Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Diabetes Technol Ther ; 26(6): 411-419, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38215205

RESUMEN

Background: This study aimed to evaluate the accuracy of Dexcom G6 (DG6) and FreeStyle Libre-2 (FSL2) during aerobic training and high-intensity interval training (HIIT) in individuals with type 1 diabetes. Methods: Twenty-six males (mean age 29.3 ± 6.3 years and mean duration of diabetes 14.9 ± 6.1 years) participated in this study. Interstitial glucose levels were measured using DG6 and FSL2, while plasma glucose levels were measured every 10 min using YSI 2500 as the reference for glucose measurements in this study. The measurements began 20 min before the start of exercise and continued for 20 min after exercise. Seven measurements were taken for each subject and exercise. Results: Both DG6 and FSL2 devices showed significant differences compared to YSI glucose data for both aerobic and HIIT exercises. Continuous glucose monitoring (CGM) devices exhibited superior performance during HIIT than aerobic training, with DG6 showing a mean absolute relative difference of 14.03% versus 31.98%, respectively. In the comparison between the two devices, FSL2 demonstrated significantly higher effectiveness in aerobic training, yet its performance was inferior to DG6 during HIIT. According to the 40/40 criteria, both sensors performed similarly, with marks over 93% for all ranges and both exercises, and above 99% for HIIT and in the >180 mg/dL range, which is in accordance with FDA guidelines. Conclusions: The findings suggest that the accuracy of DG6 and FSL2 deteriorates during and immediately after exercise but remains acceptable for both devices during HIIT. However, accuracy is compromised with DG6 during aerobic exercise. This study is the first to compare the accuracy of two CGMs, DG6, and FSL2, during two exercise modalities, using plasma glucose YSI measurements as the gold standard for comparisons. It was registered at clinicaltrials.gov (NCT06080542).


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Ejercicio Físico , Entrenamiento de Intervalos de Alta Intensidad , Humanos , Masculino , Diabetes Mellitus Tipo 1/sangre , Entrenamiento de Intervalos de Alta Intensidad/métodos , Adulto , Glucemia/análisis , Ejercicio Físico/fisiología , Adulto Joven , Reproducibilidad de los Resultados , Monitoreo Continuo de Glucosa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA