RESUMEN
BACKGROUND: A novel implantable sensor has been designed to measure the inferior vena cava (IVC) area accurately so as to allow daily monitoring of the IVC area and collapse to predict congestion in heart failure (HF). METHODS: A prospective, multicenter, single-arm, Early Feasibility Study enrolled 15 patients with HF (irrespective of ejection fraction) and with an HF event in the previous 12 months, an elevated NT-proBNP level, and receiving ≥ 40 mg of furosemide equivalent. Primary endpoints included successful deployment without procedure-related (30 days) or sensor-related complications (3 months) and successful data transmission to a secure database (3 months). Accuracy of sensor-derived IVC area, patient adherence, NYHA classification, and KCCQ were assessed from baseline to 3 months. Patient-specific signal alterations were correlated with clinical presentation to guide interventions. RESULTS: Fifteen patients underwent implantation: 66 ± 12 years; 47% female; 27% with HFpEF, NT-ProBNP levels 2569 (median, IQR: 1674-5187, ng/L; 87% NYHA class III). All patients met the primary safety and effectiveness endpoints. Sensor-derived IVC areas showed excellent agreement with concurrent computed tomography (R2â¯=â¯0.99, mean absolute errorâ¯=â¯11.15 mm2). Median adherence to daily readings was 98% (IQR: 86%-100%) per patient-month. A significant improvement was seen in NYHA class and a nonsignificant improvement was observed in KCCQ. CONCLUSIONS: Implantation of a novel IVC sensor (FIRE1) was feasible, uncomplicated and safe. Sensor outputs aligned with clinical presentations and improvements in clinical outcomes. Future investigation to establish the IVC sensor remote management of HF is strongly warranted.
RESUMEN
BACKGROUND: Transvenous endomyocardial biopsy is an invasive procedure which is used to diagnose rejection following an orthotopic heart transplant. Endomyocardial biopsy is widely regarded as low risk with all-cause complication rates below 5% in most safety studies. Following transplant, some patients require therapeutic anticoagulation. It is unknown whether anticoagulation increases endomyocardial biopsy bleeding risk. METHODS: Records from 2061 endomyocardial biopsies performed for post-transplant rejection surveillance at our institution between November 2016 and August 2022 were reviewed. Bleeding complications were defined as vascular access-related hematoma or bleeding, procedure-related red blood cell transfusion, and new pericardial effusion. Relative risk and small sample-adjusted 95% confidence interval was calculated to investigate the association between bleeding complications and anticoagulation. RESULTS AND CONCLUSIONS: The overall risk of bleeding was 1.2% (25/2061 cases). There was a statistically significant increase in bleeding among patients on intravenous (RR 4.46, CI 1.09-18.32) but not oral anticoagulants (RR .62, CI .15-2.63) compared to patients without anticoagulant exposure. There was a trend toward increased bleeding among patients taking warfarin with INR ≥ 1.8 (RR 3.74, CI .90-15.43). Importantly, no bleeding events occurred in patients taking direct oral anticoagulants such as apixaban. Based on these results, intravenous rather than oral anticoagulation was associated with a significantly higher risk of bleeding complications following endomyocardial biopsy.
Asunto(s)
Anticoagulantes , Trasplante de Corazón , Humanos , Anticoagulantes/efectos adversos , Estudios Retrospectivos , Warfarina/efectos adversos , Biopsia , Hemorragia , Trasplante de Corazón/efectos adversosRESUMEN
BACKGROUND: Placement of an interatrial shunt device reduces pulmonary capillary wedge pressure during exercise in patients with heart failure and preserved or mildly reduced ejection fraction. We aimed to investigate whether an interatrial shunt can reduce heart failure events or improve health status in these patients. METHODS: In this randomised, international, blinded, sham-controlled trial performed at 89 health-care centres, we included patients (aged ≥40 years) with symptomatic heart failure, an ejection fraction of at least 40%, and pulmonary capillary wedge pressure during exercise of at least 25 mm Hg while exceeding right atrial pressure by at least 5 mm Hg. Patients were randomly assigned (1:1) to receive either a shunt device or sham procedure. Patients and outcome assessors were masked to randomisation. The primary endpoint was a hierarchical composite of cardiovascular death or non-fatal ischemic stroke at 12 months, rate of total heart failure events up to 24 months, and change in Kansas City Cardiomyopathy Questionnaire overall summary score at 12 months. Pre-specified subgroup analyses were conducted for the heart failure event endpoint. Analysis of the primary endpoint, all other efficacy endpoints, and safety endpoints was conducted in the modified intention-to-treat population, defined as all patients randomly allocated to receive treatment, excluding those found to be ineligible after randomisation and therefore not treated. This study is registered with ClinicalTrials.gov, NCT03088033. FINDINGS: Between May 25, 2017, and July 24, 2020, 1072 participants were enrolled, of whom 626 were randomly assigned to either the atrial shunt device (n=314) or sham procedure (n=312). There were no differences between groups in the primary composite endpoint (win ratio 1·0 [95% CI 0·8-1·2]; p=0·85) or in the individual components of the primary endpoint. The prespecified subgroups demonstrating a differential effect of atrial shunt device treatment on heart failure events were pulmonary artery systolic pressure at 20W of exercise (pinteraction=0·002 [>70 mm Hg associated with worse outcomes]), right atrial volume index (pinteraction=0·012 [≥29·7 mL/m2, worse outcomes]), and sex (pinteraction=0·02 [men, worse outcomes]). There were no differences in the composite safety endpoint between the two groups (n=116 [38%] for shunt device vs n=97 [31%] for sham procedure; p=0·11). INTERPRETATION: Placement of an atrial shunt device did not reduce the total rate of heart failure events or improve health status in the overall population of patients with heart failure and ejection fraction of greater than or equal to 40%. FUNDING: Corvia Medical.
Asunto(s)
Cateterismo Cardíaco , Insuficiencia Cardíaca , Adulto , Cateterismo Cardíaco/instrumentación , Flavinas , Atrios Cardíacos/cirugía , Insuficiencia Cardíaca/fisiopatología , Humanos , Luciferasas , Masculino , Volumen SistólicoRESUMEN
BACKGROUND: Deposition of wild-type or mutant transthyretin (TTR) amyloid fibrils in the myocardium causes TTR amyloid cardiomyopathy (ATTR-CM). Targeted therapeutics for ATTR-CM include TTR stabilizers (tafamidis and diflunisal) and oligonucleotide drugs (revusiran, patisiran, and inotersen). TTR stabilizers prevent dissociation of transthyretin tetramers. Transthyretin monomers can misfold and form amyloid fibrils. TTR stabilizers thereby limit amyloid fibrils development and deposition. Oligonucleotide drugs inhibit hepatic synthesis of transthyretin, which decreases transthyretin protein levels and thus the amyloid fibril substrate. AREAS OF UNCERTAINTY: To study the safety and efficacy of targeted therapeutics in patients with ATTR-CM, we performed a pooled analysis. A random-effects model with the Mantel-Haenszel method was used to pool the data. DATA SOURCES: A literature search was performed using PubMed, Cochrane CENTRAL, and Embase databases using the search terms "cardiac amyloidosis" AND "tafamidis" OR "patisiran" OR "inotersen" OR "revusiran" OR "diflunisal." THERAPEUTIC ADVANCES: We identified 6 studies that compared targeted therapeutics with placebo. One study was stopped prematurely because of increased mortality in the targeted therapeutics arm. Pooled analysis included 1238 patients, of which 738 patients received targeted therapeutics and 500 patients received placebo. When compared with placebo, targeted therapeutics significantly reduced all-cause mortality [OR 0.39, 95% confidence interval (CI): 0.16-0.97, P = 0.04]. Only 2 studies reported the effect on cardiovascular-related hospitalizations. There was a trend toward an improvement in global longitudinal strain (mean difference -0.69, 95% CI: -1.44 to 0.05, P = 0.07). When compared with placebo, there was no increase in serious adverse events with targeted therapeutics (OR 1.06, 95% CI: 0.78-1.44, P = 0.72). CONCLUSION: Evidence from the pooled analysis revealed targeted therapeutics improve survival and are well-tolerated. These findings suggest a potential role for targeted therapeutics in the treatment of patients with ATTR-CM.
Asunto(s)
Neuropatías Amiloides Familiares , Cardiomiopatías , Diflunisal , Humanos , Neuropatías Amiloides Familiares/tratamiento farmacológico , Prealbúmina/metabolismo , Prealbúmina/uso terapéutico , Diflunisal/farmacología , Diflunisal/uso terapéutico , Oligonucleótidos/farmacología , Oligonucleótidos/uso terapéutico , Cardiomiopatías/tratamiento farmacológicoRESUMEN
There is limited evidence comparing direct oral anticoagulants (DOACs) and warfarin in solid organ transplant (SOT) recipients. We performed a pooled analysis to study the safety and efficacy of DOACs in this patient population. We searched PubMed, Embase, and Scopus databases using the search terms "heart transplant" or "lung transplant" or "liver transplant" or "kidney transplant" or "pancreas transplant" and "direct oral anticoagulant" for literature search. Random effects model with Mantel-Haenszel method was used to pool the outcomes. Pooled analysis included 489 patients, of which 259 patients received DOACs and 230 patients received warfarin. When compared to warfarin, the use of DOACs was associated with decreased risk of composite bleed (RR .49, 95% CI .32-.76, p = .002). There were no differences in rates of major bleeding (RR .55, 95% CI .20-1.49, p = .24) or venous thromboembolism (RR .65, 95% CI .25-1.70, p = .38) between the two groups. Evidence from pooled analysis suggests that DOACs are comparable to warfarin in terms of safety in SOT recipients. Further research is warranted to conclusively determine whether DOACs are safe alternatives to warfarin for anticoagulation in SOT recipients.
Asunto(s)
Trasplante de Riñón , Tromboembolia Venosa , Administración Oral , Anticoagulantes/uso terapéutico , Hemorragia/etiología , Humanos , Tromboembolia Venosa/etiología , Tromboembolia Venosa/prevención & control , Warfarina/uso terapéuticoRESUMEN
BACKGROUND: In nonrandomized, open-label studies, a transcatheter interatrial shunt device (IASD, Corvia Medical) was associated with lower pulmonary capillary wedge pressure (PCWP), fewer symptoms, and greater quality of life and exercise capacity in patients with heart failure (HF) and midrange or preserved ejection fraction (EF ≥40%). We conducted the first randomized sham-controlled trial to evaluate the IASD in HF with EF ≥40%. METHODS: REDUCE LAP-HF I (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) was a phase 2, randomized, parallel-group, blinded multicenter trial in patients with New York Heart Association class III or ambulatory class IV HF, EF ≥40%, exercise PCWP ≥25 mm Hg, and PCWP-right atrial pressure gradient ≥5 mm Hg. Participants were randomized (1:1) to the IASD versus a sham procedure (femoral venous access with intracardiac echocardiography but no IASD placement). The participants and investigators assessing the participants during follow-up were blinded to treatment assignment. The primary effectiveness end point was exercise PCWP at 1 month. The primary safety end point was major adverse cardiac, cerebrovascular, and renal events at 1 month. PCWP during exercise was compared between treatment groups using a mixed-effects repeated measures model analysis of covariance that included data from all available stages of exercise. RESULTS: A total of 94 patients were enrolled, of whom 44 met inclusion/exclusion criteria and were randomized to the IASD (n=22) and control (n=22) groups. Mean age was 70±9 years, and 50% were female. At 1 month, the IASD resulted in a greater reduction in PCWP compared with sham control (P=0.028 accounting for all stages of exercise). Peak PCWP decreased by 3.5±6.4 mm Hg in the treatment group versus 0.5±5.0 mm Hg in the control group (P=0.14). There were no peri-procedural or 1-month major adverse cardiac, cerebrovascular, and renal events in the IASD group and 1 event (worsening renal function) in the control group (P=1.0). CONCLUSIONS: In patients with HF and EF ≥40%, IASD treatment reduces PCWP during exercise. Whether this mechanistic effect will translate into sustained improvements in symptoms and outcomes requires further evaluation. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov. Unique identifier: NCT02600234.
Asunto(s)
Función del Atrio Izquierdo , Presión Atrial , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Australia , Cateterismo Cardíaco/efectos adversos , Europa (Continente) , Tolerancia al Ejercicio , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Presión Esfenoidal Pulmonar , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento , Estados UnidosRESUMEN
Treatment of patients with heart failure with reduced ejection fraction has evolved. Recently, a fully implantable remote hemodynamic monitoring sensor in the pulmonary artery was approved in the treatment of patients at risk of heart failure readmissions. Several novel devices designed to offload the left atrium by creating a small interatrial shunt are being investigated. Cardiac imaging plays a vital role in the selection process, implantation, and monitoring of individuals with such devices. This article discusses in detail various imaging techniques and key clinical points relating to several cardiac devices used in the treatment of patients with heart failure.
Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Auxiliar/efectos adversos , Cateterismo Cardíaco/métodos , Oxigenación por Membrana Extracorpórea/efectos adversos , Insuficiencia Cardíaca/diagnóstico por imagen , HumanosAsunto(s)
Proteínas del Sistema Complemento , Trombosis , Betacoronavirus , COVID-19 , China , Infecciones por Coronavirus , Humanos , Pandemias , Neumonía Viral , SARS-CoV-2Asunto(s)
COVID-19/inmunología , Proteína Inhibidora del Complemento C1/metabolismo , Complemento C1s/antagonistas & inhibidores , SARS-CoV-2/inmunología , Trombosis/inmunología , Coagulación Sanguínea/efectos de los fármacos , Coagulación Sanguínea/inmunología , COVID-19/sangre , COVID-19/virología , Activación de Complemento/efectos de los fármacos , Activación de Complemento/inmunología , Complemento C1s/metabolismo , Inactivadores del Complemento/farmacología , Inactivadores del Complemento/uso terapéutico , Humanos , Inmunidad Innata/efectos de los fármacos , SARS-CoV-2/metabolismo , Trombosis/sangre , Trombosis/prevención & control , Tratamiento Farmacológico de COVID-19RESUMEN
The catastrophic consequences for patients in the settings of certain clinical conditions such as acute right ventricular infarction or massive pulmonary embolism with right heart failure illustrate the essential role that the right ventricle plays in sustaining life. With the development of more sophisticated diagnostic imaging technologies at the end of the last century and the dawn of this century, the importance of the right ventricle has been clearly demonstrated. The continued and evolving nature of our understanding of the right ventricle was emphasized in 2006, when the National Heart, Blood, and Lung Institute formed a working group focused on developing a better understanding of the right ventricle in both healthy and disease states. The objective of this review paper is to examine the right ventricle structure and function and describe the role of echocardiography in the evaluation of the right ventricle and right heart failure. Special focus will be on echocardiographic images and major society guidelines.
Asunto(s)
Diagnóstico por Imagen/métodos , Ecocardiografía Doppler/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Hipertensión Pulmonar/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Masculino , Tomografía de Emisión de Positrones/métodos , Guías de Práctica Clínica como Asunto , Presión Esfenoidal Pulmonar/fisiología , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/diagnóstico , Disfunción Ventricular Derecha/fisiopatologíaRESUMEN
Eosinophilic myocarditis (EM) is a rare disease associated with significant morbidity and mortality. This case series follows the clinical courses of 3 patients with EM. The use of mepolizumab, an anti-interleukin-5 monoclonal antibody, as an adjunctive treatment was associated with stabilization of cardiac function and improved long-term outcomes.
RESUMEN
BACKGROUND: The authors tested the hypothesis that physiological information from sensors within a minimally invasive, subcutaneous, insertable cardiac monitor (ICM) could be used to develop an ambulatory heart failure risk score (HFRS) to accurately identify heart failure (HF) patients, across the ejection fraction spectrum, at high risk of an impending worsening heart failure event (HFE). OBJECTIVES: The purpose of this study was to examine performance of ICM-based, multiparameter, dynamic HFRS to predict HFEs in patients with NYHA functional class II/III HF. METHODS: In 2 observational cohorts, HF patients were implanted with an ICM; subcutaneous impedance, respiratory rate, heart rate and variability, atrial fibrillation burden, ventricular rate during atrial fibrillation, and activity duration were combined into an HFRS to identify the probability of HFE within 30 days. Patients and providers were blinded to the data. HFRS sensitivity and unexplained detection rate were defined in 2 independent patient population data sets. HFEs were defined as hospitalization, observation unit, or emergency department visit with a primary diagnosis of HF, and intravenous diuretic treatment. RESULTS: First data set (development): 42 patients had 19 HFE; second data set (validation): 94 patients had 19 HFE (mean age 66 ± 11 years, 63% men, 50% with LVEF ≥40%, 80% NYHA functional class III). Using a high-risk threshold = 7.5%, development and validation data sets: sensitivity was 73.7% and 68.4%; unexplained detection rate of 1.4 and 1.5 per patient-year; median 47 and 64 days early warning before HFE. CONCLUSIONS: ICM-HFRS provides a multiparameter, integrated diagnostic method with the ability to identify when HF patients are at increased risk of heart failure events. (Reveal LINQ Evaluation of Fluid [REEF]; NCT02275923, Reveal LINQ Heart Failure [LINQ HF]; NCT02758301, Algorithm Using LINQ Sensors for Evaluation and Treatment of Heart Failure [ALLEVIATE-HF]; NCT04452149).
Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Frecuencia Cardíaca , Monitoreo Fisiológico , Factores de Riesgo , Estudios Observacionales como AsuntoRESUMEN
PURPOSE: Differentiation of the cause of left ventricular hypertrophy (LVH) is challenging in cases with co-existing hypertension. CMR offers assessment of diffuse myocardial abnormalities via T1 mapping with extracellular volume fraction (ECV) and macroscopic fibrosis via late gadolinium enhancement imaging (LGE). The goal of the study was to understand if CMR parameters can differentiate hypertensive cardiomyopathy (HC) from cardiac amyloidosis (CA) in patients with hypertension and heart failure, using endomyocardial biopsy (EMB) as the gold standard. METHODS: We retrospectively analyzed patients with hypertension, LVH, and heart failure undergoing EMB due to uncertain diagnosis. CMR parameters including cine, LGE characteristics, T1 mapping, and ECV were analyzed. RESULTS: A total of 34 patients were included (mean age 66.5 ± 10.7 years, 79.4% male). The final EMB-based diagnosis was HC (10, 29%), light chain (AL) CA (7, 21%), and transthyretin (ATTR) CA (17, 50%). There was a significant difference in subendocardial LGE (p = 0.03) and number of AHA segments with subendocardial LGE (p = 0.005). The subendocardial LGE pattern was most common in AL-CA (85.7%) and African American with HC (80%). ECV elevation (≥ 29%) was present in all patients with CA (AL-CA: 57.6 ± 5.2%, ATTR-CA: 59.1 ± 15.3%) and HC (37.3 ± 4.5%). CONCLUSIONS: Extensive subendocardial LGE pattern is not pathognomonic for CA but might also be present in African American patients with longstanding or poorly controlled HTN. The ECV elevation in HC with HF might be more significant than previously reported with an overlap of ECV values in HC and CA, particularly in younger African American patients.
RESUMEN
BACKGROUND: Diagnostic variables from insertable cardiac monitors may be useful in identifying patients at increased risk of heart failure (HF) events. High-risk alerts must be coupled with interventions to improve outcomes. We aim to assess the safety of a predefined protocolized intervention pathway activated by insertable cardiac monitor high-risk alerts. METHODS AND RESULTS: ALLEVIATE-HF (Algorithm Using LINQ Sensors for Evaluation and Treatment of Heart Failure) Phase 1 was a randomized interventional study enrolling patients with New York Heart Association class II/III and a recent HF event. A HF risk score based on insertable cardiac monitor diagnostics, including impedance, respiration rate, atrial fibrillation burden, heart rate during atrial fibrillation, heart rate variability, and activity duration, was calculated. A protocolized intervention pathway was activated when high-risk scores were detected that involved physician-prescribed nurse-implemented uptitration of diuretic for 4 days, unless safety rule-out conditions were met. Interventions could be repeated if high-risk scores persisted and did not require worsening symptoms. In total, 59 patients were randomized (mean age 68.2±11.8 years; 59.3% male); 67.8% with ejection fraction ≥50%. The mean follow-up was 11.8±8.1 months. Overall, 146 high-risk scores were recorded in 33 patients and 118 interventions occurred in 75 (51.4%) high-risk alerts that did not meet safety rule-out criteria. There were no serious adverse events and 13 adverse events related to interventions. In patients with symptoms at intervention initiation, symptoms resolved in 37 interventions (80%) and worsened in 8 (17%). In asymptomatic patients, symptoms developed in 3 interventions (7%). CONCLUSIONS: A personalized medication intervention based on insertable cardiac monitor risk score can be safely instituted in patients with HF, irrespective of symptoms. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique Identifier: NCT04452149.
Asunto(s)
Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Anciano , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Persona de Mediana Edad , Medición de Riesgo , Frecuencia Cardíaca , Factores de Riesgo , Diuréticos/uso terapéutico , Electrocardiografía Ambulatoria/instrumentación , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Anciano de 80 o más Años , Medicina de Precisión/métodos , Valor Predictivo de las PruebasRESUMEN
AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.
Asunto(s)
Seno Coronario , Estudios de Factibilidad , Atrios Cardíacos , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Femenino , Masculino , Volumen Sistólico/fisiología , Anciano , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Seno Coronario/fisiopatología , Resultado del Tratamiento , Persona de Mediana Edad , Ecocardiografía/métodos , Calidad de Vida , Cateterismo Cardíaco/métodos , Estudios Prospectivos , Función Ventricular Izquierda/fisiología , Estudios de Seguimiento , Hemodinámica/fisiologíaRESUMEN
Background: Tacrolimus toxicity in patient's status post-orthotropic heart transplantation is not commonly reported. Given its narrow therapeutic window and drug-drug interactions, it must be closely monitored by providers who are experienced in transplant management. There are no case series of patients with tacrolimus toxicity in the setting of treatment for Sars-2-CoV-19 (COVID 19) for heart-transplant recipients. We present a case of tacrolimus toxicity in the setting of concurrent ritonavir-nirmatrelvir (Paxlovid) use. Case summary: The patient was a 74-year-old male with a prior significant history of heart transplantation and on maintenance immunosuppression with tacrolimus. He contracted COVID-19 and was prescribed antiviral therapy with Paxlovid by an outside provider prior to admission. The patient complained of severe headaches, dehydration, and tremors. After eliminating acute intracranial processes with imaging, laboratory investigation revealed a severely elevated tacrolimus level with acute renal injury. The patient was taken off tacrolimus and treated conservatively with intravenous hydration. The symptoms improved, particularly the headaches. He was discharged with instructions to resume his home dosing of tacrolimus and return to clinic in 1 week with a repeat trough level. The subsequent trough level was no longer supra-therapeutic. Discussion: Tacrolimus has a potent drug-drug interaction with Paxlovid (ritonavir-nirmatrelvir) and can be supra-therapeutic. Toxicity is associated with multiple adverse effects, including but not limited to, acute renal injury, neurotoxicity, and infections due to over-immunosuppression. As Paxlovid is effective in treating Sars-2-CoV-19 in heart-transplant recipients, knowledge and understanding of drug-drug interactions is crucial in preventing and mitigating toxicity.
RESUMEN
BACKGROUND: Temporal characteristics of a multimetric risk score and its individual parameters before, during, and after a heart failure (HF) event have not been defined. OBJECTIVES: A large real-world patient cohort with implantable cardioverter-defibrillators and cardiac resynchronization therapy (CRT) defibrillators was used to define these temporal characteristics. METHODS: Deidentified health records were linked to manufacturer's device database in 17,886 patients. Multimetric risk score combined daily measures of impedance, heart rate, activity, heart rate variability, and atrial fibrillation (AF) burden, AF ventricular rate, CRT pacing, and ventricular tachycardia episodes and shocks. HF event was defined as an inpatient, emergency department, or observation unit stay with primary diagnosis of HF and intravenous diuretic agents administration. Changes in risk parameters during 60 days before, during, and after an HF event were compared in patients with no HF readmissions vs patients with HF readmission. RESULTS: A total of 1,174 patients had HF events with no HF readmission, and 282 patients had HF events with HF readmission. Diagnostic risk score was higher on all 60 days before and after a HF event in patients with HF readmission compared with patients with no readmission (P < 0.001). Change in risk score from admission to discharge was similar in patients with and without HF readmission, but the risk score fell more significantly 7 after discharge and 30 days after admission in patients without HF readmission (P < 0.001). CONCLUSIONS: Temporal characteristics of risk metrics were significantly different in patients with no HF readmissions vs patients with HF readmission; patients without HF recurrence had larger recovery of risk metrics values toward normal.
Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Hospitalización , Dispositivos de Terapia de Resincronización Cardíaca , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Fibrilación Atrial/diagnósticoRESUMEN
BACKGROUND: Heart failure (HF) is associated with both mortality and a significant decline in health status. Interatrial shunting is increasingly being investigated as a novel therapeutic option. OBJECTIVES: The ALT FLOW Early Feasibility Study was designed to evaluate the safety of the Edwards left atrial to coronary sinus APTURE Transcatheter Shunt System in patients with symptomatic HF. METHODS: A total of 18 centers enrolled patients with symptomatic HF with a pulmonary capillary wedge pressure >15 mm Hg at rest or 25 mm Hg during exercise. RESULTS: Between May 2018 and September 2022, 87 patients underwent attempted APTURE shunt implantation. Mean age was 71 years, and 53% were male. At baseline, mean left ventricular ejection fraction was 59% with 90% of the patients being in NYHA functional class III. Device success was achieved in 78 patients (90%), with no device occlusions or associated adverse events identified after implantation. The primary safety outcome occurred in only 2 patients (2.3%) at 30 days. At 6 months, health status improved: 67% of participants achieved NYHA functional class I to II status, with a 23-point improvement (P < 0.0001; 95% CI: 17-29 points) in the Kansas City Cardiomyopathy Questionnaire overall summary score. Also at 6 months, 20-W exercise pulmonary capillary wedge pressure was 7 mm Hg lower (P < 0.0001; 95% CI: -11 to -4 mm Hg) without change in right atrial pressure or other right heart function indices. CONCLUSIONS: In this single-arm experience, the APTURE Transcatheter Shunt System in patients with symptomatic HF was observed to be safe and resulted in reduction in pulmonary capillary wedge pressure and clinically meaningful improvements in HF symptoms and quality of life indices.
Asunto(s)
Fibrilación Atrial , Seno Coronario , Insuficiencia Cardíaca , Humanos , Masculino , Anciano , Femenino , Volumen Sistólico , Función Ventricular Izquierda , Seno Coronario/diagnóstico por imagen , Calidad de Vida , Cateterismo Cardíaco , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiologíaRESUMEN
Background: Beta-adrenergic antagonists or blockers (BB) are a cornerstone of cardiac therapy for multiple indications. However, BB are considered relatively contraindicated in amyloid cardiomyopathy due to poor tolerance. This intolerance is hypothesized to be due to concomitant neuropathy and significant restrictive cardiomyopathy. This study analyzes the incidence and characteristics of BB tolerance in patients with amyloid cardiomyopathy. Methods: Through a single-center retrospective chart review, patients with amyloid cardiomyopathy, confirmed by endomyocardial biopsy or technetium-99 pyrophosphate scan, were identified and clinical data was collected. Statistical methods included Chi-square test and two sample t-tests. Results: Of 135 cardiac amyloidosis patients, 27 patients (20.0%) had no BB use, 56 patients (41.5%) were current BB users, and 52 patients (38.5%) were prior BB users. The most frequent indications for BB use were heart failure, hypertension, coronary artery disease, and arrhythmia. The most common reason for stopping BB therapy was hypotension (62.8%) followed by fatigue, bradycardia, and orthostasis. Neurologic symptoms at the initial BB prescription or most recent evaluation were not significantly different between current and prior BB users. Their cardiovascular profiles were similar by ejection fraction, wall thickness, troponin I, and brain natriuretic peptide. There was no association for BB discontinuation based on amyloid subtype, sex, or race. Conclusion: The majority of patients with amyloid cardiomyopathy were prescribed BB, and over half of these patients still tolerated BB therapy. Current and prior BB users had similar profiles from a cardiovascular and neurologic perspective, with no association identified to predict BB discontinuation.
RESUMEN
Amyloidosis refers to a group of conditions where abnormal protein-or amyloid-deposits in tissues or organs, often leading to organ malfunction. Amyloidosis affects nearly any organ system, but especially the heart, kidneys, liver, peripheral nervous system, and gastrointestinal tract. Neuromuscular deficits comprise some of its ubiquitous manifestations. Amyloidosis can be quite challenging to diagnose given its clinical heterogeneity and multi-system nature. Early diagnosis with accurate genetic and serologic subtyping is key for effective management and prevention of organ decline. In this review, we highlight the value of a multidisciplinary comprehensive amyloidosis clinic. While such a model exists at numerous clinical and research centers across the globe, the lack of more widespread adoption of such a model remains a major hindrance to the timely diagnosis of amyloidosis. Such a multidisciplinary care model allows for the timely and effective diagnosis of amyloidosis, be it acquired amyloid light amyloidosis (AL), hereditary transthyretin amyloidosis (hATTR), or wild type amyloidosis (TTR-wt), especially in the current era of personalized genomic medicine. A multidisciplinary clinic optimizes the delivery of singular or combinatorial drug therapies, depending on amyloid type, fibril deposition location, and disease progression. Such an arrangement also helps advance research in the field. We present our experience at The Ohio State University, as one example out of many, to highlight the centrality of a multi-disciplinary clinic in amyloidosis care.