Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Insights Imaging ; 11(1): 15, 2020 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-32030539

RESUMEN

OBJECTIVE: As gonad shielding is currently under debate, this study evaluates the practice, from its introduction in about 1905 until today. METHODS: The literature was searched for developments in shielding and insights into the effects of ionising radiation on gonads. Based on own pre-1927 dose reconstructions, reported doses after 1927, a 2015-report from the European Union and recent own measurements, the effects of technological evolution and optimisation on radiation dose and hereditary risk were assessed. RESULTS: In the 1900s, gonad shielding was first applied to prevent male sterility, but was discontinued when instrumental developments led to reduced radiation doses. In the 1950s, concerns about hereditary risks intensified and gonad shielding was recommended again, becoming routine worldwide. Imaging-chain improvements over time were considerable: in 2018, the absorbed dose was 0.5% of its 1905 value for the testes and 2% for the ovaries, our optimised effective dose a factor five lower than the value corresponding to the current EU diagnostic reference level, and the reduction in detriment-adjusted risk by shielding less than 1 × 10-6 for women and 5 × 10-6 for men. CONCLUSIONS: Assessment of pelvic doses revealed a large reduction in radiation risks facilitated by technological developments. Optimisation likewise contributed, but unfortunately, its potential was never adequately exploited. Today, using a modern and optimised X-ray system, gonad shielding can be safely discontinued for women. For men, there might be a marginal benefit, but potential negative side-effects may well dominate. Discontinuation of gonad shielding seems therefore justifiable.

2.
Insights Imaging ; 10(1): 39, 2019 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-30923937

RESUMEN

OBJECTIVES: To derive conversions of antiquated exposure data into modern equivalents and to apply these in the assessment of the skin dose of pelvic radiographs since 1896. METHODS: The literature 1896-2018 was searched for implicit and explicit dose information. The early implicit dose data contained now obsolete descriptions of radiation quality and quantity for long since disappeared X-ray systems of limited efficiency. Converting the old information into modern specifications was achieved using contemporary data and computer simulations. Final dose calculations were done with modern software. Explicit radiation doses of later date reported in old quantities and units were adapted according to current recommendations. RESULTS: For the period before 1927 conversion algorithms for spark gap data and penetrometer hardnesses to high voltage could be derived. Electrical and X-ray efficiencies of several old röntgen systems were determined. Together they allowed reconstruction of 53 doses. After 1927 doses were generally explicitly specified; 114 were retrieved. Although an enormous spread was observed, the average skin dose was reduced by a factor of about 400. CONCLUSIONS: Antiquated exposure data were successfully used for dose reconstruction. Extreme dose variability was a constant. Efforts to cut down doses were effective as skin doses went down from sub-erythema values to about one milligray.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA