PLoS One ; 10(2): e0116907, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25723187

RESUMEN

PURPOSE: To experimentally validate a non-linear finite element analysis (FEA) modeling approach assessing in-vitro fracture risk at the proximal femur and to transfer the method to standard in-vivo multi-detector computed tomography (MDCT) data of the hip aiming to predict additional hip fracture risk in subjects with and without osteoporosis associated vertebral fractures using bone mineral density (BMD) measurements as gold standard. METHODS: One fresh-frozen human femur specimen was mechanically tested and fractured simulating stance and clinically relevant fall loading configurations to the hip. After experimental in-vitro validation, the FEA simulation protocol was transferred to standard contrast-enhanced in-vivo MDCT images to calculate individual hip fracture risk each for 4 subjects with and without a history of osteoporotic vertebral fractures matched by age and gender. In addition, FEA based risk factor calculations were compared to manual femoral BMD measurements of all subjects. RESULTS: In-vitro simulations showed good correlation with the experimentally measured strains both in stance (R2 = 0.963) and fall configuration (R2 = 0.976). The simulated maximum stress overestimated the experimental failure load (4743 N) by 14.7% (5440 N) while the simulated maximum strain overestimated by 4.7% (4968 N). The simulated failed elements coincided precisely with the experimentally determined fracture locations. BMD measurements in subjects with a history of osteoporotic vertebral fractures did not differ significantly from subjects without fragility fractures (femoral head: p = 0.989; femoral neck: p = 0.366), but showed higher FEA based risk factors for additional incident hip fractures (p = 0.028). CONCLUSION: FEA simulations were successfully validated by elastic and destructive in-vitro experiments. In the subsequent in-vivo analyses, MDCT based FEA based risk factor differences for additional hip fractures were not mirrored by according BMD measurements. Our data suggests, that MDCT derived FEA models may assess bone strength more accurately than BMD measurements alone, providing a valuable in-vivo fracture risk assessment tool.


Asunto(s)
Fémur/diagnóstico por imagen , Fémur/fisiología , Fenómenos Mecánicos , Modelos Teóricos , Tomografía Computarizada por Rayos X/métodos , Absorciometría de Fotón , Anciano , Densidad Ósea , Estudios de Casos y Controles , Simulación por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA