Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Vet Diagn Invest ; 19(5): 552-7, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17823402

RESUMEN

Management of prion diseases in livestock would benefit greatly from availability of a validated blood test. A promising immunocapillary electrophoresis technique (also known as capillary electrophoresis fluoroimmunoassay) to detect abnormal prion protein in blood from live sheep is evaluated here. Capillary electrophoresis fluoroimmunoassay was applied to analysis of extracted blood from scrapie-exposed sheep (n = 87; 347 samples) at various stages of incubation, and to control sheep (n = 194; 489 samples). Overall, test values for the control and test populations were not significantly different, and a similar proportion of control (7%) and test (10%) sheep were classified as positive. Over 2-3 month intervals from birth until clinical disease, test specificity and sensitivity ranged from 66.7% to 100% and 0% to 66.7%, respectively, indicating poor diagnostic performance at all stages of pathogenesis. In routine application, in its present form, the capillary electrophoresis fluoroimmunoassay procedure proved to be insufficiently robust for use as a blood test for scrapie diagnosis.


Asunto(s)
Electroforesis Capilar/veterinaria , Fluoroinmunoensayo/veterinaria , Proteínas PrPSc/sangre , Scrapie/sangre , Scrapie/diagnóstico , Envejecimiento , Animales , Scrapie/patología , Ovinos
3.
J Vasc Surg ; 35(2): 286-91, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11854726

RESUMEN

PURPOSE: The purpose of this study was the assessment of the safety, efficacy, and hospital charges of bedside duplex ultrasound-directed inferior vena cava (IVC) filter placement. METHODS: All duplex ultrasound-directed IVC filters that were placed from August 8, 1995, to December 31, 2000, are reviewed. Chart review combined with mailed questionnaires and telephone follow-up examinations were used to collect demographic and outcome data. RESULTS: Three hundred twenty-five patients underwent evaluation, and 284 underwent duplex ultrasound-directed IVC filter placement. Two hundred three (71%) were male patients, and 81 (29%) were female patients. Poor IVC visualization, IVC thrombosis, and unsuitable anatomy prevented duplex-directed filter placement in 41 patients (12%). Indication for filter placement included venous prophylaxis in the absence of thromboembolism in 235 patients (83%), contraindication to anticoagulation therapy in 34 patients (12%), prophylaxis with therapeutic anticoagulation therapy in the presence of thromboembolism in 7 patients (2%), and complication of anticoagulation therapy in 8 patients (3%). There were no procedure-related deaths or septic complications. Technical complications occurred in 12 patients (4%). Filter misplacement occurred in 6 patients (2%), access thrombosis in 1 (<1%), migration in 1 (<1%), bleeding in 1 (<1%), and IVC occlusion in 3 (1%). Pulmonary emboli after IVC filter placement occurred in one patient with a misplaced filter. Average hospital charges related to duplex ultrasound-directed filter placement were $2388 less than fluoroscopic placement charges in the year 2000. CONCLUSION: Our experience indicates that duplex ultrasound-directed IVC filter placement is safe, cost-effective, and convenient for patients who need IVC filter placement.


Asunto(s)
Ultrasonografía Doppler Dúplex/instrumentación , Filtros de Vena Cava , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Prótesis Vascular/economía , Seguridad de Equipos , Femenino , Vena Femoral/diagnóstico por imagen , Vena Femoral/patología , Estudios de Seguimiento , Costos de la Atención en Salud , Humanos , Pierna/irrigación sanguínea , Pierna/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/mortalidad , Embolia Pulmonar/prevención & control , Análisis de Supervivencia , Tennessee/epidemiología , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex/economía , Filtros de Vena Cava/economía , Filtros de Vena Cava/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA