Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Biomacromolecules ; 25(7): 4428-4439, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38917058

RESUMEN

Carbonyl cross-linkers are used to modify textiles and form resins, and are produced annually in megatonne volumes. Due to their toxicity toward the environment and human health, however, less harmful biobased alternatives are needed. This study introduces carbonyl groups to lactose and galactose using galactose oxidase from Fusarium graminearum (FgrGalOx) and pyranose dehydrogenase from Agaricus bisporus (AbPDH1) to produce four cross-linkers. Differential scanning calorimetry was used to compare cross-linker reactivity, most notably resulting in a 34 °C decrease in reaction peak temperature (72 °C) for FgrGalOx-oxidized galactose compared to unmodified galactose. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy, X-ray photoelectron spectroscopy (XPS), and proton nuclear magnetic resonance (1H NMR) spectroscopy were used to verify imine formation and amine and aldehyde depletion. Cross-linkers were shown to form gels when mixed with polyallylamine, with FgrGalOx-oxidized lactose forming gels more effectively than all other cross-linkers, including glutaraldehyde. Further development of carbohydrate cross-linker technologies could lead to their adoption in various applications, including in adhesives, resins, and textiles.


Asunto(s)
Reactivos de Enlaces Cruzados , Oxidación-Reducción , Poliaminas , Reactivos de Enlaces Cruzados/química , Poliaminas/química , Galactosa Oxidasa/química , Galactosa Oxidasa/metabolismo , Galactosa/química , Lactosa/química , Agaricus/química , Carbohidratos/química
2.
BMC Ophthalmol ; 24(1): 200, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38679743

RESUMEN

BACKGROUND: To report a case of central retinal artery occlusion (CRAO) after intravitreal injection of brolucizumab for a treatment-naïve neovascular age-related macular degeneration (nAMD) patient without comorbid cardiovascular disease history. CASE PRESENTATION: A 79-year-old Asian male without a cardiovascular disease history such as diabetes or hypertension underwent three times of monthly consecutive intravitreal brolucizumab injections for treatment of progressed nAMD in his left eye. Two days after the third injection, the patient presented with acute painless visual loss. Typical retinal whitening with a cherry red spot was observed on the fundus photograph, and retinal swelling with hyper-reflectivity was also identified on the optical coherence tomography (OCT) scan. On the fundus fluorescein angiography, arm-to-retina time and arteriovenous transit time were remarkedly delayed, but clinical findings suggesting an intraocular inflammation (IOI) were not observed. Therefore, CRAO was diagnosed, and anterior chamber paracentesis was administrated immediately. However, there had been no improvement in visual acuity during the follow-up period of three months, despite prolonged oral steroid and anti-platelet agent medication. CONCLUSIONS: In rare cases, patients without cardiovascular comorbidities can develop CRAO after intravitreal brolucizumab injection without gross evidence of IOI. Therefore, CRAO should always be in consideration and careful observation is required after intravitreal brolucizumab injection for nAMD patients with old age, even if the patient does not have any other cardiovascular disease history.


Asunto(s)
Inhibidores de la Angiogénesis , Anticuerpos Monoclonales Humanizados , Inyecciones Intravítreas , Oclusión de la Arteria Retiniana , Tomografía de Coherencia Óptica , Humanos , Masculino , Anciano , Oclusión de la Arteria Retiniana/inducido químicamente , Oclusión de la Arteria Retiniana/diagnóstico , Inhibidores de la Angiogénesis/efectos adversos , Inhibidores de la Angiogénesis/administración & dosificación , Anticuerpos Monoclonales Humanizados/efectos adversos , Anticuerpos Monoclonales Humanizados/uso terapéutico , Anticuerpos Monoclonales Humanizados/administración & dosificación , Angiografía con Fluoresceína , Degeneración Macular Húmeda/tratamiento farmacológico , Degeneración Macular Húmeda/diagnóstico , Agudeza Visual
3.
Vet Med (Praha) ; 67(12): 644-650, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38623307

RESUMEN

An 11-year-old spayed female Toy Poodle presented with acute tetraparesis. A small subcutaneous mass was found in the right trunk region, and the magnetic resonance revealed a compressive spinal cord lesion due to an irregular bone proliferation at the third cervical vertebra. After surgical resection of the vertebral lesion, the neurological symptoms improved, and the patient could walk on her own. The excised vertebral and subcutaneous masses were diagnosed as a mammary adenocarcinoma on the histopathological examination, with Ki-67 and HER-2 immunohistochemistry staining. This case report highlights the importance of defining the primary tumours of metastatic vertebral tumours and the necessity of palliative surgery to improve the patient's quality of life.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38774957

RESUMEN

OBJECTIVE: Cochlear implant (CI) electrode design has changed over time. Changes in intracochlear electrode design might influence the spread of neural activation along the auditory nerve and the number of independent channels. This study aimed to investigate the impact of intracochlear electrode design on the electrode-neuron interface using electrophysiological measures. STUDY DESIGN: Prospective cohort study. SETTING: A single tertiary hospital. METHODS: Fifty-two ears who were implanted with CI divided into 3 groups based on the design of intracochlear electrode arrays. Twenty-three ears were implanted with lateral wall straight electrodes. Eighteen ears were implanted with the slim perimodiolar electrode, and 11 ears were implanted with the old perimodiolar electrode. Various electrically-evoked compound action potential (ECAP) metrics were measured to quantify spread of excitation and channel interaction. RESULTS: ECAP threshold and slope were not significantly different among groups. ECAP spread of excitation (SOE) half-width and channel interaction index (CII) were significantly larger in subjects implanted with the lateral wall straight electrodes, indicating a wider spread of excitation compared to those with perimodiolar electrodes. Electrode impedance was significantly lower in subjects implanted with perimodiolar electrodes than those with lateral wall electrodes. CONCLUSION: Perimodiolar electrode groups yielded significantly narrower SOE half-widths and smaller CII than the lateral wall straight electrode group. This may indicate that the electrode array that hugged the modiolus had less overlap in neural excitation between adjacent electrodes, resulting in reduced channel interaction and potentially better spectral resolution than the electrode array positioned more laterally.

5.
J Audiol Otol ; 28(3): 195-202, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38685834

RESUMEN

BACKGROUND AND OBJECTIVES: The temporal structure of sound, characterized by regular patterns, plays a crucial role in optimizing the processing of auditory information. The meter, representing a well-organized sequence of evenly spaced beats in music, exhibits a hierarchical arrangement, with stronger beats occupying higher metrical positions. Moreover, the meter has been shown to influence behavioral and neural processing, particularly the N1, P2, and mismatch negativity components. However, the role of the P1 component in the context of metrical hierarchy remains unexplored. This study aimed to investigate the effects of metrical hierarchy on the P1 component and compare the responses between musicians and non-musicians. SUBJECTS AND METHODS: Thirty participants (15 musicians and 15 non-musicians) were enrolled in the study. Auditory stimuli consisted of a synthesized speech syllable presented together with a repeating series of four tones, establishing a quadruple meter. Electrophysiological recordings were performed to measure the P1 component. RESULTS: The results revealed that metrical position had a significant effect on P1 amplitude, with the strongest beat showing the lowest amplitude. This contrasts with previous findings, in which enhanced P1 responses were typically observed at on-the-beat positions. The reduced P1 response on the strong beat can be interpreted within the framework of predictive coding and temporal prediction, where a higher predictability of pitch changes at the strong beat leads to a reduction in the P1 response. Furthermore, higher P1 amplitudes were observed in musicians compared to non-musicians, suggesting that musicians have enhanced sensory processing. CONCLUSIONS: This study demonstrates the effects of metrical hierarchy on the P1 component, thereby enriching our understanding of auditory processing. The results suggest that predictive coding and temporal prediction play important roles in shaping sensory processing. Further, they suggest that musical training may enhance P1 responses.

6.
J Audiol Otol ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38973325

RESUMEN

Background and Objectives: : Wireless streaming technology (WT), designed to transmit sounds directly from a mobile phone to hearing aids, was developed to enhance the signal-to-noise ratio. However, the advantages of WT during phone use and the specific demographic that can fully benefit from this technology has not been thoroughly evaluated. We aimed to investigate the benefits and identify predictive factors associated with bilateral wireless streaming among hearing aid users. Subjects and Methods: : Eighteen adults with symmetrical, bilateral hearing loss participated in the study. To assess the benefits of wireless streaming during phone use, researchers assessed sentence/word recognition and listening effort in two scenarios: a noisy background with WT turned "OFF" or "ON." Listening effort was evaluated through self-reported measurements. Cognitive function was also assessed using the Montreal Cognitive Assessment (MoCA) score. Results: : Participant mean age was 57.3 years (range 27-70), and the mean MoCA score was 27.0 (23-30). The activation of WT demonstrated a significant improvement in the sentence/word recognition test and reduced listening effort. The MoCA score showed a significant correlation with WT (ρ=0.59, p=0.01), suggesting a positive association between cognitive function and the benefits of WT. Conclusions: : Bilateral wireless streaming may enhance sentence/word recognition and reduce listening effort during phone use in hearing aid users, with these benefits potentially linked to cognitive function.

7.
Braz. j. otorhinolaryngol. (Impr.) ; 85(5): 571-577, Sept.-Oct. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1039292

RESUMEN

Abstract Introduction: Despite recent advancement in the prediction of cochlear implant outcome, the benefit of bilateral procedures compared to bimodal stimulation and how we predict speech perception outcomes of sequential bilateral cochlear implant based on bimodal auditory performance in children remain unclear. Objectives: This investigation was performed: (1) to determine the benefit of sequential bilateral cochlear implant and (2) to identify the associated factors for the outcome of sequential bilateral cochlear implant. Methods: Observational and retrospective study. We retrospectively analyzed 29 patients with sequential cochlear implant following bimodal-fitting condition. Audiological evaluations were performed; the categories of auditory performance scores, speech perception with monosyllable and disyllables words, and the Korean version of Ling. Audiological evaluations were performed before sequential cochlear implant with the bimodal fitting condition (CI1 + HA) and one year after the sequential cochlear implant with bilateral cochlear implant condition (CI1 + CI2). The good performance group (GP) was defined as follows; 90% or higher in monosyllable and bisyllable tests with auditory-only condition or 20% or higher improvement of the scores with CI1 + CI2. Age at first implantation, inter-implant interval, categories of auditory performance score, and various comorbidities were analyzed by logistic regression analysis. Results: Compared to the CI1 + HA, CI1 + CI2 provided significant benefit in categories of auditory performance, speech perception, and Korean version of Ling results. Preoperative categories of auditory performance scores were the only associated factor for being GP (odds ratio = 4.38, 95% confidence interval - 95% = 1.07-17.93, p = 0.04). Conclusions: The children with limited language development in bimodal condition should be considered as the sequential bilateral cochlear implant and preoperative categories of auditory performance score could be used as the predictor in speech perception after sequential cochlear implant.


Resumo Introdução: Apesar dos avanços recentes na predição do resultado do implante coclear, ainda não está claro o benefício do procedimento bilateral em comparação com a estimulação bimodal e como podemos prever resultados de percepção da fala com implante coclear bilateral sequencial com base no desempenho auditivo bimodal em crianças. Objetivos: Este estudo foi realizado para: 1) Determinar o benefício do implante coclear bilateral sequencial e 2) Identificar os fatores associados com o resultado do implante bilateral sequencial. Método: Estudo observacional e retrospectivo. Analisamos retrospectivamente 29 pacientes com implantes sequenciais após a adaptação bimodal. Avaliações audiológicas foram realizadas; os escores das categorias de desempenho auditivo, a percepção da fala com palavras monossílabas e dissílabas e a versão coreana de Ling. As avaliações audiológicas foram realizadas antes do implante sequencial com o ajuste bimodal (IC1 + AH) e um ano após o implante coclear sequencial com implante bilateral (IC1 + IC2). O grupo com bom desempenho (BD) foi definido da seguinte forma: 90% ou mais em testes com monossílabos e dissílabos com condição apenas auditiva ou melhoria de 20% ou mais dos escores com IC1 + IC2. A idade no primeiro implante, o intervalo interimplante, o escore categorias de desempenho auditivo e as diversas comorbidades foram analisadas através de análise de regressão logística. Resultados: Em comparação com o IC1 + AA, IC1 + IC2 demonstraram benefícios significativos nos escores categorias de desempenho auditivo, percepção da fala e a versão coreana de Ling. Os escores de categorias de desempenho auditivo pré-operatórios foram o único fator associado para ser do grupo BD (odds ratio - OR = 4,38, intervalo de confiança de 95% - IC 95% = 1,07-17,93, p = 0,04). Conclusões: As crianças com desenvolvimento limitado de linguagem em condição bimodal devem ser consideradas, pois o implante coclear bilateral sequencial e o escore pré-operatório das categorias de desempenho auditivo poderiam ser usados como preditores na percepção da fala após implante sequencial.


Asunto(s)
Humanos , Masculino , Femenino , Lactante , Preescolar , Niño , Adolescente , Percepción del Habla/fisiología , Implantes Cocleares , Implantación Coclear/métodos , Pérdida Auditiva Bilateral/cirugía , Estudios Retrospectivos , Estudios de Seguimiento , Resultado del Tratamiento , Audición/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA