Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ann Vasc Surg ; 28(6): 1384-90, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24517989

RESUMEN

BACKGROUND: Endovascular aortic repair (EVAR) is being used with increasing frequency for the treatment of ruptured abdominal aortic aneurysms (rAAAs), although conflicting results have been reported concerning perioperative mortality. The aim of our study was to evaluate potential difference in mortality rates between EVAR and open surgical repair (OSR) and identify independent risk factors for in-hospital mortality in rAAAs. This study also aimed to evaluate the Glasgow Aneurysm Score (GAS) in predicting in-hospital mortality. A time-trend analysis of EVAR for ruptured AAAs was also performed. METHODS: Prospectively collected data from 7 public hospitals in Greece concerning rAAA repairs between January 2006 and April 2012 were analyzed. Primary outcome was in-hospital mortality. Multivariate logistic regression analysis was used to identify independent risk factors. The receiver-operator characteristic curve was used to determine the value of the GAS in predicting in-hospital death. Time-trend analysis, depicting annual changes (%), concerning EVAR for ruptured AAAs was also conducted. RESULTS: A total of 418 patients (92.3% men, mean age = 74.3 ± 8.8) with rAAAs were recorded during the study period. Among them, 113 patients (27%) underwent EVAR. Overall in-hospital mortality was 45.2%, whereas in-hospital mortality after EVAR and OSR was 20.4% and 54.3%, respectively (P < 0.001). Multivariate analysis evidenced that hemodynamic instability (P < 0.001), OSR (P < 0.001), age ≥80 years (P < 0.001), coronary artery disease (P < 0.001), and renal insufficiency (P = 0.02) independently increased in-hospital mortality. Area under the curve of GAS was 0.80 (95% confidence interval [CI] = 0.75-0.85, P < 0.001) for OSR and 0.64 (95% CI = 0.51-0.77, P = 0.04) for EVAR. Annual increase of proportion (%) of EVAR for rupture was 5% (P = 0.004). CONCLUSIONS: EVAR is being used with increasing frequency for the treatment of rAAAs and it appears to be associated with lower in-hospital mortality compared with OSR, after adjustment for hemodynamic instability and known atherosclerotic risk factors. Preoperative predictors of in-hospital mortality such as GAS should be probably modified in these patients.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/mortalidad , Mortalidad Hospitalaria , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Rotura de la Aorta/diagnóstico , Rotura de la Aorta/mortalidad , Rotura de la Aorta/fisiopatología , Área Bajo la Curva , Implantación de Prótesis Vascular/efectos adversos , Distribución de Chi-Cuadrado , Bases de Datos Factuales , Técnicas de Apoyo para la Decisión , Procedimientos Endovasculares/efectos adversos , Femenino , Grecia , Hemodinámica , Hospitales Públicos , Humanos , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Curva ROC , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
J Vasc Surg ; 56(3): 594-600, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22579136

RESUMEN

INTRODUCTION: Suprarenal endograft fixation is routinely used in the endovascular repair of abdominal aortic aneurysms (EVAR) to enhance proximal endograft attachment but can be associated with an adverse outcome in renal function. This prospective study assessed the effect of suprarenal fixation on serum creatinine concentration and estimated glomerular filtration rate (eGFR), calculated by the Modified Diet in Renal Disease equation, 12 months after elective EVAR. METHODS: Patients undergoing elective EVAR were divided into suprarenal vs infrarenal fixation groups matched for age, sex, smoking, and aneurysm diameter. Serum creatinine and eGFR were measured at baseline, 6, and 12 months. RESULTS: Included were 92 patients (two women) with a mean age of 71 ± 7 years, with 46 in each group. No device-related complications were noted. Serum creatinine did not differ significantly between groups at 6 (P = .24) or 12 (P = .08) months but significantly increased in the suprarenal group at 12 months (1.08 ± 0.36 to 1.16 ± 0.36 mg/dL; P < .001) vs baseline. The eGFR (mL/min/1.73 m(2)) did not differ significantly at baseline between the suprarenal (85 ± 27) and infrarenal (80 ± 28; P = .33) groups or at 6 months (88 ± 29 vs 77 ± 24, respectively; P = .07). At 12 months, the suprarenal group had a lower eGFR (73 ± 23) than the infrarenal group (84 ± 26; P = .027). The eGFR at 12 months showed a significant decrease in the suprarenal (80 ± 28 to 73 ± 23; P < .001) but not in the infrarenal group (85 ± 27 to 84 ± 26; P = .48). The drop in eGFR differed significantly at 12 months in the infrarenal vs the suprarenal (0.82 vs -6.94; P < .001) group. No patient progressed to end-stage renal disease or disclosed a drop in eGFR > 30%. CONCLUSIONS: In contrast to previous studies, this study suggests that suprarenal endograft fixation in elective EVAR is associated with a drop in eGFR at 12 months.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Riñón/fisiopatología , Anciano , Biomarcadores/sangre , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Estudios de Casos y Controles , Creatinina/sangre , Procedimientos Quirúrgicos Electivos , Procedimientos Endovasculares/instrumentación , Inglaterra , Femenino , Tasa de Filtración Glomerular , Humanos , Riñón/metabolismo , Enfermedades Renales/sangre , Enfermedades Renales/etiología , Enfermedades Renales/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
3.
J Vasc Surg ; 55(6): 1726-33, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22322119

RESUMEN

OBJECTIVE: This study evaluated the contribution of Aptus EndoStaples (Aptus Endosystems, Sunnyvale, Calif) in the proximal fixation of eight endografts used in the endovascular repair of abdominal aortic aneurysms (EVAR). METHODS: Nine human cadaveric aortas were exposed, left in situ, and transected to serve as fixation zones. The Zenith (Cook, Bloomington, Ind), Anaconda (Vascutek, Inchinnan, Scotland, UK), Endurant (Medtronic, Minneapolis, Minn), Excluder (W. L. Gore and Associates, Flagstaff, Ariz), Aptus (Aptus Endosystems), Aorfix (Lombard Medical, Didcot, UK), Talent (Medtronic), and AneuRx (Medtronic) stent grafts were proximally deployed and caudal displacement force (DF) was applied via a force gauge, recording the DF required to dislocate each device ≥20 mm from the infrarenal neck. Measurements were repeated after four and six EndoStaples were applied at the proximal fixation zone, as well as after a Dacron graft was sutured at the proximal neck in standard fashion. Finally, a silicone tube was used as a control fixation zone to test the DF of grafts with EndoStaples in a material that exceeded the integrity of a typical human cadaveric aorta and provided a consistent substrate to examine the differential effect of variable degrees of EndoStaple implantation using zero, two, four, and six EndoStaples. RESULTS: In the cadaveric model, the mean DF required to dislocate the endografts without the application of EndoStaples was 19.73 ± 12.52 N; this increased to 49.72 ± 12.53 N (P < .0001) when four EndoStaples where applied and to 79.77 ± 28.04 N when six EndoStaples were applied (P = .003). The DF necessary to separate the conventionally hand-sutured Dacron graft from the aorta was 56 N. In the silicone tube model, the Aptus endograft without EndoStaples withstood 3.2 N of DF. The DF increased to 39 ± 3 N when two EndoStaples were added, to 71 ± 6 N when four were added, and to 98 ± 5 N when six were added. In eight of the 13 cadaver experiments conducted with four and six EndoStaples, the displacement occurred as a result of complete aortic transection proximal to the fixation site, indicating that aortic tissue integrity was the limiting factor in these experiments. CONCLUSIONS: The fixation of eight different endografts was increased by a mean of 30 N with four Aptus EndoStaples and by a mean of 57 N with six EndoStaples in this model. Endostaples can increase endograft fixation to levels equivalent or superior to that of a hand-sewn anastomosis. The application of six EndoStaples results in aortic tissue failure above the fixation zone, demonstrating fixation strength that exceeds inherent aortic integrity in these cadavers.


Asunto(s)
Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Stents , Técnicas de Sutura/instrumentación , Suturas , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/métodos , Cadáver , Diseño de Equipo , Falla de Equipo , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico
4.
Ann Vasc Surg ; 26(3): 421.e1-5, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22285352

RESUMEN

BACKGROUND: To present an unusual case of blunt aortic injury in a 30-year-old male patient with an aberrant right subclavian artery. METHODS AND RESULTS: Driven by the complicated and challenging nature of the case, we decided to treat the patient by a combined approach-right subclavian artery transposition and endograft implantation at the isthmus level. During the 24-month follow-up (clinical examination, angiogram, computed tomographic scan), we registered no complaints; normal perfusion of the right arm; and adequate sealing of the aortic tear. CONCLUSIONS: We believe that the hybrid management of such trauma is a feasible, effective, and less-invasive option.


Asunto(s)
Aneurisma/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Anomalías Cardiovasculares/cirugía , Trastornos de Deglución/cirugía , Procedimientos Endovasculares , Lesiones del Sistema Vascular/complicaciones , Lesiones del Sistema Vascular/cirugía , Heridas no Penetrantes/cirugía , Adulto , Aneurisma/complicaciones , Aneurisma/diagnóstico por imagen , Angiografía de Substracción Digital , Rotura de la Aorta/complicaciones , Rotura de la Aorta/diagnóstico por imagen , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Anomalías Cardiovasculares/complicaciones , Anomalías Cardiovasculares/diagnóstico por imagen , Trastornos de Deglución/complicaciones , Trastornos de Deglución/diagnóstico por imagen , Procedimientos Endovasculares/instrumentación , Humanos , Masculino , Diseño de Prótesis , Stents , Arteria Subclavia/anomalías , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/diagnóstico por imagen
5.
J Vasc Surg ; 53(5): 1237-41, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21247729

RESUMEN

BACKGROUND: The optimal management of the patients requiring cardiac surgery with concomitant severe carotid disease remains a controversy. The traditional approach involves staged or combined carotid endarterectomy and cardiac surgery. This study evaluated the feasibility and safety of angioplasty and stenting for the treatment of carotid stenoses concomitantly to cardiac operations to reduce the risk of perioperative stroke. METHODS: All patients scheduled for cardiac surgery were screened preoperatively by color duplex ultrasonography for carotid disease. Carotid stenoses ≥60% in symptomatic patients and ≥70% in asymptomatic patients were treated using carotid artery stenting (CAS) under local anesthesia immediately before the open heart surgery. Cerebral protection devices were used in all cases. Patients did not receive aspirin or clopidogrel before the procedure. In a prospective, nonrandomized study, we analyzed 90 consecutive patients requiring cardiac surgery with concomitant severe carotid artery disease who underwent one stage CAS and cardiac surgery. RESULTS: Despite the high baseline risk profile, our results were encouraging. Carotid stenting was successful in all patients. No neurologic complications occurred during the carotid stenting procedures. The 30-day death/stroke rate was 2.2% (one death, one contralateral stroke). No myocardial infarction occurred. The carotid restenosis rate was zero during the intermediate-term follow-up. CONCLUSIONS: In our experience, CAS followed immediately by cardiac surgery is safe and represents a reasonable option for selected patients presenting with severe carotid and coronary disease.


Asunto(s)
Angioplastia/instrumentación , Estenosis Carotídea/terapia , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Stents , Anciano , Anciano de 80 o más Años , Angioplastia/efectos adversos , Angioplastia/mortalidad , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/mortalidad , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Grecia , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/prevención & control , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/prevención & control , Selección de Paciente , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler en Color
6.
J Vasc Surg ; 54(2): 522-5, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21377825

RESUMEN

We are presenting a case of giant internal carotid artery aneurysm (ICAA) managed by a new exposure technique. Following double mandibular osteotomy, the exposure of the entire aneurysm was achieved by mandible mobilization. The aneurysm repair was performed by resection and graft interposition. Mandible bone reconstruction was succeeded via mini plate osteosynthesis. No adverse events were noticed during the 24-month follow-up period. The surgical ICAA management is necessary to prevent severe complications. In cases of aneurysm extension to the skull base, double mandibular osteotomy is a safe technique that facilitates aneurysm exposure and control.


Asunto(s)
Aneurisma/cirugía , Implantación de Prótesis Vascular , Enfermedades de las Arterias Carótidas/cirugía , Arteria Carótida Interna/cirugía , Endarterectomía Carotidea , Mandíbula/cirugía , Osteotomía , Adulto , Aneurisma/diagnóstico por imagen , Angiografía de Substracción Digital , Placas Óseas , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Femenino , Humanos , Osteotomía/instrumentación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
7.
J Endovasc Ther ; 18(2): 250-4, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21521067

RESUMEN

PURPOSE: To report a case in which a persistent high-flow type II endoleak after endovascular aneurysm repair (EVAR) of a leaking abdominal aortic aneurysm (AAA) complicated by an aortocaval fistula was repaired with a stent-graft in the inferior vena cava (IVC). CASE REPORT: A 76-year-old man underwent emergent EVAR with an aortomonoiliac device to exclude a leaking 9-cm AAA. The 30-day computed tomography (CT) scan showed 2-mm sac expansion and a type II endoleak arising from a lumbar artery; the outflow vessel was the inferior vena cava (IVC) via a fistula that was not depicted on the non-contrast preoperative CT or the intraoperative angiogram. No intervention was deemed necessary at the time. Six months after EVAR, the AAA had not expanded further, but the fistula between the sac and the IVC was larger in diameter. A tubular stent-graft was implanted in the IVC to seal the defect. No complications have been noted up to 36 months after the IVC stent-graft procedure. CONCLUSION: Aortocaval fistulae should be excluded in the case of persistent type II endoleaks after EVAR for ruptured AAAs. IVC endografting is a minimally invasive alternative to treat such a complication, with promising midterm results in this patient.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Endofuga/cirugía , Procedimientos Endovasculares/instrumentación , Stents , Fístula Vascular/cirugía , Vena Cava Inferior/cirugía , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/etiología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Reoperación , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Vena Cava Inferior/diagnóstico por imagen
8.
J Endovasc Ther ; 18(5): 697-715, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21992642

RESUMEN

Isolated common iliac artery aneurysms (CIAAs) are relatively rare; they typically progress asymptomatically and are revealed incidentally, usually after they have acquired significant dimensions. Traditional open reconstruction is associated with high morbidity and mortality rates. Rupture is a common initial manifestation. Endovascular repair has been proposed as a minimally invasive alternative, associated with lower morbidity and mortality rates, even in patients at high surgical risk; some specialists have recently proposed endoluminal repair as the first-choice procedure in suitable anatomies. However, only a few sporadic attempts have been made to define the "suitable" anatomy for endovascular repair. This article proposes a classification of isolated CIAAs and provides endovascular specialists with a guide to deciding which type of repair is feasible and efficacious according to the anatomical configuration of the aneurysm.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma Ilíaco/clasificación , Aneurisma Ilíaco/cirugía , Terminología como Asunto , Implantación de Prótesis Vascular/efectos adversos , Técnicas de Apoyo para la Decisión , Procedimientos Endovasculares/efectos adversos , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Selección de Paciente , Radiografía , Medición de Riesgo , Factores de Riesgo
9.
J Vasc Surg ; 50(1): 8-14, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19563949

RESUMEN

PURPOSE: This study evaluated the feasibility, efficacy, and durability of a specific aortomonoiliac endograft for the treatment of abdominal aortic aneurysm (AAA) during a midterm follow-up. METHODS: From January 2002 until November 2008, 106 patients (6 women; mean age, 73.37 +/- 7.39 years) were treated for an AAA using an EndoFit aortomonoiliac graft (LeMaitre Vascular, Burlington, Mass). All procedures were elective. RESULTS: Mean follow-up was 34.9 months (SD, 20.08; range, 2-81 months). Long-term data (follow-up >60 months) were available for nine patients, none of which reported any vascular or procedure related complications. Three of the 106 patients (2.83%) died during early follow-up (<30 days); eight died during late follow-up (7.54%). Endograft infection developed in two patients (1.88%), and an aortoduodenal fistula developed in two (1.88%). Also observed were 15 type II (14.15%) and three type I (2.83%) endoleaks. Femorofemoral bypass thrombosis was detected in two patients (1.88%). CONCLUSION: In this retrospective analysis, the aortomonoiliac configuration for elective AAA repair was proven to be safe and efficacious. Midterm and long-term follow-up results in this series compare well with previously reported results for AAA endografting using both bifurcated and aortomonoiliac endoprostheses.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Arteria Ilíaca/cirugía , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
10.
Perfusion ; 24(4): 257-62, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19755466

RESUMEN

BACKGROUND: Carotid artery stenosis (CAS) is a well-known risk factor for perioperative stroke in cardiac surgery. It is unclear whether preoperative carotid screening should be applied to all patients. Carotid intervention concomitantly with cardiac operations is also controversial. Our objective was to identify the prevalence of significant CAS and its related risk factors by applying a protocol of preoperative carotid screening to all patients undergoing cardiac surgery. METHODS: We studied 307 patients who were primarily screened preoperatively by duplex Doppler ultrasonography. Catheter carotid angiography or transcranial Doppler was performed on equivocal cases. Univariate and multivariate analyses were applied across selected parameters to identify risk factors for significant CAS (> 70%). The prevalence of CAS and perioperative stroke rates were determined. RESULTS: Twenty-two patients with severe and 18 with moderate carotid stenosis were identified. Further radiological evaluation with catheter carotid angiography and transcranial Doppler confirmed the presence of significant CAS in 20 patients who underwent carotid stenting or endarterectomy before the open heart surgery. The cardiac surgeon was free to modify the surgical technique according to the preoperative assessment. No patient had major stroke perioperatively, while two minor strokes with complete neurologic recovery have been documented. The history of stroke and the presence of bruit on clinical examination were the only significant predictors of severe carotid disease. CONCLUSION: Careful clinical examination together with detailed previous history taking can identify the majority of patients with CAS. Further data are required for the construction of a scientifically valid policy as a guideline.


Asunto(s)
Estenosis Carotídea/diagnóstico , Estenosis Carotídea/cirugía , Tamizaje Masivo , Periodo Preoperatorio , Anciano , Angiografía , Estenosis Carotídea/epidemiología , Puente de Arteria Coronaria/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Guías de Práctica Clínica como Asunto , Prevalencia , Pronóstico , Factores de Riesgo , Stents , Accidente Cerebrovascular/etiología , Ultrasonografía Doppler Transcraneal
11.
Curr Vasc Pharmacol ; 6(4): 240-9, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18855712

RESUMEN

Endovascular (EVAR) abdominal aortic aneurysm (AAA) repair has been established as a successful procedure in the short term and may constitute a viable long-term alternative to open repair (OR). The procedure has been associated with lower operative and mid-term morbidity and mortality compared to OR, but long-term results remain largely controversial. EVAR has also been associated with a significant risk of implant and procedure-related complications, such as graft thrombosis and cardiovascular events, necessitating interventional and pharmaceutical management. Medical management of patients undergoing EVAR is required for several different reasons. Patients with an AAA have an increased risk of cardiovascular death, necessitating treatment to reduce the overall risk for cardiovascular events. Treatment is in-line with the medical management of coronary artery disease including anti-platelet therapy and statins. Anti-platelet therapy is also mandatory to prevent complications such as graft-limb thrombosis and peripheral arterial disease (PAD), which is common in patients with an AAA. Especially in patients with PAD, aspirin, clopidogrel and statins remain the mainstay of medical management. Unfortunately, there is a lack of prospective randomised trials concerning the medical management of patients that have undergone abdominal aortic endo-grafting. We review the current literature on the medical treatment of patients undergoing EVAR, focusing on peri-operative management, anti-platelet agents and statins.


Asunto(s)
Aneurisma de la Aorta Abdominal/tratamiento farmacológico , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Fármacos Cardiovasculares/uso terapéutico , Enfermedades Cardiovasculares/prevención & control , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/mortalidad , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Terapia Combinada , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Cuidados Posoperatorios , Cuidados Preoperatorios , Resultado del Tratamiento
12.
J Extra Corpor Technol ; 40(1): 52-6, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18389665

RESUMEN

The endovascular repair (EVAR) of abdominal aortic aneurysms (AAAs) usually involves the surgical exposure and catheterization of the femoral arteries. Several inguinal surgical wound-related complications have been reported postoperatively. The aim of this report was to evaluate the safety and efficacy of intraoperative application of autologous platelet-rich plasma (PRP) for the prevention of wound-related complications in AAA EVAR. The authors conducted a patient- and assessor-blinded controlled trial involving 100 subjects undergoing EVAR of an AAA. PRP was produced using an autologous platelet separator and was applied, without prior thrombin activation, in 50 patients eligible for inclusion. The results were compared with a control group of 50 patients who underwent AAA EVAR within the same time period. The primary outcome was the difference in postoperative hospital stay. Secondary outcomes included subjective assessment of wound healing and wound-related complications. Age, sex, and other comorbidities related to wound healing were not significantly different between cases and controls. One patient treated with PRP developed a unilateral wound infection with lymphorrhea, and two patients developed a bi-lateral superficial infection. Twelve patients within the control group developed a wound-related complication. The postoperative hospitalization was significantly lower in the PRP group. The overall surgical wound-related complications rate was also significantly lower in the PRP group. Application of non-thrombin-activated PRP seems to prevent major postoperative wound-related complications (p = .026) and shorten postoperative hospital stay duration after femoral artery exposure and catheterization for AAA EVAR (mean, 4.48 +/- 0.48 vs. 6.14 +/- 0.39 days).


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Plaquetas , Transfusión de Sangre Autóloga , Plasma Rico en Plaquetas , Complicaciones Posoperatorias/prevención & control , Anciano , Femenino , Humanos , Masculino , Cuidados Posoperatorios , Estudios Prospectivos , Factores de Tiempo , Cicatrización de Heridas
13.
Med Princ Pract ; 17(4): 276-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18523393

RESUMEN

OBJECTIVE: The aim of our study was to demonstrate our experience regarding the surgical treatment of complications after foreign body ingestion. SUBJECT AND METHODS: From 1997 to 2005, we treated 16 adult patients (mean age 44.8 years, range 21-77), who presented with complications after foreign body ingestion. RESULTS: The complications treated were perforation-peritonitis: n = 7 (44%), intra-abdominal abscess formation: n = 5 (31%), upper gastrointestinal bleeding: n = 3 (19%) and inflammatory mass formation: n = 1 (6%) patient. The diagnosis was made intra-operatively in 13 (81.3%) of the cases. The commonest anatomical position of the perforation was the large bowel, in 7 (43%) of the cases. Bony food parts were the commonest foreign bodies accidentally swallowed, in 9 (56%) patients. The median hospital stay was 7 days (2-18), while no death occurred in the postoperative period among the patients of the study. The postoperative morbidity rate was 22.2%. CONCLUSIONS: The most common complication after foreign body ingestion was the perforation of the gastrointestinal tract. The risk of perforation was higher when sharp foreign bodies were ingested. The pre-operative diagnosis was difficult, and it was usually achieved intra-operatively.


Asunto(s)
Cuerpos Extraños/cirugía , Tracto Gastrointestinal/lesiones , Perforación Intestinal/cirugía , Adulto , Anciano , Femenino , Cuerpos Extraños/complicaciones , Tracto Gastrointestinal/cirugía , Humanos , Perforación Intestinal/etiología , Tiempo de Internación , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
14.
J Vasc Interv Radiol ; 18(3): 337-42, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17377178

RESUMEN

PURPOSE: To evaluate the efficacy of carotid artery stent placement with embolic protection. MATERIALS AND METHODS: During a 2-year period (May 2003 to April 2005), 232 patients underwent carotid artery stent placement with the Acculink RX stent-graft and an embolic protection device. There were 150 men (mean age,70 years; age range, 58-85 years) and 82 women (mean age, 76 years; age range, 56-82 years). One hundred sixty-five patients were symptomatic and 67 were asymptomatic. All patients were at high risk for carotid endarterectomy. RESULTS: The procedure was technically successful in 231 patients. The procedure was stopped in one patient due to asystole. In three patients, a cervical approach was necessary owing to aortic arch anatomy. During the procedure,11 patients (4.74%) experienced bradycardia and two developed a major stroke (0.86%). The mean follow-up was 30 months (range, 12-36 months). Four patients died. No stent occlusion was observed. During the late follow-up period(>30 days), two patients (0.86%) had minor strokes, three (1.29%) had nonfatal transient ischemic attacks, and seven(3.01%) had myocardial infarctions. CONCLUSION: Carotid artery stent placement with cerebral protection by using the specific devices compares favorably to previously reported surgical results.


Asunto(s)
Prótesis Vascular/estadística & datos numéricos , Enfermedades de las Arterias Carótidas/epidemiología , Enfermedades de las Arterias Carótidas/terapia , Embolización Terapéutica/instrumentación , Embolización Terapéutica/estadística & datos numéricos , Stents , Anciano , Anciano de 80 o más Años , Femenino , Grecia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Resultado del Tratamiento
15.
Int J Gastrointest Cancer ; 35(2): 143-5, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15879629

RESUMEN

We report a case of malignant fibrous histiocytoma (MFH) metastatic to the spine. A 41-yr-old male was admitted to our hospital for radiation treatment of MFH of the spine. He began to show signs suggestive of partial small bowel obstruction. Computed tomography demonstrated jejuno-jejunal intussusception. The patient was taken to the operating room, where the diagnosis was confirmed. Partial jejunal resection was performed. The lead point of the intussusception was histologically diagnosed to be a high-grade malignant fibrous histiocytoma. We believe that the spinal lesion was the metastatic lesion and that metastasis occurred via the vessels of Adamciewicz. To our knowledge this is the first case thus reported.


Asunto(s)
Histiocitoma Fibroso Benigno/secundario , Intususcepción/etiología , Neoplasias del Yeyuno/patología , Neoplasias de la Columna Vertebral/secundario , Adulto , Histiocitoma Fibroso Benigno/complicaciones , Humanos , Intususcepción/diagnóstico por imagen , Neoplasias del Yeyuno/complicaciones , Masculino , Tomografía Computarizada por Rayos X
16.
Vasc Endovascular Surg ; 48(7-8): 476-81, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25480667

RESUMEN

A total of 22 patients with ruptured abdominal aortic aneurysms (rAAAs) after previous endovascular aortic repair (EVAR; rAAAevar) were presented to 7 referral hospitals in Greece, between January 2006 and April 2012. Type Ia endoleak and endograft migration were identified in 72.7% and 50%, respectively. Compliance to follow-up protocol prior to rupture was 31.8%. In-hospital mortality was 36.4% (9.1% for those treated with secondary EVAR and 63.6% for those treated with open surgical repair, P = .02). An increase in the proportion of patients with rAAAevar among the total number of patients with rAAAs from 1.3% in 2007 to 18.2% in 2012 (P for trend = .04) was recorded, corresponding to an annual increase of 2.8% (b = 2.84, P = .04). Rupture after EVAR seemed to be a clinical entity encountered with increasing frequency over the past years. Type I endoleak and endograft migration were most frequently observed, whereas compliance to follow-up was low.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/etiología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/diagnóstico , Rotura de la Aorta/mortalidad , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Endofuga/etiología , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Migración de Cuerpo Extraño/etiología , Grecia , Mortalidad Hospitalaria , Humanos , Masculino , Cooperación del Paciente , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
ANZ J Surg ; 82(7-8): 510-7, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22548726

RESUMEN

Despite significant progress in the management of hepatocellular carcinoma (HCC), patients with large HCC (defined as >10 cm) continue to present a significant challenge. The goal of this paper is to review the existing literature regarding large HCC, with emphasis on identifying the issues and challenges involved in approaching these tumours surgically. A computerized search was made of the Medline database from January 1992 to December 2010. The MESH heading 'large' or 'huge' in combination with the keyword 'hepatocellular carcinoma' was used. After excluding further studies that identified 'large' HCC as less than 10 cm and/or sequential publications with overlapping patient populations, the search produced a study population of 22 non-duplicated papers, reporting on a total of 5223 patients with HCC tumours >10 cm. Regarding resection for large HCC, the overall 5-year survival in these studies ranged from 25% to 45%, with few outliers on both sides, whereas in most studies, the 5-year disease-free survival ranged between 15% and 35%, with the only exception being studies with patients with single lesions and no cirrhosis showing disease-free survival of 41% and 56%, respectively. Risk factors identified included vascular invasion, cirrhosis, high level of alpha-fetoprotein and the presence of multiple lesions. Finally, liver transplantation, although an attractive concept, did not appear to offer a survival benefit in any of the studies. In conclusion, identifying the risk factors that affect the outcome in patients undergoing surgery for large HCC is critical. The reason is that surgical resection can have excellent outcomes in carefully selected patients.


Asunto(s)
Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Hepatectomía , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Carga Tumoral , Humanos , Factores de Riesgo
18.
Vasc Endovascular Surg ; 46(3): 223-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22492108

RESUMEN

AIM: The aim of this study was to compare midterm mortality between anemic and nonanemic patients undergoing endovascular repair of abdominal aortic aneurysm and to assess a correlation with markers of inflammation. METHODS: Anemia was defined as hemoglobin <13 (men) and <12 g/dL (women). The impact of anemia and inflammatory markers on mortality was assessed using Kaplan-Meier curves and Cox regression. RESULTS: A total of 224 patients (12 females [5.36%]; age: 69.73 ± 8.72 years) were included; 102 (45.53%) were anemic. Median follow-up was 17 months (interquartile range: 7-25 months). Nine patients died (1.79%; 8 anemic vs 1 nonanemic). Survival was lower for patients with anemia (log-rank, P = .01). White blood cell count and C-reactive protein (CRP) differed significantly (P < .001 and P = .01). Anemia and CRP were associated with decreased survival (Cox regression, P = .01, hazard ratio [HR]: 0.35, 95% confidence interval: 0.14-0.84 and P = .002, HR: 1.18, 95% CI: 1.06-1.31). CONCLUSION: Patients with anemia had decreased survival over the midterm; inflammatory markers were higher among this group.


Asunto(s)
Anemia/mortalidad , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/mortalidad , Anciano , Anemia/sangre , Aneurisma de la Aorta Abdominal/sangre , Aneurisma de la Aorta Abdominal/mortalidad , Biomarcadores/sangre , Implantación de Prótesis Vascular/efectos adversos , Proteína C-Reactiva/metabolismo , Comorbilidad , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Mediadores de Inflamación/sangre , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Reino Unido/epidemiología , Regulación hacia Arriba
19.
Angiology ; 62(1): 18-32, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20566578

RESUMEN

BACKGROUND: Abdominal aortic aneurysm (AAA) is a complex disease with a largely unknown pathophysiological background and a strong genetic component. Various studies have tried to link specific genetic variants with AAA. METHODS: Systematic review of the literature (1947-2009). RESULTS: A total of 249 studies were identified, 89 of which were eventually deemed relevant to this review. Genetic variants (polymorphisms) in a wide variety of genes, most of which encode proteolytic enzymes and inflammatory molecules, have been associated with AAA development and progression. CONCLUSION: The genetic basis of AAA remains unknown, and most results from ''candidate-gene'' association studies are contradictory. Further analyses in appropriately powered studies in large, phenotypically well-characterized populations, including genome-wide association studies, are necessary to elucidate the exact genetic contribution to the pathophysiology of AAA.


Asunto(s)
Aneurisma de la Aorta Abdominal/genética , Antígenos HLA/genética , Humanos , Interleucinas/genética , Metaloproteinasas de la Matriz/genética , Peptidil-Dipeptidasa A/genética , Inhibidores Tisulares de Metaloproteinasas/genética
20.
Cardiovasc Intervent Radiol ; 32(1): 150-4, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18443856

RESUMEN

We describe the clinical course of a 5-year-old girl with severe arterial hypertension that was uncontrollable with antihypertensive medication. Renal angiography revealed bilateral renal artery stenoses. Because percutaneous transluminal renal angioplasty (PTRA) failed to dilate the stenotic lesions, a renal artery bypass grafting in both renal arteries was performed. The patient remained normotensive for 7 months, and after that the arterial pressure increased again. Digital subtraction angiography demonstrated stenosis at the peripheral and central anastomosis of the vein graft that was used for revascularization of the left kidney. PTRA was decided on and successful patency was achieved. The patient has now been normotensive for a period of 5 years.


Asunto(s)
Hipertensión/complicaciones , Obstrucción de la Arteria Renal/cirugía , Angiografía de Substracción Digital , Angioplastia de Balón , Preescolar , Femenino , Humanos , Hipertensión/tratamiento farmacológico , Pruebas de Función Renal , Arteria Renal/diagnóstico por imagen , Arteria Renal/cirugía , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/etiología , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA