Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(21)2022 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-36366221

RESUMEN

Microbial mediator biosensors for surface water toxicity determination make it possible to carry out an early assessment of the environmental object's quality without time-consuming standard procedures based on standard test-organisms, and provide broad opportunities for receptor element modifying depending on the required operational parameters analyzer. Four microorganisms with broad substrate specificity and nine electron acceptors were used to form a receptor system for toxicity assessment. Ferrocene was the most effective mediator according to its high rate constant of interaction with the microorganisms (0.33 ± 0.01 dm3/(g × s) for yeast Saccharomyces cerevisiae). Biosensors were tested on samples containing four heavy metal ions (Cu2+, Zn2+, Pb2+, Cd2+), two phenols (phenol and p-nitrophenol), and three natural water samples. The «ferrocene- Escherichia coli¼ and «ferrocene-Paracoccus yeei, E. coli association¼ systems showed good operational stability with a relative standard deviation of 6.9 and 7.3% (14 measurements) and a reproducibility of 7 and 5.2% using copper (II) ions as a reference toxicant. Biosensor analysis with these systems was shown to highly correlate with the results of the standard method using Chlorella algae as a test object. Developed biosensors allow for a valuation of the polluted natural water's impact on the ecosystem via an assessment of the influence on bacteria and yeast in the receptor system. The systems could be used in toxicological monitoring of natural waters.


Asunto(s)
Técnicas Biosensibles , Chlorella , Metales Pesados , Contaminantes Químicos del Agua , Metalocenos , Agua/análisis , Escherichia coli , Saccharomyces cerevisiae , Reproducibilidad de los Resultados , Ecosistema , Técnicas Biosensibles/métodos , Metales Pesados/toxicidad , Metales Pesados/análisis , Contaminantes Químicos del Agua/análisis
2.
Sensors (Basel) ; 22(16)2022 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-36015810

RESUMEN

The possibility of the developing a biochemical oxygen demand (BOD) biosensor based on electroactive biofilms of activated sludge grown on the surface of a graphite-paste electrode modified with carbon nanotubes was studied. A complex of microscopic methods controlled biofilm formation: optical microscopy with phase contrast, scanning electron microscopy, and laser confocal microscopy. The features of charge transfer in the obtained electroactive biofilms were studied using the methods of cyclic voltammetry and electrochemical impedance spectroscopy. The rate constant of the interaction of microorganisms with the extracellular electron carrier (0.79 ± 0.03 dm3(g s)-1) and the heterogeneous rate constant of electron transfer (0.34 ± 0.02 cm s-1) were determined using the cyclic voltammetry method. These results revealed that the modification of the carbon nanotubes' (CNT) electrode surface makes it possible to create electroactive biofilms. An analysis of the metrological and analytical characteristics of the created biosensors showed that the lower limit of the biosensor based on an electroactive biofilm of activated sludge is 0.41 mgO2/dm3, which makes it possible to analyze almost any water sample. Analysis of 12 surface water samples showed a high correlation (R2 = 0.99) with the results of the standard method for determining biochemical oxygen demand.


Asunto(s)
Técnicas Biosensibles , Nanotubos de Carbono , Biopelículas , Técnicas Biosensibles/métodos , Electrodos , Oxígeno/análisis , Aguas del Alcantarillado , Agua/análisis
3.
Polymers (Basel) ; 16(10)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38794624

RESUMEN

This work proposes an approach to the formation of receptor elements for the rapid diagnosis of the state of surface waters according to two indicators: the biochemical oxygen demand (BOD) index and toxicity. Associations among microorganisms based on the bacteria P. yeei and yeast S. cerevisiae, as well as associations of the yeasts O. polymorpha and B. adeninivorans, were formed to evaluate these indicators, respectively. The use of nanocomposite electrically conductive materials based on carbon nanotubes, biocompatible natural polymers-chitosan and bovine serum albumin cross-linked with ferrocenecarboxaldehyde, neutral red, safranin, and phenosafranin-has made it possible to expand the analytical capabilities of receptor systems. Redox polymers were studied by IR spectroscopy and Raman spectroscopy, the contents of electroactive components were determined by atomic absorption spectroscopy, and electrochemical properties were studied by electrochemical impedance and cyclic voltammetry methods. Based on the proposed kinetic approach to modeling individual stages of bioelectrochemical processes, the chitosan-neutral red/CNT composite was chosen to immobilize the yeast association between O. polymorpha (ks = 370 ± 20 L/g × s) and B. adeninivorans (320 ± 30 L/g × s), and a bovine serum albumin (BSA)-neutral composite was chosen to immobilize the association between the yeast S. cerevisiae (ks = 130 ± 10 L/g × s) and the bacteria P. yeei red/CNT (170 ± 30 L/g × s). After optimizing the composition of the receptor systems, it was shown that the use of nanocomposite materials together with associations among microorganisms makes it possible to determine BOD with high sensitivity (with a lower limit of 0.6 mg/dm3) and detect the presence of a wide range of toxicants of both organic and inorganic origin. Both receptor elements were tested on water samples, showing a high correlation between the results of biosensor analysis of BOD and toxicity and the results of standard analytical methods. The results obtained show broad prospects for creating sensitive and portable bioelectrochemical sensors for the early warning of environmentally hazardous situations based on associations among microorganisms and nanocomposite materials.

4.
Biosensors (Basel) ; 14(5)2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38785713

RESUMEN

Biofilms based on bacteria Pseudomonas veronii (Ps. veronii) and Escherichia coli (E. coli) and yeast Saccharomyces cerevisiae (S. cerevisiae) were used for novel biosensor creation for rapid biochemical oxygen demand (BOD) monitoring. Based on the electrochemical measurement results, it was shown that the endogenous mediator in the matrix of E. coli and Ps. veronii biofilms and ferrocene form a two-mediator system that improves electron transport in the system. Biofilms based on Ps. veronii and E. coli had a high biotechnological potential for BOD assessment; bioreceptors based on such biofilms had high sensitivity (the lower limits of detectable BOD5 concentrations were 0.61 (Ps. veronii) and 0.87 (E. coli) mg/dm3) and high efficiency of analysis (a measurement time 5-10 min). The maximum biosensor response based on bacterial biofilms has been observed in the pH range of 6.6-7.2. The greatest protective effect was found for biofilms based on E. coli, which has high long-term stability (151 days for Ps. veronii and 163 days for E. coli). The results of the BOD5 analysis of water samples obtained using the developed biosensors had a high correlation with the results of the standard 5-day method (R2 = 0.9820, number of tested samples is 10 for Ps. veronii, and R2 = 0.9862, number of tested samples is 10 for E. coli). Thus, biosensors based on Ps. veronii biofilms and E. coli biofilms could be a novel analytical system to give early warnings of pollution.


Asunto(s)
Biopelículas , Técnicas Biosensibles , Electrodos , Escherichia coli , Grafito , Saccharomyces cerevisiae , Pseudomonas , Análisis de la Demanda Biológica de Oxígeno
5.
Biosensors (Basel) ; 14(6)2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38920606

RESUMEN

Microbial biofilms present one of the most widespread forms of life on Earth. The formation of microbial communities on various surfaces presents a major challenge in a variety of fields, including medicine, the food industry, shipping, etc. At the same time, this process can also be used for the benefit of humans-in bioremediation, wastewater treatment, and various biotechnological processes. The main direction of using electroactive microbial biofilms is their incorporation into the composition of biosensor and biofuel cells This review examines the fundamental knowledge acquired about the structure and formation of biofilms, the properties they have when used in bioelectrochemical devices, and the characteristics of the formation of these structures on different surfaces. Special attention is given to the potential of applying the latest advances in genetic engineering in order to improve the performance of microbial biofilm-based devices and to regulate the processes that take place within them. Finally, we highlight possible ways of dealing with the drawbacks of using biofilms in the creation of highly efficient biosensors and biofuel cells.


Asunto(s)
Fuentes de Energía Bioeléctrica , Biopelículas , Técnicas Biosensibles
6.
Polymers (Basel) ; 15(18)2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37765637

RESUMEN

Conductive polymers and their composites are excellent materials for coupling biological materials and electrodes in bioelectrochemical systems. It is assumed that their relevance and introduction to the field of bioelectrochemical devices will only grow due to their tunable conductivity, easy modification, and biocompatibility. This review analyzes the main trends and trends in the development of the methodology for the application of conductive polymers and their use in biosensors and biofuel elements, as well as describes their future prospects. Approaches to the synthesis of such materials and the peculiarities of obtaining their nanocomposites are presented. Special emphasis is placed on the features of the interfaces of such materials with biological objects.

7.
3 Biotech ; 13(4): 112, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36883049

RESUMEN

The possibility of using a composite material based on bovine serum albumin (BSA) covalently bonded with ferrocenecarboxaldehyde and containing carbon nanotubes (CNT) for the immobilization of Blastobotrys adeninivorans BKM Y-2677 (B. adeninivorans) yeast is discussed. The optimal ratio of ferrocenecarboxaldehyde to BSA for the redox-active polymer synthesis is 1:2, since the heterogeneous electron transfer constant is 0.45 ± 0.01 s-1. When carbon nanotubes (CNTs) are added to this polymer, the heterogeneous electron transfer constant increases: at a CNT specific density of 2.5 µg/mm2, it reaches a maximum value of 0.55 ± 0.01 s-1. The addition of CNTs into the conducting system leads to increasing of the rate constant of interaction redox species with B. adeninivorans yeast by an order: the rate constant of interaction between B. adeninivorans yeast and electroactive particles in a redox-active polymer is 0.056 ± 0.005 dm3/g × s and in a composite material based on CNTs is 0.51 ± 0.02 dm3/g × s. The yeast specific density at the electrode of 0.1 mg/mm2 and electrolyte pH of 6.2 was chosen as the working value for the receptor system operation. Immobilized in a composite material, yeast oxidizes a wider range of substrates compared with a similar receptor element based on the ferrocene mediator. The biosensors formed on the basis of hybrid polymers have a high sensitivity with a lower limit of determined concentrations of 1.5 mg/dm3 with an assay time of 5 min and a high correlation (R = 0.9945) with the results of the standard method for determining biochemical oxygen demand (BOD) in nine real surface water samples of the Tula region.

8.
Polymers (Basel) ; 15(16)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37631392

RESUMEN

Electropolymerized thionine was used as a redox-active polymer to create a two-mediated microbial biosensor for determining biochemical oxygen demand (BOD). The electrochemical characteristics of the conducting system were studied by cyclic voltammetry and electrochemical impedance spectroscopy. It has been shown that the most promising in terms of the rate of interaction with the yeast B. adeninivorans is the system based on poly(thionine), single-walled carbon nanotubes (SWCNT), and neutral red (kint = 0.071 dm3/(g·s)). The biosensor based on this system is characterized by high sensitivity (the lower limit of determined BOD concentrations is 0.4 mgO2/dm3). Sample analysis by means of the developed analytical system showed that the results of the standard dilution method and those using the biosensor differed insignificantly. Thus, for the first time, the fundamental possibility of effectively using nanocomposite materials based on SWCNT and the redox-active polymer poly(thionine) as one of the components of two-mediator systems for electron transfer from yeast microorganisms to the electrode has been shown. It opens up prospects for creating stable and highly sensitive electrochemical systems based on eukaryotes.

9.
Polymers (Basel) ; 14(24)2022 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-36559732

RESUMEN

The possibility of using the microorganisms Pseudomonas sp. 7p-81, Pseudomonas putida BS394(pBS216), Rhodococcus erythropolis s67, Rhodococcus pyridinivorans 5Ap, Rhodococcus erythropolis X5, Rhodococcus pyridinivorans F5 and Pseudomonas veronii DSM 11331T as the basis of a biosensor for the phenol index to assess water environments was studied. The adaptation of microorganisms to phenol during growth was carried out to increase the selectivity of the analytical system. The most promising microorganisms for biosensor formation were the bacteria P. putida BS394(pBS216). Cells were immobilized in redox-active polymers based on bovine serum albumin modified by ferrocenecarboxaldehyde and based on a composite with a carbon nanotube to increase sensitivity. The rate constants of the interaction of the redox-active polymer and the composite based on it with the biomaterial were 193.8 and 502.8 dm3/(g·s) respectively. For the biosensor created using hydrogel bovine serum albumin-ferrocene-carbon nanotubes, the lower limit of the determined phenol concentrations was 1 × 10-3 mg/dm3, the sensitivity coefficient was (5.8 ± 0.2)∙10-3 µA·dm3/mg, Michaelis constant KM = 230 mg/dm3, the maximum rate of the enzymatic reaction Rmax = 217 µA and the long-term stability of the bioanalyzer was 11 days. As a result of approbation, it was found that the urban water phenol content differed insignificantly, measured by creating a biosensor and using the standard photometric method.

10.
3 Biotech ; 11(5): 222, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33968567

RESUMEN

This work proposes a method of forming a microorganism-mediator(s) receptor system, in which the rates of separate stages of mediator bioelectrocatalysis are used as the basis for the development of biosensors for the biochemical oxygen demand (BOD) rapid assay. In the presence of a ferrocene mediator, the yeast Blastobotrys adeninivorans was shown to enable oxidation of a larger range of substrates as compared with other investigated microorganisms-bacteria Escherichia coli and yeast Ogataea polymorpha. The rate constants of the interaction of the yeast B. adeninivorans with nine compounds, electron transfer mediators, were determined; the best mediator for these microorganisms was found to be neutral red (k int = 0.681 ± 0.009 dm3/g s). Neutral red possesses a high rate of interaction with the ferrocene mediator (14,200 ± 100 dm3/mol s) shown earlier to be the most promising acceptor of electrons at a carbon paste electrode (0.4 ± 0.1 cm/s). These features enabled the formation of a two-mediator ferrocene-neutral red system to be used in a biosensor. A two-mediator-based biosensor had a higher sensitivity (the lower limit of detected BOD concentrations, 0.16 mg/dm3) than that of a one-mediator system based on neutral red and ferrocene. Analysis of ten samples from surface water reservoirs showed the combination of ferrocene, neutral red and the yeast B. adeninivorans to enable the data that highly correlated (R = 0.9693) with those of the standard method.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA