Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Analyst ; 138(22): 7006-11, 2013 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-24091385

RESUMEN

A novel portable SO2 gas sensor based on ionic liquid (IL) mediated electrochemiluminescence (ECL) for detecting SO2 at the ppb levels has been developed. The sensing system for SO2 detection is based on the strong quenching effect of SO2 on the ECL of the tris(2,2'-bipyridine)ruthenium(ii) (Ru(bpy)3(2+))/O2 coreactant system in the IL film. Over the potential window between -1.0 and +1.3 V, O2 can act as an effective coreactant for Ru(bpy)3(2+) ECL in ILs, giving a bright ECL emission. The ECL of the Ru(bpy)3(2+)/O2 system can be strongly inhibited by SO2 through the direct quenching of the excited state of the luminophore, i.e. Ru(bpy)3(2+)*, by SO2 molecules. The inhibited ECL intensity is proportional to the concentration of SO2 in the range from 40 to 2000 ppb with a detection limit of 20 ppb. The proposed SO2 ECL sensor can be operated at room temperature and shows high selectivity, good reproducibility and long-term stability in a dry atmosphere.

2.
Analyst ; 137(15): 3514-9, 2012 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-22728516

RESUMEN

This work reports that ammonia (NH(3)) can be used as an efficient co-reactant for tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) in ionic liquids (ILs), on the basis of which a signal-on ECL sensor for directly detecting gaseous NH(3) has been developed. The NH(3) ECL sensor has a very high sensitivity, with a detection limit of 10 ppt NH(3) (at signal-to-noise ratio of 3) without any preconcentration. The high sensitivity is mainly due to the zero ECL background of Ru(bpy)(3)(2+) in the ILs, strong co-reactant ECL activity of NH(3), and high solubility of NH(3) in imidazolium-based ILs. Additionally, the ECL sensor shows an excellent selectivity against common interfering gases and a wide linear response range from 10 ppt to 10 ppm.


Asunto(s)
Amoníaco/análisis , Técnicas Electroquímicas , Imidazoles/química , Líquidos Iónicos/química , Luminiscencia , 2,2'-Dipiridil/análogos & derivados , 2,2'-Dipiridil/química , Complejos de Coordinación , Mediciones Luminiscentes
3.
Anal Chem ; 83(17): 6862-7, 2011 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-21800911

RESUMEN

Electrochemiluminescence of the luminol-O(2) system in an electrolyte-free N,N-dimethylformamide (DMF)-dipropylamine (DPA) cosolution is induced by the formation of a carbamate ionic liquid (IL) from the reaction between CO(2) and DPA, on the basis of which a facile ECL sensor for measuring atmospheric CO(2) has been developed. This ECL sensing method shows several advantages in the detection of CO(2), such as high safety, high selectivity, wide linear response range, and good sensitivity. The gas sensor was found to have a linear response range from 100 ppm to 100 v/v% and a detection limit of 80 ppm (at signal-to-noise ratio of 3). This is the first reported IL-induced ECL sensor for a gas, thus the principle of this type of sensor and the IL-induced ECL mechanism have been demonstrated in detail.


Asunto(s)
Dióxido de Carbono/análisis , Técnicas Electroquímicas/métodos , Líquidos Iónicos/química , Mediciones Luminiscentes/métodos , Dimetilformamida , Formamidas/química , Gases/análisis , Luminol/química , Propilaminas/química
4.
Nanoscale ; 5(1): 225-30, 2013 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-23154515

RESUMEN

The preparation, characterization, fluorescence (FL) and electrochemiluminescence (ECL) of graphite-like carbon nitride nanoflake particles (g-C(3)N(4) NFPs) and nanoflake films (g-C(3)N(4) NFFs) have been reported. Highly water-dispersible g-C(3)N(4) NFPs with a height of ~5 to 35 nm and a lateral dimension of ~40 to 220 nm have been extracted from bulk g-C(3)N(4) materials by chemical oxidation. New, stable and defined g-C(3)N(4) NFFs can be easily obtained by drying NFPs on certain hydrophilic substrates such as glass or electrode surfaces. Both g-C(3)N(4) NFPs and g-C(3)N(4) NFFs have good FL activities, i.e. they can give strong blue light (435 nm) emission under UV light (365 nm) excitation. The as-prepared g-C(3)N(4) NFFs on a glassy carbon electrode exhibit strong non-surface state ECL activity in the presence of reductive-oxidative coreactants, including dissolved oxygen (O(2)), hydrogen peroxide (H(2)O(2)) and peroxydisulfate (S(2)O(8)(2-)) and give rise to blue light emission (435 nm), which is the same as the wavelength of FL. The non-surface state ECL mechanisms of the g-C(3)N(4) NFF-coreactant systems have been studied and discussed in detail.


Asunto(s)
Colorantes Fluorescentes/síntesis química , Grafito/química , Mediciones Luminiscentes/métodos , Nanoestructuras/química , Nitrilos/química , Campos Electromagnéticos , Colorantes Fluorescentes/efectos de la radiación , Grafito/efectos de la radiación , Ensayo de Materiales , Nanoestructuras/efectos de la radiación , Nanoestructuras/ultraestructura , Nitrilos/efectos de la radiación , Tamaño de la Partícula
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA