1.
Sensors (Basel) ; 23(2)2023 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-36679702

RESUMEN

Dual mobility (DM) implants are being increasingly used for total hip arthroplasties due to the additional range of motion and joint stability they afford over more traditional implant types. Currently, there are no reported methods for monitoring their motions under realistic operating conditions while in vitro and, therefore, it is challenging to predict how they will function under clinically relevant conditions and what failure modes may exist. This study reports the development, calibration, and validation of a novel inertial tracking system that directly mounts to the mobile liner of DM implants. The tracker was custom built and based on a miniaturized, off-the-shelf inertial measurement unit (IMU) and employed a gradient-decent sensor fusion algorithm for amalgamating nine degree-of-freedom IMU readings into three-axis orientation estimates. Additionally, a novel approach to magnetic interference mitigation using a fixed solenoid and magnetic field simulation was evaluated. The system produced orientation measurements to within 1.0° of the true value under ideal conditions and 3.9° with a negligible drift while in vitro, submerged in lubricant, and without a line of sight.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Movimiento (Física) , Algoritmos , Simulación por Computador , Prótesis e Implantes , Fenómenos Biomecánicos
2.
J Arthroplasty ; 36(11): 3709-3715, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34303582

RESUMEN

BACKGROUND: The risk factors for and clinical impact of radiolucent lines (RLLs) in cementless total hip arthroplasty remain contentious. The aim of this work was to describe a method of classification that has clinical significance and to identify risk factors. METHODS: A cohort of 288 subjects with unrevised Corail stems (DePuy Synthes, Warsaw, IN) were reviewed with radiographs and Oxford Hip Scores at 10 years. Based on clinical experience, three groups were defined; those with no RLLs (NoRLLs), those considered to have benign RLLs (BenRLLs), and those considered to have significant RLLs (SigRLLs). SigRLLs were then compared to BenRLLs and NoRLLs to determine the validity of this classification. RESULTS: One hundred and nine (37.8%) had NoRLLs, 111 (38.5%) had BenRLLs, and 68 (23.6%) had SigRLLs. No significant difference apart from gender was noted between the occurrence of BenRLLs and NoRLLs after multinomial regression analysis, consequently the NoRLLs and BenRLLs groups were combined (NoSigRLLs) and compared to SigRLLs. Non-cross-linked polyethylene (odds ratio = 4.6, P < .001), collarless stem design (odds ratio = 9.4, P < .001), undersizing (odds ratio = 1.2, P = .028), and male sex (odds ratio = 2.1, P = .008) were risk factors for SigRLLs. Regression analysis also revealed that increasing age at operation decreased the likelihood of SigRLLs (P < .001). Patients with SigRLLs had significantly higher pain scores (P = .005) although overall Oxford Hip Scores were not significantly different (P = .364). CONCLUSION: The definition of SigRLLs proposed in this study was significantly associated with that of non-cross-linked polyethylene, absence of a collar, undersizing, and higher pain scores.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Durapatita , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo
3.
J Arthroplasty ; 28(1): 90-7, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22480525

RESUMEN

The clinical incidence of squeaking has been reported with increasing frequency, with ceramic-on-ceramic bearings seemingly most affected. This study investigated potential causes of squeaking in hard-on-hard hip bearings through 2 sets of experimental conditions. Bearing clearance appeared to affect the incidence of squeaking in metal-on-metal surface arthroplasties. The addition of third-body particles to the interface for total hip arthroplasties also affected the incidence of squeaking. In both studies, the incidence of squeaking correlated well with elevated friction. The findings of this study suggest that a likely cause of squeaking in the hip arthroplasty is adverse tribological conditions caused by suboptimal lubrication. There are numerous factors that may cause the suboptimal lubrication, and therefore, it is unlikely that an individual cause for squeaking will be identified.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Fricción , Prótesis de Cadera/efectos adversos , Ruido , Diseño de Prótesis , Cerámica , Humanos , Técnicas In Vitro , Ensayo de Materiales , Metales , Estrés Mecánico , Propiedades de Superficie
4.
Proc Inst Mech Eng H ; 227(4): 345-9, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23637209

RESUMEN

Clinical studies have found high wear rates, elevated ion levels and high revision rates of large-diameter metal-on-metal surface replacement bearings in some patients, which have been associated with edge loading of the head on the rim of the cup. We have simulated increased wear and ion levels in metal-on-metal bearings in vitro by introducing variations in translational and rotational positioning of the components, which reproduces stripe wear on the femoral head, cup rim wear and clinically relevant large as well as small wear particles. There is interest in technologies such as surface engineering, which might reduce metal wear and the release of wear particles and ions. Reduced wear with surface-engineered surface replacements compared to metal-on-metal controls has been reported under standard walking conditions with correctly aligned and concentric components. In this in vitro study, the wear of chromium nitride surface-engineered metal-on-metal bearings under conditions of microseparation associated with translational and rotational malpositioning of the components was investigated and the results were compared with a previously reported study of metal-on-metal bearings under the same conditions. Simulations were conducted using our unique hip simulation microseparation methodologies, which reproduce accelerated wear in metal-on-metal bearings and have previously been clinically validated with ceramic-on-ceramic bearings. Four of the six surface-engineered bearings had evidence of head contact on the rim of the cup, which produced stripe wear on the femoral head. Four of the six surface-engineered bearings (two without stripe and two with stripe wear) had lower wear than the previously reported high wearing metal-on-metal bearings. At 2 million cycles, two of the surface-engineered bearings had substantially increased wear rates, four times higher than the high wear rates previously reported for metal-on-metal bearings under the same conditions. There was wear through and cohesive failure of the thick atomic emission physical vapour deposition (AEPVD) chromium nitride (CrN) coating. At this point, the study was stopped to investigate the failure mode. This study highlights the need to pre-clinically investigate the tribology of new bearings under a wide set of clinical conditions as demonstrated by our stratified approach for enhanced reliability (SAFER) simulation methods. In adopting this SAFER approach to pre-clinical simulation testing of new bearings, it is important to communicate the failures as well as successes of technologies arising from the research, in order that the wider community can benefit from the analysis of the pre-clinical failure modes.


Asunto(s)
Prótesis de Cadera , Metales/química , Artroplastia de Reemplazo de Cadera/métodos , Fenómenos Biomecánicos , Cromo/química , Simulación por Computador , Cabeza Femoral/patología , Ensayo de Materiales , Nitrógeno/química , Diseño de Prótesis , Falla de Prótesis , Reproducibilidad de los Resultados , Estrés Mecánico , Propiedades de Superficie
5.
Proc Inst Mech Eng H ; 237(6): 782-787, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37226516

RESUMEN

Despite their emerging use, the current understanding of the in-vivo functional mechanisms of Dual Mobility (DM) Total Hip Replacements (THRs) is poor, and current characterisation methodologies are not suitable for the unique function and design of these types of devices. Therefore, the aim of this study was to develop a geometric characterisation methodology to estimate dimensional change across the articulating surfaces of retrieved DM polyethylene liners so that their invivo function may be better understood. The method involves the acquisition of three-dimensional coordinate data from the internal and external surfaces of DM liners. The data is processed using a bespoke MATLAB script which approximates the unworn reference geometry of each surface, calculates geometric variance at each point and produces surface deviation heatmaps so that areas of wear and/or deformation may be visualised across the implant. One as-manufactured and five retrieved DM liners were assessed, which demonstrated the efficacy, repeatability and sensitivity of the developed method. This study describes an automated and non-destructive approach for assessing retrieved DM liners of any size and from any manufacturer, which may be used in future research to improve our understanding of their in-vivo function and failure mechanisms.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Diseño de Prótesis , Falla de Prótesis , Polietileno
6.
Proc Inst Mech Eng H ; 226(11): 877-86, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23185958

RESUMEN

Implant malpositioning has been identified as a factor associated with clinical failures of metal-on-metal hip resurfacings (MoMHRs). This study investigated the effect of cup orientation and cup coverage on the contact mechanics (incidence of edge-loading) and range of motion (ROM) of MoMHR. Three generic MoMHRs with differing amounts of cup coverage were considered at various orientations. Contact area and contact pressure at the bearing surface were predicted for each design using finite element (FE) method. The ROM was determined based on the geometry overlap. Edge contact was found at lower angles of inclination (65 degrees) for lower coverage cup designs; however, they also provided the greatest ROM. Conversely, cups with greater coverage did not exhibit edge contact until the cup was more steeply positioned (75 degrees), however ROM was reduced. This study enables both sets of variable to be considered in the design of metal-on-metal bearings in hip.


Asunto(s)
Acetábulo/fisiología , Acetábulo/cirugía , Fémur/fisiología , Fémur/cirugía , Prótesis de Cadera , Metales/química , Modelos Biológicos , Simulación por Computador , Diseño Asistido por Computadora , Análisis de Falla de Equipo , Fricción , Diseño de Prótesis , Propiedades de Superficie
7.
Proc Inst Mech Eng H ; : 9544119211069472, 2022 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-35147063

RESUMEN

Total Hip Arthroplasty (THA) is one of the most common and successful surgical interventions. The survivorship at 10 years for the most commonly used systems is over 95%. However, the incidence of revision is usually much higher in the 0-1 year time period following the intervention. The most common reason for revision in this early time period is dislocation and subluxation, which may be defined as complete or permanent, and partial or temporary loss of contact between the bearing surfaces respectively. This study comprises the development of a geometric model of bone and an in situ total hip replacement, to predict the occurrence and location of bone and component impingement for a wide range of acetabular cup positions and for a series of frequently practiced activities of daily living. The model developed predicts that anterior-superior component impingement is associated with activities that result in posterior dislocation. The incidence may be reduced by increased cup anteversion and inclination. Posterior-inferior component impingement is associated with anterior dislocation activities. Its incidence may be reduced by decreased cup anteversion and inclination. A component impingement-free range was identified, running from when the cup was positioned with 45° inclination and 25° anteversion to 70° inclination and 15°-20° anteversion.

8.
Clin Orthop Relat Res ; 467(9): 2259-65, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19363640

RESUMEN

High wear rates and high patient ion levels have been associated with high (> 55 degrees) cup inclination angles for metal-on-metal surface replacements. Wear rates and patterns have been simulated for ceramic-on-ceramic bearings by applying microseparation to replicate head offset deficiency. We tested 39-mm metal-on-metal surface replacements (n = 5) in a hip simulator with (A) an increased cup inclination angle of 60 degrees and (B) an increased cup inclination angle and microseparation over 2 million cycles. (A) resulted in a ninefold increase in wear rate and (B) resulted in a 17-fold increase in wear rate compared to a standard gait condition study. Wear particles produced under microseparation conditions were larger than those produced under standard conditions but of similar shape (round to oval). The data suggest both head and cup position influence the wear of surface replacements; we believe it likely bearings with high wear either have a high cup inclination angle, an offset deficient head, or a combination of both.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Diseño de Prótesis , Falla de Prótesis , Artroplastia de Reemplazo de Cadera/métodos , Humanos , Ensayo de Materiales , Tamaño de la Partícula , Soporte de Peso
9.
Proc Inst Mech Eng H ; 233(11): 1067-1088, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31466506

RESUMEN

Evaluation and prediction of wear play a key role in product design and material selection of total hip replacements, because wear debris is one of the main causes of loosening and failure. Multifactorial clinical or laboratory studies are high cost and require unfeasible timeframes for implant development. Simulation using finite element methods is an efficient and inexpensive alternative to predict wear and pre-screen various parameters. This article presents a comprehensive literature review of the state-of-the-art finite element modelling techniques that have been applied to evaluate wear in polyethylene hip replacement components. A number of knowledge gaps are identified including the need to develop appropriate wear coefficients and the analysis of daily living activities.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Análisis de Elementos Finitos , Fenómenos Mecánicos , Polietileno , Humanos
10.
J Biomech ; 95: 109296, 2019 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-31431346

RESUMEN

Patient imaging and explant analysis has shown evidence of edge loading of hard-on-hard hip replacements in vivo. Experimental hip simulator testing under edge loading conditions has produced increased, clinically-relevant, wear rates for hard-on-hard bearings when compared to concentric conditions. Such testing, however, is time consuming and costly. A quick running computational edge loading model (Python Edge Loading (PyEL) - quasi-static, rigid, frictionless), capable of considering realistic bearing geometries, was developed. The aim of this study was to produce predictions of separation within the typical experimental measurement error of ∼0.5 mm. The model was verified and validated against comparable finite element (FE) models (including inertia and friction) and pre-existing experimental test data for 56 cases, covering a variety of simulated cup orientations, positions, tissue tensions, and loading environments. The PyEL model agreed well with both the more complex computational modelling and experimental results. From comparison with the FE models, the assumption of no inertia had little effect on the maximum separation prediction. With high contact force cases, the assumption of no friction had a larger effect (up to ∼5% error). The PyEL model was able to predict the experimental maximum separations within ∼0.3 mm. It could therefore be used to optimise an experimental test plan and efficiently investigate a much wider range of scenarios and variables. It could also help explain trends and damage modes seen in experimental testing through identifying the contact locations on the liner that are not easily measured experimentally.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Ensayo de Materiales/métodos , Diseño de Prótesis , Fenómenos Biomecánicos , Cerámica , Simulación por Computador , Fricción , Humanos , Fenómenos Mecánicos , Rotación
11.
Proc Inst Mech Eng H ; 232(12): 1261-1270, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30453840

RESUMEN

Hip simulation is a common technique for pre-clinical evaluation of wear performance of total hip arthroplasty. Standard techniques replicate kinematics of walking patterns of a typical patient. Attention has focussed in developing simulations of other typical patient daily activities to improve accuracy of wear predictions. A method for simulating stop-dwell-start motion during patient walking and the effect on 36-mm metal-on-metal total hip arthroplasty was previously presented by the authors. This study sought to extend the previous work to look at the effect of these conditions on ceramic-on-ceramic, metal-on-polyethylene and ceramic-on-polyethylene bearings. Two stop-dwell-start protocols were used: one reproducing average patient movement patterns and one examining more severe conditions. For all materials tested, no significant increase in wear was observed under average stop-dwell-start conditions, suggesting the bearing types tested are robust to this type of activity. A significant increase in wear was observed for metal-on-metal, metal-on-polyethylene and ceramic-on-polyethylene bearings under severe stop-dwell-start conditions, this was attributed to depletion of lubricant in the bearing during the dwell period. A greater relative increase in wear was observed for metal-on-metal bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings. This may be explained by the contributions of the different lubrication mechanisms in each bearing type. Wear of ceramic-on-ceramic was very low in all tests, suggesting normal measurement variation was masking any effect of the adverse conditions. It was not possible to determine any effect of the different activities. These results emphasise the importance of exploring adverse patient activity simulations. The increase in wear rate associated with an adverse activity such as seen in stop-dwell-start motion, has to be considered in the context of the frequency of the adverse activity cycle relative to other activities such as standard continuous walking, to determine the impact on the total wear in a given time period.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Ensayo de Materiales/instrumentación , Fenómenos Mecánicos , Cerámica , Polietileno
12.
J Biomed Mater Res B Appl Biomater ; 106(4): 1456-1462, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28661563

RESUMEN

Wear and fatigue of polyethylene acetabular cups have been reported to play a role in the failure of total hip replacements. Hip simulator testing under a wide range of clinically relevant loading conditions is important. Edge loading of hip replacements can occur following impingement under extreme activities and can also occur during normal gait, where there is an offset deficiency and/or joint laxity. This study evaluated a hip simulator method that assessed wear and damage in polyethylene acetabular liners that were subjected to edge loading. The liners tested to evaluate the method were a currently manufactured crosslinked polyethylene acetabular liner and an aged conventional polyethylene acetabular liner. The acetabular liners were tested for 5 million standard walking cycles and following this 5 million walking cycles with edge loading. Edge loading conditions represented a separation of the centers of rotation of the femoral head and the acetabular liner during the swing phase, leading to loading of the liner rim on heel strike. Rim damage and cracking was observed in the aged conventional polyethylene liner. Steady-state wear rates assessed gravimetrically were lower under edge loading compared to standard loading. This study supports previous clinical findings that edge loading may cause rim cracking in liners, where component positioning is suboptimal or where material degradation is present. The simulation method developed has the potential to be used in the future to test the effect of aging and different levels of severity of edge loading on a range of cross-linked polyethylene materials. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1456-1462, 2018.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Ensayo de Materiales/métodos , Polietileno , Diseño de Prótesis , Acetábulo , Prótesis de Cadera , Humanos , Propiedades de Superficie
13.
J Biomed Mater Res B Appl Biomater ; 81(2): 508-15, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17041924

RESUMEN

Metal-on-ultra-high molecular weight polyethylene (UHMWPE) total hip replacements have been the most popular and clinically successful implants to date. However, it is well documented that the wear debris from these prostheses contributes to osteolysis and ultimate failure of the prosthesis, hence alternative materials have been sought. A range of 28 mm diameter bearings were investigated using a hip friction simulator, including conventional material combinations such as metal-on-UHWMPE, ceramic-on-ceramic (CoC), and metal-on-metal (MoM), as well as novel ceramic-on-metal (CoM) pairings. Studies were performed under different swing-phase load and lubricant conditions. The friction factors were lowest in the ceramic bearings, with the CoC bearing having the lowest friction factor in all conditions. CoM bearings also had low friction factors compared with MoM, and the trends were similar to CoC bearings for all test conditions. Increasing swing phase load was shown to cause an increase in friction factor in all tests. Increased serum concentration resulted in increased friction factor in all material combinations, except MoM, where increased serum concentration produced a significant reduction in friction factor.


Asunto(s)
Prótesis de Cadera , Materiales Biocompatibles , Fenómenos Biomecánicos , Cerámica , Fricción , Humanos , Técnicas In Vitro , Ensayo de Materiales/instrumentación , Ensayo de Materiales/métodos , Metales , Polietilenos , Estrés Mecánico
14.
Proc Inst Mech Eng H ; 231(8): 683-690, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28393608

RESUMEN

There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm3 with the consequent median value for metal-on-metal taper loss being 1.75 mm3. This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm3. Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.


Asunto(s)
Cabeza Femoral , Prótesis Articulares de Metal sobre Metal , Polietileno/química , Anciano , Artroplastia de Reemplazo de Cadera , Corrosión , Femenino , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Propiedades de Superficie
15.
J Biomed Mater Res B Appl Biomater ; 101(5): 770-5, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23359608

RESUMEN

Ceramic-on-metal (COM) hip replacements, where the head is BIOLOX® Delta ceramic and the liner is CoCrMo alloy, have demonstrated reduced wear under standard simulator conditions compared to metal-on-metal (MOM) bearings. COM hips are now being used clinically around the world. MOM hip resurfacings have raised concerns regarding poor clinical performance and increased in vivo wear was associated with steeply inclined acetabular components and translationally malpositioned components. The aim of this study was to compare the wear rates of MOM and COM total hip prostheses under adverse edge-loading conditions in a hip simulator test. COM and MOM 36 mm hip prostheses were tested in a hip simulator, with liners mounted to provide a clinical inclination angle of 55°. A simplified gait cycle and microseparation conditions were applied for two million cycles in 25% new born calf serum. The overall mean volumetric wear rate of COM bearings under adverse conditions was 0.36 ± 0.55 mm³/million cycles; this was significantly less than MOM wear (1.32 ± 0.91 mm³/million cycles). Under these adverse conditions; the contact zone on the head intersects the rim of the cup causing substantially elevated contact stresses, disrupting the protective boundary and mixed lubrication regime causing changes in types and severity of wear mechanisms. In COM bearings, the harder head does not become damaged when there is lubricant starvation and wear does not accelerate. In conclusion, COM bearings showed reduced wear compared to MOM bearings under standard and adverse clinically relevant simulator conditions and COM bearings may provide an advantage over MOM bearings under edge-loading conditions clinically.


Asunto(s)
Cerámica , Prótesis de Cadera , Falla de Prótesis , Vitalio , Materiales Biocompatibles , Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/métodos , Prótesis de Cadera/efectos adversos , Humanos , Lubricantes , Ensayo de Materiales , Diseño de Prótesis/efectos adversos , Propiedades de Superficie
16.
J Biomed Mater Res B Appl Biomater ; 100(6): 1459-65, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22454322

RESUMEN

Total hip replacement has been a successful surgical intervention for over 50 years, with the majority of bearings using a polyethylene cup. Long-term failure due to osteolysis and loosening has been widely documented and alternative bearings have been sought. A novel carbon fiber-reinforced poly-ether ether ketone (CFR-PEEK) cup was investigated through experimental friction and wear studies. Friction studies demonstrated the bearings operated in a boundary lubrication condition, with friction factors higher than those for other hip replacement bearings. The wear study was conducted with 36 mm diameter bearings tested against Biolox Delta heads for a period of 10 million cycles. The mean volumetric wear rate was 0.3 mm(3)/Mc, indicating the ceramic-on-CFR-PEEK bearing to be a very low wearing option for total hip replacement.


Asunto(s)
Carbono , Cerámica , Prótesis de Cadera , Cetonas , Ensayo de Materiales , Polietilenglicoles , Benzofenonas , Fibra de Carbono , Fricción , Humanos , Polímeros , Soporte de Peso
17.
J Biomed Mater Res B Appl Biomater ; 90(2): 558-65, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19195030

RESUMEN

Increased patient blood and serum levels of Co and Cr and dissemination of metal wear particles throughout organs and tissues are the primary concerns with metal-on-metal surface replacements. Surface engineering, providing a ceramic bearing surface on a metal substrate, could provide a solution. This study investigated thick (>10 microm) arc evaporation plasma vapor deposition chromium nitride (CrN) coated surface replacements in terms of wear, ion levels, and wear particles in a 10 million cycle hip simulator study, compared to a contemporary metal-on-metal surface replacement. The ion levels were measured by inductively coupled plasma mass spectroscopy. The wear particles were imaged by field emission gun scanning electron microscopy. The CrN-coated bearings had 80% lower wear than the MoM controls. The Cr and Co ion levels in the lubricant of the CrN bearings were 73 and 98% lower than in the MoM controls. The wear particles produced were in the nanometer size range and round to oval in morphology. The CrN coating could provide a reduction in the wear and ion release of MoM surface replacements, thereby reducing the perceived risks to the patient associated with these prostheses.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Cerámica/química , Cromo/química , Materiales Biocompatibles Revestidos/química , Cobalto/química , Prótesis de Cadera , Humanos , Iones , Ensayo de Materiales , Metales/química , Microscopía Electrónica de Rastreo/métodos , Compuestos de Nitrógeno/química , Diseño de Prótesis , Falla de Prótesis , Propiedades de Superficie
18.
Hip Int ; 19(4): 330-7, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-20041379

RESUMEN

Seventy-seven patients implanted with unilateral resurfacing prosthesis were recruited from four centres. Serial whole blood samples were collected and ion levels were analysed. In most cases, the ion levels stabilized by 3 months. The 24 month median ion levels were 1.49ug/l for chromium and cobalt. In approximately 50% of patients the increase in chromium and cobalt level was less than 1ug/l. There were 6 patients with abnormally high metal ion levels. Of these 4 were significant outliers, had high ion levels that became apparent between 12 and 24 months after implantation, and had a high cup abduction angle. Not all patients with high cup abduction angles demonstrated high levels. There were differences in ion levels between the four centres that correlated with variation in acetabular component placement. Variability in ion levels was seen with the same prosthesis, underscoring the importance of surgical technique, longitudinal analysis, and multi-centre trials.


Asunto(s)
Cromo/sangre , Cobalto/sangre , Prótesis de Cadera/efectos adversos , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Estudios Prospectivos , Ajuste de Prótesis
19.
Clin Orthop Relat Res ; 466(2): 366-72, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18196419

RESUMEN

UNLABELLED: In vitro studies demonstrating excessive wear in polyethylene cups sterilized using gamma irradiation and stored in air led to the abandonment of this sterilization technique. We evaluated the clinical wear performance of a metal femoral component on a polyethylene cup in a hip prosthesis from a selected subset of implants in a group of patients followed for at least 20 years and assessed the time dependency of variation in penetration rates. We measured penetration in 33 polyethylene cups in 25 patients who had a Charnley low-friction arthroplasty between 1982 and 1984. All patients had Charnley Ogee cups implanted for more than 20 years and sterilized using the gamma irradiation in air technique. If degradation occurred over time in vivo, it was not reflected by an increased penetration rate with increasing time in vivo; even after 20 years of implantation, the degree of wear remained low. This suggests gamma irradiation affects wear on ultra-high-molecular-weight polyethylene by reducing wear secondary to the crosslinking, by increasing wear as shown through in vitro studies of heavily oxidized samples, or by oxidation resulting from prolonged shelf life. The effect of progressive oxidation in vivo does not appear to affect wear in vivo. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Polietileno , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artrografía/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Falla de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
20.
J Bone Joint Surg Am ; 90 Suppl 3: 111-7, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18676945

RESUMEN

BACKGROUND: Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. METHODS: Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. RESULTS: A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. CONCLUSIONS: These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.


Asunto(s)
Prótesis de Cadera , Fenómenos Biomecánicos , Cabeza Femoral , Fricción , Humanos , Diseño de Prótesis , Falla de Prótesis , Vitalio