Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Nano Lett ; 20(7): 4872-4881, 2020 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-32364743

RESUMEN

Here we demonstrate an unconventional fabrication of highly transparent supercapacitors and electrodes using random networks of nanostructured metallic glass nanotroughs for their integrations as wirelessly rechargeable and invisible, skin heat patches. Transparent supercapacitors with fine conductive patterns were printed using an electrohydrodynamic jet-printing. Also, transparent and stretchable electrodes, for wireless antennas, heaters and interconnects, were formed using random network based on nanostructured CuZr nanotroughs and Ag nanowires with superb optoelectronic properties (sheet resistance of 3.0 Ω/sq at transmittance of 91.1%). Their full integrations, as an invisible heat patch on skin, enabled the wireless recharge of supercapacitors and the functions of heaters for thermal therapy of skin tissue. The demonstration of this transparent thermotherapy patch to control the blood perfusion level and hydration rate of skin suggests a promising strategy toward next-generation wearable electronics.


Asunto(s)
Nanoestructuras , Nanocables , Electrodos , Electrónica , Calor
2.
Nano Lett ; 20(1): 66-74, 2020 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-31639307

RESUMEN

Tactile pressure sensors as flexible bioelectronic devices have been regarded as the key component for recently emerging applications in electronic skins, health-monitoring devices, or human-machine interfaces. However, their narrow range of sensible pressure and their difficulty in forming high integrations represent major limitations for various potential applications. Herein, we report fully integrated, active-matrix arrays of pressure-sensitive MoS2 transistors with mechanoluminescent layers and air dielectrics for wide detectable range from footsteps to cellular motions. The inclusion of mechanoluminescent materials as well as air spaces can increase the sensitivity significantly over entire pressure regimes. In addition, the high integration capability of these active-matrix sensory circuitries can enhance their spatial resolution to the level sufficient to analyze the pressure distribution in a single cardiomyocyte. We envision that these wide-range pressure sensors will provide a new strategy toward next-generation electronics at biomachine interfaces to monitor various mechanical and biological phenomena at single-cell resolution.


Asunto(s)
Molibdeno/química , Transistores Electrónicos , Humanos
3.
Sensors (Basel) ; 20(13)2020 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-32605148

RESUMEN

In recent years, to develop more spontaneous and instant interfaces between a system and users, technology has evolved toward designing efficient and simple gesture recognition (GR) techniques. As a tool for acquiring human motion, a tactile sensor system, which converts the human touch signal into a single datum and executes a command by translating a bundle of data into a text language or triggering a preset sequence as a haptic motion, has been developed. The tactile sensor aims to collect comprehensive data on various motions, from the touch of a fingertip to large body movements. The sensor devices have different characteristics that are important for target applications. Furthermore, devices can be fabricated using various principles, and include piezoelectric, capacitive, piezoresistive, and field-effect transistor types, depending on the parameters to be achieved. Here, we introduce tactile sensors consisting of field-effect transistors (FETs). GR requires a process involving the acquisition of a large amount of data in an array rather than a single sensor, suggesting the importance of fabricating a tactile sensor as an array. In this case, an FET-type pressure sensor can exploit the advantages of active-matrix sensor arrays that allow high-array uniformity, high spatial contrast, and facile integration with electrical circuitry. We envision that tactile sensors based on FETs will be beneficial for GR as well as future applications, and these sensors will provide substantial opportunities for next-generation motion sensing systems.

4.
Nano Lett ; 16(1): 471-8, 2016 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-26670378

RESUMEN

Mechanical robustness, electrical and chemical reliabilities of devices against large deformations such as bending and stretching have become the key metrics for rapidly emerging wearable electronics. Metallic glasses (MGs) have high elastic limit, electrical conductivity, and corrosion resistance, which can be promising for applications in wearable electronics. However, their applications in wearable electronics or transparent electrodes have not been extensively explored so far. Here, we demonstrate stretchable and transparent electrodes using CuZr MGs in the form of nanotrough networks. MG nanotroughs are prepared by electrospinning and cosputtering process, and they can be transferred to various desired substrates, including stretchable elastomeric substrates. The resulting MG nanotrough network is first utilized as a stretchable transparent electrode, presenting outstanding optoelectronic (sheet resistance of 3.8 Ω/sq at transmittance of 90%) and mechanical robustness (resistance change less than 30% up to a tensile strain of 70%) as well as excellent chemical stability against hot and humid environments (negligible degradation in performance for 240 h in 85% relative humidity and 85 °C). A stretchable and transparent heater based on the MG nanotrough network is also demonstrated with a wide operating temperature range (up to 180 °C) and excellent stretchability (up to 70% in the strain). The excellent mechanical robustness of these stretchable transparent electrode and heater is ascribed to the structural configuration (i.e., a nanotrough network) and inherent high elastic limit of MGs, as supported by experimental results and numerical analysis. We demonstrate their real-time operations on human skin as a wearable, transparent thermotherapy patch controlled wirelessly using a smartphone as well as a transparent defroster for an automobile side-view mirror, suggesting a promising strategy toward next-generation wearable electronics or automobile applications.

5.
Nat Nanotechnol ; 19(5): 688-697, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38225357

RESUMEN

Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 µm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium-indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm-2) to elicit neural responses in the retina. Their low Young's modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.


Asunto(s)
Microelectrodos , Prótesis Visuales , Prótesis Visuales/química , Animales , Ratones , Células Ganglionares de la Retina/fisiología , Degeneración Retiniana/terapia , Degeneración Retiniana/patología , Retina , Electrodos Implantados , Platino (Metal)/química
6.
Lab Chip ; 21(7): 1269-1286, 2021 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-33704299

RESUMEN

The eye is a complex sensory organ that contains abundant information for specific diseases and pathological responses. It has emerged as a facile biological interface for wearable healthcare platforms because of its excellent accessibility. Recent advances in electronic devices have led to the extensive research of point-of-care (POC) systems for diagnosing and monitoring diseases by detecting the biomarkers within the eye. Among these systems, contact lenses, which make direct contact with the ocular surfaces, have been utilized as one of the promising candidates for non-invasive POC testing of various diseases. The continuous and long-term measurement from the sensor allows the patients to manage their symptoms in an effective and convenient way. Herein, we review the progress of contact lens sensors in terms of the materials, methodologies, device designs, and target biomarkers. The anatomical structure and biological mechanisms of the eye are also discussed to provide a comprehensive understanding of the principles of contact lens sensors. Intraocular pressure and glucose, which are the representative biomarkers found in the eyes, can be measured with the biosensors integrated with contact lenses for the diagnosis of glaucoma and diabetes. Furthermore, contact lens sensors for various general pathologies as well as other ocular diseases are also considered, thereby providing the prospects for further developments of smart contact lenses as a future POC system.


Asunto(s)
Técnicas Biosensibles , Lentes de Contacto , Dispositivos Electrónicos Vestibles , Humanos , Presión Intraocular , Sistemas de Atención de Punto
7.
Adv Healthc Mater ; 10(17): e2002280, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33724723

RESUMEN

Wearable healthcare devices have garnered substantial interest for the realization of personal health management by monitoring the physiological parameters of individuals. Attaining the integrity between the devices and the biological interfaces is one of the greatest challenges to achieving high-quality body information in dynamic conditions. Liquid metals, which exist in the liquid phase at room temperatures, are advanced intensively as conductors for deformable devices because of their excellent stretchability and self-healing ability. The unique surface chemistry of liquid metals allows the development of various sensors and devices in wearable form. Also, the biocompatibility of liquid metals, which is verified through numerous biomedical applications, holds immense potential in uses on the surface and inside of a living body. Here, the recent progress of liquid metal-based wearable electronic devices for healthcare with respect to the featured properties and the processing technologies is discussed. Representative examples of applications such as biosensors, neural interfaces, and a soft interconnection for devices are reviewed. The current challenges and prospects for further development are also discussed, and the future directions of advances in the latest research are explored.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Atención a la Salud , Electrónica , Humanos , Metales
8.
Adv Mater ; 33(30): e2101093, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34142400

RESUMEN

Despite recent substantial advances in perovskite materials, their 3D integration capability for next-generation electronic devices is limited owing to their inherent vulnerability to heat and moisture with degradation of their remarkable optoelectronic properties during fabrication processing. Herein, a facile method to transfer the patterns of perovskites to planar or nonplanar surfaces using a removable polymer is reported. After fabricating perovskite devices on this removable polymer film, the conformal attachment of this film on target surfaces can place the entire devices on various substrates by removing this sacrificial film. This transfer method enables the formation of a perovskite image sensor array on a soft contact lens, and in vivo tests using rabbits demonstrate its wearability. Furthermore, 3D heterogeneous integration of a perovskite photodetector array with an active-matrix array of pressure-sensitive silicon transistors using this transfer method demonstrates the formation of a multiplexed sensing platform detecting distributions of light and tactile pressure simultaneously.

9.
Adv Mater ; 33(30): e2008539, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34145641

RESUMEN

Visual and tactile information are the key intuitive perceptions in sensory systems, and the synchronized detection of these two sensory modalities can enhance accuracy of object recognition by providing complementary information between them. Herein, multimodal integration of flexible, high-resolution X-ray detectors with a synchronous mapping of tactile pressure distributions for visualizing internal structures and morphologies of an object simultaneously is reported. As a visual-inspection method, perovskite materials that convert X-rays into charge carriers directly are synthesized. By incorporating pressure-sensitive air-dielectric transistors in the perovskite components, X-ray detectors with dual modalities (i.e., vision and touch) are attained as an active-matrix platform for digital visuotactile examinations. Also, in vivo X-ray imaging and pressure sensing are demonstrated using a live rat. This multiplexed platform has high spatial resolution and good flexibility, thereby providing highly accurate inspection and diagnoses even for the distorted images of nonplanar objects.

10.
Sci Adv ; 7(14)2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33789904

RESUMEN

Wearable electronic devices that can monitor physiological signals of the human body to provide biomedical information have been drawing extensive interests for sustainable personal health management. Here, we report a human pilot trial of a soft, smart contact lens and a skin-attachable therapeutic device for wireless monitoring and therapy of chronic ocular surface inflammation (OSI). As a diagnostic device, this smart contact lens enables real-time measurement of the concentration of matrix metalloproteinase-9, a biomarker for OSI, in tears using a graphene field-effect transistor. As a therapeutic device, we also fabricated a stretchable and transparent heat patch attachable on the human eyelid conformably. Both diagnostic and therapeutic devices can be incorporated using a smartphone for their wireless communications, thereby achieving instantaneous diagnosis of OSI and automated hyperthermia treatments. Furthermore, in vivo tests using live animals and human subjects confirm their good biocompatibility and reliability as a noninvasive, mobile health care solution.

11.
Sci Adv ; 4(1): eaap9841, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29387797

RESUMEN

Recent advances in wearable electronics combined with wireless communications are essential to the realization of medical applications through health monitoring technologies. For example, a smart contact lens, which is capable of monitoring the physiological information of the eye and tear fluid, could provide real-time, noninvasive medical diagnostics. However, previous reports concerning the smart contact lens have indicated that opaque and brittle components have been used to enable the operation of the electronic device, and this could block the user's vision and potentially damage the eye. In addition, the use of expensive and bulky equipment to measure signals from the contact lens sensors could interfere with the user's external activities. Thus, we report an unconventional approach for the fabrication of a soft, smart contact lens in which glucose sensors, wireless power transfer circuits, and display pixels to visualize sensing signals in real time are fully integrated using transparent and stretchable nanostructures. The integration of this display into the smart lens eliminates the need for additional, bulky measurement equipment. This soft, smart contact lens can be transparent, providing a clear view by matching the refractive indices of its locally patterned areas. The resulting soft, smart contact lens provides real-time, wireless operation, and there are in vivo tests to monitor the glucose concentration in tears (suitable for determining the fasting glucose level in the tears of diabetic patients) and, simultaneously, to provide sensing results through the contact lens display.


Asunto(s)
Técnicas Biosensibles/métodos , Lentes de Contacto , Glucosa/análisis , Tecnología Inalámbrica , Humanos
12.
Adv Mater ; 29(24)2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28417599

RESUMEN

Various wearable electronic devices have been developed for extensive outdoor activities. The key metrics for these wearable devices are high touch sensitivity and good mechanical and thermal stability of the flexible touchscreen panels (TSPs). Their dielectric constants (k) are important for high touch sensitivities. Thus, studies on flexible and transparent cover layers that have high k with outstanding mechanical and thermal reliabilities are essential. Herein, an unconventional approach for forming flexible and transparent cellulose nanofiber (CNF) films is reported. These films are used to embed ultralong metal nanofibers that serve as nanofillers to increase k significantly (above 9.2 with high transmittance of 90%). Also, by controlling the dimensions and aspect ratios of these fillers, the effects of their nanostructures and contents on the optical and dielectric properties of the films have been studied. The length of the nanofibers can be controlled using a stretching method to break the highly aligned, ultralong nanofibers. These nanofiber-embedded, high-k films are mechanically and thermally stable, and they have better Young's modulus and tensile strength with lower thermal expansion than commercial transparent plastics. The demonstration of highly sensitive TSPs using high-k CNF film for smartphones suggests that this film has significant potential for next-generation, portable electronic devices.

13.
Polymers (Basel) ; 9(8)2017 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-30970981

RESUMEN

Wearable human interaction devices are technologies with various applications for improving human comfort, convenience and security and for monitoring health conditions. Healthcare monitoring includes caring for the welfare of every person, which includes early diagnosis of diseases, real-time monitoring of the effects of treatment, therapy, and the general monitoring of the conditions of people's health. As a result, wearable electronic devices are receiving greater attention because of their facile interaction with the human body, such as monitoring heart rate, wrist pulse, motion, blood pressure, intraocular pressure, and other health-related conditions. In this paper, various smart sensors and wireless systems are reviewed, the current state of research related to such systems is reported, and their detection mechanisms are compared. Our focus was limited to wearable and attachable sensors. Section 1 presents the various smart sensors. In Section 2, we describe multiplexed sensors that can monitor several physiological signals simultaneously. Section 3 provides a discussion about short-range wireless systems including bluetooth, near field communication (NFC), and resonance antenna systems for wearable electronic devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA