Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ultrasound Obstet Gynecol ; 63(1): 98-104, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37428957

RESUMEN

OBJECTIVE: To describe the perinatal outcome of fetuses predicted to be large-for-gestational age (LGA) on universal third-trimester ultrasound in non-diabetic pregnancies of women attempting vaginal delivery. METHODS: This was a prospective population-based cohort study of patients from a single tertiary maternity unit in the UK offering universal third-trimester ultrasound and practicing expectant management of suspected LGA until 41-42 weeks. All women with a singleton pregnancy and an estimated due date between January 2014 and September 2019 were included. Women delivering before 37 weeks, those having a planned Cesarean delivery, those with pre-existing or gestational diabetes, those with fetal abnormalities and those who did not undergo a third-trimester scan were excluded from the assessment of perinatal outcome of cases with LGA predicted on ultrasound after implementation of the universal scan period. Association of LGA on universal third-trimester ultrasound screening and perinatal adverse outcome was assessed, with the exposures of interest being estimated fetal weight (EFW) at the 90th -95th , > 95th and > 99th percentile. The reference group was composed of fetuses with EFW at the 30th -70th percentile. Analysis was performed using multivariate logistic regression. The evaluated adverse perinatal outcomes included a composite outcome of admission to neonatal intensive care unit, Apgar score < 7 at 5 min and arterial cord pH < 7.1 (CAO1) and a composite outcome of stillbirth, neonatal death and hypoxic ischemic encephalopathy (CAO2). Secondary maternal outcomes were induction of labor, mode of delivery, postpartum hemorrhage, shoulder dystocia and obstetric anal sphincter injury. RESULTS: Cases with EFW > 95th percentile on universal third-trimester scan were at increased risk of CAO1 (adjusted odds ratio (aOR), 2.18 (95% CI, 1.69-2.80)) and CAO2 (aOR, 2.58 (95% CI, 1.05-6.34)). Cases with EFW at the 90th -95th percentile had a less pronounced increase in the risk of CAO1 (aOR, 1.35 (95% CI, 1.02-1.78)) and were not at increased risk of CAO2. All pregnancies with a fetus predicted to be LGA were at increased risk of all of the evaluated secondary maternal outcomes except for obstetric anal sphincter injury. The risk of adverse maternal outcome was typically higher with increasing EFW. Post-hoc exploration of data suggested that shoulder dystocia had a limited contribution to composite adverse perinatal outcomes in LGA cases (population attributable fraction of 10.8% for CAO1 and 29.1% for CAO2). CONCLUSIONS: Cases with EFW > 95th percentile are at increased risk of severe adverse perinatal outcome, such as death and hypoxic ischemic encephalopathy. These findings should aid antenatal counseling regarding the associated risk and delivery options. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Hipoxia-Isquemia Encefálica , Distocia de Hombros , Femenino , Humanos , Recién Nacido , Embarazo , Estudios de Cohortes , Peso Fetal , Feto , Edad Gestacional , Valor Predictivo de las Pruebas , Resultado del Embarazo , Tercer Trimestre del Embarazo , Estudios Prospectivos , Mortinato , Ultrasonografía Prenatal , Bebé Grande para la Edad Gestacional
2.
Artículo en Inglés | MEDLINE | ID: mdl-38669595

RESUMEN

OBJECTIVES: To investigate the association between varying degrees of abnormality in the uterine artery Doppler pulsatility index (UtA-PI) and adverse perinatal outcomes. METHODS: Prospective study of 33,364 women who gave birth to singleton, non-anomalous babies in Oxford, following universal measurement of UtA-PI in mid-pregnancy. Relative risk ratios for the primary outcomes of extended perinatal mortality and live birth with severe small-for-gestational-age (SGA) were calculated by multinomial logistic regression, for early preterm birth (<34+0) and late preterm/term birth (≥34+0). The risks were also investigated for iatrogenic preterm birth or a composite adverse outcome before 34+0 weeks. RESULTS: Compared with women with normal UtA-PI, the risk of extended perinatal mortality before 34+0 weeks was higher in women with UtA-PI >90th centile (RRR 4.7, 95% CI 2.7-8.0, p<0.001), but this was not demonstrated in later births. The risk of severe SGA birth was strongly associated with abnormal UtA-PI for both early births (RRR 26.0, 95% CI 11.6-58.2, p<0.001), and later births (RRR 2.3, 95% CI 1.8-2.9, p<0.001). Women with a raised UtA-PI were more likely to undergo early iatrogenic birth (RRR 7.8, 95% CI 5.5-11.2, p<0.001). For each of the outcomes and the composite outcome, the risk increased significantly in association with the degree of abnormality, through the 90th, 90-94th, 95-99th and >99th centiles (ptrend<0.001). CONCLUSIONS: An elevated UtA-PI is a key predictor of iatrogenic preterm birth, severe SGA and perinatal loss up to 34+0 weeks. It is the 90th centile that should be used, and management should be further tailored to the degree of abnormality, as pregnancies with very raised UtA-PI measurements constitute a group at extreme risk. This article is protected by copyright. All rights reserved.

3.
Ultrasound Obstet Gynecol ; 60(3): 373-380, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35708532

RESUMEN

OBJECTIVE: To determine the extent to which the detection rate of small-for-gestational age (SGA) and large-for-gestational age (LGA) at birth is influenced by the use of different combinations of estimated-fetal-weight (EFW) and birth-weight (BW) charts. METHODS: This was a cohort study of all pregnant women with a singleton term birth receiving care in a university hospital during a 3-year period. All participants underwent a universal 36-week ultrasound scan for EFW measurement and had BW recorded at delivery. Five different reference charts were used for EFW and BW centile calculation. Two-by-two contingency tables were constructed using EFW as the screening test variable and BW as the outcome variable in order to calculate sensitivity, specificity, positive predictive value (PPV) and negative predictive value for all possible chart combinations. RESULTS: The cohort included 17 678 pregnancies. The sensitivity of EFW < 10th centile for the detection of BW < 10th centile ranged from 10.8% to 66.8% and the sensitivity of EFW < 3rd centile for the detection of BW < 3rd centile ranged from 4.1% to 66.8%, depending on the charts used. The sensitivity of EFW > 90th centile for BW > 90th centile ranged between 22.9% and 68.3%. When locally derived charts for EFW and BW were used, the sensitivity of detection of BW < 10th centile using EFW < 10th centile was 43.7% (PPV, 45.5%); for the detection of BW < 3rd centile using EFW < 3rd centile, the sensitivity was 25.6% (PPV, 26.7%) and, for the detection of BW > 90th centile using EFW > 90th centile, it was 49.6% (PPV, 49.0%). CONCLUSIONS: Different combinations of EFW and BW charts can yield vastly different detection rates (sensitivity) in the same population cohort and time period. If SGA and LGA detection rates are to be used as a meaningful performance indicator, healthcare systems should follow a clear and predefined methodology that includes explicit definitions of common reference standards. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Peso Fetal , Ultrasonografía Prenatal , Peso al Nacer , Estudios de Cohortes , Femenino , Retardo del Crecimiento Fetal/diagnóstico , Edad Gestacional , Humanos , Recién Nacido , Recién Nacido Pequeño para la Edad Gestacional , Valor Predictivo de las Pruebas , Embarazo , Tercer Trimestre del Embarazo , Ultrasonografía Prenatal/métodos
4.
BJOG ; 128(2): 259-269, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32790134

RESUMEN

BACKGROUND: Routine third-trimester ultrasound is frequently offered to pregnant women to identify fetuses with abnormal growth. Infrequently, a congenital anomaly is incidentally detected. OBJECTIVE: To establish the prevalence and type of fetal anomalies detected during routine third-trimester scans using a systematic review and meta-analysis. SEARCH STRATEGY: Electronic databases (MEDLINE, Embase and the Cochrane library) from inception until August 2019. SELECTION CRITERIA: Population-based studies (randomised control trials, prospective and retrospective cohorts) reporting abnormalities detected at the routine third-trimester ultrasound performed in unselected populations with prior screening. Case reports, case series, case-control studies and reviews without original data were excluded. DATA COLLECTION AND ANALYSIS: Prevalence and type of anomalies detected in the third trimester. We calculated pooled prevalence as the number of anomalies per 1000 scans with 95% confidence intervals. Publication bias was assessed. MAIN RESULTS: The literature search identified 9594 citations: 13 studies were eligible representing 141 717 women; 643 were diagnosed with an unexpected abnormality. The pooled prevalence of a new abnormality diagnosed was 3.68 per 1000 women scanned (95% CI 2.72-4.78). The largest groups of abnormalities were urogenital (55%), central nervous system abnormalities (18%) and cardiac abnormalities (14%). CONCLUSION: Combining data from 13 studies and over 140 000 women, we show that during routine third-trimester ultrasound, an incidental fetal anomaly will be found in about 1 in 300 scanned women. This information should be taken into account when taking consent from women for third-trimester ultrasound and when designing and assessing cost of third-trimester ultrasound screening programmes. TWEETABLE ABSTRACT: One in 300 women attending a third-trimester scan will have a finding of a fetal abnormality.


Asunto(s)
Anomalías Congénitas/diagnóstico por imagen , Enfermedades Fetales/diagnóstico por imagen , Tercer Trimestre del Embarazo , Ultrasonografía Prenatal , Anomalías Congénitas/epidemiología , Anomalías Congénitas/patología , Femenino , Enfermedades Fetales/epidemiología , Enfermedades Fetales/patología , Humanos , Embarazo , Prevalencia
5.
BJOG ; 126(4): 493-499, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30223309

RESUMEN

OBJECTIVE: To analyse the outcome of referrals for external cephalic version (ECV). DESIGN: Retrospective cohort study of prospectively collected data. SETTING: Major university hospital, UK. SAMPLE: Women with non-cephalic presentation at term and no prior caesarean, referred to a specialist clinic. METHODS: Details of referrals, ECV attempts, and perinatal outcomes were prospectively collected and analysed. Multivariate binary logistic regression models were created to determine independent predictors of ECV success, reversion, and spontaneous version. MAIN OUTCOME MEASURES: External cephalic version success rates, predictors of success and cephalic presentation at birth, and perinatal outcomes. RESULTS: Three thousand eight had confirmed breech presentation; 2614 women underwent ECV. Ineligibility for ECV occurred in 117 breech presentations (3.9%), and 297 eligible women (10.2%) declined it. ECV was successful in 1280 (49.0%, 95% CI 47.0-50.9%) (40% in nulliparous women; 64% in others); 1234 (97.3%) were cephalic at birth. Spontaneous version after failure occurred in 4.3% and was more common in multiparas (aOR 2.47, 95% CI 1.43-4.26) and those with a posterior fetal back (aOR 6.09, 95% CI 1.90-19.53). Reversion after successful ECV occurred in 2.2%. In women with a successful ECV whose fetus remained cephalic at birth, 85.7% delivered vaginally. The corrected perinatal mortality of the ECV cohort was 0.12%. CONCLUSION: External cephalic version has a low complication rate and is effective for most breech presentations, enabling vaginal birth and avoiding caesarean section. TWEETABLE ABSTRACT: External cephalic version can safely be performed with most breech presentations.


Asunto(s)
Presentación de Nalgas/terapia , Parto Obstétrico/estadística & datos numéricos , Versión Fetal/estadística & datos numéricos , Adulto , Parto Obstétrico/métodos , Femenino , Humanos , Modelos Logísticos , Embarazo , Estudios Retrospectivos , Nacimiento a Término , Resultado del Tratamiento , Reino Unido , Vagina
6.
Ultrasound Obstet Gynecol ; 52(1): 66-71, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-28600829

RESUMEN

OBJECTIVE: Although no clear evidence exists, many international guidelines advocate early-term delivery of small-for-gestational-age (SGA) fetuses. The aim of this study was to determine whether a risk-stratification protocol in which low-risk SGA fetuses are managed expectantly beyond 37 weeks affects perinatal and maternal outcomes. METHODS: This was an impact study examining data collected over a 39-month period (1 January 2013 to 30 April 2016) at a tertiary referral unit. The study included women who were referred to the fetal medicine unit with a singleton non-anomalous fetus diagnosed antenatally as SGA (estimated fetal weight < 10th centile) from 36 + 0 weeks' gestation. In 2014, a protocol for management of SGA was introduced, which included risk stratification with surveillance and expectant management after 37 weeks for lower-risk babies (protocol group). This was compared with the previous strategy, which recommended delivery at around 37 weeks (pre-protocol group). Primary outcome was neonatal composite adverse outcome. RESULTS: In the pre-protocol group, there were 138 SGA babies; in the protocol group there were 143. Mean gestational ages at delivery were 37.4 weeks in the pre-protocol group and 38.2 weeks in the protocol group (P = 0.04). The incidence of neonatal composite adverse outcome was lower in the protocol group (9% vs 22%; P < 0.01), as was neonatal unit admission (13% vs 39%; P < 0.01). Induction of labor and Cesarean section rates were lower, and vaginal delivery rate (83% vs 60%; P < 0.01) was higher, in the protocol group. Most of the differences were as a result of delayed delivery of SGA babies that were stratified as low risk. CONCLUSIONS: The findings of this study suggest that protocol-based management of SGA babies may improve outcome, and that identification of moderate SGA should not in isolation prompt delivery. Larger numbers are required to assess any impact on perinatal mortality. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Cesárea/estadística & datos numéricos , Parto Obstétrico/estadística & datos numéricos , Retardo del Crecimiento Fetal/diagnóstico por imagen , Peso Fetal/fisiología , Adulto , Protocolos Clínicos , Femenino , Retardo del Crecimiento Fetal/fisiopatología , Edad Gestacional , Humanos , Recién Nacido , Recién Nacido Pequeño para la Edad Gestacional , Embarazo , Resultado del Embarazo , Tercer Trimestre del Embarazo , Estudios Retrospectivos , Medición de Riesgo , Factores de Tiempo
7.
Ultrasound Obstet Gynecol ; 52(4): 494-500, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29266519

RESUMEN

OBJECTIVE: To investigate whether abdominal circumference growth velocity (ACGV) improves the prediction of perinatal outcome in small-for-gestational-age (SGA) fetuses beyond that afforded by estimated fetal weight (EFW) and cerebroplacental ratio (CPR). METHODS: A cohort of 235 singleton SGA fetuses at 36-38 weeks' gestation was examined. ACGV, EFW and CPR centiles were calculated. ACGV centile was determined using data from a large database of 19-21- and 36-38-week scans in an unselected population. Binary variables of ACGV < 10th , EFW < 3rd and CPR < 5th centiles were defined as abnormal. Two composite adverse outcomes (CAO) were explored: CAO-1 defined as at least one of umbilical artery pH < 7.10, 5-min Apgar score < 7 or neonatal unit admission, and CAO-2 that included in addition hypoglycemia, intrapartum fetal distress and perinatal death. Univariate and multivariate logistic regression analyses were performed to analyze the relationship between the three risk factors and their predictive value for CAO. The change in screening performance afforded by adding ACGV to EFW and CPR was assessed and receiver-operating characteristics (ROC) curves were calculated. RESULTS: ACGV < 10th centile was an independent risk factor for CAO. The sensitivity, specificity, positive and negative likelihood ratios of a predictive model based on EFW < 3rd centile and CPR < 5th centile were, respectively, 51%, 70%, 1.71 and 0.69 for CAO-1 and 41%, 70%, 1.39 and 0.83 for CAO-2. After addition of ACGV < 10th centile to the model, the respective values were 82%, 46%, 1.54 and 0.38 for CAO-1 and 71%, 47%, 1.34 and 0.62 for CAO-2. Using continuous variables, the areas under the ROC curves improved marginally from 0.669 (95% CI, 0.604-0.729) to 0.741 (95% CI, 0.677-0.798) for CAO-1 and from 0.646 (95% CI, 0.580-0.707) to 0.700 (95% CI, 0.633-0.759) for CAO-2 after addition of ACGV to the model. CONCLUSIONS: ACGV is a risk factor for adverse neonatal outcome that is independent of EFW and of CPR, although any improvement in the prediction of adverse outcome is not statistically significant. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Abdomen/diagnóstico por imagen , Desarrollo Fetal/fisiología , Retardo del Crecimiento Fetal/fisiopatología , Recién Nacido Pequeño para la Edad Gestacional/crecimiento & desarrollo , Ultrasonografía Prenatal , Abdomen/embriología , Biometría , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Edad Gestacional , Humanos , Recién Nacido , Embarazo , Resultado del Embarazo , Estudios Prospectivos , Mortinato
8.
Pediatr Surg Int ; 31(2): 187-90, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25399359

RESUMEN

PURPOSE: The aim of this study was to establish the post-natal diagnosis and outcome of antenatally diagnosed intra-abdominal cysts between 1991 and 2013 at our institution. METHODS: All antenatally diagnosed intra-abdominal cysts between 1991 and 2013 were identified using a foetal anomaly database. The cysts were monitored for resolution. In all cases where the cyst had not resolved antenatally, additional post-natal scans were conducted. Antenatal diagnosis, post-natal diagnosis and outcomes were also recorded. RESULTS: 118 cases of antenatal intra-abdominal cysts were identified over the 22-year study period with a 98 % live birth rate. The overall accuracy of an antenatal diagnosis at our institution was 92 %. 26 cases (22 %) resolved spontaneously in utero, the majority of which (77 %) were ovarian in nature. Four tumour cases were identified in the series, which included two neuroblastomas, one yolk sac tumour and one teratoma. 90 cysts persisted post-natally with 52 % requiring surgery. These primarily included choledochal and enteric duplication cysts as well as symptomatic solid organ cysts. Diagnostic revision was limited to 8 % of cases over the study period with an overall improvement over the last decade. Overall, 40 % of all antenatally diagnosed cysts required surgical intervention. In those cysts that persisted post-natally, 52 % required surgery. CONCLUSIONS: A fifth of prenatally diagnosed intra-abdominal cysts will resolve with most ovarian cysts regressing in utero. Half of all persistent cysts will, however, require surgical intervention. These data are useful for prenatal counselling and demonstrates the important role played by the paediatric surgeon in the overall management of intra-abdominal cysts.


Asunto(s)
Quistes/diagnóstico por imagen , Enfermedades del Sistema Digestivo/diagnóstico por imagen , Quistes/cirugía , Enfermedades del Sistema Digestivo/cirugía , Femenino , Humanos , Quistes Ováricos/diagnóstico por imagen , Quistes Ováricos/cirugía , Embarazo , Diagnóstico Prenatal , Remisión Espontánea , Estudios Retrospectivos , Ultrasonografía Prenatal
9.
BJOG ; 119(7): 824-31, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22571747

RESUMEN

OBJECTIVE: To examine the relationship between umbilical cord pH at term and serious neonatal outcomes. DESIGN: Observational cohort study. SETTINGS: Deliveries within the Oxford Radcliffe Hospital NHS Trust between 1991 and 2009. POPULATION: In all, 51,519 singleton, term, nonanomalous live neonates with validated umbilical cord arterial pH values. METHODS: Absolute risks, relative risks with 95% confidence intervals, and numbers needed to harm were calculated for different levels of arterial pH across the entire range. MAIN OUTCOME MEASURES: Neonatal encephalopathy with seizures and/or death, encephalopathy within 24 hours of birth, 5-minute Apgar scores and neonatal unit admission. RESULTS: The median arterial pH was 7.22, interquartile range 7.17-7.27. The absolute risk of an adverse neurological outcome was significantly increased below 7.10 (0.36%) and was lowest between 7.26 and 7.30 (0.16%). Even below 7.00, the risk was only 2.95%. However, more than 75% of neonates with neurological outcomes examined, including seizures within 24 hours of birth, had a pH above 7.10. A small increase in risk was evident at higher pH levels. CONCLUSION: The threshold pH for adverse neurological outcomes is 7.10 and the 'ideal' cord pH is 7.26-7.30. Above 7.00, however, neonatal acidaemia is weakly associated with adverse outcomes. Most neonates with neurological morbidity have normal cord pH values. Other variables must influence adverse outcomes and account for more of these than acidaemia. A better understanding of these is required before intrapartum fetal monitoring can improve.


Asunto(s)
Acidosis/complicaciones , Encefalopatías/etiología , Sangre Fetal/fisiología , Concentración de Iones de Hidrógeno , Arterias Umbilicales , Acidosis/sangre , Acidosis/diagnóstico , Puntaje de Apgar , Análisis de los Gases de la Sangre , Encefalopatías/sangre , Encefalopatías/mortalidad , Humanos , Hipoxia/sangre , Hipoxia/complicaciones , Recién Nacido , Unidades de Cuidado Intensivo Neonatal , Admisión del Paciente/estadística & datos numéricos , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Convulsiones/sangre , Convulsiones/etiología , Convulsiones/mortalidad
10.
Ultrasound Obstet Gynecol ; 40(1): 75-80, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22009687

RESUMEN

OBJECTIVES: To demonstrate the influence of gain setting on the calculated Virtual Organ Computer-aided AnaLysis (VOCAL(™)) three-dimensional (3D) indices and define a point, the sub-noise gain (SNG), at which maximum information is available without noise artifact. METHODS: Pregnant women were recruited at the time of their pregnancy-dating scan. Five identical static 3D power Doppler volumes of the placenta were acquired using identical machine settings apart from altering the power Doppler gain setting. The gain settings included the individualized SNG setting (determined by increasing gain until noise artifact was visible, then reducing it until the artifact just disappeared). The data were analyzed using VOCAL II. Vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were calculated for the same sample at five different power Doppler gain levels. The relationship between the values calculated for the VOCAL indices and the gain value was explored using linear regression analysis. RESULTS: Results from 50 women were analyzed. The percentage difference in VI and VFI from that observed at the SNG level in each woman was significantly linearly related to the gain setting relative to that at the SNG point (VI: r(2) = 0.68, P < 0.0001; VFI: r(2) = 0.72, P < 0.0001), with the values produced for VI and VFI decreasing as the gain was turned down. There was a distinct 'turning point' at the SNG level with linear relationships above and below, but with significantly different gradients (P ≤ 0.001). This relationship was not demonstrated for FI. CONCLUSION: The SNG setting appears to represent each individual's optimum gain level. Using this may improve meaningful comparisons of VI and VFI between patients.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Fantasmas de Imagen , Placenta/irrigación sanguínea , Placenta/diagnóstico por imagen , Flujo Pulsátil , Ultrasonografía Doppler , Adulto , Femenino , Humanos , Imagenología Tridimensional , Embarazo , Primer Trimestre del Embarazo , Flujo Sanguíneo Regional
11.
Ultrasound Obstet Gynecol ; 40(6): 688-92, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22344971

RESUMEN

OBJECTIVE: To determine whether the technique of fractional moving blood volume (FMBV) is applicable to Virtual Organ Computer-aided AnaLysis II (VOCAL II™)-based indices to quantify three-dimensional power Doppler ultrasound (3D-PDU) by investigating the effect of gain level on the indices measured at a possible reference point for standardization. METHODS: Ten women with singleton pregnancy between 33+3 and 37+5 weeks' gestation were recruited. The optimal position for 3D acquisition of cord insertion into the placenta was identified and static 3D-PDU volumes were acquired using consistent machine configurations. Without moving the probe or the participant changing position, successive 3D volumes were stored at -3, -5, -7 and -9 dB and at the individualized sub-noise gain (SNG) level. Volumes were excluded if flash artifact was present, in which case all five volumes were reacquired. Using 4D View software, the cord insertion was magnified and the smallest sphere possible was used to measure vascularization index (VI), flow index (FI) and vascularization flow index (VFI). The associations between VOCAL indices and gain level were assessed using Pearson's correlation coefficient. RESULTS: VOCAL indices for cord insertion correlated poorly with gain level, whether fundamental or relative to SNG level (R(2) = 0.07 and 0.04, respectively). VI was consistently 100% and mean FI and VFI were 99.5 (SD, 0.57), with all values > 97 irrespective of gain level. CONCLUSIONS: Whilst previous work has shown that gain correlates well with placental tissue VOCAL indices, the correlation between gain level and VOCAL indices in an area of 100% vascularity at the cord insertion is poor. Regions of 100% vascularity appear to be artificially assigned a value approaching 100% for all VOCAL indices irrespective of gain level. This precludes using the technique of VOCAL indices from large vessels to standardize power Doppler measurements and the FMBV index is therefore not applicable to image analysis using VOCAL.


Asunto(s)
Volumen Sanguíneo/fisiología , Circulación Placentaria/fisiología , Adolescente , Adulto , Determinación del Volumen Sanguíneo/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Embarazo , Tercer Trimestre del Embarazo , Ultrasonografía Doppler/métodos , Ultrasonografía Prenatal/métodos , Interfaz Usuario-Computador , Adulto Joven
12.
Ultrasound Obstet Gynecol ; 40(2): 171-8, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22102536

RESUMEN

OBJECTIVE: To investigate whether the jets of blood from the mouths of the spiral arteries could be measured reliably, as well as their relationship with the uterine artery (UtA) and any differences in small-for-gestational-age (SGA) pregnancies. METHODS: Participants underwent serial ultrasound scans, from 11 weeks' gestation. Pulsatility index (PI) and resistance index (RI) of jets into the intervillous space (IVS) and UtA were recorded at every visit. Intra- and interobserver variability studies were performed. Customized birth weight centiles were calculated and SGA was defined as < 10(th) centile. Linear mixed model analysis was used to allow for the longitudinal nature of the data. RESULTS: Sixty-six women were recruited; 58 remained normotensive and delivered at term. Of these, six women delivered SGA newborns and 52 delivered appropriate-for-gestational-age newborns. All had pulsatile jets until 20 weeks' gestation. The PI and RI of the jets decreased with advancing gestation, following a trend similar to that of the UtAs. There was no correlation between the jets and UtA waveforms when gestational age was controlled for. For intraobserver variability the intraclass correlation coefficient was 0.9. The interobserver study showed no significant difference between the observers. Mixed model analysis demonstrated that PI and RI of jets were different in SGA pregnancies (P < 0.06). This difference was not seen for the UtAs (P = 0.8). CONCLUSION: This technique enables examination of characteristics of the jets of blood flowing from spiral arteries into the IVS. It is both precise and reproducible, with biologically plausible results. Further work is required to assess differences in pregnancies with adverse outcomes.


Asunto(s)
Flujo Pulsátil/fisiología , Ultrasonografía Doppler en Color/métodos , Ultrasonografía Doppler de Pulso/métodos , Ultrasonografía Prenatal/métodos , Arteria Uterina/diagnóstico por imagen , Adolescente , Adulto , Femenino , Humanos , Recién Nacido , Recién Nacido Pequeño para la Edad Gestacional , Variaciones Dependientes del Observador , Embarazo , Adulto Joven
13.
J Matern Fetal Neonatal Med ; 33(3): 421-426, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29950156

RESUMEN

Objective: To validate an objective scoring system for middle cerebral artery (MCA) pulsed wave Doppler images.Method: From an image database of routine 36-week scans, a random sample of MCA Doppler images was selected. Two reviewers rated the images subjectively as acceptable or unacceptable. Subsequently they used an objective 6-point image scoring system and awarded one point for each of the following: (1) anatomical site, (2) magnification, (3) angle of insonation, (4) image clarity, (5) sweep speed adjustment, and (6) velocity scale and baseline adjustment. Image scores 4-6 were defined as good quality whereas 0-3 as poor. The subjective and objective agreement between the two reviewers was compared using the adjusted Kappa statistic.Results: A total of 124 images were assessed. Using objective scoring the agreement rate between reviewers increased to 91.9% (κ = 0.839) compared to subjective agreement 75.8% (κ = 0.516). The agreement for each criterion was: anatomical site 91.1% (κ = 0.823), magnification 95.2% (κ = 0.903), clarity 83.9% (κ = 0.677), angle 96.0% (κ = 0.919), sweep speed 98.4% (κ = 0.968), and velocity scale and baseline 94.4% (κ = 0.887).Conclusion: Objective assessment of MCA Doppler images using a 6-point scoring system has greater interobserver agreement than subjective assessment and could be used for MCA Doppler quality assurance.


Asunto(s)
Arteria Cerebral Media/diagnóstico por imagen , Ultrasonografía Prenatal/normas , Femenino , Humanos , Embarazo , Ultrasonografía Doppler
14.
Pediatr Surg Int ; 25(5): 413-6, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19322571

RESUMEN

PURPOSE: Exomphalos is a midline defect, with a viable sac composed of amnion and peritoneum containing herniated abdominal contents with an incidence of about 1 in 4,000 live births. Associated major abnormalities can be karyotypic, syndromic or structural in up to 70% of cases. The aim of this study is to determine the factors that influence survival of antenatally diagnosed exomphalos. METHODS: All antenatally diagnosed and postnatally confirmed exomphalos registered with our fetal medicine unit, during 2002-2007, were reviewed. Both prenatal and postnatal outcomes were analysed. RESULTS: Of 88 cases identified with exomphalos, 85 were prenatally diagnosed. Fifty-five of them died in utero (45 terminations, 5 spontaneous abortions and 5 still births). There were 33 live births (37.5%), 7 of which were premature (30-35/40 gestation). Five babies died before coming to surgery (all with major exomphalos as well as abnormal karyotype) while 28 were operated upon. Fourteen cases with minor exomphalos, all isolated, were primarily closed and all survived to discharge. Of 14 babies with major exomphalos, 4 were closed primarily. Nine required silo formation and six successfully underwent secondary closure (one of which had a prenatal diagnosis of giant ruptured exomphalos). Three died before closure, two from sepsis and multi-organ failure, and one from an undiagnosed tracheo-oesophalgeal cleft. All three deaths had antenatally diagnosed giant ruptured exomphalos and were less than 34/40 weeks gestation. One baby was managed conservatively with antiseptic solution applied to the sac and left to heal by secondary intention. There were 17 cases of isolated exomphalos (with no other structural abnormalities), all of which survived. CONCLUSION: Antenatal diagnosis of exomphalos is 96% sensitive. Severe karyotypic and structural abnormalities were present in all intra-uterine and early postnatal deaths. Overall survival to discharge was 28%. Both minor and isolated exomphalos carried a good prognosis. Isolated exomphalos was a better prognostic factor than severity of the exomphalos itself. Ruptured giant exomphalos were associated with a poorer outcome especially in premature babies.


Asunto(s)
Hernia Umbilical/diagnóstico por imagen , Hernia Umbilical/mortalidad , Femenino , Humanos , Recién Nacido , Embarazo , Reproducibilidad de los Resultados , Ultrasonografía Prenatal , Reino Unido
16.
BJOG ; 114(5): 636-8, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17355270

RESUMEN

Most breech babies at term are now delivered by caesarean section. Although external cephalic version reduces the number of term breech presentations, its uptake has not been as wide as is recommended by professional bodies. This may be because of fears over safety. Pooled safety data do exist, largely from case series. However, the possibility of reporting and publication biases in such studies maybe preventing both women and obstetricians from being adequately reassured. In this series of 805 consecutive version attempts, we report an extremely low complication rate and 0.5% risk of emergency caesarean section after the procedure.


Asunto(s)
Presentación de Nalgas , Versión Fetal/efectos adversos , Adolescente , Adulto , Femenino , Humanos , Embarazo , Estudios Prospectivos , Ultrasonografía Prenatal
18.
Arch Dis Child Fetal Neonatal Ed ; 90(2): F141-6, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15724038

RESUMEN

OBJECTIVE: To investigate risk factors for cerebral palsy in relation to gestational age. DESIGN: Three case-control studies within a geographically defined cohort. SETTING: The former Oxfordshire Health Authority. PARTICIPANTS: A total of 235 singleton children with cerebral palsy not of postnatal origin, born between 1984 and 1993, identified from the Oxford Register of Early Childhood Impairment; 646 controls matched for gestation in three bands: or=37 weeks. RESULTS: Markers of intrapartum hypoxia and infection were associated with an increased risk of cerebral palsy in term and preterm infants. The odds ratio (OR) for hypoxia was 12.2 (95% confidence interval 1.2 to 119) at or=37 weeks. Corresponding ORs for neonatal sepsis were 3.1 (1.8 to 5.4) and 10.6 (2.1 to 51.9). In contrast, pre-eclampsia carried an increased risk of cerebral palsy at >or=37 weeks (OR 5.1 (2.2 to 12.0)) but a decreased risk at

Asunto(s)
Parálisis Cerebral/etiología , Edad Gestacional , Biomarcadores/análisis , Estudios de Casos y Controles , Parto Obstétrico/métodos , Femenino , Hipoxia Fetal/complicaciones , Humanos , Recién Nacido , Enfermedades del Recién Nacido/fisiopatología , Recién Nacido Pequeño para la Edad Gestacional/fisiología , Complicaciones del Trabajo de Parto/fisiopatología , Preeclampsia/fisiopatología , Embarazo , Complicaciones Infecciosas del Embarazo/fisiopatología , Factores de Riesgo , Sepsis/complicaciones
19.
Obstet Gynecol ; 92(5): 799-803, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9794672

RESUMEN

OBJECTIVE: To examine the outcome of trial second labor after a first cesarean performed because of cephalopelvic disproportion, defined according to strict diagnostic criteria. METHODS: Obstetric details of nulliparous women delivering at 37 or more weeks' gestation by cesarean for cephalopelvic disproportion, between 1975 and 1990, were recorded prospectively. The diagnostic criteria for cephalopelvic disproportion were cervical dilation arrested after 5 cm, unresponsive to oxytocin augmentation, after active dilatation of 2 cm or more in 2 hours. Fetal malpresentations and malpositions were excluded. The outcome of next delivery in our hospital by each woman enrolled was then examined. RESULTS: Eighty-four of 42,793 women met the criteria for disproportion, and 40 with cephalic presentations delivered their next baby in our hospital. All 40 underwent a trial of labor and 27 (68%) delivered vaginally, comprising seven (47%) women with larger second and 20 (80%) with smaller second babies. Of 15 women previously delivered by cesarean at full dilatation, 11 (73%) delivered vaginally with no serious maternal or neonatal morbidity. CONCLUSION: The strictly defined diagnosis of nulliparous cephalopelvic disproportion should not constitute an automatic "recurrent" indication for elective cesarean delivery, because 68% of patients in our series had successful vaginal deliveries in their next pregnancies. This rate is similar to those reported after all nulliparous cesareans for dystocia.


Asunto(s)
Complicaciones del Trabajo de Parto , Esfuerzo de Parto , Cesárea , Parto Obstétrico/métodos , Parto Obstétrico/estadística & datos numéricos , Femenino , Humanos , Pelvimetría , Embarazo , Estudios Prospectivos , Reoperación
20.
Arch Dis Child Fetal Neonatal Ed ; 85(3): F170-2, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11668157

RESUMEN

OBJECTIVES: To determine whether pre-eclampsia, hypothesised to be an inflammatory condition, is associated with fever in term labour, and confirm and examine the reported association of pre-eclampsia at term with neonatal encephalopathy. DESIGN: Prospective cohort study. SETTING: A Dublin teaching hospital. PARTICIPANTS: 6163 women in labour with singleton pregnancies at term at low risk for intrapartum hypoxia, recruited to a randomised trial examining the effect of admission cardiotocography on neonatal outcome. RESULTS: Pre-eclampsia was associated with maternal fever > 37.5 degrees in labour (odds ratio (OR) 3.39, 95% confidence interval (CI) 2.1 to 5.4); this was independent of obstetric intervention (adjusted OR 2.07, 95% CI 1.24 to 3.47). Pre-eclampsia was associated with neonatal encephalopathy (OR 25.5, 95% CI 8.4 to 74.7); this too was independent of obstetric intervention (adjusted OR 18.5, 95% CI 5.9 to 58.1). Cord arterial pH values were significantly lower in pre-eclamptics (7.20 v 7.24), although severe cord acidaemia was not significantly more common (OR 2.91, 95% CI 0.7 to 9.9). The association of pre-eclampsia with encephalopathy was independent of maternal fever (adjusted OR 16.5, 95% CI 5.1 to 54) and cord acidaemia (adjusted OR 13.5, 95% CI 3.2 to 56.7). CONCLUSIONS: The association of pre-eclampsia with maternal fever at term supports the hypothesis that pre-eclampsia is an inflammatory condition. The association of pre-eclampsia with neonatal encephalopathy is independent of obstetric intervention and cannot be explained by either acidaemia or maternal fever. A systemic inflammatory response in the fetus, perhaps secondary to oxidative stress, could explain the link between maternal pre-eclampsia and neonatal encephalopathy, and this may occur through cerebral vasoconstriction.


Asunto(s)
Encefalopatías/embriología , Fiebre/embriología , Preeclampsia , Análisis de los Gases de la Sangre , Encefalopatías/sangre , Proteína C-Reactiva/análisis , Cardiotocografía , Intervalos de Confianza , Femenino , Sangre Fetal/química , Humanos , Recién Nacido , Modelos Logísticos , Oportunidad Relativa , Embarazo , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA