Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Acta Orthop ; 88(3): 341-347, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28266233

RESUMEN

Purpose - We wanted to examine the potential of the Scandinavian Sarcoma Group (SSG) Central Register, and evaluate referral and treatment practice for soft-tissue sarcomas in the extremities and trunk wall (STS) in the Nordic countries. Background - Based on incidence rates from the literature, 8,150 (7,000-9,300) cases of STS of the extremity and trunk wall should have been diagnosed in Norway, Finland, Iceland, and Sweden from 1987 through 2011. The SSG Register has 6,027 cases registered from this period, with 5,837 having complete registration of key variables. 10 centers have been reporting to the Register. The 5 centers that consistently report treat approximately 90% of the cases in their respective regions. The remaining centers have reported all the patients who were treated during certain time periods, but not for the entire 25-year period. Results - 59% of patients were referred to a sarcoma center untouched, i.e. before any attempt at open biopsy. There was an improvement from 52% during the first 5 years to 70% during the last 5 years. 50% had wide or better margins at surgery. Wide margins are now achieved less often than 20 years ago, in parallel with an increase in the use of radiotherapy. For the centers that consistently report, 97% of surviving patients are followed for more than 4 years. Metastasis-free survival (MFS) increased from 67% to 73% during the 25-year period. Interpretation - The Register is considered to be representative of extremity and trunk wall sarcoma disease in the population of Scandinavia, treated at the reporting centers. There were no clinically significant differences in treatment results at these centers.


Asunto(s)
Sarcoma/terapia , Neoplasias de los Tejidos Blandos/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Niño , Preescolar , Extremidades , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Recurrencia Local de Neoplasia/epidemiología , Derivación y Consulta/estadística & datos numéricos , Sistema de Registros , Sarcoma/diagnóstico , Sarcoma/epidemiología , Sarcoma/patología , Sarcoma/secundario , Países Escandinavos y Nórdicos/epidemiología , Neoplasias de los Tejidos Blandos/diagnóstico , Neoplasias de los Tejidos Blandos/epidemiología , Neoplasias de los Tejidos Blandos/patología , Torso
2.
Acta Odontol Scand ; 65(6): 324-30, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17934889

RESUMEN

OBJECTIVE: Ozone (O3) has been suggested as an anti-microbial treatment in dentistry, with an ozone gas delivery system introduced for the treatment of fissure and root caries. The aim of this study was to investigate the sealing capacity of the novel delivery system and its re-suction capacity during accidental displacement of the cup at different stages of ozone delivery. MATERIAL AND METHODS: Ozone leakage was studied in vitro after application on a flat metal surface and on buccal and occlusal tooth surfaces. An ozone analyzer was used to measure ozone gas concentrations adjacent to the delivering cups when adapted to the target surfaces during and after 10-20 s application cycles. The measured levels were compared with the background concentrations in the room. Measurements were performed 1) after complete ozone application cycles, 2) within the cycle before the start of the suction period, and 3) after displacements of the cup during the cycles. RESULTS: Ozone air values varied between 8 and 166 microgram/meter-3 for the flat metal surface and between 0 and 108 microgram/meter-3 for the tooth surfaces. Ozone leakage levels were 7.6 microgram/m-3 for the flat and and 7.4 microgram/meter-3 and 5.6 microgram/meter-3 for the buccal and occlusal surfaces, respectively, and 5.2 microgram/meter-3 and 9.8 microgram/meter-3 for the premolar and molar surfaces, respectively. Cycles with displacement showed significantly higher leakage levels than continuous complete cycles (p=0.03). CONCLUSIONS: Ozone application cycles with displacements showed significantly higher leakage levels than continuous complete cycles. The largest ozone delivery cups showed the highest leakage values. A change in background levels was seen with similar change in adjacent ozone levels. The overall measured ozone leakage values were low after normally functioning delivery cycles and after repeated displacements. The delivery system can be considered safe.


Asunto(s)
Contaminación del Aire Interior/análisis , Antiinfecciosos/análisis , Desinfectantes Dentales/análisis , Equipo Dental , Ozono/análisis , Diente Premolar , Sistemas de Liberación de Medicamentos , Fómites , Depuradores de Gas , Humanos , Diente Molar , Seguridad , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA