Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 198-205, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037864

RESUMEN

INTRODUCTION: The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS: This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS: Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS: Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Femenino
2.
Artículo en Inglés | MEDLINE | ID: mdl-39188036

RESUMEN

BACKGROUND: Safety data of the latest radiofrequency (RF) technologies during atrial fibrillation (AF) ablation in real-world clinical practice are limited. OBJECTIVES: We sought to evaluate the acute procedural safety of the four latest ablation catheters commonly used for AF ablation. METHODS: A total of 3957 AF ablation procedures performed between January 2022 and December 2023 at 20 centers with either the THERMOCOOL SMARTTOUCH SF (STSF), TactiCath (TC), QDOT Micro (QDM), or TactiFlex (TF) were retrospectively analyzed. RESULTS: In total, QDM, STSF, TF, and TC were used in 343 (8.7%), 1793 (45.3%), 1121 (28.4%), and 700(17.7%) procedures. Among 2406 index procedures, electrical pulmonary vein isolations were successfully achieved in 99.5%. Despite similar total procedure times in the four groups, the total fluoroscopic time was significantly shorter for QDM/STSF with CARTO than TF/TC with EnSite (18.7 ± 14 vs. 27.6 ± 20.6 min, p < .001) and longest in the TF group. The incidence of cardiac tamponade was 0.7% (0.5% and 0.9% during index and redo procedures, 0.8% and 0.3% for paroxysmal and non-paroxysmal AF) and was significantly lower for QDM/STSF than TF/TC (0.2% vs. 1.1%, p = .008) and highest in the TF group. The incidence of cardiac tamponade was higher for TF than TC and STSF than QDM. In the multivariate analysis, TF/TC with EnSite was a significant independent predictor of cardiac tamponade during both the index (odds ratio [OR] = 4.8, 95% confidence interval [CI] = 1.3-17.5, p = .02) and all procedures (OR = 3.0, 95% CI = 1.3-7.2, p = .01). CONCLUSIONS: The incidence of cardiac tamponade and the fluoroscopic time during AF ablation significantly differed among the latest RF catheters and mapping systems in real-world clinical practice.

3.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
4.
Europace ; 25(4): 1400-1407, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36892146

RESUMEN

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fallo Renal Crónico , Tromboembolia , Humanos , Femenino , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Anticoagulantes/efectos adversos , Hemorragia/inducido químicamente , Tromboembolia/etiología , Tromboembolia/prevención & control , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico , Fallo Renal Crónico/terapia , Ablación por Catéter/efectos adversos , Sistema de Registros
5.
Europace ; 25(2): 374-381, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36414239

RESUMEN

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Nervio Frénico , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
6.
Europace ; 24(11): 1769-1776, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-35851606

RESUMEN

AIMS: The efficacy of left atrial posterior wall isolation (PWI) is controversial. Lesion durability may be a major cause of arrhythmia recurrence. The use of the lesion size prediction module improves lesion durability. This study aimed to compare the clinical outcomes of pulmonary vein isolation (PVI) alone and PWI in addition to PVI (PVI + PWI) in patients with non-paroxysmal atrial fibrillation (AF) using a lesion size prediction module. METHODS AND RESULTS: This study is a sub-analysis of the recently published prospective multicentre observational study called ALCOHOL-AF (association of alcohol consumption with outcome of catheter ablation of AF). In this sub-analysis, patients with non-paroxysmal AF in whom PVI alone or PVI + PWI was performed using the lesion size prediction module were included. Freedom from atrial tachyarrhythmia was compared between PVI alone and PVI + PWI groups using propensity score analyses. Of the 3474 patients registered in the ALCOHOL-AF study, 572 patients (age 65.6 ± 10.1 years, male 77.4%, longstanding persistent AF 25.5%) were included in this sub-analysis. We selected 212 patients treated with PVI alone and 212 treated with PVI + PWI using one-to-one propensity score matching. During the follow-up period, atrial tachyarrhythmia recurrence was documented in 92 (43.4%) and 50 (23.6%) patients in the PVI alone and PVI + PWI groups, respectively. Freedom from atrial tachyarrhythmia recurrence without anti-arrhythmic drugs after a single procedure was significantly higher in PVI + PWI than in PVI alone groups (hazard ratio: 0.452, 95% confidence interval: 0.308-0.664, P < 0.001). CONCLUSION: In this hypothesis-generating study, lesion size prediction module-guided PVI + PWI was associated with better clinical outcomes than PVI alone in patients with persistent or longstanding persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
7.
Am Heart J ; 231: 82-92, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33098808

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is the cornerstone of ablation strategies for atrial fibrillation (AF), and noninferiority of cryoballoon (CB) over radiofrequency (RF) ablation has been previously reported. One of the risk factors of recurrence is left atrium (LA) enlargement. This study aimed to analyze the impact of LA enlargement on the selection of CB or RF ablation for AF patients. METHODS: A total of 2,224 AF patients (64.4 ±â€¯10.7 years, 65.5% male) who underwent PVI were analyzed retrospectively. Left atrial diameter (LAD) and volume (LAV) were measured using echocardiography before the procedures. LA enlargement was defined as LAD ≥40 mm and LAV index (LAVI) ≥35 mL/m2. Patients undergoing CB and RF ablation were propensity score matched, and 376 matched pairs were evaluated. RESULTS: Cox proportional hazard analysis revealed that LAD (95% CI, 1.01-1.05), LAV (95% CI, 1.01-1.02), and LAVI (95% CI, 1.01-1.03) were independent predictors of recurrence. CB showed equivalent clinical outcomes to those of RF with shorter procedure time required for patients without LA enlargement. CB was inferior to RF in patients with LA enlargement (LAD, 74.5% vs 84.6%, P = .028; LAVI, 74.7% vs 83.4%, P = .015), and large LAVI was associated with a higher prevalence of non-PV foci (35% vs 29%, P = .008). CONCLUSIONS: CB ablation may be recommended for patients without enlarged LA based on the short procedure time and efficacy, whereas RF would be more appropriate in large LAs. LAVI may be a valuable reference to predict PVI outcomes and in selecting the ablation method.


Asunto(s)
Fibrilación Atrial/cirugía , Cardiomegalia/complicaciones , Ablación por Catéter/métodos , Criocirugía/métodos , Atrios Cardíacos/patología , Venas Pulmonares/cirugía , Anciano , Cardiomegalia/diagnóstico por imagen , Ecocardiografía , Femenino , Estudios de Seguimiento , Atrios Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Complicaciones Posoperatorias , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Venas Pulmonares/diagnóstico por imagen , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 32(5): 1251-1258, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33713521

RESUMEN

INTRODUCTION: Non-pulmonary vein (PV) triggers are a major cause of atrial tachyarrhythmia (ATA) recurrence after catheter ablation. However, the effect of the diagnosis-to-ablation time (DAT) on non-PV triggers in persistent atrial fibrillation is unknown. METHODS AND RESULTS: This observational study evaluated 502 consecutive persistent AF patients who underwent initial ablation. We compared 408 patients whose DAT was <3 years with 94 patients whose DAT was ≥3 years. Following PV and posterior wall isolation, 193 non-PV triggers, including 50 AFs, 30 atrial tachycardias (ATs), and 113 repetitive atrial premature beats, were elicited and ablated in 137 (27%) patients. Specifically, 80 non-PV AF/AT triggers were provoked in 64 (13%) patients, being identified more frequently in the DAT ≥ 3 years group than in the DAT < 3 years group (20% vs. 11%, p = .025) especially with a higher prevalence of coronary sinus/inferior left atrial triggers. During a median follow-up of 770 days, the ATA recurrence-free rate was higher in the DAT < 3 years group than the DAT ≥ 3 years group (79% vs. 53% at 2 years, p < .001). In a multivariate analysis, female sex (odds ratio: 2.70, p = .002) and a longer DAT (odds ratio: 1.13/year, p = .008) were predictors of non-PV AF/AT triggers, and a longer DAT (hazard ratio: 1.12/year, p < .001) and non-PV AT/AF triggers (hazard ratio: 1.79, p = .009) were associated with ATA recurrence. CONCLUSION: Early ablation after the first diagnosis of persistent AF may reduce emerging non-PV AF/AT triggers and ATA recurrence.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
9.
Oecologia ; 196(4): 1219-1232, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34313837

RESUMEN

Rice paddies function as wetlands; therefore, abandoned paddy fields cause a loss of habitats for aquatic species, such as amphibians. Following the accident at the Fukushima Daiichi Nuclear Power Plant in 2011, paddy fields around the plant were abandoned and rapidly dried. To identify the impact of large-scale abandonment of paddy fields on the habitats of frogs, we investigated changes in the distributions of four frogs that breed in paddy fields using niche modeling and field surveys. The spatial distributions of suitable habitats before and after the accident for each frog were created using MaxEnt. In the area where rice cropping was restricted due to radioactive contamination, the areas of suitable habitats decreased for Pelophylax porosus porosus but increased or remained unchanged for other frogs after the accident. Additionally, field surveys conducted in 2014 indicated that the ratios of breeding sites in the area where rice cropping was restricted were significantly lower for P. p. porosus and Hyla japonica than outside this area. Thus, 3 years after the accident, one species strongly dependent upon paddy fields rapidly disappeared over a large area. Although amphibian populations or monitoring data were not available to examine changes directly after the accident in the study area, this research showed that the combination of niche modeling and field survey was effective for predicting species response after an accident and revealed that large-scale disasters sufficient to disrupt agricultural activity could markedly change the distribution of species reliant on habitats created by human activity.


Asunto(s)
Accidente Nuclear de Fukushima , Animales , Radioisótopos de Cesio/análisis , Ecosistema , Granjas , Humanos , Japón , Fitomejoramiento
10.
Int Heart J ; 62(4): 771-778, 2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34276012

RESUMEN

Radiofrequency catheter ablation (RFCA) for pulmonary artery ventricular arrhythmia (PAVA) can be difficult because of the occasional existence of PAVA with preferential conduction.This study described the characteristics of PAVA that demonstrate preferential conduction.We analyzed electrocardiographic and electrophysiological data from 8 patients found to have PAVAs with preferential conduction out of 183 patients (4.4%) with right ventricular outflow tract (RVOT) arrhythmias who underwent RFCA at our hospitals. The PAVA with preferential conduction were classified into two types. In type 1 PAVA, successful ablation sites (success-sites) exhibited discrete prepotentials with an isoelectric line, in which the activation time (AT) was ≥ 50 milliseconds. In type 2 PAVA, excellent pace mapping was achieved at two sites separated by ≥ 20 mm: one in the RVOT free wall and the other at the success-site in the pulmonary artery. Type 1 and 2 PAVA features were considered signs of a short and long preferential conduction pathway, respectively.There were four patients each with type 1 and 2 PAVA. Type 1 PAVA was distinguished by the isoelectric line at success-sites with the mean AT of 78 ± 25.1 milliseconds. In type 2 PAVAs, although the AT at RVOT sites was very short (18.5 ± 10.1 milliseconds), the AT at success-sites was longer than that at the RVOT by 42.3 ± 36.2 milliseconds. Type 2 PAVAs displayed distinct electrocardiogram (ECG) features (R wave in lead I, RR' in inferior leads, and transitional zone in V4) not found in typical PAVA ECGs.PAVA with preferential conduction can manifest in distinct ways on the ECG and intracardiac mapping. Knowledge of these features may facilitate successful RFCA of such PAVA cases.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Ablación por Catéter , Electrocardiografía , Arteria Pulmonar/fisiopatología , Adolescente , Adulto , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad
11.
J Cardiovasc Electrophysiol ; 31(1): 174-184, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31828893

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) using cryoballoon is effective for patients with paroxysmal atrial fibrillation (PAF); however, few reports have evaluated the non-pulmonary vein (PV) foci after cryoballoon ablation. We aimed to evaluate the characteristics of non-PV foci and predictors of atrial fibrillation (AF) recurrence after cryoballoon ablation. METHODS AND RESULTS: This was a single-center retrospective study of 647 patients with PAF who underwent initial PVI using a second-generation cryoballoon. After PVI, all patients underwent high-dose isoproterenol infusion to assess the existence of non-PV foci. Non-PV foci were observed in 211 patients (32.6%), which were most frequently observed in the superior vena cava. Higher age (odds ratio [OR] = 1.02; 95% confidence interval [CI] = 1.00-1.04; P = .025), female sex (OR = 1.65; 95% CI = 1.13-2.41; P = .009), and lower body mass index (OR = 0.95; 95% CI = 0.89-1.00; P = .049) were significantly associated with non-PV foci. The existence of non-PV foci was an independent predictor of AF recurrence (Hazard's ratio = 1.70; 95% CI = 1.12-2.60; P = .014). When non-PV foci were mappable and successfully ablated, patients with non-PV foci showed similar outcomes with those without non-PV foci (1-year AF-free survival rates of 88.5% vs 91.5%; P = .338). Conversely, when we failed to detect and eliminate non-PV foci because they had multiple origins and were not consistently inducible (multichanging non-PV foci), the 1-year AF-free survival rate was 56.4% even after substrate modification. CONCLUSION: Non-PV foci were observed in one-third of patients with PAF after cryoballoon ablation and were associated with AF recurrence. Catheter ablation for non-PV foci was effective when they were mappable; however, multichanging non-PV foci were associated with worse prognosis.


Asunto(s)
Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 31(5): 1068-1074, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32128924

RESUMEN

AIMS: The current study sought to assess the impact of the utilized energy source during index ablation on long-term clinical outcomes after repeat ablation of atrial fibrillation (AF). Index ablation procedures were either performed using radiofrequency current (RFC) (RFC group) or cryoballoon (CB) ablation (CB group). Repeat ablation was performed by the use of RFC. METHODS: A total of 195 patients (138 RFC group; 57 CB group) with paroxysmal AF were included. All patients had a recurrence of AF following the index ablation procedure. Freedom from AF was estimated with the Kaplan-Meier method. RESULTS: After a 3 years follow-up, the estimated arrhythmia-free survival did not differ between the two groups (RFC group 48% vs CB group 47%, P = .78). During index ablation, procedure times were significantly shorter in the CB group (95 [80, 140] vs 140 [115, 164] minutes, P ≤ .001), whereas fluoroscopy times (16 [11; 22] vs 19 [14; 25] minutes, P = .003), the dose area product (1862 [1203; 2922] vs 3148 [1756; 5888] cGycm2 , P ≤ .001) and the amount of contrast dye (92 ± 32 vs 123 ± 33 mL, P ≤ .001) were significantly lower in the RFC group. During repeat ablation, procedure times were significantly shorter in patients being initially treated with RFC (115 [85; 145] vs 125 [105; 150] minutes, P = .007). There was a trend towards a higher pulmonary vein reconnection rate in the RFC group without meeting statistical significance (P = .074). CONCLUSIONS: In patients with repeat ablation of AF, index RFC or CB ablation are equally effective in terms of freedom from AF. Although CB ablation results in shorter index procedures times, durations of repeat ablation are significantly longer.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Supervivencia sin Enfermedad , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
13.
J Cardiovasc Electrophysiol ; 31(11): 2848-2856, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32786049

RESUMEN

INTRODUCTION: Lesion size and continuity in dragging laser balloon (LB) ablation, which may enable fast and durable pulmonary vein isolation for atrial fibrillation, are unknown. We evaluated the differences in size and continuity of linear lesions formed by dragging ablation and conventional point-by-point ablation using an LB in vitro model. METHODS AND RESULTS: Chicken muscles were cauterized using the first-generation LB in dragging and point-by-point fashion. Dragging ablation was manually performed with different dragging speeds (0.5-2°/s) using an overlap ratio of the beginning and last site during one application at 12 W/20 s and 8.5 W/30 s. Point-by-point ablation was performed with 25% and 50% overlap ratios at six energy settings (5.5 W/30 s to 12 W/20 s). Lesion depth, width, and continuity were compared. Lesion continuity was assessed by the surface and deep visible gap degree categorized from 1 (perfect) to 3 (poor). Twenty lesions were evaluated for each ablation protocol. Lesion depth and width in dragging ablation at high power (12 W) were comparable with most measurements in point-by-point ablation. Lesion depth and width were smaller at faster-dragging speed and lower power (8.5 W) in dragging ablation. The surface visible gap degree was better in dragging ablation at all dragging speeds than a 25% overlapped point-by-point ablation (p < .001). CONCLUSION: Dragging LB ablation at high power provides deep and continuous linear lesion formation comparable with that of point-by-point LB ablation. However, lesion depth and width depending on the dragging speed and power.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Terapia por Láser , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Humanos , Rayos Láser , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía
14.
Heart Vessels ; 35(12): 1709-1716, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32524235

RESUMEN

INTRODUCTION: Little evidence exists regarding cryoballoon ablation (CBA) of paroxysmal atrial fibrillation (PAF) in hemodialysis (HD) patients. We compared CBA and radiofrequency ablation (RFA) of PAF in HD patients, referring to CBA of PAF in non-HD patients. METHODS AND RESULTS: This historical cohort study examined 88 patients who underwent catheter ablation of PAF, including 21 HD patients with a second-generation 28-mm cryoballoon (CB-HD group), 17 HD patients with a non-force-sensing radiofrequency catheter (RF-HD group), and 50 non-HD patients with a cryoballoon (CB-non-HD group). Pulmonary vein (PV) isolation alone aside from cavotricuspid isthmus ablation was performed in 14 (67%) in the CB-HD group, 12 (71%) in the RF-HD group, and 36 (72%) in the CB-non-HD group (P = 0.95), without isoproterenol-induced non-PV triggers. Non-PV trigger ablation was added to the other patients. The Kaplan-Meier estimated 1-year freedom from atrial tachyarrhythmia recurrence without antiarrhythmic drugs after a single procedure was 76%, 59%, and, 92% in the CB-HD, RF-HD, and CB-non-HD groups, respectively (P = 0.002). The mean procedure time was shorter in the CB-HD group than in the RF-HD group (127 vs. 199 min; P < 0.001). In the second procedure, the median number of reconnected pulmonary veins was 0.5 in the CB-HD group versus 2.0 in the RF-HD group (P = 0.17). CONCLUSION: For PAF in HD patients, CBA showed a comparable single-procedure efficacy to that of RFA with a short procedure time. CBA may be a reasonable initial procedure for HD patients suffering from symptomatic PAF.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Enfermedades Renales/terapia , Venas Pulmonares/cirugía , Diálisis Renal , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Enfermedades Renales/diagnóstico , Enfermedades Renales/fisiopatología , Masculino , Persona de Mediana Edad , Tempo Operativo , Venas Pulmonares/fisiopatología , Recurrencia , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
J Cardiovasc Electrophysiol ; 30(7): 1156-1158, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31038815

RESUMEN

An 82-year-old man underwent redo catheter ablation of ventricular tachycardia (VT) after anterior infarction. A ripple mapping conducting channel (RMCC) was identified within the anterior scar in the left ventricular epicardium during sinus rhythm. Along the RMCC, delayed potentials during sinus rhythm, a good pace map with a long stimulus to the QRS interval, and mid-diastolic potentials during VT were recorded, and epicardial ablation at this site eliminated the VT. These findings suggested that the RMCC in the epicardial scar served as a critical isthmus of the postinfarct VT, and ablation targeting the RMCC was effective.


Asunto(s)
Infarto de la Pared Anterior del Miocardio/complicaciones , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Pericardio/cirugía , Taquicardia Ventricular/cirugía , Potenciales de Acción , Anciano de 80 o más Años , Infarto de la Pared Anterior del Miocardio/diagnóstico , Infarto de la Pared Anterior del Miocardio/fisiopatología , Electrocardiografía , Frecuencia Cardíaca , Humanos , Masculino , Pericardio/fisiopatología , Valor Predictivo de las Pruebas , Recurrencia , Reoperación , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 30(10): 1792-1800, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31310033

RESUMEN

INTRODUCTION: Several studies have revealed that second-generation cryoballoon (CB)-based pulmonary vein (PV) isolation is noninferior to radiofrequency (RF)-based PV isolation for patients with drug-refractory paroxysmal atrial fibrillation (AF). However, electrophysiological differences in repeat ablation remain unclear. METHODS AND RESULTS: This study examined electrophysiological differences during the repeat ablation between patients who first underwent RF catheter ablation and CB ablation; PV durability and non-PV AF foci were assessed for these patients. We enrolled 919 and 491 patients who underwent CB ablation (CB group) and RF catheter ablation (RF group), respectively, for paroxysmal AF between January 2013 and June 2017 at our institution. PV isolation using RF ablation involved the left atrium (LA) antrum and part of the LA posterior wall. After 2 years of follow-up, 62 and 80 patients in the CB and RF groups, respectively, underwent repeat ablation. PV reconnections were more frequent in the RF group than in the CB group (left superior PV: 46.2% and 14.5%, P < .001; left inferior PV: 35.0% and 11.2%, P = .001; right superior PV: 40.0% and 22.6%, P = .031; right inferior PV: 36.2% and 19.4%, P = .039; PVs: 39.8% and 16.9%, P < .001). LA AF foci were more frequent in the CB group than in the RF group (27.4% and 7.5%; P = .002). Other non-PV foci were prevalent in both groups. CONCLUSION: Fewer LA-PV reconnections occurred with CB ablation. However, extensive PV isolation may eliminate many LA AF foci.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Técnicas Electrofisiológicas Cardíacas , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo
17.
Europace ; 20(10): 1591-1597, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-29244081

RESUMEN

Aims: Some studies have shown that the type of atrial fibrillation (AF), whether paroxysmal AF (PAF) or persistent or permanent AF (PeAF), affects the incidence of ischaemic stroke. This study sought to determine the relationship between the AF pattern and the severity and brain volume of infarction in an AF population including transient ischaemic attack (TIA) patients. Methods and results: This was a retrospective observational study. We studied 161 consecutive patients who were admitted to our stroke care unit with cardiogenic embolism or TIA related to non-valvular AF (age 79 ± 9.5, 78 females, and 87 PAF patients). We evaluated the differences in severity and infarct volume between the types of AF. Additionally, we divided the patients into three groups according to severe stroke (n = 38), TIA (n = 28), and those who were neither (stroke, n = 95) for the assessment of the predictors of severe stroke and TIA. Persistent or permanent atrial fibrillation patients with acute cardiogenic stroke or TIA had worse peak National Institute of Health Stroke Scale (NIHSS) scores [PAF median 4 (range 3-14), PeAF 17 (5.8-25); P < 0.0001] and worse NIHSS scores at discharge [PAF 2.0 (1-7), PeAF 11 (3-22); P < 0.0001]. Their infarct brain volume assessed by computed tomography or magnetic resonance imaging was also larger [PAF 4.4 (1.1-32) mL, PeAF 64 (6.9-170) mL; P < 0.0001]. Multivariate analysis of severe stroke vs. non-severe stroke patients showed that having PeAF was the only independent predictor of severe stroke [odds ratio (OR) 4.27, 95% confidence interval (CI) 1.91-10.2; P = 0.0003]. Comparison of TIA vs. non-TIA patients showed that PeAF (OR 0.120, 95% CI 0.0230-0.444; P = 0.0008) and anticoagulant use (OR 8.24, 95% CI 2.15-40.8; P = 0.0018) were independent predictors of TIA. Conclusion: Cardiogenic emboli due to non-valvular PeAF are associated with a worse acute clinical course and greater volume of infarction than those due to PAF.


Asunto(s)
Fibrilación Atrial/fisiopatología , Infarto Encefálico/fisiopatología , Embolia Intracraneal/fisiopatología , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Infarto Encefálico/diagnóstico por imagen , Infarto Encefálico/etiología , Femenino , Humanos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Ataque Isquémico Transitorio/diagnóstico por imagen , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/fisiopatología , Imagen por Resonancia Magnética , Masculino , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/fisiopatología
18.
Zoolog Sci ; 35(5): 396-401, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30298778

RESUMEN

The bitterling Acheilognathus melanogaster is a critically endangered primary freshwater fish endemic to the Pacific side of eastern Japan. To elucidate A. melanogaster genetic structure, we investigated phylogeography in nine populations, using gene sequences of mitochondrial Cytochrome b (Cytb), as well as nuclear Rhodopsin (Rho) and glycosyltransferase (Glyt). We found four Cytb-based geographical clusters unevenly divided between the northern and southern regions, with smaller groups in the south. Of the nuclear genes, Glyt did not show geographical differentiation, whereas Rho formed two clusters: one widely occurring and another restricted to central regions. Genetic diversity was generally higher in southern than in northern populations. Our results suggest that conservation of southern local populations is particularly important in maintaining the genetic diversity of this endangered fish.


Asunto(s)
Especies en Peligro de Extinción , Peces/genética , Peces/fisiología , Animales , Agua Dulce , Japón , Filogeografía
19.
Circ J ; 81(7): 974-980, 2017 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-28344202

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) using the 2nd-generation cryoballoon (CB2) for the treatment of atrial fibrillation (AF) has demonstrated encouraging acute and mid-term results. However, follow-up data on outcomes beyond 1 year are sparse. We investigated the 3-year outcome after PVI using the CB2.Methods and Results:100 patients with paroxysmal (PAF, 70/100 [70%] patients) or persistent AF (pAF, 30/100 [30%] patients) underwent CB2-based PVI in 2 experienced centers in Germany. Freeze-cycle duration was 240 s. After successful PVI a bonus freeze-cycle of the same duration was applied in the first 71 patients but was omitted in the following 29 patients. Phrenic nerve palsy occurred in 3 patients (3%); 2 patients were lost to follow-up. After a median follow-up of 38 (29-50) months, 59/98 (60.2%) patients remained in stable sinus rhythm (PAF: 48/70 (69%), pAF: 11/28 (39%) P=0.0084). In 32/39 (77%) patients with arrhythmia recurrence, a second ablation procedure using radiofrequency energy was conducted. Persistent PVI was noted in 76/125 (61%) PVs. After a mean of 1.37±0.6 procedures and a median follow-up of 35 (25-39) months, 77/98 (78.6%) patients remained in stable sinus rhythm (PAF: 56/70 (80%), pAF: 20/28 (71%), P=0.0276). CONCLUSIONS: CB2-based PVI resulted in a 60.2% single-procedure and a 78.6% multiple-procedure success rate after 3 years. Repeat procedures demonstrated a high rate of durable PVI.


Asunto(s)
Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Recurrencia
20.
Pacing Clin Electrophysiol ; 40(11): 1318-1321, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28543389

RESUMEN

A 58-year-old man with a long R-P' narrow QRS tachycardia underwent an electrophysiological study. The tachycardia was diagnosed as a permanent form of junctional reciprocating tachycardia (PJRT), and the earliest atrial activation site during tachycardia was coronary sinus (CS) ostium. Radiofrequency ablation at the site was initially not successful because the tip impedance and temperature were unstable. After changing of the ablation catheter to that with contact force sensor, the accessory pathway was immediately ablated and the PJRT was no longer induced. A retrograde CS angiogram revealed a fusiform aneurysm, which was located at the earliest activation site during the tachycardia.


Asunto(s)
Ablación por Catéter/instrumentación , Aneurisma Coronario/diagnóstico , Aneurisma Coronario/cirugía , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/cirugía , Aneurisma Coronario/fisiopatología , Angiografía Coronaria , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Reciprocante/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA