BMC Anesthesiol ; 24(1): 233, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38992570

RESUMEN

BACKGROUND: Remimazolam is a relatively new benzodiazepine with growing use in procedural sedation and general anaesthesia. Initiated by case reports, the physical incompatibility of remimazolam with ringer's acetated and ringer's lactated solution has been reported. More recently, remifentanil, fentanyl, rocuronium, vecuronium, dexmedetomidine, and midazolam, have been investigated and suggested safe for coadministration with remimazolam. Apart from case reports, incompatibility for other frequently used drugs remains unknown. METHODS: Sixty-five drugs and intravenous fluids were tested for possible precipitation with remimazolam in a simulated y-site administration. Equal volumes of the test drug were injected into the remimazolam solution, examined and photo documented at 1, 15, 30 and 60 min after mixture. Examination was taken by two independent investigators. pH was measured before, and 60 min after mixing the drugs. RESULTS: Seventeen (26.15%) drugs or fluids showed precipitation, 47 (72.31%) did not show any sign of interaction. Propofol could not be assessed, because of the turbidity of the substance itself. Precipitation occurred immediately and remained stable in all timestamps. The incompatible drug-remimazolam-mixtures had a median pH of 7.15 (6.67, 8.01), the non-precipitating mixtures a median pH of 4.75 (3.8, 5.6). The pH-values of both groups were significantly different (Mann-Whitney-U-test; p < .00001). There is an increasing risk for precipitation with more basic baseline pH-levels of the tested drug. No interaction was seen in baseline pH below 5. CONCLUSIONS: Remimazolam (Byfavo®) is incompatible with ampicillin/ sulbactam, calcium gluconate, clindamycin, dexamethasone, dimenhydrinate, an 148mval/l electrolyte - glucose 1% solution (E148G1®), furosemide, a 4% gelatine volume expander (gelafundin®), heparin sodium, insulin, meropenem, sodium bicarbonate 8.4%, prednisolone, the crystalloid infusions jonosteril® and sterofundin®, thiopental and tranexamic acid. The results strongly affirm remimazolam's safety requirements: A separate line for remimazolam and an approved compatible baseline infusion is mandatory and an alternative way to administer bolus medication is required.


Asunto(s)
Benzodiazepinas , Incompatibilidad de Medicamentos , Hipnóticos y Sedantes , Benzodiazepinas/administración & dosificación , Humanos , Hipnóticos y Sedantes/administración & dosificación , Concentración de Iones de Hidrógeno , Atención Perioperativa/métodos
2.
J Sleep Res ; 31(6): e13615, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35474362

RESUMEN

Modulation of slow-wave activity, either via pharmacological sleep induction by administering sodium oxybate or sleep restriction followed by a strong dissipation of sleep pressure, has been associated with preserved posttraumatic cognition and reduced diffuse axonal injury in traumatic brain injury rats. Although these classical strategies provided promising preclinical results, they lacked the specificity and/or translatability needed to move forward into clinical applications. Therefore, we recently developed and implemented a rodent auditory stimulation method that is a scalable, less invasive and clinically meaningful approach to modulate slow-wave activity by targeting a particular phase of slow waves. Here, we assessed the feasibility of down-phase targeted auditory stimulation of slow waves and evaluated its comparative modulatory strength in relation to the previously employed slow-wave activity modulators in our rat model of traumatic brain injury. Our results indicate that, in spite of effectively reducing slow-wave activity in both healthy and traumatic brain injury rats via down-phase targeted stimulation, this method was not sufficiently strong to counteract the boost in slow-wave activity associated with classical modulators, nor to alter concomitant posttraumatic outcomes. Therefore, the usefulness and effectiveness of auditory stimulation as potential standalone therapeutic strategy in the context of traumatic brain injury warrants further exploration.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Sueño , Animales , Ratas , Estimulación Acústica/métodos , Cognición , Lesiones Traumáticas del Encéfalo/complicaciones , Electroencefalografía/métodos
3.
BMC Anesthesiol ; 22(1): 88, 2022 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-35361115

RESUMEN

BACKGROUND: A peripheral venous catheter (PVC) is the most widely used device for obtaining vascular access, allowing the administration of fluids and medication. Up to 25% of adult patients, and 50% of pediatric patients experience a first-attempt cannulation failure. In addition to patient and clinician characteristics, device features might affect the handling and success rates. The objective of the study was to compare the first-attempt cannulation success rate between PVCs with wings and a port access (Vasofix® Safety, B. Braun, abbreviated hereon in as VS) with those without (Introcan® Safety, B. Braun, abbreviated hereon in as IS) in an anesthesiological cohort. METHODS: An open label, multi-center, randomized trial was performed. First-attempt cannulation success rates were examined, along with relevant patient, clinician, and device characteristics with univariate and multivariate analyses. Information on handling and adherence to use instructions was gathered, and available catheters were assessed for damage. RESULTS: Two thousand three hundred four patients were included in the intention to treat analysis. First-attempt success rate was significantly higher with winged and ported catheters (VS) than with the non-winged, non-ported design (IS) (87.5% with VS vs. 78.2% with IS; PChi < .001). Operators rated the handling of VS as superior (rating of "good" or "very good: 86.1% VS vs. 20.8% IS, PChi < .001). Reinsertion of the needle into the catheter after partial withdrawal-prior or during the catheterization attempt-was associated with an increased risk of cannulation failure (7.909, CI 5.989-10.443, P < .001 and 23.023, CI 10.372-51.105, P < .001, respectively) and a twofold risk of catheter damage (OR 1.999, CI 1.347-2.967, P = .001). CONCLUSIONS: First-attempt cannulation success of peripheral, ported, winged catheters was higher compared to non-ported, non-winged devices. The handling of the winged and ported design was better rated by the clinicians. Needle reinsertions are related to an increase in rates of catheter damage and cannulation failure. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT02213965 , Date: 12/08/2014.


Asunto(s)
Cateterismo , Pacientes , Adulto , Catéteres , Niño , Humanos , Inyecciones
4.
Crit Care ; 25(1): 295, 2021 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-34404458

RESUMEN

BACKGROUND: Intensive Care Resources are heavily utilized during the COVID-19 pandemic. However, risk stratification and prediction of SARS-CoV-2 patient clinical outcomes upon ICU admission remain inadequate. This study aimed to develop a machine learning model, based on retrospective & prospective clinical data, to stratify patient risk and predict ICU survival and outcomes. METHODS: A Germany-wide electronic registry was established to pseudonymously collect admission, therapeutic and discharge information of SARS-CoV-2 ICU patients retrospectively and prospectively. Machine learning approaches were evaluated for the accuracy and interpretability of predictions. The Explainable Boosting Machine approach was selected as the most suitable method. Individual, non-linear shape functions for predictive parameters and parameter interactions are reported. RESULTS: 1039 patients were included in the Explainable Boosting Machine model, 596 patients retrospectively collected, and 443 patients prospectively collected. The model for prediction of general ICU outcome was shown to be more reliable to predict "survival". Age, inflammatory and thrombotic activity, and severity of ARDS at ICU admission were shown to be predictive of ICU survival. Patients' age, pulmonary dysfunction and transfer from an external institution were predictors for ECMO therapy. The interaction of patient age with D-dimer levels on admission and creatinine levels with SOFA score without GCS were predictors for renal replacement therapy. CONCLUSIONS: Using Explainable Boosting Machine analysis, we confirmed and weighed previously reported and identified novel predictors for outcome in critically ill COVID-19 patients. Using this strategy, predictive modeling of COVID-19 ICU patient outcomes can be performed overcoming the limitations of linear regression models. Trial registration "ClinicalTrials" (clinicaltrials.gov) under NCT04455451.


Asunto(s)
COVID-19/epidemiología , Enfermedad Crítica/epidemiología , Registros Electrónicos de Salud/estadística & datos numéricos , Unidades de Cuidados Intensivos , Aprendizaje Automático , Adulto , Anciano , COVID-19/terapia , Estudios de Cohortes , Enfermedad Crítica/terapia , Servicio de Urgencia en Hospital , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud
5.
Cereb Cortex Commun ; 1(1): tgaa032, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-34296105

RESUMEN

Only a small proportion of what we see can later be recalled. Up to date it is unknown how far differences in visual exploration during encoding affect the strength of episodic memories. Here, we identified individual gaze characteristics by analyzing eye tracking data in a picture encoding task performed by 967 healthy subjects during fMRI. We found a positive correlation between fixation frequency during visual exploration and subsequent free recall performance. Brain imaging results showed a positive correlation of fixation frequency with activations in regions related to vision and memory, including the medial temporal lobe. To investigate if higher fixation frequency is causally linked to better memory, we experimentally manipulated visual exploration patterns in an independent population of 64 subjects. Doubling the number of fixations within a given exploration time increased subsequent free recall performance by 19%. Our findings provide evidence for a causal relationship between fixation frequency and episodic memory for visual information.