Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Thorac Cardiovasc Surg ; 129(3): 512-7, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15746732

RESUMEN

OBJECTIVE: The present study investigated the outcomes of aortic valve replacement with 17-mm mechanical prostheses in patients with isolated aortic stenosis. METHODS: Between January 1997 and January 2003, 35 patients (mean age, 63.4 +/- 17 years; median age, 70 years; age range, 16-84 years) underwent isolated aortic valve replacement with a 17-mm St Jude Medical Hemodynamic Plus (16 [45.7%] patients) or a St Jude Medical Regent prosthesis (19 [54.3%] patients). The paired Student t test or the paired Wilcoxon rank sum test were used to compare preoperative with follow-up echocardiographic measurements. RESULTS: Thirty-two (91.4%) patients were female, mean height was 154.4 +/- 8.3 cm, mean weight was 62.2 +/- 9.2 kg, and mean body surface area was 1.59 +/- 0.13 m 2 . The preoperative average New York Heart Association class was 2.8 +/- 0.8. The mean preoperative left ventricular mass index was 135.2 +/- 31 g/m 2 . Preoperative echocardiography showed an average gradient of 65.7 +/- 19.2 mm Hg (mean) and 103.6 +/- 30.7 mm Hg (peak) and a mean indexed effective orifice area of 0.40 +/- 0.1 cm 2 /m 2 . Echocardiographic follow-up time averaged 28.2 +/- 22.7 months (range, 13-72 months). Follow-up was 100% complete (1131.7 patient-months). Hospital mortality was 8.6% (3 patients). Actuarial 5-year survival was 94.7%. The mean postoperative New York Heart Association class was 1.13 +/- 0.34 ( P < .001), with 27 (87.1%) patients in class I and 4 patients in class II. A significant regression of the indexed left ventricular mass was found (postoperative mean value, 107.8 +/- 22.8 g/m 2 ; P < .0001), despite a mean indexed effective orifice area of 0.67 +/- 0.14 cm 2 /m 2 (median, 0.66 cm 2 /m 2 ). CONCLUSIONS: Selected patients with aortic stenosis can experience satisfactory clinical improvement and significant indexed left ventricular mass regression after aortic valve replacement with modern small-diameter bileaflet prostheses.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA