upon neurite outgrowth, survival, and branching was evaluated. RESULTS AND CONCLUSIONS: The amount of the factors varied considerably between the individual segments and also from patient to patient. Four major expression patterns could be detected. While all extracts tested lead to a significant increase in neurite outgrowth compared to the control, extracts from proximal segments tended to have more prominent effects. In one experiment, extracts from all individual segments of a single patient were tested. Neurite outgrowth, neuronal survival, and branching pattern varied from segment to segment, but all HSCR-muscle-protein extracts increased neuronal survival and network formation. Smooth muscle protein from aganglionic bowel supports the survival and outgrowth of myenteric neurons and NCSCs and is so an appropriate target for neural stem cell treatment.
Asunto(s)
Microambiente Celular , Tracto Gastrointestinal/patología , Enfermedad de Hirschsprung/patología , Plexo Mientérico/crecimiento & desarrollo , Plexo Mientérico/patología , Agregación Celular , Diferenciación Celular , Proliferación Celular , Supervivencia Celular , Células Cultivadas , Preescolar , Ensayo de Inmunoadsorción Enzimática , Ganglios Espinales/metabolismo , Ganglios Espinales/patología , Regulación de la Expresión Génica , Factor Neurotrófico Derivado de la Línea Celular Glial/genética , Factor Neurotrófico Derivado de la Línea Celular Glial/metabolismo , Enfermedad de Hirschsprung/genética , Enfermedad de Hirschsprung/cirugía , Humanos , Lactante , Recién Nacido , Proteínas Musculares/metabolismo , Neuritas/metabolismo , ARN Mensajero/genética , ARN Mensajero/metabolismo , Extractos de Tejidos , Factor de Crecimiento Transformador beta/metabolismoRESUMEN
BACKGROUND: Patients with chronic hemodialysis due to end-stage renal disease (ESRD) or severely impaired kidney function (CKD) constitute a relevant share of patients undergoing trans-catheter aortic valve implantation (TAVI). However, data on specific challenges and outcomes remain limited. AIM: We aimed to characterize this patient population, evaluate clinical results and assess the significance of calcification patterns. METHODS: This retrospective single-center analysis evaluated 2,712 TAVI procedures (2012-2019) according to baseline renal function: GFR < 30 ml/min/1.73m2 (CKD; n = 210), chronic hemodialysis (ESRD; n = 119) and control (CTRL; n = 2383). Valvular and vascular calcification patterns were assessed from contrast-enhanced multi-detector computed tomography. Outcomes were evaluated in accordance with the VARC-2 definitions. RESULTS: Operative risk was higher in ESRD and CKD vs. CTRL (STS-score 8.4% and 7.6% vs. 3.9%, p < 0.001) and patients with ESRD had more severe vascular calcifications (49.1% vs. 33.9% and 29.0%, p < 0.01). Immediate procedural results were similar but non-procedure-related major/life-threatening bleeding was higher in ESRD and CKD (5.0% and 5.3% vs. 1.6%, p < 0.01). 3-year survival was impaired in patients with ESRD and CKD (33.3% and 35.3% vs. 65.4%, p < 0.001). Multivariable analysis identified ESRD (HR 1.60), CKD (HR 1.79) and vascular calcifications (HR 1.29) as predictors for 3-year and vascular calcifications (HR 1.51) for 30-day mortality. CONCLUSION: Patients with ESRD and CKD constitute a vulnerable patient group with extensive vascular calcifications. Immediate procedural results were largely unaffected by renal impairment, yielding TAVI a particularly valuable treatment option in these high-risk operative patients. Mid-term survival was determined by underlying renal disease, cardiovascular comorbidities, and vascular calcifications as a novel risk marker.
Asunto(s)
Estenosis de la Válvula Aórtica , Fallo Renal Crónico , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Calcificación Vascular , Humanos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/epidemiología , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/cirugía , Factores de RiesgoRESUMEN
BACKGROUND: Left ventricular outflow tract (LVOT) calcification is known to be associated with adverse outcomes after transcatheter aortic valve implantation (TAVI) in patients receiving first-generation transcatheter heart valves (THV). AIMS: The aim of the present study was to assess the prevalence of LVOT calcification as well as its impact on outcomes in a contemporary TAVI patient cohort. METHODS: This retrospective single-centre analysis includes 1,207 patients who underwent transfemoral TAVI between 2012 and 2018 and in whom adequate contrast-enhanced multislice computed tomgraphy (MSCT) imaging for quantification of LVOT calcification was available. RESULTS: Significant LVOT calcification, defined as >10 mm3, was present in 37.4% (n=451) of the patient cohort. After applying propensity score matching there was no difference between patients without (w/o; n=358) and with (w; n=358) significant LVOT calcification with respect to baseline clinical characteristics. At 30 days, the composite of all-cause mortality and non-disabling/disabling stroke occurred more often in patients w LVOT calcification compared to those w/o (4.6 vs 10.1%, p=0.008). Moreover, the composite VARC-3 endpoint of device success at 30 days was in favour of patients w/o LVOT calcification (82.2% vs 73.4%, p=0.007). According to Kaplan-Meier analysis, all-cause mortality one year after TAVI was higher in patients w vs w/o LVOT calcification (12.9 vs 21.4 %, p=0.004). CONCLUSIONS: In patients undergoing TAVI, the presence of significant LVOT calcification is common and associated with worse short-term clinical and functional outcomes as well as higher one-year mortality rates compared to patients w/o LVOT calcification.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Calcinosis/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Tomografía Computarizada Multidetector , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
As valve-in-valve (ViV) transcatheter aortic valve implantation is still an evolving method, we evaluated the development of early and midterm outcomes after ViV and conventional redo-surgical aortic valve replacement (SAVR) over the past 2 decades. In-hospital databases were retrospectively screened for patients ≥60 years treated for failing bioprosthetic aortic valves at our center. Clinical and follow-up characteristics were compared between patients who underwent ViV or redo-SAVR according to valve academic research consortium-2 (VARC-2) definitions. The comparison of outcome parameters was adjusted for baseline differences between groups. Between June 2002 and April 2020, 209 patients with ViV and 65 redo-SAVR patients met inclusion criteria. No significant differences were found in 30 days (ViV 3.8%, SAVR 3.1%, p = 0.778) or 6-month mortality (ViV 14.0%, SAVR 7.5%, p = 0.283). As patients with ViV less frequently experienced acute kidney injury (stage II or III) and life-threatening bleeding, they more frequently reached the 30-day VARC-2 combined safety end point (79.2% vs 61.5%, odds ratio [OR] 2.540, p = 0.023). Patients with ViV less frequently reached clinical efficacy (68.3% vs 84.6%, OR 0.408, p = 0.041) and device success (79.9% vs 92.3%, OR 0.311, p = 0.040) end points, because of higher frequency of postprocedural transvalvular gradients >20 mm Hg. However, over the past decade, VARC-2 clinical efficacy and device success rates continuously increased in ViV cases. In conclusion, ViV and SAVR were associated with similar acute mortality and different beneficial and adverse outcome profiles in this single-center cohort. Results after ViV procedures have continuously improved over the past years.
Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del TratamientoRESUMEN
Valvular heart disease (VHD) is a chronic progressive condition with an increasing prevalence in the Western world due to aging populations. VHD is often diagnosed at a late stage when patients are symptomatic and the outcomes of therapy, including valve replacement, may be sub-optimal due the development of secondary complications, including left ventricular (LV) dysfunction. The clinical application of artificial intelligence (AI), including machine learning (ML), has promise in supporting not only early and more timely diagnosis, but also hastening patient referral and ensuring optimal treatment of VHD. As physician auscultation lacks accuracy in diagnosis of significant VHD, computer-aided auscultation (CAA) with the help of a commercially available digital stethoscopes improves the detection and classification of heart murmurs. Although used little in current clinical practice, CAA can screen large populations at low cost with high accuracy for VHD and faciliate appropriate patient referral. Echocardiography remains the next step in assessment and planning management and AI is delivering major changes in speeding training, improving image quality by pattern recognition and image sorting, as well as automated measurement of multiple variables, thereby improving accuracy. Furthermore, AI then has the potential to hasten patient disposal, by automated alerts for red-flag findings, as well as decision support in dealing with results. In management, there is great potential in ML-enabled tools to support comprehensive disease monitoring and individualized treatment decisions. Using data from multiple sources, including demographic and clinical risk data to image variables and electronic reports from electronic medical records, specific patient phenotypes may be identified that are associated with greater risk or modeled to the estimate trajectory of VHD progression. Finally, AI algorithms are of proven value in planning intervention, facilitating transcatheter valve replacement by automated measurements of anatomical dimensions derived from imaging data to improve valve selection, valve size and method of delivery.
RESUMEN
AIMS: The relevance of spontaneous echo contrast (SEC) and left atrial appendage thrombus (LAAT) in patients undergoing transcatheter aortic valve implantation (TAVI) remains unclear. In this study, we aimed to assess the prevalence of SEC and LAAT and evaluate the impact on periprocedural outcome after TAVI. METHODS AND RESULTS: A total of 2,549 consecutive patients underwent TAVI between 2008 and 2017. After exclusion of cases with insufficient imaging, concomitant procedures or severe intraprocedural complications, 1,558 cases were analysed. Three groups were defined according to (pre)thrombotic formations - moderate or severe SEC (n=89), LAAT (n=53), and reference (n=1,416). The primary outcome was disabling ischaemic stroke within 24 hours. The prevalence was 4.4% for LAAT and 5.4% for moderate/severe SEC. The primary outcome occurred more frequently in patients with moderate/severe SEC (6.8%) compared to the reference (2.1%) and LAAT (1.9%) groups (p=0.020). SEC was identified as an independent risk factor for the primary outcome (OR 3.54 [95% CI: 1.30-9.61], p=0.013). LAAT was associated with an impaired unadjusted one-year survival (43.4%) compared to the SEC (27.3%) and reference groups (18.7%, p<0.001). CONCLUSIONS: SEC and LAAT were detected in a relevant number of patients undergoing TAVI. SEC may represent an important risk factor for intraprocedural stroke; increased mortality was observed in patients with LAAT.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Accidente Cerebrovascular , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Ecocardiografía Transesofágica , Humanos , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversosRESUMEN
BACKGROUND: Bioresorbable scaffolds (BRS) have been shown to be inferior to drug-eluting stents in randomized trials. Nevertheless, patients treated during daily routine differ from those treated within randomized trials and thus need further long-term evaluation. The present investigation aims to address this lack. METHODS: Consecutive patients with coronary artery disease treated with implantation of everolimus-eluting BRS at 5 centers in Germany were included. Clinical follow-up was assessed up to 3 years. Analysis of clinical outcomes was performed by pooling of the individual patient data sets of each center. The major clinical endpoints of interest was target lesion failure (TLF) a composite of cardiac death, target vessel myocardial infarction and target lesion revascularization. Furthermore occurrence of definite scaffold thrombosis was evaluated. A multivariable Cox regression analysis was applied to identify independent predictors of TLF. RESULTS: A total of 1614 patients treated with BRS were analyzed (mean age 64.0 ± 10.9 years, 75.8% male, 28.3% diabetics). A total 1817 lesions were treated with BRS and 56.0% were considered to be complex. At 3 years, the rate of TLF was 17.1% and definite scaffold thrombosis was noted in 2.6%. Independent predictors of TLF were a higher age, diabetes, bifurcation, complex lesions and the use of small BRS. CONCLUSIONS: In this large-scale analysis of patients undergoing BRS implantation in daily routine, event rates were high, but in line with randomized studies. Predictors of TLF were identified which may optimize patient and lesion selection for BRS.
Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Implantes Absorbibles , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Everolimus , Femenino , Estudios de Seguimiento , Alemania , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Resultado del TratamientoRESUMEN
The enteric nervous system (ENS) controls gastrointestinal key functions and is mainly characterized by two ganglionated plexus located in the gut wall: the myenteric plexus and the submucous plexus. The ENS harbors a high number and diversity of enteric neurons and glial cells, which generate neuronal circuitry to regulate intestinal physiology. In the past few years, the pivotal role of enteric neurons in the underlying mechanism of several intestinal diseases was revealed. Intestinal diseases are associated with neuronal death that could in turn compromise intestinal functionality. Enteric neurogenesis and regeneration is therefore a crucial aspect within the ENS and could be revealed not only during embryogenesis and early postnatal periods, but also in the adulthood. Enteric glia and/or enteric neural precursor/progenitor cells differentiate into enteric neurons, both under homeostatic and pathologic conditions beyond the perinatal period. The unique role of the intestinal microbiota and serotonin signaling in postnatal and adult neurogenesis has been shown by several studies in health and disease. In this review article, we will mainly focus on different recent studies, which advanced the concept of postnatal and adult ENS neurogenesis. Moreover, we will discuss the key factors and underlying mechanisms, which promote enteric neurogenesis. Finally, we will shortly describe neurogenesis of transplanted enteric neural progenitor cells. Anat Rec, 302:1345-1353, 2019. © 2019 Wiley Periodicals, Inc.
Asunto(s)
Sistema Nervioso Entérico/fisiología , Sistema Nervioso Entérico/fisiopatología , Microbioma Gastrointestinal , Enfermedades Neurodegenerativas/terapia , Neurogénesis , Serotonina/metabolismo , Animales , Sistema Nervioso Entérico/citología , Humanos , Longevidad , Enfermedades Neurodegenerativas/microbiología , Transducción de SeñalRESUMEN
Since several years, the enteric nervous system (ENS) is getting more and more in the focus of gastrointestinal research. While the main interest was credited for years to the enteric neurons and their functional properties, less attention has been paid on the enteric glial cells (EGCs). Although the similarity of EGCs to central nervous system (CNS) astrocytes has been demonstrated a long time ago, EGCs were investigated in more detail only recently. Similar to the CNS, there is not "the" EGC, but also a broad range of diversity. Based on morphology and protein expression, such as glial fibrillary acidic protein (GFAP), S100, or Proteolipid-protein-1 (PLP1), several distinct glial types can be differentiated. Their heterogeneity in morphology, localization, and transcription as well as interaction with surrounding cells indicate versatile functional properties of these cells for gut function in health and disease. Although NG2 is found in a subset of CNS glial cells, it did not colocalize with the glial marker S100 or GFAP in the ENS. Instead, it in part colocalize with PDGFRα, as it does in the CNS, which do stain fibroblast-like cells in the gastrointestinal tract. Moreover, there seem to be species dependent differences. While GFAP is always found in the rodent ENS, this is completely different for the human gut. Only the compromised human ENS shows a significant amount of GFAP-positive glial cells. So, in general we can conclude that the EGC population is species specific and as complex as CNS glia. Anat Rec, 302:1333-1344, 2019. © 2019 Wiley Periodicals, Inc.
Asunto(s)
Sistema Nervioso Entérico/fisiopatología , Proteína Ácida Fibrilar de la Glía/metabolismo , Neuroglía/citología , Neuroglía/patología , Proteínas S100/metabolismo , Animales , Sistema Nervioso Entérico/metabolismo , Humanos , Neuroglía/metabolismo , Transducción de SeñalRESUMEN
AIMS: Women and men suffering from coronary artery disease differ in their risk profiles. We sought to investigate the impact of sex on two-year outcomes after BVS implantation in routine clinical practice. METHODS AND RESULTS: Sex-based analysis of clinical outcomes was carried out by pooling the individual patient data of the ISAR-ABSORB and KUM-ABSORB registries performed in four high-volume tertiary centres in Munich. Of the total of 1,032 patients, 259 (25.1%) were women. The primary composite endpoint of death, target vessel myocardial infarction (TV-MI) and target lesion revascularisation (TLR) up to two years occurred in 13.2% of women and 17.9% of men (p=0.12). Compared to men, women experienced numerically lower rates of TLR and definite or probable BVS thrombosis - 7.5% vs 12.4% (p=0.051) and 1.2% and 2.7% (p=0.20), respectively. Independent predictors of increased risk for TLR were use of smaller size BVS (HR 1.28, 95% CI: 1.02-1.62), while being a woman was a protective factor (HR 0.59, 95% CI: 0.35-1.00). CONCLUSIONS: BVS used in a routine setting tend to perform better among women compared to men, which might be partially related to the lower complexity of their coronary artery disease.