Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
World J Urol ; 41(11): 2881-2888, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36929407

RESUMEN

PURPOSE: To evaluate outcomes of flexible ureteroscopy for renal stones by comparing hard versus soft stones based on their attenuation on computed tomography (Hounsfield Units-HU). METHODS: Patients were divided into two groups according to the type of laser employed [Holmium:YAG (HL) or Thulium fiber laser (TFL)]. Residual fragments (RF) were defined as > 2 mm. Multivariable logistic regression analysis was performed to evaluate factors associated with RF and RF needing further intervention. RESULTS: 4208 patients from 20 centers were included. In whole series, age, recurrent stones, stone size, lower pole stones (LPS), and multiple stones were predictors of RF at multivariable analysis and LPS and stone size with RF requiring further treatment. HU and TFL were associated with lesser RF and RF requiring an additional treatment. In HU < 1000 stones, recurrent stones, stone size, and LPS were predictors of RF at multivariable analysis, whereas TFL was less likely associated with RF. Recurrent stones, stone size, and multiple stones were predictors of RF requiring further treatment, while LPS and TFL were associated with lesser RF requiring further treatment. In HU ≥ 1000 stones, age, stone size, multiple stones, and LPS were predictors of RF at multivariable analysis, while TFL was less likely associated with RF. Stone size and LPS were predictors of RF requiring further treatment, whereas TFL was associated with RF requiring further treatment. CONCLUSION: Stone size, LPS, and use of HL are predictors of RF after RIRS for intrarenal stones regardless of stone density. HU should be considered an important parameter in predicting SFR.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Humanos , Litotripsia por Láser/métodos , Tulio , Holmio , Ureteroscopía/métodos , Resultado del Tratamiento , Lipopolisacáridos , Cálculos Renales/diagnóstico por imagen , Cálculos Renales/cirugía , Rayos Láser , Sistema de Registros , Láseres de Estado Sólido/uso terapéutico
2.
World J Urol ; 41(5): 1407-1413, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36930255

RESUMEN

PURPOSE: To evaluate the perioperative outcomes of retrograde intra-renal surgery (RIRS) for lower pole stones (LPS) and factors affecting stone-free rate (SFR). METHODS: Data from 20 centers were retrospectively reviewed. Inclusion criteria were adult patients, normal renal anatomy, and LPS. Exclusion criteria were bilateral surgery, concomitant surgery for ureteral stones. SFR was defined as a single residual fragment (RF) ≤ 2 mm and evaluated 3-months after surgery. A multivariable logistic regression analysis was performed to assess factors associated with RF. Statistical significance was set at p value < 0.05. RESULTS: 2946 patients were included. Mean age and stone size were 49.9 years 10.19 mm, with multiple LPS in 61.1% of cases. Total operation and laser time were 63.89 ± 37.65 and 17.34 ± 18.39 min, respectively. Mean hospital stay was 3.55 days. Hematuria requiring blood transfusion and fever/urinary infections requiring prolonged antibiotics occurred in 6.1% and 169 5.7% of cases, while sepsis with intensive-care admission in 1.1% of patients. On multivariate analysis, Multiple stones (OR 1.380), stone size (OR 1.865), and reusable ureteroscopes (OR 1.414) were significantly associated with RF, while Thulium fiber laser (TFL) (OR 0.341) and pre-stenting (OR 0.750) were less likely associated with RF. CONCLUSIONS: RIRS showed safety and efficacy for LPS with a mean diameter of 10 mm. This procedure can achieve a satisfactory SFR in pre-stented patients with a single and smaller stone, particularly with TFL use.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Adulto , Humanos , Cálculos Renales/cirugía , Estudios Retrospectivos , Lipopolisacáridos , Litotricia/métodos , Cálculos Ureterales/cirugía , Resultado del Tratamiento
3.
World J Urol ; 41(2): 567-574, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36536170

RESUMEN

PURPOSE: To collect a multicentric database on behalf of TOWER research group to assess practice patterns and outcomes of retrograde intrarenal surgery (RIRS) for kidney stones. METHODS: Inclusion criteria: age ≥ 18 years, normal renal/calyceal system anatomy, calculi of any size, number, and position. STUDY PERIOD: January 2018 and August 2021. Stone-free status: absence of fragments > 2 mm, assessed post procedure according to the local protocol (KUB X-Ray and/or ultrasound or non-contrast CT scan). RESULTS: Twenty centers from fifteen countries enrolled 6669 patients. There were 4407 (66.2%) men. Mean age was 49.3 ± 15.59 years. Pain was the most frequent symptom indication for intervention (62.6%). 679 (10.2%) patients underwent RIRS for an incidental finding of stones. 2732 (41.0%) patients had multiple stones. Mean stone size was 10.04 ± 6.84 mm. A reusable flexible ureteroscope was used in 4803 (72.0%) procedures. A sheath-less RIRS was performed in 454 (6.8%) cases. Holmium:YAG laser was used in 4878 (73.1%) cases. A combination of dusting and fragmentation was the most common lithotripsy mode performed (64.3%). Mean operation time was 62.40 ± 17.76 min. 119 (1.8%) patients had an intraoperative injury of the ureter due to UAS insertion. Mean postoperative stay was 3.62 ± 3.47 days. At least one postoperative complication occurred in 535 (8.0%) patients. Sepsis requiring intensive care admission occurred in 84 (1.3%) patients. Residual fragments were detected in 1445 (21.7%) patients. Among the latter, 744 (51.5%) patients required a further intervention. CONCLUSION: Our database contributes real-world data to support to a better understanding of modern RIRS practice and outcomes.


Asunto(s)
Cálculos Renales , Litotricia , Uréter , Masculino , Humanos , Adulto , Persona de Mediana Edad , Adolescente , Femenino , Ureteroscopía/métodos , Cálculos Renales/cirugía , Sistema de Registros , Resultado del Tratamiento
4.
Ther Adv Urol ; 15: 17562872231158072, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36923302

RESUMEN

Introduction: With several single-use ureteroscopes now available, our aim was to analyze and compare data obtained globally from high-volume centers using both disposable and reusable flexible ureteroscopes and see if indeed in real-world practice either scope has a distinct advantage. Methods: Retrospective analysis was performed on the FLEXOR registry, which was created as a TOWER group (Team of Worldwide Endourological Researchers, research wing of the Endourological Society) endeavor. Patients who underwent retrograde intrarenal surgery (RIRS) for renal stones from January 2018 to August 2021 were enrolled from 20 centers globally. A total of 6663 patients whose data were available for analysis were divided into Group 1 (Reusable scopes, 4808 patients) versus Group 2 (Disposable scopes, 1855 patients). Results: The age and gender distribution were similar in both groups. The mean stone size was 11.8 mm and 9.6 mm in Groups 2 and 1, respectively (p < 0.001). Group 2 had more patients with >2 cm stones, lower pole stones and of higher Hounsfield unit. Thulium fiber laser (TFL) was used more in Group 2 (p < 0.001). Patients in Group 2 had a slightly higher stone-free rate (SFR) (78.22%) and a lower number of residual fragments (RFs) compared with Group 1 (p < 0.001). The need for further treatments for RF and overall complications was comparable between groups. On multivariate analysis, overall complications were more likely to occur in elderly patients, larger stone size, lower pole stones, and were also more when using disposable scopes with longer operative time. RFs were significantly higher (p < 0.001) for lower pole, larger, harder, multiple stones and in elderly. Conclusion: Our real-world practice observations suggest that urologists choose disposable scopes for bigger, lower pole, and harder stones, and it does indeed help in improving the single-stage SFR if used correctly, with the appropriate lasers and lasing techniques in expert hands.

5.
Cancers (Basel) ; 15(23)2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-38067266

RESUMEN

BACKGROUND: We aimed to analyze the influence of near-infrared fluorescence (NIRF) using indocyanine green (ICG) with standard robot-assisted partial nephrectomy (RAPN) in patients with a kidney tumor (KT). METHODS: We performed a literature search on 12 September 2023 through PubMed, EMBASE, and Scopus. The analysis included observational studies that examined the perioperative and long-term outcomes of patients with a KT who underwent RAPN with NIRF. RESULTS: Overall, eight prospective studies, involving 535 patients, were eligible for this meta-analysis, with 212 participants in the ICG group and 323 in the No ICG group. For warm ischemia time, the ICG group showed a lower duration (weighted Mean difference (WMD) = -2.05, 95% confidence interval (CI) = -3.30--0.80, p = 0.011). The postoperative eGFR also favored the ICG group (WMD = 7.67, 95% CI = 2.88-12.46, p = 0.002). No difference emerged for the other perioperative outcomes between the two groups. In terms of oncological radicality, the positive surgical margins and tumor recurrence rates were similar among the two groups. CONCLUSIONS: Our meta-analysis showed that NIRF with ICG during RAPN yields a favorable impact on functional outcomes, whereas it exerts no such influence on oncological aspects. Therefore, NIRF should be adopted when preserving nephron function is a paramount concern.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA