Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-36343007

RESUMEN

In atherosclerosis, low wall shear stress (WSS) is known to favor plaque development, while high WSS increases plaque rupture risk. To improve plaque diagnostics, WSS monitoring is crucial. Here, we propose wall shear imaging (WASHI), a noninvasive contrast-free framework that leverages high-frame-rate ultrasound (HiFRUS) to map the wall shear rate (WSR) that relates to WSS by the blood viscosity coefficient. Our method measures WSR as the tangential flow velocity gradient along the arterial wall from the flow vector field derived using a multi-angle vector Doppler technique. To improve the WSR estimation performance, WASHI semiautomatically tracks the wall position throughout the cardiac cycle. WASHI was first evaluated with an in vitro linear WSR gradient model; the estimated WSR was consistent with theoretical values (an average error of 4.6% ± 12.4 %). The framework was then tested on healthy and diseased carotid bifurcation models. In both scenarios, key spatiotemporal dynamics of WSR were noted: 1) oscillating shear patterns were present in the carotid bulb and downstream to the internal carotid artery (ICA) where retrograde flow occurs; and 2) high WSR was observed particularly in the diseased model where the measured WSR peaked at 810 [Formula: see text] due to flow jetting. We also showed that WASHI could consistently track arterial wall motion to map its WSR. Overall, WASHI enables high temporal resolution mapping of WSR that could facilitate investigations on causal effects between WSS and atherosclerosis.


Asunto(s)
Aterosclerosis , Placa Aterosclerótica , Humanos , Ultrasonografía/métodos , Arterias Carótidas/diagnóstico por imagen , Viscosidad Sanguínea , Estrés Mecánico , Velocidad del Flujo Sanguíneo , Resistencia al Corte , Modelos Cardiovasculares
2.
Med Phys ; 46(7): 3034-3043, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31049993

RESUMEN

PURPOSE: Assessment of urethral dynamics is clinically regarded to be important in analyzing the functional impact of pathological features like urethral obstruction, albeit it is difficult to perform directly in vivo. To facilitate such an assessment, urethra phantoms may serve well as investigative tools by reconstructing urethral dynamics based on anthropomorphic factors. Here, our aim is to design a new class of anatomically realistic, deformable urethra phantoms that can simulate the geometric, mechanical, and hydrodynamic characteristics of the male prostatic urethra. METHODS: A new lost-core tube casting protocol was devised. It first involved the drafting of urethra geometry in computer-aided design software. Next, 3D printing was used to fabricate the urethra geometry and an outer mold. These parts were then used to cast a urinary tract using a polyvinyl alcohol (PVA)-based material (with 26.6 ± 4.0 kPa Young's elastic modulus). After forming a surrounding tissue-mimicking slab using an agar-gelatin mixture (with 17.4 ± 3.4 kPa Young's modulus), the completed urethra phantom was connected to a flow circuit that simulates voiding. To assess the fabricated phantoms' morphology, ultrasound imaging was performed over different planes. Also, color Doppler imaging was performed to visualize the flow profile within the urinary tract. RESULTS: Deformable phantoms were devised for the normal urethra and a diseased urethra with obstruction due to benign prostatic hyperplasia (BPH). During voiding, the short-axis lumen diameter at the verumontanum of the BPH-featured phantom (0.91 ± 0.08 mm) was significantly smaller than that for the normal phantom (2.49 ± 0.20 mm). Also, the maximum flow velocity of the BPH-featured phantom (59.3 ± 5.8 cm/s; without Doppler angle correction) was found to be higher than that of the normal phantom (22.7 ± 9.0 cm/s). CONCLUSION: The fabricated phantoms were effective in simulating urethra deformation resulting from urine passage during voiding. They can be used for mechanistic studies of urethral dynamics and for the testing of urodynamic diagnostic techniques in urology.


Asunto(s)
Fantasmas de Imagen , Próstata/fisiología , Urodinámica , Fenómenos Biomecánicos , Humanos , Masculino , Próstata/diagnóstico por imagen , Próstata/fisiopatología , Hiperplasia Prostática/diagnóstico por imagen , Hiperplasia Prostática/patología , Hiperplasia Prostática/fisiopatología , Ultrasonografía , Uretra/diagnóstico por imagen , Uretra/patología , Uretra/fisiopatología , Sistema Urinario/anatomía & histología , Sistema Urinario/diagnóstico por imagen , Sistema Urinario/patología
3.
Ultrasound Med Biol ; 44(4): 872-883, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29361372

RESUMEN

Regional wall stiffening and thickening are two common pathological features of arteries. To account for these two features, we developed a new arterial phantom design framework to facilitate the development of vessel models that contain a lesion segment whose wall stiffness and thickness differ from those of other segments. This new framework is based on multi-part injection molding principles that sequentially casted the lesion segment and the flank segments of the vessel model using molding parts devised with computer-aided design tools. The vessel-mimicking material is created from polyvinyl alcohol cryogel, and its acoustic properties are similar to those of arteries. As a case demonstration, we fabricated a stenosed three-segment phantom composed of a central lesion segment (5.1-mm diameter, 1.95-mm wall thickness, 212.6-kPa elastic modulus) and two flank segments (6.0-mm diameter, 1.5-mm wall thickness, 133.7-kPa elastic modulus). B-mode imaging confirmed the difference in thickness between the lesion segment and flank segments of the phantom. Also, Doppler-based vessel wall displacement analysis revealed that when pulsatile flow was fed through the phantom (carotid pulse; 27 mL/s peak flow rate), the lesion segment distended less compared with the flank segments. Specifically, the three-beat averaged peak wall displacement in the lesion segment was measured as 0.28 mm, and it was significantly smaller than that of the flank segments (0.60 mm). It is anticipated that this new multi-segment arterial phantom can serve as a performance testbed for the evaluation of local arterial stiffness estimation algorithms.


Asunto(s)
Criogeles , Fantasmas de Imagen , Alcohol Polivinílico , Ultrasonografía/métodos , Rigidez Vascular , Velocidad del Flujo Sanguíneo
4.
Artículo en Inglés | MEDLINE | ID: mdl-27959808

RESUMEN

Flow phantoms with anatomically realistic geometry and high acoustic compatibility are valuable investigative tools in vascular ultrasound studies. Here, we present a new framework to fabricate ultrasound-compatible flow phantoms to replicate human vasculature that is tortuous, nonplanar, and branching in nature. This framework is based upon the integration of rapid prototyping and investment casting principles. A pedagogical walkthrough of our engineering protocol is presented in this paper using a patient-specific cerebral aneurysm model as an exemplar demonstration. The procedure for constructing the flow circuit component of the phantoms is also presented, including the design of a programmable flow pump system, the fabrication of blood mimicking fluid, and flow rate calibration. Using polyvinyl alcohol cryogel as the tissue mimicking material, phantoms developed with the presented protocol exhibited physiologically relevant acoustic properties [attenuation coefficient: 0.229±0.032 dB/( [Formula: see text]) and acoustic speed: 1535±2.4 m/s], and their pulsatile flow dynamics closely resembled the flow profile input. As a first application of our developed phantoms, the flow pattern of the patient-specific aneurysm model was visualized by performing high-frame-rate color-encoded speckle imaging over multiple time-synchronized scan planes. Persistent recirculation was observed, and the vortex center was found to shift in position over a cardiac cycle, indicating the 3-D nature of flow recirculation inside an aneurysm. These findings suggest that phantoms produced from our reported protocol can serve well as acoustically compatible test beds for vascular ultrasound studies, including 3-D flow imaging.


Asunto(s)
Modelos Cardiovasculares , Modelación Específica para el Paciente , Fantasmas de Imagen , Velocidad del Flujo Sanguíneo/fisiología , Criogeles , Femenino , Humanos , Imagenología Tridimensional , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/patología , Aneurisma Intracraneal/fisiopatología , Persona de Mediana Edad , Alcohol Polivinílico , Ultrasonografía Doppler
5.
Artículo en Inglés | MEDLINE | ID: mdl-27429436

RESUMEN

As a major application domain of vascular ultrasound, the carotid artery has long been the subject of anthropomorphic phantom design. It is nevertheless not trivial to develop walled carotid phantoms that are compatible for use in integrative imaging of carotid wall motion and flow dynamics. In this paper, we present a novel phantom design protocol that can enable efficient fabrication of walled carotid bifurcation phantoms with: (i) high acoustic compatibility, (ii) artery-like vessel elasticity, and (iii) stenotic narrowing feature. Our protocol first involved direct fabrication of the vessel core and an outer mold using computer-aided design tools and 3-D printing technology; these built parts were then used to construct an elastic vessel tube through investment casting of a polyvinyl alcohol containing mixture, and an agar-gelatin tissue mimicking slab was formed around the vessel tube. For demonstration, we applied our protocol to develop a set of healthy and stenosed (25%, 50%, 75%) carotid bifurcation phantoms. Plane wave imaging experiments were performed on these phantoms using an ultrasound scanner with channel-level configurability. Results show that the wall motion dynamics of our phantoms agreed with pulse wave propagation in an elastic vessel (pulse wave velocity of 4.67±0.71 m/s measured at the common carotid artery), and their flow dynamics matched the expected ones in healthy and stenosed bifurcation (recirculation and flow jet formation observed). Integrative imaging of vessel wall motion and blood flow dynamics in our phantoms was also demonstrated, from which we observed fluid-structure interaction differences between healthy and diseased bifurcation phantoms. These findings show that the walled bifurcation phantoms developed with our new protocol are useful in vascular imaging studies that individually or jointly assess wall motion and flow dynamics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA