Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Blood Purif ; 42(4): 349-355, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27866200

RESUMEN

BACKGROUND/AIMS: Recent updates to the Nikkiso Aquarius continuous renal replacement therapy (CRRT) platform allowed us to develop a post-dilution protocol for regional citrate anticoagulation (RCA) using standard bicarbonate buffered, calcium containing replacement solution with acid citrate dextrose formula-A as a citrate source. Our objective was to demonstrate that the protocol was safe and effective. METHODS: Prospective audit of consecutive patients receiving RCA for CRRT within intensive care unit, who were either contraindicated to heparin or had poor filter lifespan (<12 h for 2 consecutive filters) on heparin. RESULTS: We present the first 29 patients who used 98 filters. After excluding 'non-clot' filter loss, 50% had a duration of >27 h. Calcium supplementation was required for 30 (30%) filter circuits, in 17 of 29 (58%) patients. One patient discontinued the treatment due to metabolic alkalosis, but there were no adverse bleeding events. CONCLUSION: Post-dilution RCA system is effective and simple to use on the Aquarius platform and results in comparable filter life for patients relatively contraindicated to heparin.


Asunto(s)
Anticoagulantes/administración & dosificación , Bicarbonatos , Tampones (Química) , Ácido Cítrico/administración & dosificación , Soluciones para Diálisis , Hemofiltración , Bicarbonatos/química , Soluciones para Diálisis/administración & dosificación , Soluciones para Diálisis/química , Electrólitos/química , Femenino , Hemofiltración/métodos , Humanos , Masculino , Resultado del Tratamiento
2.
Ann Thorac Surg ; 88(5): 1499-504, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19853100

RESUMEN

BACKGROUND: The three-dimensional saddle shape of the mitral annulus is well characterized in animals and humans, but the impact of annular nonplanarity on valve function or mechanics is poorly understood. In this study, we investigated the impact of the saddle shaped mitral annulus on the mechanics of the P2 segment of the posterior mitral leaflet. METHODS: Eight porcine mitral valves (n = 8) were studied in an in-vitro left heart simulator with an adjustable annulus that could be changed from flat to different degrees of saddle. Miniature markers were placed on the atrial face of the posterior leaflet, and leaflet strains at 0%, 10%, and 20% saddle were measured using dual-camera stereophotogrammetry. Averaged areal strain and the principal strain components are reported. RESULTS: Peak areal strain magnitude decreased significantly from flat to 20% saddle annulus, with a 78% reduction in the measured strain over the entire P2 region. In the radial direction (annulus free edge), a 44.4% reduction in strain was measured, whereas in the circumferential direction (commissure-commissure), a 34% reduction was measured from flat to 20% saddle. CONCLUSIONS: Nonplanar shape of the mitral annulus significantly reduced the mechanical strains on the posterior leaflet during systolic valve closure. Reduction in strain in both the radial and circumferential directions may reduce loading on the suture lines and potentially improve repair durability, and also inhibit progression of valve degeneration in patients with myxomatous valve disease.


Asunto(s)
Válvula Mitral/anatomía & histología , Válvula Mitral/fisiología , Sístole/fisiología , Animales , Fenómenos Biomecánicos , Técnicas In Vitro , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA