Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Magn Reson Med ; 87(4): 1923-1937, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34783383

RESUMEN

PURPOSE: The purpose of this study was to evaluate the accuracy of four-dimensional (4D) flow MRI for direct assessment of peak velocity, flow volume, and momentum of a mitral regurgitation (MR) flow jets using an in vitro pulsatile jet flow phantom. We systematically investigated the impact of spatial resolution and quantification location along the jet on flow quantities with Doppler ultrasound as a reference for peak velocity. METHODS: Four-dimensional flow MRI data of a pulsatile jet through a circular, elliptical, and 3D-printed patient-specific MR orifice model was acquired with varying spatial resolution (1.5-5 mm isotropic voxel). Flow rate and momentum of the jet were quantified at various axial distances (x = 0-50 mm) and integrated over time to calculate Voljet and MTIjet . In vivo assessment of Voljet and MTIjet was performed on 3 MR patients. RESULTS: Peak velocities were comparable to Doppler ultrasound (3% error, 1.5 mm voxel), but underestimated with decreasing spatial resolution (-40% error, 5 mm voxel). Voljet was similar to regurgitant volume (RVol) within 5 mm, and then increased linearly with the axial distance (19%/cm) because of flow entrainment. MTIjet remained steady throughout the jet (2%/cm) as theoretically predicted. Four and 9 voxels across the jet were required to measure flow volume and momentum-time-integral within 10% error, respectively. CONCLUSION: Four-dimensional flow MRI detected accurate peak velocity, flow rate, and momentum for in vitro MR-mimicking flow jets. Spatial resolution significantly impacted flow quantitation, which otherwise followed predictions of flow entrainment and momentum conservation. This study provides important preliminary information for accurate in vivo MR assessment using 4D flow MRI.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Velocidad del Flujo Sanguíneo , Humanos , Imagen por Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Flujo Pulsátil , Ultrasonografía
2.
J Vasc Interv Radiol ; 32(2): 211-219, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33349507

RESUMEN

PURPOSE: To evaluate safety and efficacy of segmental yttrium-90 (Y90) radioembolization for hepatocellular carcinoma (HCC) after transjugular intrahepatic portosystemic shunt (TIPS) placement. The hypothesis was liver sparing segmental Y90 for HCC after TIPS would provide high antitumor response with a tolerable safety profile. MATERIALS AND METHODS: This single-arm retrospective study included 39 patients (16 women, 23 men) with ages 49-81 years old who were treated with Y90. Child-Pugh A/B liver dysfunction was present in 72% (28/39) with a median Model for End-stage Liver Disease score of 18 (95% confidence interval, 16.4-19.4). Primary outcomes were clinical and biochemical toxicities and antitumor imaging response by World Health Organization (WHO) and European Association for the Study of the Liver (EASL) criteria. Secondary outcomes were orthotopic liver transplantation (OLT), time to progression (TTP), and overall survival (OS) estimates by the Kaplan-Meier method. RESULTS: The 30-day mortality was 0%. Grade 3+ clinical adverse events and grade 3+ hyperbilirubinemia occurred in 5% (2/39) and 0% (0/39), respectively. Imaging response was achieved in 58% (22/38, WHO criteria) and 74% (28/38, EASL criteria), respectively. Median TTP was 16.1 months for any cause and 27.5 months for primary index lesions. OLT was completed in 88% (21/24) of listed patients at a median time of 6.1 months (range, 0.9-11.7 months). Median OS was 31.6 months and 62.9 months censored and uncensored to OLT, respectively. CONCLUSIONS: Segmental Y90 for HCC appears safe and efficacious in patients after TIPS. Preserved transplant eligibility suggests that Y90 is a useful tool for bridging these patients to liver transplantation.


Asunto(s)
Carcinoma Hepatocelular/terapia , Embolización Terapéutica , Neoplasias Hepáticas/terapia , Derivación Portosistémica Intrahepática Transyugular , Radiofármacos/administración & dosificación , Radioisótopos de Itrio/administración & dosificación , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/mortalidad , Bases de Datos Factuales , Progresión de la Enfermedad , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/mortalidad , Masculino , Persona de Mediana Edad , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Derivación Portosistémica Intrahepática Transyugular/mortalidad , Radiofármacos/efectos adversos , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Radioisótopos de Itrio/efectos adversos
3.
J Cardiovasc Magn Reson ; 23(1): 138, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-34865629

RESUMEN

BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS: This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland-Altman analysis, and Cohen's kappa. RESULTS: Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS: Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population.


Asunto(s)
Cardiomiopatía Hipertrófica , Insuficiencia de la Válvula Mitral , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
Heart Fail Clin ; 17(1): 135-147, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33220882

RESUMEN

In heart failure (HF), the impaired heart loses its ability to competently eject blood during systole or fill with blood during diastole, manifesting in multifaceted abnormal intracardiac or intravascular flow dynamics. Conventional imaging techniques are limited in their ability to evaluate multidirectional multidimensional flow alterations in HF. Four-dimensional (4-D) flow magnetic resonance imaging (MRI) has emerged as a promising technique to comprehensively visualize and quantify changes in 3-dimensional blood flow dynamics in complex cardiovascular diseases. This article reviews emerging applications of 4-D flow MRI hemodynamic markers in HF and etiologies at risk of progressing to HF.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico , Hemodinámica/fisiología , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Vasos Sanguíneos/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Humanos , Espectroscopía de Resonancia Magnética
5.
Semin Intervent Radiol ; 40(1): 21-26, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37152799

RESUMEN

Complications of overshunting, including hepatic encephalopathy and hepatic insufficiency, remain prevalent following transjugular intrahepatic portosystemic shunt (TIPS) creation. Smaller diameter TIPS may reduce the risk of overshunting, but the use of smaller stents must be weighed against the risk of undershunting and persistent or recurrent hemorrhage, ascites, and other complications of portal hypertension. This article explores the question of optimal shunt diameter by examining outcomes for smaller diameter TIPS stent-grafts (<10 mm), underdilated stent-grafts, and variable diameter stent-grafts.

6.
Cardiovasc Intervent Radiol ; 45(8): 1117-1128, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35732931

RESUMEN

PURPOSE: Unresectable intrahepatic cholangiocarcinoma (ICC) signifies a poor prognosis with limited treatment options beyond systemic chemotherapy. This study's purpose was to evaluate the safety, efficacy, and potential for downstaging to resection of yttrium-90 (Y90) radioembolization for treatment of unresectable ICC. MATERIALS AND METHODS: From 2004 to 2020, 136 patients with unresectable ICC were treated with radioembolization at a single institution. Retrospective review was performed of a prospectively collected database. Outcomes were (1) biochemical and clinical toxicities, (2) local tumor response, (3) time to progression, and (4) overall survival (OS) after Y90. Univariate/multivariate survival analyses were performed. A subgroup analysis was performed to calculate post-resection recurrence and OS in patients downstaged to resection after Y90. RESULTS: Grade 3+ clinical and biochemical toxicities were 7.6% (n = 10) and 4.9% (n = 6), respectively. Best index lesion response was complete response in 2 (1.5%), partial response in 42 (32.1%), stable disease in 82 (62.6%), and progressive disease in 5 (3.8%) patients. Median OS was 14.2 months. Solitary tumor (P < 0.001), absence of vascular involvement (P = 0.009), and higher serum albumin (P < 0.001) were independently associated with improved OS. Eleven patients (8.1%) were downstaged to resection and 2 patients (1.5%) were bridged to transplant. R0-resection was achieved in 8/11 (72.7%). Post-resection median recurrence and OS were 26.3 months and 39.9 months, respectively. CONCLUSION: Y90 has an acceptable safety profile and high local disease control rates for the treatment of unresectable ICC. Downstaging to resection with > 3 years survival supports the therapeutic role of Y90 for unresectable ICC. LEVEL OF EVIDENCE: Level 3, single-arm single-center cohort study.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Embolización Terapéutica , Neoplasias Hepáticas , Neoplasias de los Conductos Biliares/patología , Conductos Biliares Intrahepáticos/patología , Colangiocarcinoma/cirugía , Estudios de Cohortes , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Radioisótopos de Itrio/uso terapéutico
7.
Int J Cardiovasc Imaging ; 37(9): 2755-2765, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33523363

RESUMEN

To noninvasively assess left atrial (LA) kinetic energy (KE) in hypertrophic cardiomyopathy (HCM) patients using 4D flow MRI and evaluate coupling associations with mitral regurgitation (MR) and left ventricular outflow tract (LVOT) obstruction. Twenty-nine retrospectively identified patients with HCM underwent 4D flow MRI. MRI-estimated peak LVOT pressure gradient (∆PMRI) was used to classify patients into non-obstructive and obstructive HCM. Time-resolved volumetric LA kinetic energy (KELA) was computed throughout systole. Average systolic (KELA-avg) and peak systolic (KELA-peak) KELA were compared between non-obstructive and obstructive HCM groups, and associations to MR severity and LVOT ∆PMRI were tested.The study included 15 patients with non-obstructive HCM (58.6 [45.9, 65.2] years, 7 females) and 14 patients with obstructive HCM (51.9 [47.6, 62.6] years, 6 females). Obstructive HCM patients demonstrated significantly elevated instantaneous KELA over all systolic time-points compared to non-obstructive HCM (P < 0.05). Obstructive HCM patients also demonstrated higher KELA-avg (14.8 [10.6, 20.4] J/m3 vs. 33.4 [23.9, 61.3] J/m3, P < 0.001) and KELA-peak (22.1 [15.9, 28.7] J/m3 vs. 57.2 [44.5, 121.4] J/m3, P < 0.001) than non-obstructive HCM. MR severity was significantly correlated with KELA-avg (rho = 0.81, P < 0.001) and KELA-peak (rho = 0.79, P < 0.001). LVOT ∆PMRI was strongly correlated with KELA metrics in obstructive HCM (KELA-avg: rho = 0.86, P < 0.001; KELA-peak: rho = 0.85, P < 0.001).In HCM patients, left atrial kinetic energy, by 4D flow MRI, is associated with MR severity and the degree of LVOT obstruction.


Asunto(s)
Cardiomiopatía Hipertrófica , Insuficiencia de la Válvula Mitral , Obstrucción del Flujo Ventricular Externo , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA