Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 129(27): 275001, 2022 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-36638294

RESUMEN

We present measurements of ice-ablator mix at stagnation of inertially confined, cryogenically layered capsule implosions. An ice layer thickness scan with layers significantly thinner than used in ignition experiments enables us to investigate mix near the inner ablator interface. Our experiments reveal for the first time that the majority of atomically mixed ablator material is "dark" mix. It is seeded by the ice-ablator interface instability and located in the relatively cooler, denser region of the fuel assembly surrounding the fusion hot spot. The amount of dark mix is an important quantity as it is thought to affect both fusion fuel compression and burn propagation when it turns into hot mix as the burn wave propagates through the initially colder fuel region surrounding an igniting hot spot. We demonstrate a significant reduction in ice-ablator mix in the hot-spot boundary region when we increase the initial ice layer thickness.

2.
Phys Rev Lett ; 126(2): 025002, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33512229

RESUMEN

Inertial confinement fusion implosions must achieve high in-flight shell velocity, sufficient energy coupling between the hot spot and imploding shell, and high areal density (ρR=∫ρdr) at stagnation. Asymmetries in ρR degrade the coupling of shell kinetic energy to the hot spot and reduce the confinement of that energy. We present the first evidence that nonuniformity in the ablator shell thickness (∼0.5% of the total thickness) in high-density carbon experiments is a significant cause for observed 3D ρR asymmetries at the National Ignition Facility. These shell-thickness nonuniformities have significantly impacted some recent experiments leading to ρR asymmetries on the order of ∼25% of the average ρR and hot spot velocities of ∼100 km/s. This work reveals the origin of a significant implosion performance degradation in ignition experiments and places stringent new requirements on capsule thickness metrology and symmetry.

3.
Phys Rev Lett ; 122(25): 255702, 2019 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-31347873

RESUMEN

We present laser-driven shock compression experiments on cryogenic liquid deuterium to 550 GPa along the principal Hugoniot and reflected-shock data up to 1 TPa. High-precision interferometric Doppler velocimetry and impedance-matching analysis were used to determine the compression accurately enough to reveal a significant difference as compared to state-of-the-art ab initio calculations and thus, no single equation of state model fully matches the principal Hugoniot of deuterium over the observed pressure range. In the molecular-to-atomic transition pressure range, models based on density functional theory calculations predict the maximum compression accurately. However, beyond 250 GPa along the principal Hugoniot, first-principles models exhibit a stiffer response than the experimental data. Similarly, above 500 GPa the reflected shock data show 5%-7% higher compression than predicted by all current models.

4.
Phys Rev Lett ; 120(24): 245003, 2018 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-29956968

RESUMEN

A series of cryogenic, layered deuterium-tritium (DT) implosions have produced, for the first time, fusion energy output twice the peak kinetic energy of the imploding shell. These experiments at the National Ignition Facility utilized high density carbon ablators with a three-shock laser pulse (1.5 MJ in 7.5 ns) to irradiate low gas-filled (0.3 mg/cc of helium) bare depleted uranium hohlraums, resulting in a peak hohlraum radiative temperature ∼290 eV. The imploding shell, composed of the nonablated high density carbon and the DT cryogenic layer, is, thus, driven to velocity on the order of 380 km/s resulting in a peak kinetic energy of ∼21 kJ, which once stagnated produced a total DT neutron yield of 1.9×10^{16} (shot N170827) corresponding to an output fusion energy of 54 kJ. Time dependent low mode asymmetries that limited further progress of implosions have now been controlled, leading to an increased compression of the hot spot. It resulted in hot spot areal density (ρr∼0.3 g/cm^{2}) and stagnation pressure (∼360 Gbar) never before achieved in a laboratory experiment.

5.
Neuroradiology ; 59(10): 963-969, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28785801

RESUMEN

PURPOSE: In the chronic phase after mild traumatic brain injury (mTBI), microhaemorrhages are frequently detected on magnetic resonance imaging (MRI). It is however unclear whether microhaemorrhages are associated with functional outcome and which MRI sequence is most appropriate to address this association. We aimed to determine the association between microhaemorrhages and functional outcome in the chronic posttraumatic phase after injury with the most suitable MRI sequence to address this association. METHODS: One hundred twenty-seven patients classified with mTBI admitted to the outpatient clinic from 2008 to 2015 for persisting posttraumatic complaints were stratified according to the presence of MRI abnormalities (n = 63 (MRI+ group) and n = 64 without abnormalities (MRI- group)). For the detection of microhaemorrhages, susceptibility-weighted imaging (SWI) and T2* gradient recalled echo (T2*GRE) were used. The relation between the functional outcome (dichotomized Glasgow Outcome Scale Extended scores) and the number and localization of microhaemorrhages was analysed using binary logistic regression. RESULTS: SWI detected twice as many microhaemorrhages compared to T2*GRE: 341 vs. 179. Lesions were predominantly present in the frontal and temporal lobes. Unfavourable outcome was present in 67% of the MRI+ group with a significant association of total number of microhaemorrhages in the temporal cortical area on SWI (OR 0.43 (0.21-0.90) p = 0.02), with an explained variance of 44%. The number of microhaemorrhages was not correlated with the number of posttraumatic complaints. CONCLUSION: An unfavourable outcome in the chronic posttraumatic phase is associated with the presence and number of microhaemorrhages in the temporal cortical area. SWI is preferably used to detect these microhaemorrhages.


Asunto(s)
Conmoción Encefálica/diagnóstico por imagen , Hemorragia Cerebral/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Enfermedad Crónica , Femenino , Escala de Coma de Glasgow , Escala de Consecuencias de Glasgow , Humanos , Masculino , Persona de Mediana Edad , Recuperación de la Función , Estudios Retrospectivos
6.
Phys Rev Lett ; 115(10): 105001, 2015 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-26382681

RESUMEN

Hydrodynamic instabilities can cause capsule defects and other perturbations to grow and degrade implosion performance in ignition experiments at the National Ignition Facility (NIF). Here, we show the first experimental demonstration that a strong unsupported first shock in indirect drive implosions at the NIF reduces ablation front instability growth leading to a 3 to 10 times higher yield with fuel ρR>1 g/cm(2). This work shows the importance of ablation front instability growth during the National Ignition Campaign and may provide a path to improved performance at the high compression necessary for ignition.

7.
Phys Rev Lett ; 114(17): 175001, 2015 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-25978240

RESUMEN

Recent experiments on the National Ignition Facility [M. J. Edwards et al., Phys. Plasmas 20, 070501 (2013)] demonstrate that utilizing a near-vacuum hohlraum (low pressure gas-filled) is a viable option for high convergence cryogenic deuterium-tritium (DT) layered capsule implosions. This is made possible by using a dense ablator (high-density carbon), which shortens the drive duration needed to achieve high convergence: a measured 40% higher hohlraum efficiency than typical gas-filled hohlraums, which requires less laser energy going into the hohlraum, and an observed better symmetry control than anticipated by standard hydrodynamics simulations. The first series of near-vacuum hohlraum experiments culminated in a 6.8 ns, 1.2 MJ laser pulse driving a 2-shock, high adiabat (α∼3.5) cryogenic DT layered high density carbon capsule. This resulted in one of the best performances so far on the NIF relative to laser energy, with a measured primary neutron yield of 1.8×10(15) neutrons, with 20% calculated alpha heating at convergence ∼27×.

8.
Phys Rev Lett ; 115(5): 055001, 2015 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-26274424

RESUMEN

We report on the first layered deuterium-tritium (DT) capsule implosions indirectly driven by a "high-foot" laser pulse that were fielded in depleted uranium hohlraums at the National Ignition Facility. Recently, high-foot implosions have demonstrated improved resistance to ablation-front Rayleigh-Taylor instability induced mixing of ablator material into the DT hot spot [Hurricane et al., Nature (London) 506, 343 (2014)]. Uranium hohlraums provide a higher albedo and thus an increased drive equivalent to an additional 25 TW laser power at the peak of the drive compared to standard gold hohlraums leading to higher implosion velocity. Additionally, we observe an improved hot-spot shape closer to round which indicates enhanced drive from the waist. In contrast to findings in the National Ignition Campaign, now all of our highest performing experiments have been done in uranium hohlraums and achieved total yields approaching 10^{16} neutrons where more than 50% of the yield was due to additional heating of alpha particles stopping in the DT fuel.

9.
Phys Rev Lett ; 114(14): 145004, 2015 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-25910132

RESUMEN

Experiments have recently been conducted at the National Ignition Facility utilizing inertial confinement fusion capsule ablators that are 175 and 165 µm in thickness, 10% and 15% thinner, respectively, than the nominal thickness capsule used throughout the high foot and most of the National Ignition Campaign. These three-shock, high-adiabat, high-foot implosions have demonstrated good performance, with higher velocity and better symmetry control at lower laser powers and energies than their nominal thickness ablator counterparts. Little to no hydrodynamic mix into the DT hot spot has been observed despite the higher velocities and reduced depth for possible instability feedthrough. Early results have shown good repeatability, with up to 1/2 the neutron yield coming from α-particle self-heating.

10.
Br J Cancer ; 111(4): 726-35, 2014 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-25025962

RESUMEN

BACKGROUND: Over the past years, some members of the family of suppressor of cytokine signalling (SOCS) proteins have emerged as potential tumour suppressors. This study aimed at investigating the clinical significance of SOCS proteins in colorectal carcinoma (CRC). METHODS: We integrated publicly available microarray expression data on CRC in humans, analysed the expression pattern of SOCSs and assessed the predictive power of SOCS2 and SOCS6 for diagnostic purposes by generating receiver operating characteristic curves. Using laser microdissected patient material we assessed SOCS expression on RNA and protein levels as well as their methylation status in an independent CRC patient cohort. Finally, we investigated the prognostic value of SOCS2 and SOCS6. RESULTS: The meta-analysis as well as the independent patient cohort analysis reveal a stage-independent downregulation of SOCS2 and SOCS6 and identify both molecules as diagnostic biomarkers for CRC. We demonstrate a different methylation pattern within the SOCS2 promoter between tumour tissue and normal control tissue in 25% of CRC patients. Furthermore, early CRC stage patients with low expression of SOCS2 display significantly shorter disease-free survival. CONCLUSIONS: Our data offers evidence that SOCS2 and SOCS6 levels are reduced in CRC and may serve as diagnostic biomarkers for CRC patients.


Asunto(s)
Adenocarcinoma/metabolismo , Neoplasias Colorrectales/metabolismo , Proteínas Supresoras de la Señalización de Citocinas/metabolismo , Adenocarcinoma/patología , Adenoma/metabolismo , Adenoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Secuencia de Bases , Biomarcadores de Tumor , Neoplasias Colorrectales/patología , Metilación de ADN , Supervivencia sin Enfermedad , Regulación hacia Abajo , Femenino , Expresión Génica , Humanos , Masculino , Persona de Mediana Edad , Datos de Secuencia Molecular , Estadificación de Neoplasias , Pronóstico , Regiones Promotoras Genéticas , Curva ROC , Proteínas Supresoras de la Señalización de Citocinas/genética
11.
Phys Rev Lett ; 112(18): 185003, 2014 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-24856703

RESUMEN

Ignition experiments have shown an anomalous susceptibility to hydrodynamic instability growth. To help understand these results, the first hydrodynamic instability growth measurements in indirectly driven implosions on the National Ignition Facility were performed at ignition conditions with peak radiation temperatures up to ∼300 eV. Plastic capsules with two-dimensional preimposed, sinusoidal outer surface modulations of initial wavelengths of 240 (corresponding to a Legendre mode number of 30), 120 (mode 60), and 80 µm (mode 90) were imploded by using actual low-adiabat ignition laser pulses. The measured growth was in excellent agreement, validating 2D hydra simulations for the most dangerous modes in the acceleration phase. These results reinforce confidence in the predictive capability of calculations that are paramount to illuminating the path toward ignition.

12.
Phys Rev Lett ; 112(2): 025002, 2014 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-24484021

RESUMEN

We present the first results from an experimental campaign to measure the atomic ablator-gas mix in the deceleration phase of gas-filled capsule implosions on the National Ignition Facility. Plastic capsules containing CD layers were filled with tritium gas; as the reactants are initially separated, DT fusion yield provides a direct measure of the atomic mix of ablator into the hot spot gas. Capsules were imploded with x rays generated in hohlraums with peak radiation temperatures of ∼294 eV. While the TT fusion reaction probes conditions in the central part (core) of the implosion hot spot, the DT reaction probes a mixed region on the outer part of the hot spot near the ablator-hot-spot interface. Experimental data were used to develop and validate the atomic-mix model used in two-dimensional simulations.

13.
Neth Heart J ; 22(10): 449-55, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25187012

RESUMEN

OBJECTIVE: Implantable cardioverter defibrillators (ICD) and cardiac resynchronisation therapy (CRT) have substantially improved the survival of patients with cardiomyopathy. Eligibility for this therapy requires a left ventricular ejection fraction (LVEF) <35 %. This is largely based on studies using echocardiography. Cardiac magnetic resonance imaging (CMR) is increasingly utilised for LVEF assessment, but several studies have shown differences between LVEF assessed by CMR and echocardiography. The present study compared LVEF assessment by CMR and echocardiography in a heart failure population and evaluated effects on eligibility for device therapy. METHODS: 152 patients (106 male, mean age 65.5 ± 9.9 years) referred for device therapy were included. During evaluation of eligibility they underwent both CMR and echocardiographic LVEF assessment. CMR volumes were computed from a stack of short-axis images. Echocardiographic volumes were computed using Simpson's biplane method. RESULTS: The study population demonstrated an underestimation of end-diastolic volume (EDV) and end-systolic volume (ESV) by echocardiography of 71 ± 53 ml (mean ± SD) and 70 ± 49 ml, respectively. This resulted in an overestimation of LVEF of 6.6 ± 8.3 % by echocardiography compared with CMR (echocardiographic LVEF 31.5 ± 8.7 % and CMR LVEF 24.9 ± 9.6 %). 28 % of patients had opposing outcomes of eligibility for cardiac device therapy depending on the imaging modality used. CONCLUSION: We found EDV and ESV to be underestimated by echocardiography, and LVEF assessed by CMR to be significantly smaller than by echocardiography. Applying an LVEF cut-off value of 35 %, CMR would significantly increase the number of patients eligible for device implantation. Therefore, LVEF cut-off values might need reassessment when using CMR.

14.
Phys Rev E ; 109(2-2): 025204, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38491565

RESUMEN

In this work we present the design of the first controlled fusion laboratory experiment to reach target gain G>1 N221204 (5 December 2022) [Phys. Rev. Lett. 132, 065102 (2024)10.1103/PhysRevLett.132.065102], performed at the National Ignition Facility, where the fusion energy produced (3.15 MJ) exceeded the amount of laser energy required to drive the target (2.05 MJ). Following the demonstration of ignition according to the Lawson criterion N210808, experiments were impacted by nonideal experimental fielding conditions, such as increased (known) target defects that seeded hydrodynamic instabilities or unintentional low-mode asymmetries from nonuniformities in the target or laser delivery, which led to reduced fusion yields less than 1 MJ. This Letter details design changes, including using an extended higher-energy laser pulse to drive a thicker high-density carbon (also known as diamond) capsule, that led to increased fusion energy output compared to N210808 as well as improved robustness for achieving high fusion energies (greater than 1 MJ) in the presence of significant low-mode asymmetries. For this design, the burnup fraction of the deuterium and tritium (DT) fuel was increased (approximately 4% fuel burnup and a target gain of approximately 1.5 compared to approximately 2% fuel burnup and target gain approximately 0.7 for N210808) as a result of increased total (DT plus capsule) areal density at maximum compression compared to N210808. Radiation-hydrodynamic simulations of this design predicted achieving target gain greater than 1 and also the magnitude of increase in fusion energy produced compared to N210808. The plasma conditions and hotspot power balance (fusion power produced vs input power and power losses) using these simulations are presented. Since the drafting of this manuscript, the results of this paper have been replicated and exceeded (N230729) in this design, together with a higher-quality diamond capsule, setting a new record of approximately 3.88MJ of fusion energy and fusion energy target gain of approximately 1.9.

15.
Phys Rev Lett ; 110(7): 075001, 2013 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-25166377

RESUMEN

The sensitivity of inertial confinement fusion implosions, of the type performed on the National Ignition Facility (NIF) [1], to low-mode flux asymmetries is investigated numerically. It is shown that large-amplitude, low-order mode shapes (Legendre polynomial P(4), resulting from low-order flux asymmetries, cause spatial variations in capsule and fuel momentum that prevent the deuterium and tritium (DT) "ice" layer from being decelerated uniformly by the hot spot pressure. This reduces the transfer of implosion kinetic energy to internal energy of the central hot spot, thus reducing the neutron yield. Furthermore, synthetic gated x-ray images of the hot spot self-emission indicate that P(4) shapes may be unquantifiable for DT layered capsules. Instead the positive P(4) asymmetry "aliases" itself as an oblate P(2) in the x-ray images. Correction of this apparent P(2) distortion can further distort the implosion while creating a round x-ray image. Long wavelength asymmetries may be playing a significant role in the observed yield reduction of NIF DT implosions relative to detailed postshot two-dimensional simulations.

16.
Phys Rev Lett ; 111(4): 045001, 2013 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-23931375

RESUMEN

Mixing of plastic ablator material, doped with Cu and Ge dopants, deep into the hot spot of ignition-scale inertial confinement fusion implosions by hydrodynamic instabilities is diagnosed with x-ray spectroscopy on the National Ignition Facility. The amount of hot-spot mix mass is determined from the absolute brightness of the emergent Cu and Ge K-shell emission. The Cu and Ge dopants placed at different radial locations in the plastic ablator show the ablation-front hydrodynamic instability is primarily responsible for hot-spot mix. Low neutron yields and hot-spot mix mass between 34(-13,+50) ng and 4000(-2970,+17 160) ng are observed.

17.
Phys Rev Lett ; 111(8): 085004, 2013 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-24010449

RESUMEN

Deuterium-tritium inertial confinement fusion implosion experiments on the National Ignition Facility have demonstrated yields ranging from 0.8 to 7×10(14), and record fuel areal densities of 0.7 to 1.3 g/cm2. These implosions use hohlraums irradiated with shaped laser pulses of 1.5-1.9 MJ energy. The laser peak power and duration at peak power were varied, as were the capsule ablator dopant concentrations and shell thicknesses. We quantify the level of hydrodynamic instability mix of the ablator into the hot spot from the measured elevated absolute x-ray emission of the hot spot. We observe that DT neutron yield and ion temperature decrease abruptly as the hot spot mix mass increases above several hundred ng. The comparison with radiation-hydrodynamic modeling indicates that low mode asymmetries and increased ablator surface perturbations may be responsible for the current performance.

18.
Phys Rev Lett ; 111(21): 215001, 2013 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-24313493

RESUMEN

Radiation-driven, low-adiabat, cryogenic DT layered plastic capsule implosions were carried out on the National Ignition Facility (NIF) to study the sensitivity of performance to peak power and drive duration. An implosion with extended drive and at reduced peak power of 350 TW achieved the highest compression with fuel areal density of ~1.3±0.1 g/cm2, representing a significant step from previously measured ~1.0 g/cm2 toward a goal of 1.5 g/cm2. Future experiments will focus on understanding and mitigating hydrodynamic instabilities and mix, and improving symmetry required to reach the threshold for thermonuclear ignition on NIF.

19.
Brain Behav Immun ; 33: 57-64, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23727274

RESUMEN

Fatigue in the immune mediated inflammatory disease sarcoidosis is thought to be associated with impaired exercise tolerance. This prospective study assessed fatigue and recuperative capacity after repeated exercise, and examined whether changing concentrations in biomarkers upon exercise are associated with fatigue. Twenty sarcoidosis patients and 10 healthy volunteers performed maximal cardiopulmonary exercise tests on two successive days. Concentrations of cytokines, stress hormones, ACE and CK were assessed before and after the two exercise tests, and 3 days thereafter. All participants completed a sleep diary. Severely fatigued patients showed significant lower VO2 max (p=0.038, p=0.022) and maximal workload (p=0.034, p=0.028) on both exercise tests compared to healthy controls. No impairment of maximal exercise testing was demonstrated during the second cycling test in any group. Fatigue was not correlated with changes in concentrations of biomarkers upon exercise. Severely fatigued patients rated both tests as significantly more fatiguing, and reported significant lower mean subjective night sleeping time during the testing period. Fatigue in sarcoidosis patients cannot be objectified by reduction of exercise capacity after repeated maximal exercise testing, and is not correlated with significant changes in biomarkers. Severe fatigue is only and consistently featured by patient reported outcomes.


Asunto(s)
Prueba de Esfuerzo/efectos adversos , Prueba de Esfuerzo/métodos , Fatiga/diagnóstico , Fatiga/etiología , Sarcoidosis Pulmonar/complicaciones , Adolescente , Adulto , Anciano , Biomarcadores/metabolismo , Estudios de Cohortes , Tolerancia al Ejercicio/inmunología , Fatiga/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Intercambio Gaseoso Pulmonar/inmunología , Recuperación de la Función/inmunología , Pruebas de Función Respiratoria/efectos adversos , Sarcoidosis Pulmonar/inmunología , Sarcoidosis Pulmonar/fisiopatología , Prevención Secundaria , Autoinforme , Índice de Severidad de la Enfermedad , Adulto Joven
20.
Phys Rev E ; 108(5): L053203, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38115512

RESUMEN

Inertial confinement fusion ignition requires high inflight shell velocity, good energy coupling between the hotspot and shell, and high areal density at peak compression. Three-dimensional asymmetries caused by imperfections in the drive symmetry or target can grow and damage the coupling and confinement. Recent high-yield experiments have shown that low-mode asymmetries are a key degradation mechanism and contribute to variability. We show the experimental signatures and impacts of asymmetry change with increasing implosion yield given the same initial cause. This letter has implications for improving robustness to a key degradation in ignition experiments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA