Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cancer Educ ; 38(2): 578-589, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35359258

RESUMEN

To evaluate the educational impact on radiation oncology residents in training when introducing an automatic segmentation software in head and neck cancer patients regarding organs at risk (OARs) and prophylactic cervical lymph node level (LNL) volumes. Two cases treated by exclusive intensity-modulated radiotherapy were delineated by an expert radiation oncologist and were considered as reference. Then, these cases were delineated by residents divided into two groups: group 1 (control group), experienced residents delineating manually, group 2 (experimental group), young residents on their first rotation trained with automatic delineation, delineating manually first (M -) and then after using the automatic system (M +). The delineation accuracy was assessed using the Overlap Volume (OV). Regarding the OARs, mean OV was 0.62 (SD = 0.05) for group 1, 0.56 (SD = 0.04) for group 2 M - , and 0.61 (SD = 0.03) for group 2 M + . Mean OV was higher in group 1 compared to group 2 M - (p = 0.01). There was no OV difference between group 1 and group 2 M + (p = 0.67). Mean OV was higher in the group 2 M + compared to group 2 M - (p < 0.003). Regarding LNL, mean OV was 0.53 (SD = 0.06) in group 1, 0.54 (SD = 0.03) in group 2 M - , and 0.58 (SD = 0.04) in group 2 M + . Mean OV was higher in group 2 M + for 11 of the 12 analysed structures compared to group 2 M - (p = 0.016). Prior use of the automatic delineation software reduced the average contouring time per case by 34 to 40%. Prior use of atlas-based automatic segmentation reduces the delineation duration, and provides reliable OARs and LNL delineations.


Asunto(s)
Neoplasias de Cabeza y Cuello , Oncología por Radiación , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador , Neoplasias de Cabeza y Cuello/radioterapia , Órganos en Riesgo
2.
Radiat Environ Biophys ; 61(4): 651-660, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36098818

RESUMEN

In this paper, a dosimetric end-to-end test of respiratory gated radiation therapy (RGRT) applied in lung cancer stereotactic body radiation therapy (SBRT) was performed. The test was performed from treatment simulation to treatment delivery using a QUASAR phantom, for regular, slightly irregular and irregular breathing patterns in phase- and amplitude-gated modes. A mechanical and dosimetric verification was performed to evaluate all steps of the proposed treatment workflow. Dose measurements were performed using a PinPoint ion chamber and GafChromic EBT3 films. Mechanical verification confirmed good function of the chosen systems. Dosimetric verification showed good agreement between planned and measured doses, for the phase-gated versus amplitude-gated modes: 1.4 ± 0.4% versus 1.2 ± 0.2% for regular, 2.8 ± 0.3% versus 3.0 ± 0.3% for slightly irregular, and 6.2 ± 0.7% versus 7.4 ± 0.5% for irregular breathing patterns. The gamma passing rates for 3%/3 mm and 2%/2 mm criteria, comparing phase- versus amplitude-gated modes, were 99.0 ± 0.3% versus 99.5 ± 0.2% and 95.2 ± 0.2% versus 96.1 ± 0.2% for the regular, 97.4 ± 0.8% versus 98.0 ± 0.6% and 91.7 ± 0.5% versus 92.4 ± 0.4% for the slightly irregular, and 96.4 ± 0.5% versus 95.3 ± 0.7% and 86.4 ± 0.5% versus 84.6 ± 0.7% for the irregular breathing patterns, respectively. It is concluded that using equipment and workflow for the treatment of lung cancer by means of SBRT in RGRT mode is safe and efficient, for regular and slightly irregular breathing patterns.


Asunto(s)
Neoplasias Pulmonares , Radiocirugia , Humanos , Planificación de la Radioterapia Asistida por Computador , Dosificación Radioterapéutica , Respiración , Fantasmas de Imagen , Pulmón , Neoplasias Pulmonares/radioterapia
3.
Phys Imaging Radiat Oncol ; 30: 100591, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38832123

RESUMEN

Background and purpose: Stereotactic radiation therapy (SRT) is commonly used to treat brain metastases (BMs). This retrospective study compared two SRT techniques, dynamic conformal arc therapy (DCAT) and volumetric modulated arc therapy (VMAT), for single BM treatments. Material and methods: Data of patients treated between January 2010 and June 2020 were considered. Patients with multiple BMs, resected BMs, reirradiation, whole-brain radiation therapy and brainstem metastases were excluded. We focused our analysis on 97 patients who received 23.1 Gy in three fractions. Acute toxicities and follow-up outcomes were recorded. Dosimetric data were analyzed in two subgroups (PTV ≤ 10 cc and PTV > 10 cc). Results: DCAT and VMAT were used in 70 (72.2 %) and 27 (27.8 %) patients, respectively. Acute toxicities were not significantly different between groups (p = 0.259), and no difference was detected in the incidence rate of radionecrosis, local recurrence and cerebral recurrence (p > 0.999, p > 0.999 and p = 0.682, respectively). PTV coverage was better with DCAT for small volumes (PTV ≤ 10 cc). Mean conformity index (CI) was significantly higher with VMAT and mean gradient index (GI) was significantly lower with DCAT whatever volume subgroups (p < 0.001). DCAT had more heterogeneous plans and VMAT required more monitor units. DCAT resulted in reduced low and intermediate doses, whereas VMAT led to decreased high doses. Conclusion: DCAT and VMAT are two effective and safe SRT techniques for BMs treatment. In the era of re-irradiation, it is important to reduce the doses delivered to healthy tissues. Further prospective studies are needed to validate these findings.

4.
Radiat Oncol ; 19(1): 40, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38509543

RESUMEN

PURPOSE: To assess a large panel of MR compatible detectors on the full range of measurements required for a 0.35 T MR-linac commissioning by using a specific statistical method represented as a continuum of comparison with the Monte Carlo (MC) TPS calculations. This study also describes the commissioning tests and the secondary MC dose calculation validation. MATERIAL AND METHODS: Plans were created on the Viewray TPS to generate MC reference data. Absolute dose points, PDD, profiles and output factors were extracted and compared to measurements performed with ten different detectors: PTW 31010, 31021, 31022, Markus 34045 and Exradin A28 MR ionization chambers, SN Edge shielded diode, PTW 60019 microdiamond, PTW 60023 unshielded diode, EBT3 radiochromic films and LiF µcubes. Three commissioning steps consisted in comparison between calculated and measured dose: the beam model validation, the output calibration verification in four different phantoms and the commissioning tests recommended by the IAEA-TECDOC-1583. MAIN RESULTS: The symmetry for the high resolution detectors was higher than the TPS data of about 1%. The angular responses of the PTW 60023 and the SN Edge were - 6.6 and - 11.9% compared to the PTW 31010 at 60°. The X/Y-left and the Y-right penumbras measured by the high resolution detectors were in good agreement with the TPS values except for the PTW 60023 for large field sizes. For the 0.84 × 0.83 cm2 field size, the mean deviation to the TPS of the uncorrected OF was - 1.7 ± 1.6% against - 4.0 ± 0.6% for the corrected OF whereas we found - 4.8 ± 0.8% for passive dosimeters. The mean absolute dose deviations to the TPS in different phantoms were 0 ± 0.4%, - 1.2 ± 0.6% and 0.5 ± 1.1% for the PTW 31010, PTW 31021 and Exradin A28 MR respectively. CONCLUSIONS: The magnetic field effects on the measurements are considerably reduced at low magnetic field. The PTW 31010 ionization chamber can be used with confidence in different phantoms for commissioning and QA tests requiring absolute dose verifications. For relative measurements, the PTW 60019 presented the best agreement for the full range of field size. For the profile assessment, shielded diodes had a behaviour similar to the PTW 60019 and 60023 while the ionization chambers were the most suitable detectors for the symmetry. The output correction factors published by the IAEA TRS 483 seem to be applicable at low magnetic field pending the publication of new MR specific values.


Asunto(s)
Aceleradores de Partículas , Radiometría , Humanos , Radiometría/métodos , Método de Montecarlo , Fantasmas de Imagen , Calibración
5.
Neuroradiology ; 55(11): 1379-87, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24085324

RESUMEN

INTRODUCTION: The aim of this study was to compare the sensitivity of intra-aortic computed tomography angiography (IA-CTA) to that of regular spinal digital subtraction angiography for the presurgical location of the Adamkiewicz artery (AKA). METHODS: Thirty patients (21 males, 9 females; mean age 64 years) had an IA-CTA for the location of the AKA before surgery of aneurysm (n = 24) or dissection (n = 6) of the thoracoabdominal aorta. After femoral artery puncture, a pigtail catheter was positioned at the origin of the descending aorta. CT acquisition was performed with an intra-aortic iodinated contrast media injection (15 mL/s, 120 mL). The visualization of the AKA and the location of the feeder(s) to the AKA were independently evaluated by two observers. Interrater agreement was calculated using a kappa test. Spinal angiogram by selective catheterization was systematically performed to confirm the results of the IA-CTA. RESULTS: The AKA was visualized by the IA-CTA in 27/30 cases (90 %); in 26/31 (84 %) cases, the continuity with the aorta was satisfactorily seen. Interrater agreement was good for the visualization of the AKA and its feeder(s): 0.625 and 0.87, respectively. In 75 % of the cases for which the AKA was visualized, the selective catheterization confirmed the results of the IA-CTA. In the remaining 25 % of the cases, the selective catheterization could not be performed due to marked vessels' tortuosity or ostium stenosis. CONCLUSION: IA-CTA is a feasible technique in a daily practice that presents a good sensitivity for the location of the AKA.


Asunto(s)
Aneurisma Roto/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Cuidados Preoperatorios/métodos , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Aneurisma Roto/cirugía , Aneurisma de la Aorta Torácica/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Cancers (Basel) ; 15(15)2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37568753

RESUMEN

Stereotactic radiotherapy (SRT) plays a major role in treating brain metastases (BMs) and can be delivered using various equipment and techniques. This review aims to identify the dosimetric factors of each technique to determine whether one should be preferred over another for single BMs treatment. A systematic literature review on articles published between January 2015 and January 2022 was conducted using the MEDLINE and ScienceDirect databases, following the PRISMA methodology, using the keywords "dosimetric comparison" and "brain metastases". The included articles compared two or more SRT techniques for treating single BM and considered at least two parameters among: conformity (CI), homogeneity (HI) and gradient (GI) indexes, delivery treatment time, and dose-volume of normal brain tissue. Eleven studies were analyzed. The heterogeneous lesions along with the different definitions of dosimetric indexes rendered the studied comparison almost unattainable. Gamma Knife (GK) and volumetric modulated arc therapy (VMAT) provide better CI and GI and ensure the sparing of healthy tissue. To conclude, it is crucial to optimize dosimetric indexes to minimize radiation exposure to healthy tissue, particularly in cases of reirradiation. Consequently, there is a need for future well-designed studies to establish guidelines for selecting the appropriate SRT technique based on the treated BMs' characteristics.

7.
Radiat Oncol ; 16(1): 45, 2021 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-33639959

RESUMEN

PURPOSE: To compare linac-based mono-isocentric radiosurgery with Brainlab Elements Multiple Brain Mets (MBM) SRS and the Gamma Knife using a specific statistical method and to analyze the dosimetric impact of the target volume geometric characteristics. A dose fall-off analysis allowed to evaluate the Gradient Index relevancy for the dose spillage characterization. MATERIAL AND METHODS: Treatments were planned on twenty patients with three to nine brain metastases with MBM 2.0 and GammaPlan 11.0. Ninety-five metastases ranging from 0.02 to 9.61 cc were included. Paddick Index (PI), Gradient Index (GI), dose fall-off, volume of healthy brain receiving more than 12 Gy (V12Gy) and DVH were used for the plan comparison according to target volume, major axis diameter and Sphericity Index (SI). The multivariate regression approach allowed to analyze the impact of each geometric characteristic keeping all the others unchanged. A parallel study was led to evaluate the impact of the isodose line (IDL) prescription on the MBM plan quality. RESULTS: For mono-isocentric linac-based radiosurgery, the IDL around 70-75% was the best compromise found. For both techniques, the GI and the dose fall-off decreased with the target volume. In comparison, PI was slightly improved with MBM for targets < 1 cc or SI > 0.78. GI was improved with GP for targets < 2.5 cc. The V12Gy was higher with MBM for lesions > 0.4 cc or SI < 0.84 and exceeded 10 cc for targets > 5 cc against 6.5 cc with GP. The presence of OAR close to the PTV had no impact on the dose fall off values. The dose fall-off was higher for volumes < 3.8 cc with GP which had the sharpest dose fall-off in the infero-superior direction up to 30%/mm. The mean beam-on time was 94 min with GP against 13 min with MBM. CONCLUSIONS: The dose fall-off and the V12Gy were more relevant indicators than the GI for the low dose spillage assessment. Both evaluated techniques have comparable plan qualities with a slightly improved selectivity with MBM for smaller lesions but with a healthy tissues sparing slightly favorable to GP at the expense of a considerably longer irradiation time. However, a higher healthy tissue exposure must be considered for large volumes in MBM plans.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Encéfalo/efectos de la radiación , Neoplasias Encefálicas/patología , Humanos , Órganos en Riesgo/efectos de la radiación , Radiometría , Dosificación Radioterapéutica
8.
Arch Cardiovasc Dis ; 114(2): 140-149, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33478860

RESUMEN

Ventricular tachycardia has a significant recurrence rate after ablation for several reasons, including inaccessible substrate. A non-invasive technique to ablate any defined areas of myocardium involved in arrhythmogenesis would be a potentially important therapeutic improvement if shown to be safe and effective. Early feasibility studies of single-fraction stereotactic body radiotherapy have demonstrated encouraging results, but rigorous evaluation and follow-up are required. In this document, the basic concepts of stereotactic body radiotherapy are summarized, before focusing on stereotactic arrhythmia radioablation. We describe the effect of radioablation on cardiac tissue and its interaction with intracardiac devices, depending on the dose. The different clinical studies on ventricular tachycardia radioablation are analysed, with a focus on target identification, which is the key feature of this approach. Our document ends with the indications and requirements for practicing this type of procedure in 2020. Finally, because of the limited number of patients treated so far, we encourage multicentre registries with long-term follow-up.


Asunto(s)
Ventrículos Cardíacos/efectos de la radiación , Radiocirugia , Taquicardia Ventricular/radioterapia , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Animales , Femenino , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Radiocirugia/efectos adversos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
9.
Int J Radiat Oncol Biol Phys ; 95(2): 721-8, 2016 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-26960748

RESUMEN

PURPOSE: To analyze the relationship between dosimetric characteristics and symptoms related to trigeminal neuropathy (TN) observed after radiosurgery (RS) for vestibular schwannomas (VS); to propose guidelines to optimize planification in VS RS regarding TN preservation; and to detail the mechanism of TN impairment after VS RS. METHODS AND MATERIALS: One hundred seventy-nine patients treated between 2011 and 2013 for VS RS and without trigeminal impairment before RS were included in a retrospective study. Univariate and multivariate analyses were performed to determine predictors of TN among characteristics of the patients, the dosimetry, and the VS. RESULTS: There were 20 Koos grade 1, 99 grade 2, 57 grade 3, and 3 grade 4. Fourteen patients (7.8%) presented a transitory or permanent TN. Between the patients with and without TN after VS RS, there was no significant difference regarding dosimetry or VS volume itself. Significant differences (univariate analysis P<.05, Mann-Whitney test) were found for parameters related to the cisternal portion of the trigeminal nerve: total integrated dose, maximum dose, mean dose, volume of the Vth nerve (Volv), and volume of the Vth nerve receiving at least 11 Gy (VolVcist>11Gy), but also for maximal dose to the Vth nerve nucleus and intra-axial portion (Dose maxVax). After multivariate analysis, the best model predicting TN included VolVcist>11Gy (P=.0045), Dose maxVax (P=.0006), and Volv (P=.0058). The negative predictive value of this model was 97%. CONCLUSIONS: The parameters VolVcist>11Gy, Dose maxVax, and Volv should be checked when designing dosimetry for VS RS.


Asunto(s)
Neuroma Acústico/radioterapia , Radiocirugia/efectos adversos , Enfermedades del Nervio Trigémino/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica , Estudios Retrospectivos
10.
J Neurosurg ; 125(Suppl 1): 89-96, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27903189

RESUMEN

OBJECTIVE Grade II meningiomas, which currently account for 25% of all meningiomas, are subject to multiple recurrences throughout the course of the disease and represent a challenge for the neurosurgeon. Radiosurgery is increasingly performed for the treatment of Grade II meningiomas and is quite efficient in controlling relapses locally at the site of the lesion, but it cannot prevent margin relapses. The aim of this retrospective study was to analyze the technical parameters involved in producing marginal relapses and to optimize loco-marginal control to improve therapeutic strategy. METHODS Eighteen patients presenting 58 lesions were treated by Gamma Knife radiosurgery (GKRS) between 2010 and 2015 in Hopital de la Pitié-Salpêtrière. The median patient age was 68 years (25%-75% interval: 61-72 years), and the sex ratio (M/F) was 13:5. The median delay between surgery and first GKRS was 3 years. Patients were classified as having Grade II meningioma using World Health Organization (WHO) 2007 criteria. The tumor growth rate was computed by comparing 2 volumetric measurements before treatment. After GKRS, iterative MRI, performed every 6 months, detected a relapse if tumor volume increased by more than 20%. Patterns of relapse were defined as being local, marginal, or distal. Survival curves were estimated using the Kaplan-Meier method, and the relationship between criterion and potential risk factors was tested by the log-rank test and univariable Cox model. RESULTS The median follow-up was 36 months (range 8-57 months). During this period, 3 patients presented with a local relapse, 5 patients with a marginal relapse, and 7 patients with a distal relapse. Crude local control was 84.5%. The local control actuarial rate was 89% at 1 year and 71% at 3 years. The marginal control actuarial rate was 81% at 1 year and 74% at 2 years. The distal control actuarial rate was 100% at 1 year, 81% at 2 years, and 53% at 3 years. Median distal control was 38 months. Progression-free survival (PFS) was 71% at 1 year, 36% at 2 years, and 23% at 3 years. Median PFS was 18 months. Lesions treated with a minimum radiation dose of ≤ 12 Gy had significantly more local relapses than those treated with a dose > 12 Gy (p = 0.04) in univariate analysis. Marginal control was significantly influenced by tumor growth rate, with a lower growth rate being highly associated with improved marginal control (p = 0.002). There was a trend toward a relationship between dose and marginal control, but it was not significant (p = 0.09). PFS was significantly associated with delay between first surgery and GKRS (p = 0.03). The authors noticed few complications with no sequelae. CONCLUSIONS In order to optimize loco-marginal control, radiosurgical treatment should require a minimum dose of > 12 Gy and an extended target volume along the dural insertion. Ideally, these parameters should correspond to the aggressiveness of the lesion, based on genetic features of the tumor.


Asunto(s)
Neoplasias Meníngeas/patología , Neoplasias Meníngeas/radioterapia , Meningioma/patología , Meningioma/radioterapia , Radiocirugia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Recurrencia Local de Neoplasia/epidemiología , Estudios Retrospectivos , Resultado del Tratamiento
11.
Med Phys ; 41(6): 061708, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24877803

RESUMEN

PURPOSE: Elekta Leksell Gamma Knife(®) (LGK) is a radiotherapy beam machine whose features are not compliant with the international calibration protocols for radiotherapy. In this scope, the Laboratoire National Henri Becquerel and the Pitié-Salpêtrière Hospital decided to conceive a new LKG dose calibration method and to compare it with the currently used one. Furthermore, the accuracy of the dose delivered by the LGK machine was checked using an "end-to-end" test. This study also aims to compare doses delivered by the two latest software versions of the Gammaplan treatment planning system (TPS). METHODS: The dosimetric method chosen is the electron paramagnetic resonance (EPR) of alanine. Dose rate (calibration) verification was done without TPS using a spherical phantom. Absolute calibration was done with factors calculated by Monte Carlo simulation (MCNP-X). For "end-to-end" test, irradiations in an anthropomorphic head phantom, close to real treatment conditions, are done using the TPS in order to verify the delivered dose. RESULTS: The comparison of the currently used calibration method with the new one revealed a deviation of +0.8% between the dose rates measured by ion chamber and EPR/alanine. For simple fields configuration (less than 16 mm diameter), the "end-to-end" tests showed out average deviations of -1.7% and -0.9% between the measured dose and the calculated dose by Gammaplan v9 and v10, respectively. CONCLUSIONS: This paper shows there is a good agreement between the new calibration method and the currently used one. There is also a good agreement between the calculated and delivered doses especially for Gammaplan v10.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/métodos , Radiometría/métodos , Radiocirugia/instrumentación , Radiocirugia/métodos , Alanina , Algoritmos , Neoplasias Encefálicas/cirugía , Calibración , Simulación por Computador , Cabeza/diagnóstico por imagen , Cabeza/efectos de la radiación , Humanos , Modelos Biológicos , Método de Montecarlo , Fantasmas de Imagen , Dosificación Radioterapéutica , Programas Informáticos , Tomografía Computarizada por Rayos X , Agua
12.
Int J Radiat Oncol Biol Phys ; 89(1): 182-90, 2014 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24725701

RESUMEN

PURPOSE: In left-side breast radiation therapy (RT), doses to the left main (LM) and left anterior descending (LAD) coronary arteries are usually assessed after delineation by prior anatomic knowledge on the treatment planning computed tomography (CT) scan. In this study, dose sensitivity due to interindividual coronary topology variation was assessed, and hot spots were located. METHODS AND MATERIALS: Twenty-two detailed heart models, created from heart computed tomography angiographies, were fitted into a single representative female thorax. Two breast RT protocols were then simulated into a treatment planning system: the first protocol comprised tangential and tumoral bed beams (TGs_TB) at 50 + 16 Gy, the second protocol added internal mammary chain beams at 50 Gy to TGs_TB (TGs_TB_IMC). For the heart, the LAD, and the LM, several dose indicators were calculated: dose-volume histograms, mean dose (Dmean), minimal dose received by the most irradiated 2% of the volume (D2%), and 3-dimensional (3D) dose maps. Variations of these indicators with anatomies were studied. RESULTS: For the LM, the intermodel dispersion of Dmean and D2% was 10% and 11%, respectively, with TGs_TB and 40% and 80%, respectively, with TGs_TB_IMC. For the LAD, these dispersions were 19% (Dmean) and 49% (D2%) with TGs_TB and 35% (Dmean) and 76% (D2%) with TGs_TB_IMC. The 3D dose maps revealed that the internal mammary chain beams induced hot spots between 20 and 30 Gy on the LM and the proximal LAD for some coronary topologies. Without IMC beams, hot spots between 5 and 26 Gy are located on the middle and distal LAD. CONCLUSIONS: Coronary dose distributions with hot spot location and dose level can change significantly depending on coronary topology, as highlighted by 3D coronary dose maps. In clinical practice, coronary imaging may be required for a relevant coronary dose assessment, especially in cases of internal mammary chain irradiation.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Angiografía Coronaria/métodos , Vasos Coronarios/anatomía & histología , Imagenología Tridimensional/métodos , Arterias Mamarias/diagnóstico por imagen , Modelos Anatómicos , Planificación de la Radioterapia Asistida por Computador/métodos , Aorta/anatomía & histología , Aortografía/métodos , Neoplasias de la Mama/patología , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/efectos de la radiación , Femenino , Corazón/anatomía & histología , Corazón/diagnóstico por imagen , Humanos , Arterias Mamarias/efectos de la radiación , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Carga Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA