Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Magn Reson ; 24(1): 28, 2022 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-35418081

RESUMEN

BACKGROUNDS: Synthetic late gadolinium enhancement (LGE) images are less sensitive to inversion time (TI) and robust to motion artifact, because it is generated retrospectively by post-contrast T1-mapping images. To explore the clinical applicability of synthetic LGE, we investigated the image quality and diagnostic accuracy of synthetic LGE images, in comparison to that of conventional LGE for various disease groups. METHOD AND MATERIALS: From July to November 2019, a total of 98 patients who underwent cardiovascular magnetic resonance imaging (CMR), including LGE and T1-mapping sequences, with suspicion of myocardial abnormality were retrospectively included. Synthetic magnitude inversion-recovery (IR) and phase-sensitive IR (PSIR) images were generated through calculations based on the post-contrast T1-mapping sequence. Three cardiothoracic radiologists independently analyzed the image quality of conventional and synthetic LGE images on an ordinal scale with per-segment basis and the image qualities were compared with chi-square test. The agreement of LGE detection was analyzed on per-patient and per-segment basis with Cohen's kappa test. In addition, the LGE area and percentage were semi-quantitatively analyzed for LGE positive ischemic (n = 14) and hypertrophic cardiomyopathy (n = 13) subgroups by two cardiothoracic radiologists. The difference of quantified LGE area and percentage between conventional and synthetic LGE images were assessed with Mann-Whitney U-test and the inter-reader agreement was assessed with Bland-Altman analysis. RESULTS: The image quality of synthetic images was significantly better than conventional images in both magnitude IR and PSIR through all three observers (P < 0.001, all). The agreements of per-patient and per-segment LGE detection rates were excellent (kappa = 0.815-0.864). The semi-quantitative analysis showed no significant difference in the LGE area and percentage between conventional and synthetic LGE images. In the inter-reader agreement showed only small systematic differences in both magnitude IR and PSIR and synthetic LGE images showed smaller systematic biases compared to conventional LGE images. CONCLUSION: Compared to conventional LGE images, synthetic LGE images have better image quality in real-life clinical situation.


Asunto(s)
Medios de Contraste , Gadolinio , Humanos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Valor Predictivo de las Pruebas , Estudios Retrospectivos
2.
AJR Am J Roentgenol ; 218(3): 454-461, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34643105

RESUMEN

BACKGROUND. Current methods for calculating the myocardial extracellular volume (ECV) fraction require blood sampling to determine the serum hematocrit. Synthetic hematocrit and thus synthetic ECV may be derived using unenhanced attenuation of blood. By use of virtual unenhanced (VUE) attenuation of blood, contrast-enhanced dual-energy CT (DECT) may allow synthetic ECV calculations without unenhanced acquisition. OBJECTIVE. The purpose of this study was to compare synthetic ECV calculated using synthetic hematocrit derived from VUE images and conventional ECV calculated using serum hematocrit, both of which were obtained by contrast-enhanced DECT, with ECV derived from MRI used as the reference standard. METHODS. This retrospective study included 51 patients (26 men and 25 women; mean age, 59.9 ± 15.6 [SD] years) with nonischemic cardiomyopathy who, as part of an earlier prospective investigation, underwent equilibrium phase contrast-enhanced cardiac DECT and cardiac MRI and had serum hematocrit measured within 6 hours of both tests. A separate retrospective sample of 198 patients who underwent contrast-enhanced thoracic DECT performed on the same day for suspected pulmonary embolism and serum hematocrit measurement was identified to derive a synthetic hematocrit formula using VUE attenuation of blood by linear regression analysis. In the primary sample, two radiologists independently used DECT iodine maps to obtain the conventional ECV using serum hematocrit and the synthetic ECV using synthetic hematocrit based on the independently derived formula. The concordance correlation coefficient (CCC) was computed between conventional ECV and synthetic ECV from DECT. Conventional ECV and synthetic ECV from DECT were compared with the ECV derived from MRI in Bland-Altman analyses. RESULTS. In the independent sample, the linear regression formula for synthetic hematocrit was as follows: synthetic hematocrit = 0.85 × (VUE attenuation of blood) - 5.40. In the primary sample, the conventional ECV and synthetic ECV from DECT showed excellent agreement (CCC, 0.95). Bland-Altman analysis showed a small bias of -0.44% (95% limits of agreement, -5.10% to 4.22%) between MRI-derived ECV and conventional ECV from DECT as well as a small bias of -0.78% (95% limits of agreement, -5.25% to 3.69%) between MRI-derived ECV and synthetic ECV from DECT. CONCLUSION. Synthetic ECV and conventional ECV derived from DECT show excel lent agreement and a comparable association with ECV derived from cardiac MRI. CLINICAL IMPACT. Synthetic hematocrit from VUE attenuation of blood may allow myocardial tissue characterization on DECT without the inconvenience of blood sampling.


Asunto(s)
Cardiomiopatías/sangre , Cardiomiopatías/diagnóstico por imagen , Medios de Contraste , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Cardiomiopatías/fisiopatología , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
Radiology ; 301(1): 81-90, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34282972

RESUMEN

Background The Coronary Artery Disease Reporting and Data System (CAD-RADS) was established in 2016 to standardize the reporting of coronary artery disease at coronary CT angiography (CCTA). Purpose To assess the prognostic value of CAD-RADS at CCTA for major adverse cardiovascular events (MACEs) in patients presenting to the emergency department with chest pain. Materials and Methods This multicenter retrospective observational cohort study was conducted at four qualifying university teaching hospitals. Patients presenting to the emergency department with acute chest pain underwent CCTA between January 2010 and December 2017. Multivariable Cox regression analysis was used to evaluate risk factors for MACEs, including clinical factors, coronary artery calcium score (CACS), and CAD-RADS categories. The prognostic value compared with clinical risk factors and CACS was also assessed. Results A total of 1492 patients were evaluated (mean age, 58 years ± 14 years [standard deviation]; 759 men). During a median follow-up period of 31.5 months, 103 of the 1492 patients (7%) experienced MACEs. Multivariable Cox regression analysis showed that a moderate to severe CACS was associated with MACEs after adjusting for clinical risk factors (hazard ratio [HR] range, 2.3-4.4; P value range, <.001 to <.01). CAD-RADS categories from 3 to 4 or 5 (HR range, 3.2-8.5; P < .001) and high-risk plaques (HR = 3.6, P < .001) were also associated with MACEs. The C statistics revealed that the CAD-RADS score improved risk stratification more than that using clinical risk factors alone or combined with CACS (C-index, 0.85 vs 0.63 [P < .001] and 0.76 [P < .01], respectively). Conclusion The Coronary Artery Disease Reporting and Data System classification had an incremental prognostic value compared with the coronary artery calcium score in the prediction of major adverse cardiovascular events in patients presenting to the emergency department with acute chest pain. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Vliegenthart in this issue.


Asunto(s)
Dolor en el Pecho/complicaciones , Angiografía por Tomografía Computarizada/métodos , Sistemas de Información Radiológica , Calcificación Vascular/complicaciones , Calcificación Vascular/diagnóstico por imagen , Enfermedad Aguda , Estudios de Cohortes , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo
4.
J Cardiovasc Magn Reson ; 23(1): 64, 2021 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-34039372

RESUMEN

BACKGROUND: Right ventricular (RV) free wall fibrosis is an important component of adverse remodeling with RV dysfunction in pulmonary hypertension (PH). However, no previous reports have compared cardiovascular magnetic resonance (CMR) findings and histological analysis for RV free wall fibrosis in PH. We aimed to assess the feasibility of CMR T1 mapping with extracellular volume fraction (ECV) for evaluating the progression of RV free wall fibrosis in PH, and compared imaging findings to histological collagen density through an animal study. METHODS: Among 42 6-week-old Wistar male rats, 30 were classified according to disease duration (baseline before monocrotaline injection, and 2, 4, 6 and 8 weeks after injection) and 12 were used to control for aging (4 and 8 weeks after the baseline). We obtained pre and post-contrast T1 maps for native T1 and ECV of RV and left ventricular (LV) free wall for six animals in each disease-duration group. Collagen density of RV free wall was calculated with Masson's trichrome staining. The Kruskall-Wallis test was performed to compare the groups. Native T1 and ECV to collagen density were analyzed with Spearman's correlation. RESULTS: The mean values of native T1, ECV and collagen density of the RV free wall at baseline were 1541 ± 33 ms, 17.2 ± 1.3%, and 4.7 ± 0.5%, respectively. The values of RV free wall did not differ according to aging (P = 0.244, 0.504 and 0.331, respectively). However, the values significantly increased according to disease duration (P < 0.001 for all). Significant correlations were observed between native T1 and collagen density (r = 0.770, P < 0.001), and between ECV and collagen density for the RV free wall (r = 0.815, P < 0.001) in PH. However, there was no significant difference in native T1 and ECV values for the LV free wall according to the disease duration from the baseline (P = 0.349 and 0.240, respectively). CONCLUSIONS: We observed significantly increased values for native T1 and ECV of the RV free wall without significant increase of the LV free wall according to the disease duration of PH, and findings were well correlated with histological collagen density.


Asunto(s)
Ventrículos Cardíacos , Hipertensión Pulmonar , Animales , Fibrosis , Ventrículos Cardíacos/diagnóstico por imagen , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/patología , Imagen por Resonancia Cinemagnética , Masculino , Miocardio/patología , Valor Predictivo de las Pruebas , Ratas , Ratas Wistar , Función Ventricular Izquierda
5.
J Comput Assist Tomogr ; 45(3): 395-402, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34297510

RESUMEN

OBJECTIVE: This study aimed to compare the prognostic performance of Coronary Artery Disease (CAD)-Reporting and Data System (CAD-RADS) score with those of clinical risk factors and the extent of CAD classification for predicting major adverse cardiac events in emergency department patients. METHODS: A total of 779 patients with acute chest pain at low to intermediate risk for CAD underwent cardiac computed tomography angiography. The primary end point was early and late major adverse cardiac events. We developed the following models: model 1, clinical risk factors; model 2, clinical risk factors and CAD-RADS scores; model 3, clinical risk factors and extent of CAD. RESULTS: The C-statistics revealed that both CAD-RADS score and CAD extent improved risk stratification over the clinical risk factors (C-index for early events: C-index: 0.901 vs 0.814 and 0.911 vs 0.814; C-index for late events: 0.897 vs 0.808 and 0.905 vs 0.808; all P < 0.05). CONCLUSIONS: The CAD-RADS score had additional risk prediction benefits over clinical risk factors for emergency department patients.


Asunto(s)
Dolor en el Pecho/etiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Sistemas de Apoyo a Decisiones Clínicas , Sistemas de Información Radiológica , Adulto , Anciano , Enfermedad de la Arteria Coronaria/mortalidad , Servicio de Urgencia en Hospital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Medición de Riesgo , Factores de Riesgo , Tomografía Computarizada por Rayos X
6.
Radiology ; 287(2): 442-451, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29272215

RESUMEN

Purpose To investigate the diagnostic utility of dual-energy computed tomography (CT)-based monochromatic imaging for myocardial delayed enhancement (MDE) assessment in patients with cardiomyopathy. Materials and Methods The institutional review board approved this prospective study, and informed consent was obtained from all participants who were enrolled in the study. Forty patients (27 men and 13 women; mean age, 56 years ± 15 [standard deviation]; age range, 22-81 years) with cardiomyopathy underwent cardiac magnetic resonance (MR) imaging and dual-energy CT. Conventional (120-kV) and monochromatic (60-, 70-, and 80-keV) images were reconstructed from the dual-energy CT acquisition. Subjective quality score, contrast-to-noise ratio (CNR), and beam-hardening artifacts were compared pairwise with the Friedman test at post hoc analysis. With cardiac MR imaging as the reference standard, diagnostic performance of dual-energy CT in MDE detection and its predictive ability for pattern classification were compared pairwise by using logistic regression analysis with the generalized estimating equation in a per-segment analysis. The Bland-Altman method was used to find agreement between cardiac MR imaging and CT in MDE quantification. Results Among the monochromatic images, 70-keV CT images resulted in higher subjective quality (mean score, 3.38 ± 0.54 vs 3.15 ± 0.43; P = .0067), higher CNR (mean, 4.26 ± 1.38 vs 3.93 ± 1.33; P = .0047), and a lower value for beam-hardening artifacts (mean, 3.47 ± 1.56 vs 4.15 ± 1.67; P < .0001) when compared with conventional CT. When compared with conventional CT, 70-keV CT showed improved diagnostic performance for MDE detection (sensitivity, 94.6% vs 90.4% [P = .0032]; specificity, 96.0% vs 94.0% [P = .0031]; and accuracy, 95.6% vs 92.7% [P < .0001]) and improved predictive ability for pattern classification (subendocardial, 91.5% vs 84.3% [P = .0111]; epicardial, 94.3% vs 73.5% [P = .0001]; transmural, 93.0% vs 77.7% [P = .0018]; mesocardial, 85.4% vs 69.2% [P = .0047]; and patchy. 84.4% vs 78.4% [P = .1514]). For MDE quantification, 70-keV CT showed a small bias 0.1534% (95% limits of agreement: -4.7013, 5.0080). Conclusion Dual-energy CT-based 70-keV monochromatic images improve MDE assessment in patients with cardiomyopathy via improved image quality and CNR and reduced beam-hardening artifacts when compared with conventional CT images. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Cardiomiopatías/patología , Imagen por Resonancia Magnética , Miocardio/patología , Interpretación de Imagen Radiográfica Asistida por Computador , Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Cardiomiopatías/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
7.
Eur Radiol ; 28(5): 2151-2158, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29222675

RESUMEN

OBJECTIVES: The application of SYNTAX score II based on coronary CT angiography (CCTA) for selecting further treatment options has not been studied. This study aimed to investigate the diagnostic performance of CCTA combined with SYNTAX score II for selecting the revascularization method compared with invasive coronary angiography (ICA) based on 2014 European Society of Cardiology (ESC)/European Association for Cardio-Thoracic Surgery (EACTS) guidelines. METHODS: From January-May 2011, 160 patients who underwent both CCTA and ICA within 30 interval days were included. The diagnostic performance of CCTA, CCTA plus CT-SYNTAX score I and CT-SYNTAX score II was analysed using ICA counterparts as references. RESULTS: Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CCTA plus CT-SYNTAX I for selecting coronary artery bypass grafting (CABG) candidates using ICA plus ICA-SYNTAX I as reference, were 70.6 %, 95.8 %, 66.7 %, 96.5 % and 93.1 %, respectively. The diagnostic performance of CCTA plus CT-SYNTAX II showed improvement with values of 83.3 %, 97.3 %, 71.4 %, 98.6 % and 96.3 %, respectively, using ICA plus ICA-SYNTAX II as reference. CONCLUSIONS: CCTA combined with CT-SYNTAX score II is an accurate method for selecting CABG surgery candidates compared with ICA-SYNTAX score II. KEY POINTS: • SYNTAX plus CCTA can be highly specific for selecting the revascularization method. • SYNTAX II was complemented by including clinical considerations to SYNTAX I. • CCTA plus CT-SYNTAX II is an accurate method for selecting CABG candidates.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Revascularización Miocárdica/métodos , Anciano , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
8.
Acta Radiol ; 59(12): 1475-1481, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29635925

RESUMEN

BACKGROUND: Although the bismuth breast shield can reduce radiation exposure to the breast during dual-energy computed tomography (DECT), it can potentially affect material quantification on DECT due to artifacts. PURPOSE: To evaluate the effects of bismuth breast shielding on iodine quantification and radiation exposure in DECT. MATERIAL AND METHODS: Small balloons were made with 0.2%, 0.6% and 1.0% blended iodinated contrast (370 mg/mL of iodine) with water. The balloons were located at both anterior and posterior lungs in an adult anthropomorphic chest phantom. DECT was performed with and without breast shielding. Afterwards, iodine concentration values were measured for each balloon on the iodine maps. Absorbed radiation doses in the breast were measured with the optically stimulated luminescence dosimeter. RESULTS: After shielding, we obtained significantly decreased iodine quantification for all three concentrations with 0.78 ± 0.13 to 0.46 ± 0.13 mg/mL, 2.31 ± 0.17 to 1.68 ± 0.19 mg/mL, and 3.82 ± 0.10 to 2.84 ± 0.20 mg/mL at the anterior location, and 0.72 ± 0.11 to 0.48 ± 0.09 mg/mL, 2.24 ± 0.13 to 1.87 ± 0.21 mg/mL, and 3.75 ± 0.16 to 3.15 ± 0.14 mg/mL at the posterior location for the 0.2%, 0.6%, and 1.0% balloons, respectively ( P = 0.001 for all). After shielding, absorbed radiation doses to the breast significantly decreased by 14.8% (4.32 ± 0.33 to 3.68 ± 0.30 mGy; P = 0.005). CONCLUSION: Although using the bismuth breast shield may decrease radiation exposure to the breast on DECT, it may also significantly affect iodine quantification.


Asunto(s)
Bismuto , Mama/diagnóstico por imagen , Yodo , Fantasmas de Imagen , Protección Radiológica/instrumentación , Tomografía Computarizada por Rayos X , Humanos , Protección Radiológica/métodos
9.
Eur Radiol ; 27(5): 1992-2001, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27553938

RESUMEN

OBJECTIVES: To investigate the diagnostic value of dual-energy computed tomography (DECT) in differentiating between low- and high-risk thymomas and thymic carcinomas. MATERIALS: Our institutional review board approved this study, and patients provided informed consent. We prospectively enrolled 37 patients (20 males, mean age: 55.6 years) with thymic epithelial tumour. All patients underwent DECT. For quantitative analysis, two reviewers measured the following tumour parameters: CT attenuation value in contrast Hounsfield units (CHU), iodine-related HU and iodine concentration (mg/ml). Pathological results confirmed the final diagnosis. RESULTS: Of the 37 thymic tumours, 23 (62.2 %) were low-risk thymomas, five (13.5 %) were high-risk thymomas and nine (24.3 %) were thymic carcinomas. According to quantitative analysis, iodine-related HU and iodine concentration were significantly different among low-risk thymomas, high-risk thymomas and thymic carcinomas (median: 29.78 HU vs. 14.55 HU vs. 19.95 HU, p = 0.001 and 1.92 mg/ml vs. 0.99 mg/ml vs. 1.18 mg/ml, p < 0.001, respectively). CONCLUSION: DECT using a quantitative analytical method based on iodine concentration measurement can be used to differentiate among thymic epithelial tumours using single-phase scanning. KEY POINTS: • IHU and IC were lower in high-risk thymomas/carcinomas than in low-risk thymomas • IHU and IC were lower in advanced-stage thymomas than in early-stage thymomas • Dual-energy CT helps differentiate among thymic epithelial tumours.


Asunto(s)
Carcinoma/diagnóstico por imagen , Neoplasias Glandulares y Epiteliales/diagnóstico por imagen , Timoma/diagnóstico por imagen , Neoplasias del Timo/diagnóstico por imagen , Adulto , Anciano , Carcinoma/patología , Medios de Contraste , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Yopamidol , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Neoplasias Glandulares y Epiteliales/patología , Estudios Prospectivos , Timoma/patología , Neoplasias del Timo/patología , Tomografía Computarizada por Rayos X/métodos , Carga Tumoral
10.
AJR Am J Roentgenol ; 209(5): 1015-1022, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28898127

RESUMEN

OBJECTIVE: The purposes of this study were to investigate dual-energy CT findings predictive of clinical outcome and to determine the incremental risk stratification benefit of dual-energy CT findings compared with CT ventricular diameter ratio in patients with acute pulmonary embolism. MATERIALS AND METHODS: A retrospective evaluation was conducted of the cases of 172 patients with acute pulmonary embolism who underwent dual-energy CT. Ventricular diameter ratio and relative perfusion defect volume were measured. The primary endpoints were death within 30 days and pulmonary embolism-related death. RESULTS: A ventricular diameter ratio of 1 or greater was associated with increased risk of death within 30 days (hazard ratio, 3.822; p = 0.002) and pulmonary embolism-related death (hazard ratio, 18.051; p < 0.001). Relative perfusion defect volume was also associated with increased risk of death of any cause within 30 days (hazard ratio, 1.044; p = 0.014) and pulmonary embolism-related death (hazard ratio, 1.046; p = 0.017). However, the addition of relative perfusion defect volume to ventricular diameter ratio had no added benefit for prediction of death of any cause within 30 days (concordance statistic, 0.833 vs 0.815; p = 0.187) or pulmonary embolism-related death (concordance statistic, 0.873 vs 0.874; p = 0.866). CONCLUSION: Compared with ventricular diameter ratio alone, lung perfusion defect volume had no statistically significant added benefit for prediction of death of any cause within 30 days or of pulmonary embolism-related death among patients with acute PE.


Asunto(s)
Angiografía , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Circulación Pulmonar , Embolia Pulmonar/mortalidad , Embolia Pulmonar/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
11.
AJR Am J Roentgenol ; 208(5): W160-W167, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28225640

RESUMEN

OBJECTIVE: The objective of our study was to compare the image quality of cardiac CT images of mechanical valves in patients with irregular heart rates (HRs) using absolute-delay multiphase reconstruction versus relative-delay multiphase reconstruction. MATERIALS AND METHODS: A total of 26 patients with 40 mechanical valves who had atrial fibrillation during CT were included. The image quality of the CT scans was assessed for the subvalvular and valvular regions on a 4-point scale. The paired t test or Wilcoxon signed rank test was used to compare image quality scores between the relative-delay and absolute-delay reconstruction techniques. The overall image quality score was determined as the mean of the valvular and subvalvular region scores. RESULTS: For valvular regions, the image quality scores were 2.93 ± 0.73 (mean ± SD) for the relative-delay reconstruction technique and 3.55 ± 0.60 for the absolute-delay reconstruction technique (p < 0.0001). For subvalvular regions, the image quality scores were 2.8 ± 2.80 ± 0.79 and 3.35 ± 0.66 for the relative- and absolute-delay reconstructions (p < 0.0001), respectively. The nondiagnostic image quality group consisted of relative-delay reconstruction images of three valves (7.5%); the image quality scores for the absolute-delay reconstruction images of all three valves were improved, and the absolute-delay reconstruction images of the three valves were of diagnostic quality (p < 0.0001). CONCLUSION: Absolute-delay multiphase reconstruction can improve CT image quality of mechanical valves in patients with an irregular HR compared with relative-delay reconstruction.


Asunto(s)
Artefactos , Fibrilación Atrial/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Femenino , Frecuencia Cardíaca , Humanos , Yopamidol , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
Radiology ; 280(1): 49-57, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27322972

RESUMEN

Purpose To evaluate the feasibility of equilibrium contrast material-enhanced dual-energy cardiac computed tomography (CT) to determine extracellular volume fraction (ECV) in nonischemic cardiomyopathy (CMP) compared with magnetic resonance (MR) imaging. Materials and Methods This study was approved by the institutional review board; informed consent was obtained. Seven healthy subjects and 23 patients (six with hypertrophic CMP, nine with dilated CMP, four with amyloidosis, and four with sarcoidosis) (mean age ± standard deviation, 57.33 years ± 14.82; 19 male participants [63.3%]) were prospectively enrolled. Twelve minutes after contrast material injection (1.8 mL/kg at 3 mL/sec), dual-energy cardiac CT was performed. ECV was measured by two observers independently. Hematocrit levels were compared between healthy subjects and patients with the Mann-Whitney U test. In per-subject analysis, interobserver agreement for CT was assessed with the intraclass correlation coefficient (ICC), and intertest agreement between MR imaging and CT was assessed with Bland-Altman analysis. In per-segment analysis, Student t tests in the linear mixed model were used to compare ECV on CT images between healthy subjects and patients. Results Hematocrit level was 43.44% ± 1.80 for healthy subjects and 41.23% ± 5.61 for patients with MR imaging (P = .16) and 43.50% ± 1.92 for healthy subjects and 41.35% ± 5.92 for patients with CT (P = .15). For observer 1 in per-subject analysis, ECV was 34.18% ± 8.98 for MR imaging and 34.48% ± 8.97 for CT. For observer 2, myocardial ECV was 34.42% ± 9.03 for MR imaging and 33.98% ± 9.05 for CT. Interobserver agreement for ECV at CT was excellent (ICC = 0.987). Bland-Altman analysis between MR imaging and CT showed a small bias (-0.06%), with 95% limits of agreement of -1.19 and 1.79. Compared with healthy subjects, patients with hypertrophic CMP, dilated CMP, amyloidosis, and sarcoidosis had significantly higher myocardial ECV at dual-energy equilibrium contrast-enhanced cardiac CT (all P < .01) in per-segment analysis. Conclusion Myocardial ECV with dual-energy equilibrium contrast-enhanced CT showed good agreement with MR imaging findings, suggesting the potential of myocardial tissue characterization with CT. (©) RSNA, 2016.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Estudios de Factibilidad , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Estudios Prospectivos , Reproducibilidad de los Resultados
13.
Radiology ; 281(2): 597-605, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27203543

RESUMEN

Purpose To evaluate the feasibility of a simultaneous single scan of regional krypton and iodine concentrations by using dual-energy computed tomography (CT). Materials and Methods The study was approved by the institutional animal experimental committee. An airway obstruction model was first made in 10 beagle dogs, and a pulmonary arterial occlusion was induced in each animal after 1 week. For each model, three sessions of dual-energy CT (80% krypton ventilation [krypton CT], 80% krypton ventilation with iodine enhancement [mixed-contrast agent CT], and iodine enhancement [iodine CT]) were performed. Krypton maps were made from krypton and mixed-contrast agent CT, and iodine maps were made from iodine and mixed-contrast agent CT. Observers measured overlay Hounsfield units of the diseased and contralateral segments on each map. Values were compared by using the Wilcoxon signed-rank test. Results In krypton maps of airway obstruction, overlay Hounsfield units of diseased segments were significantly decreased compared with those of contralateral segments in both krypton and mixed-contrast agent CT (P = .005 for both). However, the values of mixed-contrast agent CT were significantly higher than those of krypton CT for both segments (P = .005 and .007, respectively). In iodine maps of pulmonary arterial occlusion, values were significantly lower in diseased segments than in contralateral segments for both iodine and mixed-contrast agent CT (P = .005 for both), without significant difference between iodine and mixed-contrast agent CT for both segments (P = .126 and .307, respectively). Conclusion Although some limitations may exist, it might be feasible to analyze regional krypton and iodine concentrations simultaneously by using dual-energy CT. © RSNA, 2016.


Asunto(s)
Obstrucción de las Vías Aéreas/diagnóstico por imagen , Yodo/farmacocinética , Criptón/farmacocinética , Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Animales , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Perros , Estudios de Factibilidad , Yodo/administración & dosificación , Criptón/administración & dosificación
14.
Tumour Biol ; 37(3): 3205-13, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26432331

RESUMEN

The serum tumor markers CYFRA 21-1, carcinoembryonic antigen (CEA), and squamous cell carcinoma antigen (SCCA) are useful in diagnosis and prognosis of non-small cell lung cancer (NSCLC). Cytologic tumor markers obtained during needle aspiration biopsies (NAB) of lung lesions are useful for NSCLC diagnosis. This study investigated the incremental prognostic value of cytologic tumor markers compared to serum tumor markers. This prospective study included 253 patients diagnosed with NSCLC by NAB with cytologic tumor marker analysis. Levels of cytologic CYFRA 21-1, CEA, SCCA, and their serum counterparts were followed up for survival analysis. Optimal cutoff values for each tumor marker were obtained for overall survival (OS) and progression-free survival (PFS) analyses. All patients were followed up for a median of 22.8 months. Using cutoff values of 0.44 ng/ml for C-SCCA, 2.0 ng/ml for S-SCCA, and 3.3 ng/ml for S-CYFRA, a multivariate analysis revealed that high S-SCCA (hazard ratio, HR, 1.84) and high C-SCCA (HR, 1.63) were independent predictive factors of OS. The 3-year overall survival rate was 55 vs. 80 % for high and low C-SCCA, respectively. Cytologic tumor marker level detection is easily obtainable and provides prognostic information for NSCLC. Cytologic tumor markers provide comparable prognostic information relative to serum tumor markers, with C-SCCA acting as a strong prognostic factor of overall survival and PFS.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Carcinoma de Pulmón de Células no Pequeñas/metabolismo , Neoplasias Pulmonares/metabolismo , Pulmón/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Antígenos de Neoplasias/sangre , Antígenos de Neoplasias/metabolismo , Biomarcadores de Tumor/sangre , Biopsia con Aguja Fina , Antígeno Carcinoembrionario/sangre , Antígeno Carcinoembrionario/metabolismo , Carcinoma de Pulmón de Células no Pequeñas/sangre , Carcinoma de Pulmón de Células no Pequeñas/patología , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Queratina-19/sangre , Queratina-19/metabolismo , Pulmón/patología , Neoplasias Pulmonares/sangre , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Estudios Prospectivos , Serpinas/sangre , Serpinas/metabolismo
15.
BMC Cancer ; 16: 224, 2016 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-26979333

RESUMEN

BACKGROUND: EGFR mutation-induced cell proliferation causes changes in tumor biology and tumor metabolism, which may reflect tumor marker concentration and 18F-FDG uptake on PET/CT. Direct aspirates of primary lung tumors contain different concentrations of tumor markers than serum tumor markers, and may correlate better with EGFR mutation than serum tumor markers. The purpose of this study is to investigate an association between cytologic tumor markers and FDG uptake with EGFR mutation status in non-small cell lung cancer (NSCLC). METHODS: We prospectively collected tumor aspirates of 61 patients who underwent EGFR mutation analysis. Serum and cytologic CYFRA 21-1, CEA, and SCCA levels were measured and correlated with EGFR gene mutations. FDG PET/CT was performed on 58 patients for NSCLC staging, and SUV was correlated with EGFR mutation status. RESULTS: Thirty (50%) patients had EGFR mutation and 57 patients had adenocarcinoma subtype. Univariate analysis showed that female gender, never smoker, high levels of cytologic CYFRA 21-1 (c-CYFRA) and lower maximum standard uptake value (SUVmax) were correlated with EGFR mutations. ROC generated cut-off values of 20.8 ng/ml for c-CYFRA and SUVmax of 9.6 showed highest sensitivity for EGFR mutation detection. Multivariate analysis revealed that female gender [hazard ratio (HR): 18.15, p = 0.025], higher levels of c-CYFRA (HR: 7.58, and lower SUVmax (HR: 0.08, p = 0.005) were predictive of harboring EGFR mutation. CONCLUSIONS: The cytologic tumor marker c-CYFRA was positively associated with EGFR mutations in NSCLC. EGFR mutation-positive NSCLCs have relatively lower glycolysis compared with NSCLCs without EGFR mutation.


Asunto(s)
Antígenos de Neoplasias/sangre , Biomarcadores de Tumor/genética , Carcinoma de Pulmón de Células no Pequeñas/genética , Receptores ErbB/genética , Queratina-19/sangre , Adulto , Anciano , Biomarcadores de Tumor/sangre , Antígeno Carcinoembrionario/sangre , Carcinoma de Pulmón de Células no Pequeñas/sangre , Carcinoma de Pulmón de Células no Pequeñas/patología , Proliferación Celular , Técnicas Citológicas , Femenino , Fluorodesoxiglucosa F18/administración & dosificación , Fluorodesoxiglucosa F18/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Mutación , Tomografía de Emisión de Positrones , Serpinas/sangre , Tomografía Computarizada por Rayos X
16.
Eur Radiol ; 26(9): 3162-70, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26638163

RESUMEN

OBJECTIVES: The purpose of this study was to determine whether dual-energy computed tomography (DECT) angiography could differentiate pulmonary thromboembolism (PTE) from pulmonary artery sarcoma (PAS). METHODS: We prospectively enrolled 19 patients that had a filling defect in the main pulmonary artery on DECT. Six patients who had PAS and underwent DECT were retrospectively enrolled for comparison. Pathological results or follow-up CT after anticoagulation therapy were used to make the final diagnosis. Two investigators measured the following parameters at the filling defect in the main pulmonary artery: CT attenuation density [Hounsfield units (HU)], iodine-related HU (IHU) and iodine concentration (IC, mg/ml). RESULTS: From a total of 25 patients (M:F = 10:15; mean age, 65 years old), 19 were categorised into the PTE group and six were categorised into the PAS group. The mean HU values were not significantly different between the PTE and PAS groups (45.5 ± 15.9 vs 47.1 ± 9.2 HU; P = 0.776). However, the mean IHU and IC values of the lesions were significantly different between the PTE and PAS groups (10.6 ± 7.2 vs 27.9 ± 9.1 HU; P = 0.004, and 0.61 ± 0.39 vs 1.49 ± 0.57; P = 0.001). CONCLUSIONS: DECT angiography using a quantitative analytic methodology can be used to differentiate PTE and PAS. KEY POINTS: • DECT can be useful for differentiation of PAS and PTE. • With quantitative analysis, DECT offers tissue characterisation by detecting lesion parameter increases. • The patients without predisposing factors for PTE can be candidates for DECT.


Asunto(s)
Neoplasias Pulmonares/diagnóstico , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico , Sarcoma/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Anciano , Angiografía , Diagnóstico Diferencial , Femenino , Humanos , Neoplasias Pulmonares/complicaciones , Masculino , Persona de Mediana Edad , Proyectos Piloto , Embolia Pulmonar/etiología , Estudios Retrospectivos , Sarcoma/complicaciones
17.
Radiology ; 276(2): 381-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25692312

RESUMEN

PURPOSE: To investigate cardiac computed tomographic (CT) findings predictive of recurrent stroke in patients with ischemic stroke and determine the incremental risk stratification benefit of cardiac CT findings compared with transesophageal echocardiography (TEE) findings in patients with ischemic stroke. MATERIALS AND METHODS: This single-center prospective study protocol was approved by the institutional review boards, and written informed consent was obtained from all patients. Among 548 consecutive patients, 374 patients with ischemic stroke (254 men and 120 women, with a mean age of 63.1 years) who underwent TEE and cardiac CT were prospectively enrolled in this study. TEE and cardiac CT images were assessed for cardioembolic sources, including thrombus, tumor, spontaneous echo contrast, valvular vegetation, atrial septal aneurysm, patent foramen ovale, and aortic plaque. The primary end point was stroke recurrence. Prognostic factors were assessed with Cox univariate and multivariate analysis. The integrated area under the receiver operating characteristic curve was calculated to compare the prognostic abilities of CT and TEE parameters. RESULTS: During a median follow-up period of 433 days, there were a total of 28 recurrent stroke events. The TEE parameter of plaque complexity (hazard ratio, 13.512; 95% confidence interval: 3.668, 49.778; P < .001) and CT parameter of plaque complexity (hazard ratio, 32.538; 95% confidence interval: 7.544, 140.347; P < .001) were predictors of recurrent stroke. The time-dependent receiver operating characteristic curve analysis demonstrated no significant differences in prediction of recurrent stroke between TEE and CT parameters (integrated area under the receiver operating characteristic curve, 0.812 vs 0.840, respectively). CONCLUSION: Complex aortic plaque evaluated with cardiac CT and TEE was associated with an increased risk of stroke recurrence in patients with ischemic stroke.


Asunto(s)
Isquemia Encefálica/diagnóstico , Isquemia Encefálica/epidemiología , Técnicas de Imagen Cardíaca , Ecocardiografía Transesofágica , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Tomografía Computarizada por Rayos X , Anciano , Isquemia Encefálica/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recurrencia , Medición de Riesgo , Accidente Cerebrovascular/etiología
18.
Korean J Radiol ; 25(6): 540-549, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38807335

RESUMEN

OBJECTIVE: This study investigated the feasibility and prognostic relevance of threshold-based quantification of myocardial delayed enhancement (MDE) on CT in patients with nonischemic dilated cardiomyopathy (NIDCM). MATERIALS AND METHODS: Forty-three patients with NIDCM (59.3 ± 17.1 years; 21 male) were included in the study and underwent cardiac CT and MRI. MDE was quantified manually and with a threshold-based quantification method using cutoffs of 2, 3, and 4 standard deviations (SDs) on three sets of CT images (100 kVp, 120 kVp, and 70 keV). Interobserver agreement in MDE quantification was assessed using the intraclass correlation coefficient (ICC). Agreement between CT and MRI was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). Patients were followed up for the subsequent occurrence of the primary composite outcome, including cardiac death, heart transplantation, heart failure hospitalization, or appropriate use of an implantable cardioverter-defibrillator. The Kaplan-Meier method was used to estimate event-free survival according to MDE levels. RESULTS: Late gadolinium enhancement (LGE) was observed in 29 patients (67%, 29/43), and the mean LGE found with the 5-SD threshold was 4.1% ± 3.6%. The 4-SD threshold on 70-keV CT showed excellent interobserver agreement (ICC = 0.810) and the highest concordance with MRI (CCC = 0.803). This method also yielded the smallest bias with the narrowest range of 95% limits of agreement compared to MRI (bias, -0.119%; 95% limits of agreement, -4.216% to 3.978%). During a median follow-up of 1625 days (interquartile range, 712-1430 days), 10 patients (23%, 10/43) experienced the primary composite outcome. Event-free survival significantly differed between risk subgroups divided by the optimal MDE cutoff of 4.3% (log-rank P = 0.005). CONCLUSION: The 4-SD threshold on 70-keV monochromatic CT yielded results comparable to those of MRI for quantifying MDE as a marker of myocardial fibrosis, which showed prognostic value in patients with NIDCM.


Asunto(s)
Cardiomiopatía Dilatada , Medios de Contraste , Estudios de Factibilidad , Fibrosis , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Masculino , Cardiomiopatía Dilatada/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Pronóstico , Tomografía Computarizada por Rayos X/métodos , Fibrosis/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Adulto , Anciano
19.
JAMA Netw Open ; 6(1): e2253820, 2023 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-36719681

RESUMEN

Importance: Dual-energy chest radiography exhibits better sensitivity than single-energy chest radiography, partly due to its ability to remove overlying anatomical structures. Objectives: To develop and validate a deep learning-based synthetic bone-suppressed (DLBS) nodule-detection algorithm for pulmonary nodule detection on chest radiographs. Design, Setting, and Participants: This decision analytical modeling study used data from 3 centers between November 2015 and July 2019 from 1449 patients. The DLBS nodule-detection algorithm was trained using single-center data (institute 1) of 998 chest radiographs. The DLBS algorithm was validated using 2 external data sets (institute 2, 246 patients; and institute 3, 205 patients). Statistical analysis was performed from March to December 2021. Exposures: DLBS nodule-detection algorithm. Main Outcomes and Measures: The nodule-detection performance of DLBS model was compared with the convolution neural network nodule-detection algorithm (original model). Reader performance testing was conducted by 3 thoracic radiologists assisted by the DLBS algorithm or not. Sensitivity and false-positive markings per image (FPPI) were compared. Results: Training data consisted of 998 patients (539 men [54.0%]; mean [SD] age, 54.2 [9.82] years), and 2 external validation data sets consisted of 246 patients (133 men [54.1%]; mean [SD] age, 55.3 [8.7] years) and 205 patients (105 men [51.2%]; mean [SD] age, 51.8 [9.1] years). Using the external validation data set of institute 2, the bone-suppressed model showed higher sensitivity compared with that of the original model for nodule detection (91.5% [109 of 119] vs 79.8% [95 of 119]; P < .001). The overall mean of FPPI with the bone-suppressed model was reduced compared with the original model (0.07 [17 of 246] vs 0.09 [23 of 246]; P < .001). For the observer performance testing with the data of institute 3, the mean sensitivity of 3 radiologists was 77.5% (95% [CI], 69.9%-85.2%), whereas that of radiologists assisted by DLBS modeling was 92.1% (95% CI, 86.3%-97.3%; P < .001). The 3 radiologists had a reduced number of FPPI when assisted by the DLBS model (0.071 [95% CI, 0.041-0.111] vs 0.151 [95% CI, 0.111-0.210]; P < .001). Conclusions and Relevance: This decision analytical modeling study found that the DLBS model was more sensitive to detecting pulmonary nodules on chest radiographs compared with the original model. These findings suggest that the DLBS model could be beneficial to radiologists in the detection of lung nodules in chest radiographs without need of the specialized equipment or increase of radiation dose.


Asunto(s)
Aprendizaje Profundo , Masculino , Humanos , Persona de Mediana Edad , Radiografía Torácica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía , Redes Neurales de la Computación
20.
J Thorac Imaging ; 38(2): 120-127, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36821380

RESUMEN

PURPOSE: To confirm that the image quality of coronary computed tomography (CT) angiography with a low tube voltage (80 to 100 kVp), iterative reconstruction, and low-concentration contrast agents (iodixanol 270 to 320 mgI/mL) was not inferior to that with conventional high tube voltage (120 kVp) and high-concentration contrast agent (iopamidol 370 mgI/mL). MATERIALS AND METHODS: This prospective, multicenter, noninferiority, randomized trial enrolled a total of 318 patients from 8 clinical sites. All patients were randomly assigned 1: 1: 1 for each contrast medium of 270, 320, and 370 mgI/mL. CT scans were taken with a standard protocol in the high-concentration group (370 mgI/mL) and with 20 kVp lower protocol in the low-concentration group (270 or 320 mgI/mL). Image quality and radiation dose were compared between the groups. Image quality was evaluated with a score of 1 to 4 as subject image quality. RESULTS: The mean HU, signal-to-noise ratio, and contrast-to-noise ratio of the 3 groups were significantly different (all P<0.0001). The signal-to-noise ratio and contrast-to-noise ratio of the low-concentration groups were significantly lower than those of the high-concentration group (P<0.05). However, the image quality scores were not significantly different among the 3 groups (P=0.745). The dose length product and effective dose of the high-concentration group were significantly higher than those of the low-concentration group (P<0.0001 and 0.003, respectively). CONCLUSIONS: The CT protocol with iterative reconstruction and lower tube voltage for low-concentration contrast agents significantly reduced the effective radiation dose (mean: 3.7±2.7 to 4.1±3.1 mSv) while keeping the subjective image quality as good as the standard protocol (mean: 5.7±3.4 mSv).


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Humanos , Angiografía Coronaria/métodos , Estudios Prospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA