Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Surg ; 75(3): 1038-1046.e3, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34601046

RESUMEN

BACKGROUND: Percutaneous devices for creation of native arteriovenous fistulae offer an alternative to traditional open surgical techniques. The 4F WavelinQ EndoAVF System was developed as a lower profile alternative to facilitate access through smaller vessels and minimize access site complications; The current report is the original first experience of this device, assessing outcome in 120 patients followed for 6 months. METHODS: The use of the 4F WavelinQ system in three studies, EASE (32 patients), EASE-2 (24 patients), and the EU postmarket clinical follow-up study (64 patients) was aggregated and analyzed. Patients were followed with duplex ultrasound at discharge and follow-up visits at 1, 3, and 6 months. Primary, assisted primary, and secondary patency rates were evaluated as Kaplan-Meier estimates and standard errors. Time to maturity and time to successful cannulation were defined as the mean ± standard deviation days from the procedure in patients enrolled on dialysis. RESULTS: Procedural success was achieved in 116 patients (96.7%). Primary, assisted-primary, and secondary 6-month patency rates were 71.9% ± 4.5%, 80.7% ± 4.1%, and 87.8% ± 3.3%, respectively. Time to maturity averaged 41 ± 17 days. Time to successful cannulation averaged 68 ± 51 days. Device-related serious adverse events were reported in 3 of 120 patients (2.5%) and procedure-related serious adverse events occurred in 7 of 120 patients (5.8%). Arterial or venous access complications were not reported in any of the patients. Access circuit reinterventions were performed in 23 patients (19.2%), split between those performed for EndoAVF maturation (13/120 [10.8%]) and maintenance (11/120 [9.2%]). CONCLUSIONS: Percutaneous creation of native dialysis fistulae with the 4F WavelinQ EndoAVF System is safe and effective, with favorable durability and a low rate of serious complications and reinterventions through 6-month follow-up. Use of the 4F device allows for percutaneous fistula creation between the radial artery and radial vein or the ulnar artery and ulnar vein. These findings suggest that the 4F device is a useful percutaneous alternative to open surgical AVF or endovascular AVF with larger bore devices.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/instrumentación , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Diálisis Renal , Insuficiencia Renal Crónica/terapia , Extremidad Superior/irrigación sanguínea , Adulto , Anciano , Anciano de 80 o más Años , Derivación Arteriovenosa Quirúrgica/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Ensayos Clínicos como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Arteria Radial/cirugía , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Arteria Cubital/cirugía , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular , Adulto Joven
2.
Clin Transplant ; 35(5): e14272, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33638883

RESUMEN

Concern regarding the quality of cold perfusion (QOP) during macroscopic assessment of procured kidneys is a common reason for discard. In the UK, QOP is routinely graded by both retrieving and implanting teams during back-bench surgery as: 1 (good), 2 (fair), 3 (poor) or 4 (patchy). We evaluated the association of this grading with organ utilization, graft outcomes, and agreement between teams. Data on all deceased-donor kidneys procured between January 2000 and December 2016 were analyzed for discard rates, while association with graft outcomes was studied in single adult transplants. Of 31,167 kidneys procured, 90.6%, 5.7%, 1.7%, and 2.1% were assigned grades 1, 2, 3, and 4, respectively, at retrieval. QOP was an independent risk factor of discard, with the highest rates observed in grade 3 kidneys (41.8%), compared to 6.5% in grade 1 (aOR 7.67, 95% CI 5.44-10.82, p < .001). Grading at retrieval was an independent predictor of delayed graft function (p = .019) and primary non-function (p = .001), but not long-term graft survival (p = .111). Implanting grade was an independent predictor of all three outcomes (p < .001, p < .001, and p = .002, respectively). Consistency of grading between teams was poor (Kappa = 0.179). QOP influences utilization and predicts outcomes, but a standardized and validated scoring system is required.


Asunto(s)
Trasplante de Riñón , Obtención de Tejidos y Órganos , Adulto , Estudios de Cohortes , Supervivencia de Injerto , Humanos , Riñón , Perfusión , Donantes de Tejidos , Reino Unido
3.
Transpl Int ; 34(11): 2122-2137, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34378227

RESUMEN

Strict isolation of vulnerable individuals has been a strategy implemented by authorities to protect people from COVID-19. Our objective was to investigate health-related quality of life (HRQoL), uncertainty and coping behaviours in solid organ transplant (SOT) recipients during the COVID-19 pandemic. A cross-sectional survey of adult SOT recipients undergoing follow-up at our institution was performed. Perceived health status, uncertainty and coping strategies were assessed using the EQ-5D-5L, Short-form Mishel Uncertainty in Illness Scale (SF-MUIS) and Brief Cope, respectively. Interactions with COVID-19 risk perception, access to health care, demographic and clinical variables were assessed. The survey was completed by 826 of 3839 (21.5%) invited participants. Overall, low levels of uncertainty in illness were reported, and acceptance was the major coping strategy (92%). Coping by acceptance, feeling protected, self-perceived susceptibility to COVID-19 were associated with lower levels of uncertainty. Health status index scores were significantly lower for those with mental health illness, compromised access to health care, a perceived high risk of severe COVID-19 infection and higher levels of uncertainty. A history of mental health illness, risk perceptions, restricted healthcare access, uncertainty and coping strategies was associated with poorer HRQoL in SOT recipients during strict isolation. These findings may allow identification of strategies to improve HRQoL in SOT recipients during the pandemic.


Asunto(s)
COVID-19 , Trasplante de Órganos , Adaptación Psicológica , Adulto , Estudios Transversales , Humanos , Pandemias , Calidad de Vida , SARS-CoV-2 , Receptores de Trasplantes , Incertidumbre
4.
Transpl Int ; 32(9): 918-932, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30793378

RESUMEN

Patient selection for combined liver-kidney transplantation (CLKT) is a current issue on the background of organ shortage. This study aimed to compare outcomes and post-transplant renal function for patients receiving CLKT and liver transplantation alone (LTA) based on native renal function using estimated glomerular filtration rate (eGFR) stratification. Using the UK National transplant database (NHSBT) 6035 patients receiving a LTA (N = 5912; 98%) or CLKT (N = 123; 2%) [2001-2013] were analysed, and stratified by KDIGO stages of eGFR at transplant (eGFR group-strata). There was no difference in patient/graft survival between LTA and CLKT in eGFR group-strata (P > 0.05). Of 377 patients undergoing renal replacement therapy (RRT) at time of transplantation, 305 (81%) and 72 (19%) patients received LTA and CLKT respectively. A significantly greater proportion of CLKT patients had severe end-stage renal disease (eGFR < 30 ml/min/1.73 m2 ) at 1 year post-transplant compared to LTA (9.5% vs. 5.7%, P = 0.001). Patient and graft survival benefit for patients on RRT at transplantation was favouring CLKT versus LTA (P = 0.038 and P = 0.018, respectively) but the renal function of the long-term survivors was not superior following CLKT. The data does not support CLKT approach based on eGFR alone, and the advantage of CLKT appear to benefit only those who are on established RRT at the time of transplant.


Asunto(s)
Tasa de Filtración Glomerular , Trasplante de Riñón , Trasplante de Hígado/mortalidad , Sistema de Registros , Femenino , Supervivencia de Injerto , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Reino Unido/epidemiología
5.
Am J Transplant ; 18(6): 1408-1414, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29136348

RESUMEN

Evidence is currently lacking regarding the outcomes of kidneys undergoing hypothermic machine perfusion (HMP) in patients in the United Kingdom. Using the National Health Service Blood and Transplant database, the authors compared outcomes for recipients of single-organ donation after circulatory death (DCD) kidneys preserved with HMP with those preserved using only static cold storage (SCS). Between 2007 and 2015, HMP was used in 19.1% (864/4,529) of kidneys. Rates of delayed graft function (DGF) were significantly lower in organs preserved with HMP than for organs preserved with SCS (34.2% vs 42.0%, P < .001), despite a slightly longer cold ischemic time (median: 14.8 vs 14.1 hours, P < .001). Multivariable analysis found the effect of preservation modality to remain significant, with HMP organs having a significantly lower rate of DGF (odds ratio 0.65, 95% confidence interval 0.53-0.80, P < .001) and significantly shorter times to DGF resolution (average: 6.1 vs 7.4 days, P = .003) than SCS organs. The patient (P = .313) and graft (P = .263) survival rates were similar in the 2 preservation groups. HMP was associated with a marginal functional benefit in 1-year creatinine values (P = .044), with adjusted averages of 1.36 mg/dL (HMP) versus 1.40 mg/dL (SCS). This study supports the use of HMP and aids decision-making over its instigation, which may improve short-term patient outcomes.


Asunto(s)
Isquemia Fría , Preservación de Órganos/métodos , Obtención de Tejidos y Órganos , Adulto , Creatinina/sangre , Funcionamiento Retardado del Injerto , Supervivencia de Injerto , Humanos , Persona de Mediana Edad , Análisis de Supervivencia , Reino Unido
6.
Transpl Int ; 31(10): 1099-1109, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29665191

RESUMEN

The aim of this study was to determine the effect of donor body mass index (BMI) on deceased donor kidney transplant outcomes. Data were collected from the UK Transplant Registry for all deceased donor kidney transplant recipients between January 2003 and January 2015. Univariable and multivariable analyses were undertaken to assess the impact of donor BMI on a range of outcomes. Donor BMI (kg/m2 ) was stratified as <18.5 (n = 380), 18.5-25.0 (n = 6890), 25.1-30.0 (n = 6669), 30.1-35.0 (n = 2503) and >35.0 (n = 1148). The prevalence of delayed graft function increased significantly with donor BMI (P < 0.001), with an adjusted odds ratio of 1.38 (95% CI: 1.16-1.63) for the >35.0 vs. 18.5-25.0 groups. However, there was no significant association between donor BMI and 12-month creatinine (P = 0.550), or patient (P = 0.109) or graft (P = 0.590) survival. In overweight patients, increasing donor BMI was associated with a significant increase in warm ischaemia time and functional warm ischaemia time, by an average of 4.6% (P = 0.043) and 5.2% (P = 0.013) per 10.0 kg/m2 . However, rising warm ischaemic time and functional warm ischaemic time was not significantly associated with delayed graft function, 12-month creatinine levels, graft loss or patient death. In this population cohort study, we identified no significant association between donor BMI and long-term clinical outcomes in deceased donor kidney transplantation.


Asunto(s)
Índice de Masa Corporal , Trasplante de Riñón , Insuficiencia Renal/cirugía , Donantes de Tejidos , Adulto , Estudios de Cohortes , Creatinina/sangre , Muerte , Funcionamiento Retardado del Injerto , Femenino , Supervivencia de Injerto , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Perfusión , Pronóstico , Sistema de Registros , Reino Unido , Isquemia Tibia
7.
J Ren Nutr ; 28(1): 13-27, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29089280

RESUMEN

OBJECTIVE: Cardiovascular disease is the leading cause of death in kidney transplant recipients (KTRs), yet incompletely accountable by traditional risk factors. Inflammation is an unconventional cardiovascular risk factor, with gut-derived endotoxemia potentially driving inflammation and endothelial disease. Comparable data are lacking in kidney transplantation. This study investigated the associations of endotoxemia with inflammation, endothelial activation, and 5-year cardiovascular events in KTRs. Determinants of endotoxemia were also explored. DESIGN AND METHODS: This is a single-center cross-sectional study with prospective follow-up from a prevalent cohort of 128 KTRs. MAIN OUTCOME MEASURES: Demographic, nutritional and clinical predictors of inflammation (high-sensitivity C-reactive protein [hsCRP]), endothelial activation (sE-selectin), and endotoxemia (endotoxin) were assessed. Follow-up data on 5-year cardiovascular event rates were collected. RESULTS: Endotoxemia (P = .03), reduced 25-hydroxyvitamin D (P = .04), high fructose intake (P < .001), decreased fiber intake (P < .001), and abdominal obesity (P = .002) were independently associated with elevated hsCRP. In turn, endotoxemia (P = .007) and increasing hsCRP (P = .02) were both independently associated with raised sE-selectin. Furthermore, endotoxemia predicted increased cardiovascular event rate (P = .02), independent of hsCRP and a global measure of cardiovascular risk estimated by a validated algorithm of 7-year risk for major adverse cardiac events in kidney transplantation. Determinants of endotoxemia included reduced 25-hydroxyvitamin D (P < .001), hypertriglyceridemia (P < .001), increased fructose intake (P = .01), and abdominal obesity (P = .01). CONCLUSIONS: Endotoxemia in KTRs contributes to inflammation, endothelial activation, and increased cardiovascular events. This study highlights the clinical relevance of endotoxemia in KTRs, suggesting future interventional targets.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Endotoxemia/diagnóstico , Inflamación/diagnóstico , Trasplante de Riñón/efectos adversos , Adiponectina/sangre , Adulto , Proteína C-Reactiva/metabolismo , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/complicaciones , Colesterol/sangre , Estudios Transversales , Endotoxemia/complicaciones , Endotoxinas/sangre , Femenino , Estudios de Seguimiento , Humanos , Inflamación/sangre , Inflamación/complicaciones , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Triglicéridos/sangre , Vitamina D/sangre
8.
Br J Nurs ; 27(2): S4-S10, 2018 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-29368572

RESUMEN

Tunnelled central venous access devices (CVADs) are defined as any intravenous multipurpose catheters placed within the central veins for use in haemodialysis and administration of blood products or chemotherapy in oncology and haematological conditions. Frequent complications include thrombosis and catheter-related infection, which may lead to significant adverse patient outcomes. Once thrombosis is suspected correction should be attempted empirically with thrombolytic agents. Commonly available thrombolytic agents in the UK include urokinase (Syner-Kinase) and alteplase (Cathflo). It is well recognised that urokinase usage differs widely and concerns were raised by clinicians about the variation of dose regimens nationally. The objective of the CVAD Focus Group was to address this issue and offer guidance in the management of suspected thrombosis of CVAD with urokinase using two algorithms for renal and non-renal dysfunctional CVAD and to audit prospectively the outcomes of intervention.


Asunto(s)
Fibrinolíticos/uso terapéutico , Trombosis/prevención & control , Activador de Plasminógeno de Tipo Uroquinasa/uso terapéutico , Cateterismo Venoso Central/efectos adversos , Catéteres de Permanencia/efectos adversos , Fibrinolíticos/administración & dosificación , Humanos , Guías de Práctica Clínica como Asunto , Medicina Estatal , Trombosis/enfermería , Reino Unido , Activador de Plasminógeno de Tipo Uroquinasa/administración & dosificación
10.
Transpl Infect Dis ; 19(6)2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28921746

RESUMEN

This case describes a patient being considered for combined liver-kidney transplantation for Caroli's disease with a failed renal transplant. A chronic septic focus could not be located with standard imaging techniques, such as ultrasonography and computed tomography. This case report highlights the observation that a retained non-functioning transplant can be the cause of fever of unknown origin and PET-CT can be useful in diagnosing these challenging cases.


Asunto(s)
Aloinjertos/diagnóstico por imagen , Enfermedad de Caroli/cirugía , Fiebre de Origen Desconocido/diagnóstico por imagen , Riñón/diagnóstico por imagen , Trasplante de Hígado/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Aloinjertos/microbiología , Aloinjertos/patología , Aloinjertos/cirugía , Fiebre de Origen Desconocido/microbiología , Fiebre de Origen Desconocido/patología , Fiebre de Origen Desconocido/cirugía , Rechazo de Injerto/microbiología , Humanos , Riñón/microbiología , Riñón/patología , Riñón/cirugía , Trasplante de Riñón/efectos adversos , Trasplante de Riñón/métodos , Cirrosis Hepática/congénito , Cirrosis Hepática/cirugía , Masculino , Necrosis , Nefrectomía , Enfermedades Renales Poliquísticas/cirugía , Cuidados Preoperatorios/métodos , Receptores de Trasplantes , Insuficiencia del Tratamiento , Ultrasonografía
11.
J Vasc Surg ; 63(6): 1647-50, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27050195

RESUMEN

OBJECTIVE: After carotid endarterectomy (CEA), patients have been regularly followed up by duplex ultrasound imaging. However, the evidence for long-term follow-up is not clear, especially if the results from an early duplex scan are normal. This study assessed and systematically reviewed the evidence base for long-term surveillance after CEA and a normal early scan. METHODS: Electronic databases were searched for studies assessing duplex surveillance after CEA in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The primary outcome for this study was the incidence of restenosis after a normal early scan. The secondary outcome was the number of reinterventions after a normal early scan. RESULTS: The review included seven studies that reported 2317 procedures. Of those patients with a normal early scan, 2.8% (95% confidence interval, 0.7%-6%) developed a restenosis, and 0.4% (95% confidence interval, 0%-0.9%) underwent a reintervention for their restenosis during the follow-up period. CONCLUSIONS: This review confirms that routine postoperative duplex ultrasound surveillance after CEA is not necessary if the early duplex scan is normal.


Asunto(s)
Arterias Carótidas/cirugía , Estenosis Carotídea/cirugía , Endarterectomía Carotidea , Ultrasonografía Doppler Dúplex , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/fisiopatología , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/fisiopatología , Endarterectomía Carotidea/efectos adversos , Humanos , Valor Predictivo de las Pruebas , Recurrencia , Retratamiento , Factores de Tiempo , Resultado del Tratamiento , Procedimientos Innecesarios
12.
J Vasc Surg ; 63(4): 1026-33, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26826055

RESUMEN

BACKGROUND: In end-stage renal disease patients with central venous obstruction, who have limited vascular access options, the Hemodialysis Reliable Outflow (HeRO) Graft is a new alternative with a lower incidence of complications and longer effective device life compared to tunneled dialysis catheters (TDCs). We undertook an economic analysis of introducing the HeRO Graft in the UK. METHODS: A 1-year cost-consequence decision analytic model was developed comparing management with the HeRO Graft to TDCs from the perspective of the National Health Service in England. The model comprises four 3-month cycles during which the vascular access option either remains functional for hemodialysis or fails, patients can experience access-related infection and device thrombosis, and they can also accrue associated costs. Clinical input data were sourced from published studies and unit cost data from National Health Service 2014-15 Reference Costs. RESULTS: In the base case, a 100-patient cohort managed with the HeRO Graft experienced 6 fewer failed devices, 53 fewer access-related infections, and 67 fewer device thromboses compared to patients managed with TDCs. Although the initial device and placement costs for the HeRO Graft are greater than those for TDCs, savings from the lower incidence of device complications and longer effective device patency reduces these costs. Overall net annual costs are £2600 for each HeRO Graft-managed patient compared to TDC-managed patients. If the National Health Service were to reimburse hemodialysis at a uniform rate regardless of the type of vascular access, net 1-year savings of £1200 per patient are estimated for individuals managed with the HeRO Graft. CONCLUSIONS: The base case results showed a marginal net positive cost associated with vascular access with the HeRO Graft compared with TDCs for the incremental clinical benefit of reductions in patency failures, device-related thrombosis, and access-related infection events in a patient population with limited options for dialysis vascular access.


Asunto(s)
Implantación de Prótesis Vascular/economía , Prótesis Vascular/economía , Cateterismo Venoso Central/economía , Catéteres de Permanencia/economía , Catéteres Venosos Centrales , Costos de la Atención en Salud , Fallo Renal Crónico/economía , Fallo Renal Crónico/terapia , Diálisis Renal/economía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Obstrucción del Catéter/economía , Obstrucción del Catéter/etiología , Infecciones Relacionadas con Catéteres/economía , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Relacionadas con Catéteres/terapia , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia/efectos adversos , Análisis Costo-Beneficio , Técnicas de Apoyo para la Decisión , Inglaterra , Oclusión de Injerto Vascular/economía , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Humanos , Fallo Renal Crónico/diagnóstico , Modelos Económicos , Diseño de Prótesis , Falla de Prótesis , Infecciones Relacionadas con Prótesis/economía , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/terapia , Medicina Estatal/economía , Trombosis/economía , Trombosis/etiología , Trombosis/terapia , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
13.
Transpl Int ; 29(3): 338-51, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26614985

RESUMEN

Physical fatigue is debilitating and common among kidney transplant recipients (KTRs). This study investigated the mechanistic aetiology of physical fatigue in this setting through examinations of muscle mass, muscular and cardiovascular function, and perceived exertion. The incidence of physical fatigue, its association with quality of life (QoL), and the predictors of perceived exertion, were evaluated. This single-centre observational cross-sectional study enrolled 55 KTRs. Muscle mass was quantified using dual-energy x-ray absorptiometry. Muscular function was assessed by jumping mechanography. Cardiovascular function (maximal oxygen consumption and oxygen pulse) was estimated during submaximal exercise testing, with perceived exertion determined using age-adjusted Borg scale-ratings. Physical fatigue was measured using Multi-Dimensional Fatigue Inventory-20. QoL was assessed using Medical Outcomes Study Short Form-36. Demographic, clinical, nutritional, psychosocial and behavioural predictors of perceived exertion were assessed. Of clinical importance, increased perceived exertion was the only independent predictor of physical fatigue (P = 0.001), with no association found between physical fatigue and muscular or cardiovascular parameters. Physical fatigue occurred in 22% of KTRs, and negatively impacted on QoL (P < 0.001). Predictors of heightened perception included anxiety (P < 0.05) and mental fatigue (P < 0.05). Perception is a key determinant of physical fatigue in KTRs, paving the way for future interventions.


Asunto(s)
Fatiga/etiología , Trasplante de Riñón , Complicaciones Posoperatorias/etiología , Adulto , Estudios Transversales , Fatiga/epidemiología , Fatiga/psicología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiología , Consumo de Oxígeno , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/psicología , Calidad de Vida , Reino Unido/epidemiología
14.
Ann Vasc Surg ; 32: 1-4, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26806240

RESUMEN

BACKGROUND: The fistula first initiative has promoted arteriovenous fistulas (AVFs) as the vascular access of choice. To preserve as many future access options as possible, multiple guidelines advocate that the most distal AVF possible should be created in the first place. Generally, snuff box and radiocephalic (RC) are accepted and well-described sites for AVFs; however, the forearm ulnar-basilic (UB) AVF is seldom used or recommended. The aim of this study is to assess and systematically review the evidence base for the creation of the UB fistula and to critically appraise whether more attention should be given to this site. METHODS: Electronic databases were searched for studies involving the creation of UB fistulas for dialysis in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The primary outcomes for this study were 1-year primary and secondary patency rates. Secondary outcomes were rates of hemodialysis access-induced distal ischemia (HAIDI) and infection. RESULTS: After strict inclusion and/or exclusion criteria by 2 reviewers, 8 studies were included in our review. Weighted-pooled data reveal 1-year primary patency rate for UB AVFs of 53.0% (95% confidence interval [CI]: 40.1-65.8%) with a secondary patency rate of 72.0% (95% CI: 59.2-83.3). HAIDI and infection rates were low. CONCLUSIONS: Our review has shown that the UB AVF may be a viable alternative when a RC AVF is not possible, and dialysis is not required urgently. It has adequate 1-year primary and secondary patency rates and extremely low risk of HAIDI. While it may be more challenging for both surgeons and dialysis nurses to make it a successful vascular access it offers a further option of distal access which may be overlooked.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/métodos , Diálisis Renal , Insuficiencia Renal Crónica/terapia , Arteria Cubital/cirugía , Extremidad Superior/irrigación sanguínea , Venas/cirugía , Derivación Arteriovenosa Quirúrgica/efectos adversos , Humanos , Isquemia/etiología , Insuficiencia Renal Crónica/diagnóstico , Infección de la Herida Quirúrgica/etiología , Resultado del Tratamiento , Arteria Cubital/fisiopatología , Grado de Desobstrucción Vascular , Venas/fisiopatología
15.
J Vasc Surg ; 62(6): 1652-7, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26483002

RESUMEN

OBJECTIVE: Over several decades, there has been an increase in the number of elderly patients requiring hemodialysis. These older patients typically have an increased incidence of comorbidities including diabetes, hypertension, and peripheral vascular disease. We undertook a systematic review of the current literature to assess outcomes of arteriovenous fistula (AVF) formation in the elderly and to compare the results of radiocephalic AVFs vs brachiocephalic AVFs in older patients. METHODS: A literature search was performed using MEDLINE, Embase, PubMed, and the Cochrane Library. All retrieved articles published before December 31, 2014 (and in English) primarily describing the creation of hemodialysis vascular access for elderly patients were considered for inclusion. We report pooled AVF patency rates and a comparison of radiocephalic vs brachiocephalic AVF patency rates using odds ratios (ORs). RESULTS: Of 199 relevant articles reviewed, 15 were deemed eligible for the review. The pooled 12-month primary and secondary AVF patency rates were 53.6% (95% confidence interval [CI], 47.3-59.9) and 71.6% (95% CI, 59.2-82.7), respectively. Comparison of radiocephalic vs brachiocephalic AVF patency rates demonstrated that radiocephalic AVFs have inferior primary (OR, 0.72; 95% CI, 0.55-0.93; P = .01) and secondary (OR, 0.76; 95% CI, 0.58-1.00; P = .05) patency rates. CONCLUSIONS: This meta-analysis confirms that adequate 12-month primary and secondary AVF patency rates can be achieved in elderly patients. Brachiocephalic AVFs have both superior primary and secondary patency rates at 12 months compared with radiocephalic AVFs. These important data can inform clinicians' and patients' decision-making about suitability of attempting AVF formation in older persons.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Arteria Braquial , Arteria Radial , Grado de Desobstrucción Vascular , Anciano , Derivación Arteriovenosa Quirúrgica/métodos , Humanos , Fallo Renal Crónico/terapia , Diálisis Renal , Resultado del Tratamiento
20.
Clin Transplant ; 28(7): 808-15, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24801162

RESUMEN

BACKGROUND: Deceased kidney donors are increasingly "marginal," and many have risk factors for acute kidney injury (AKI) that may impact on subsequent renal transplant outcome. Despite this, determining the presence of AKI at the time of deceased organ donation remains difficult. METHODS: Urine samples from 182 brainstem dead multi-organ donors (all of whom donated hearts that were transplanted) were analyzed for a Luminex(™) panel of biomarkers linked with AKI. This included KIM-1, NGAL, IFN-γ, TNF-α, cystatin C, Fractalkine and vascular endothelial growth factor. Levels were correlated to early renal transplant outcomes, most specifically delayed graft function. RESULTS: Donor urinary KIM-1 levels were significantly higher in donors whose kidneys displayed aberrant early function (p = 0.011). Fractalkine levels showed a trend toward elevation in such donors but uncorrected this did not attain significance. No correlation occurred with the remaining biomarkers. CONCLUSIONS: KIM-1 appears to show promise as a marker for AKI in deceased cardiac organ donors. The availability of a lateral flow device (Renastick(™) ) for KIM-1 that also demonstrates higher urinary KIM-1 levels in donors whose kidneys show aberrant initial function (p = 0.03), makes KIM-1 a potential indicator of AKI that may merit further evaluation for its application at the donor bedside.


Asunto(s)
Lesión Renal Aguda/orina , Biomarcadores/orina , Trasplante de Riñón , Glicoproteínas de Membrana/orina , Donantes de Tejidos , Adolescente , Adulto , Anciano , Cadáver , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Estudios de Seguimiento , Receptor Celular 1 del Virus de la Hepatitis A , Humanos , Lactante , Masculino , Persona de Mediana Edad , Pronóstico , Receptores Virales , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA