Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Medicina (Kaunas) ; 56(1)2020 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-31968630

RESUMEN

Background and Objectives: the aim of the study was to evaluate the repeatability and reproducibility of optical microangiography (OMAG)-based optical coherence tomography angiography (OCTA) in the optic nerve head (ONH) and radial peripapillary capillary (RPC) perfusion assessment of healthy eyes. Materials and Methods: in this observational study, a total of 40 healthy subjects underwent ONH evaluation, using an OMAG-based OCTA system at baseline (T0), after 30 min (T1), and after 7 days (T2). The main outcome measures were the vessel density (VD) and flux index (FI) of the RPCs, as well as peri-papillary retinal nerve fibre layer (pRNFL) thickness. The analysis was performed by two observers independently. The coefficient of repeatability (CR), within the subject coefficient of variation (CVw) and intrasession correlation coefficient (ICC), to evaluate intrasession repeatability of measurements was calculated for each observer. Results: the high intrasession and intersession repeatability and reproducibility were assessed in the two observers for all three outcome measures. Of note, the CRs for the first and the second observer were 0.011 (95% confidence interval (CI) 0.009-0.014) and 0.016 (95% CI 0.013-0.020) for FI, 0.016 (95% CI 0.013-0.021) and 0.017 (95% CI 0.014-0.021) for VD, and 2.400 (95% CI 1.948-3.092) and 3.732 (95% CI 3.064-4.775) for pRNFL thickness, respectively. The agreement between them was excellent for pRNFL assessment and very good for FI and VD. Conclusion: OCTA has a great potential in the accurate assessment of ONH and peri-papillary microcirculation. It allows for repeated and reproducible measurements without multiple scans-related bias, thus guaranteeing an independent operator analysis with good reproducibility and repeatability.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Disco Óptico/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Adulto , Capilares/anatomía & histología , Capilares/diagnóstico por imagen , Femenino , Humanos , Masculino , Disco Óptico/anatomía & histología , Disco Óptico/irrigación sanguínea , Reproducibilidad de los Resultados , Neuronas Retinianas/ultraestructura
2.
J Cataract Refract Surg ; 49(5): 512-517, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36700935

RESUMEN

PURPOSE: To evaluate visual performance and quality of life after bilateral implantation of 2 extended depth-of-focus intraocular lenses (EDOF IOLs). SETTING: Ophthalmology Clinic, Department of Medicine and Science of Ageing, University "G. d'Annunzio" Chieti-Pescara, Italy, and Ophthalmic Unit, Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Italy. DESIGN: Prospective clinical study. METHODS: 60 eyes of 30 patients with senile cataract were enrolled in this study. Patients underwent phacoemulsification and bilateral implantation of the Mini WELL IOL in the dominant eye and the Mini WELL PROXA IOL in the nondominant eye within a month. The main outcome measures over a 3-month follow-up period were uncorrected and corrected visual acuity at different distances (33 cm, 60 cm, and 4 m), defocus curve, contrast sensitivity, and patient satisfaction (evaluated by mean of the National Eye Institute Refractive Error Quality-of-Life instrument-42 questionnaire). RESULTS: Binocular uncorrected visual acuity at 90 days was 0.03 ± 0.11 logMAR for long distance, 0.05 ± 0.10 logMAR for intermediate distance, 0.03 ± 0.08 logMAR at 40 cm, and 0.06 ± 0.08 logMAR at 33 cm. Statistically significant differences between the 2 EDOF IOLs in favor of Mini WELL PROXA IOL were observed for uncorrected near visual acuity at 40 and 33 cm ( P < .001 and P < .001, respectively) and for distance-corrected near visual acuity at 40 cm ( P < .001). Significant differences between the 2 IOLs in the defocus curves were reported. CONCLUSIONS: In this small pilot study, bilateral implantation of Mini WELL IOL and Mini WELL PROXA IOL achieved good quantity and quality of vision.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Cirujanos , Humanos , Implantación de Lentes Intraoculares , Satisfacción del Paciente , Proyectos Piloto , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia , Calidad de Vida , Refracción Ocular , Visión Binocular
3.
J Ophthalmol ; 2021: 6624904, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33628475

RESUMEN

OBJECTIVES: The inverted internal limiting membrane (ILM) flap technique has been shown to increase the success rate in large full-thickness macular holes (FTMHs) and in FTMHs associated with high myopia. The aim of our study was to confirm the efficacy and safety of inverted ILM flap technique in idiopathic FTMHs independent of their dimensions and to assess functional outcomes and their correlation to morphologic findings. METHODS: Sixteen consecutive patients affected by idiopathic FTMH were enrolled in this prospective study. The preoperative mean (±SD) diameter of the FTMH was 422 (±106) µm. All patients underwent vitrectomy and ILM peeling with inverted ILM flap. At 1-, 3-, and 6-month postoperative visits, visual acuity measurement, indirect ophthalmoscopy, and microperimetry were performed, and the foveal contour and the integrity of the ellipsoid zone (EZ) and external limiting membrane (ELM) were investigated using spectral domain optical coherence tomography (SD-OCT). RESULTS: At six months postoperatively, 15 out of 16 (93.75%) patients obtained FTMH closure. The mean best corrected visual acuity (BCVA) improved from 1.1 LogMAR to 0.3 LogMAR, and the mean retinal sensitivity (MS) improved from 7.2 to 23.4 dB. ELM defects were evident in 1 out of 16 (6.25%) eyes, and EZ defects were detected in 2 out of 16 (12,50%) eyes. A statistically significant relationship was observed between BCVA, MS, and EZ reconstitution at each follow-up visit. CONCLUSIONS: Results confirm that the inverted ILM flap technique is a safe and effective option for FTMH treatment and show a strong correlation between higher BCVAs and MSs and EZ reconstitution after surgery.

4.
Acta Ophthalmol ; 98(6): e761-e767, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32020755

RESUMEN

PURPOSE: To evaluate, using optical coherence tomography-angiography (OCT-A), the vascular features of good bleb function after XEN gel implantation (XGI) for uncontrolled glaucoma. METHODS: Forty-three patients (43 eyes), who underwent XGI, were enrolled. According to the intraocular pressure (IOP) reduction, patients were classified into Group 1 (21 eyes; success) and Group 2 (22 eyes; failure). Optical coherence tomography-angiography (OCT-A) was performed to image the vascularization of the conjunctival bleb-wall. The main outcomes were as follows: vessel displacement areas (VDAs), major vessel displacement area (MVDA; mm2 ), non-flow whole area (NFWA; mm2 ) and bleb-wall vessel density (BVD; %). Co-registered B-scans were also considered to evaluate the bleb-wall cyst-like structure density and area (BCSD, cysts/mm2 ; BCSA, mm2 ), and the bleb-wall thickness (BT, µm). RESULTS: Mean postoperative follow-up was 7.5 ± 0.14 months; Group 1 and 2 IOP were 14.0 ± 2.5 and 25.3 ± 2.1 mmHg, respectively (p < 0.001). Greater VDA (p < 0.001), MVDA (p = 0.046) and NFWA (p = 0.001) values, and lower BVD (p < 0.001) was found in Group 1 compared to Group 2. Group 1 showed higher BSCD, BSCA and BT values compared to Group 2 (p < 0.001). Postoperative IOP positively correlated with BVD (r = 0.567; p = 0.003), but negatively with VDAs, MVDA (r = -0.581, p = 0.002; r = -0.619, p = 0.001, respectively), BCSD, BCSA (r = -0.580; p = 0.002; r = -0.664; p < 0.001) and BT (r = -0.627, p = 0.001). CONCLUSION: Successful filtration blebs after XGI present numerous and large areas of vessel displacement within the bleb-wall, along with a rarefied vascular network. These OCT-A features can be considered angiographic biomarkers of a good aqueous humour percolation through the bleb-wall layers.


Asunto(s)
Conjuntiva , Glaucoma de Ángulo Abierto , Trabeculectomía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía/métodos , Conjuntiva/diagnóstico por imagen , Conjuntiva/cirugía , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Periodo Posoperatorio , Tomografía de Coherencia Óptica/métodos , Trabeculectomía/métodos
5.
Biomed Res Int ; 2020: 7627128, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33204714

RESUMEN

PURPOSE: To describe the reliability and the limits of bursa premacularis (BPM) evaluation using a swept source optical coherence tomography (SS-OCT) device with enface and 16 mm-high definition (HD) longitudinal scans. METHODS: 60 eyes of 60 subjects were enrolled and imaged with SS-OCT system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). BPM area was measured using enface scans imported to ImageJ. HD horizontal and vertical longitudinal scans centered at the fovea were used to detect width (W) and central thickness (CT) of BPM at baseline (T0) and after 30 minutes (T30) performed by two different observers. An enhanced vitreous visualization software provided by the manufacturer of the device was used to highlight vitreous structures. RESULTS: BPM was identifiable in 100% of eyes using both horizontal and vertical longitudinal scans. On horizontal scan, BPM was not entirely measurable in 21.7% and in 18.3% of cases at T0 and T30, respectively. On vertical scan, BPM was not entirely measurable in 75.0% and in 81.7% at T0 and T30, respectively. No statistically significant differences were found between the two different time measurements with an intraclass correlation coefficient above 70%. Median BPM area was 26.9 (Q1-Q3: 19.5-40.5) mm2. In en face imaging, the most frequent BPM shape was the boat one. CONCLUSION: SS-OCT is a reliable tool for a detailed quantification and mapping of BPM, and it is able to add useful details about the morphological BPM features in youth population. However, the enhanced visualization of the vitreous structures is still a challenge, also with the most forefront devices.


Asunto(s)
Fóvea Central/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Cuerpo Vítreo/diagnóstico por imagen , Adulto , Estudios Transversales , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA