Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Opt Lett ; 48(2): 383-386, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36638463

RESUMEN

We demonstrate strontium (Sr) atomic vapor cells having a total external volume of 0.63 cm3 that can operate above 300 °C for times exceeding 380 h. The cells are fabricated using micromachined silicon frames anodically bonded to glass windows that have a 20-nm thick protective layer of Al2O3 deposited on the interior surfaces. The presence of Sr vapor in the cell is confirmed through laser absorption spectroscopy for the 1S0 → 1P1 transition in Sr at 461 nm. Measurements of sub-Doppler linewidths indicated negligible (<3 MHz) broadening of this transition from residual background gas collisions. This compact and manufacturable, high-temperature atomic vapor cell can enable narrow-line optical frequency references based on strontium and other alkaline earth species.

2.
Opt Lett ; 46(18): 4702-4705, 2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34525086

RESUMEN

We describe a high-performance, compact optical frequency standard based on a microfabricated Rb vapor cell and a low-noise, external cavity diode laser operating on the Rb two-photon transition at 778 nm. The optical standard achieves an instability of 1.8×10-13τ-1/2 for times less than 100 s and a flicker noise floor of 1×10-14 out to 6000 s. At long integration times, the instability is limited by variations in optical probe power and the ac Stark shift. The retrace was measured to 5.7×10-13 after 30 h of dormancy. Such a simple, yet high-performance optical standard could be suitable as an accurate realization of the meter or, if coupled with an optical frequency comb, as a compact atomic clock comparable to a hydrogen maser.

3.
Opt Express ; 28(23): 34516-34529, 2020 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-33182919

RESUMEN

Point source atom interferometry (PSI) uses the velocity distribution in a cold atom cloud to simultaneously measure one axis of acceleration and two axes of rotation from the spatial distribution of interferometer phase in an expanded cloud of atoms. Previously, the interferometer phase has been found from the phase, orientation, and period of the resulting spatial atomic interference fringe images. For practical applications in inertial sensing and precision measurement, it is important to be able to measure a wide range of system rotation rates, corresponding to interferograms with far less than one full interference fringe to very many fringes. Interferogram analysis techniques based on image processing used previously for PSI are challenging to implement for low rotation rates that generate less than one full interference fringe across the cloud. We introduce a new experimental method that is closely related to optical phase-shifting interferometry that is effective in extracting rotation values from signals consisting of fractional fringes as well as many fringes without prior knowledge of the rotation rate. The method finds the interferometer phase for each pixel in the image from four interferograms, each with a controlled Raman laser phase shift, to reconstruct the underlying atomic interferometer phase map without image processing.

4.
Opt Express ; 28(17): 24708-24720, 2020 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-32907005

RESUMEN

Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10-12/τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.

5.
IEEE Sens J ; 19(22)2019.
Artículo en Inglés | MEDLINE | ID: mdl-32116472

RESUMEN

Advances in sensing technology raise the possibility of creating neural interfaces that can more effectively restore or repair neural function and reveal fundamental properties of neural information processing. To realize the potential of these bioelectronic devices, it is necessary to understand the capabilities of emerging technologies and identify the best strategies to translate these technologies into products and therapies that will improve the lives of patients with neurological and other disorders. Here we discuss emerging technologies for sensing brain activity, anticipated challenges for translation, and perspectives for how to best transition these technologies from academic research labs to useful products for neuroscience researchers and human patients.

6.
Opt Express ; 26(3): 3696-3701, 2018 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-29401896

RESUMEN

We report a demonstration of vapor-phase Rubidium (Rb) density stabilization in a vapor cell using a solid-state electrochemical Rb source device. Clear Rb density stabilization is observed. Further demonstrations show that the temperature coefficient for Rb density can be reduced more than 100 times when locked and the device's power consumption is less than 10 mW. Preliminary investigation of the locking dynamic range shows that the Rb density is well stabilized when the initial density is five times higher (33 × 109 /cm3) than the set point density (6 × 109 /cm3). Active stabilization with this device is of high interest for portable cold-atom microsystems where large ambient temperature working ranges and low power consumption are required.

7.
Opt Express ; 25(7): 7849-7858, 2017 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-28380903

RESUMEN

A multichannel imaging system is presented, consisting of 25 microfabricated optically-pumped magnetometers. The sensor probes have a footprint of less than 1 cm2 and a sensitive volume of 1.5 mm × 1.5 mm × 1.5 mm and connect to a control unit through optical fibers of length 5 m. Operating at very low ambient magnetic fields, the sensor array has an average magnetic sensitivity of 24 fT/Hz1/2, with a standard deviation of 5 fT/Hz1/2 when the noise of each sensor is averaged between 10 and 50 Hz. Operating in Earth's magnetic field, the magnetometers have a field sensitivity around 5 pT/Hz1/2. The vacuum-packaged sensor heads are optically heated and consume on average 76 ± 7 mW of power each. The heating power is provided by an array of eight diode lasers. Magnetic field imaging of small probe coils was obtained with the sensor array and fits to the expected field pattern agree well with the measured data.

8.
Opt Express ; 24(13): 14513-24, 2016 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-27410604

RESUMEN

We frequency stabilize the output of a miniature stimulated Brillouin scattering (SBS) laser to rubidium atoms in a microfabricated cell to realize a laser system with frequency stability at the 10-11 level over seven decades in averaging time. In addition, our system has the advantages of robustness, low cost and the potential for integration that would lead to still further miniaturization. The SBS laser operating at 1560 nm exhibits a spectral linewidth of 820 Hz, but its frequency drifts over a few MHz on the 1 hour timescale. By locking the second harmonic of the SBS laser to the Rb reference, we reduce this drift by a factor of 103 to the level of a few kHz over the course of an hour. For our combined SBS and Rb laser system, we measure a frequency noise of 4 × 104 Hz2/Hz at 10 Hz offset frequency which rapidly rolls off to a level of 0.2 Hz2/Hz at 100 kHz offset. The corresponding Allan deviation is ≤2 × 10-11 for averaging times spanning 10-4 to 103 s. By optically dividing the signal of the laser down to microwave frequencies, we generate an RF signal at 2 GHz with phase noise at the level of -76 dBc/Hz and -140 dBc/Hz at offset frequencies of 10 Hz and 10 kHz, respectively.

9.
Opt Lett ; 41(12): 2775-8, 2016 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-27304286

RESUMEN

Laser spectroscopy of atoms confined in vapor cells can be strongly affected by the presence of background gases. A significant source of vacuum contamination is the permeation of gases such as helium (He) through the walls of the cell. Aluminosilicate glass (ASG) is a material with a helium permeation rate that is many orders of magnitude lower than borosilicate glass, which is commonly used for cell fabrication. We have identified a suitable source of ASG that is fabricated in wafer form and can be anodically bonded to silicon. We have fabricated chip-scale alkali vapor cells using this glass for the windows and we have measured the helium permeation rate using the pressure shift of the hyperfine clock transition. We demonstrate micro fabricated cells with He permeation rates at least three orders of magnitude lower than that of cells made with borosilicate glass at room temperature. Such cells may be useful in compact vapor-cell atomic clocks and as a micro fabricated platform suitable for the generation of cold atom samples.

10.
J Neurosci ; 34(43): 14324-7, 2014 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-25339745

RESUMEN

Magnetoencephalography has long held the promise of providing a noninvasive tool for localizing epileptic seizures in humans because of its high spatial resolution compared with the scalp EEG. Yet, this promise has been elusive, not because of a lack of sensitivity or spatial resolution but because the large size and immobility of present cryogenic (superconducting) technology prevent long-term telemetry required to capture these very infrequent epileptiform events. To circumvent this limitation, we used Micro-Electro-Mechanical Systems technology to construct a noncryogenic (room temperature) microfabricated atomic magnetometer ("magnetrode") based on laser spectroscopy of rubidium vapor and similar in size and flexibility to scalp EEG electrodes. We tested the magnetrode by measuring the magnetic signature of epileptiform discharges in a rat model of epilepsy. We were able to measure neuronal currents of single epileptic discharges and more subtle spontaneous brain activity with a high signal-to-noise ratio approaching that of present superconducting sensors. These measurements are a promising step toward the goal of high-resolution noninvasive telemetry of epileptic events in humans with seizure disorders.


Asunto(s)
Potenciales de Acción/fisiología , Epilepsia/fisiopatología , Magnetoencefalografía/métodos , Magnetometría/métodos , Microtecnología/métodos , Animales , Epilepsia/patología , Masculino , Ratas , Ratas Sprague-Dawley
11.
Angew Chem Int Ed Engl ; 53(37): 9766-70, 2014 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-25081416

RESUMEN

Nuclear magnetic resonance (NMR) relaxometry and diffusometry are important tools for the characterization of heterogeneous materials and porous media, with applications including medical imaging, food characterization and oil-well logging. These methods can be extremely effective in applications where high-resolution NMR is either unnecessary, impractical, or both, as is the case in the emerging field of portable chemical characterization. Here, we present a proof-of-concept experiment demonstrating the use of high-sensitivity optical magnetometers as detectors for ultra-low-field NMR relaxation and diffusion measurements.

12.
Opt Lett ; 38(5): 661-3, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-23455257

RESUMEN

We measure the number of atoms N trapped in a conventional vapor-cell magneto-optic trap (MOT) using beams that have a diameter d in the range 1-5 mm. We show that the N is proportional to d(3.6) scaling law observed for larger MOTs is a robust approximation for optimized MOTs with beam diameters as small as 3 mm. For smaller beams, the description of the scaling depends on how d is defined. The most consistent picture of the scaling is obtained when d is defined as the diameter where the intensity profile of the trapping beams decreases to the saturation intensity. Using this definition, N scales as d(6) for d<2.3 mm but, at larger d, N still scales as d(3.6).

13.
Nat Commun ; 14(1): 3501, 2023 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-37311737

RESUMEN

Atomic beams are a longstanding technology for atom-based sensors and clocks with widespread use in commercial frequency standards. Here, we report the demonstration of a chip-scale microwave atomic beam clock using coherent population trapping (CPT) interrogation in a passively pumped atomic beam device. The beam device consists of a hermetically sealed vacuum cell fabricated from an anodically bonded stack of glass and Si wafers in which lithographically defined capillaries produce Rb atomic beams and passive pumps maintain the vacuum environment. A prototype chip-scale clock is realized using Ramsey CPT spectroscopy of the atomic beam over a 10 mm distance and demonstrates a fractional frequency stability of ≈1.2 × 10-9/[Formula: see text] for integration times, τ, from 1 s to 250 s, limited by detection noise. Optimized atomic beam clocks based on this approach may exceed the long-term stability of existing chip-scale clocks, and leading long-term systematics are predicted to limit the ultimate fractional frequency stability below 10-12.

14.
Rev Sci Instrum ; 94(3): 035002, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37012772

RESUMEN

We have developed an atomic magnetometer based on the rubidium isotope 87Rb and a microfabricated silicon/glass vapor cell for the purpose of qualifying the instrument for space flight during a ride-along opportunity on a sounding rocket. The instrument consists of two scalar magnetic field sensors mounted at 45° angle to avoid measurement dead zones, and the electronics consist of a low-voltage power supply, an analog interface, and a digital controller. The instrument was launched into the Earth's northern cusp from Andøya, Norway on December 8, 2018 on the low-flying rocket of the dual-rocket Twin Rockets to Investigate Cusp Electrodynamics 2 mission. The magnetometer was operated without interruption during the science phase of the mission, and the acquired data were compared favorably with those from the science magnetometer and the model of the International Geophysical Reference Field to within an approximate fixed offset of about 550 nT. Residuals with respect to these data sources are plausibly attributed to offsets resulting from rocket contamination fields and electronic phase shifts. These offsets can be readily mitigated and/or calibrated for a future flight experiment so that the demonstration of this absolute-measuring magnetometer was entirely successful from the perspective of increasing the technological readiness for space flight.

15.
Artículo en Inglés | MEDLINE | ID: mdl-38915391

RESUMEN

Vector atomic magnetometers that incorporate electromagnetically induced transparency (EIT) allow for precision measurements of magnetic fields that are sensitive to the directionality of the observed field by virtue of fundamental physics. However, a practical methodology of accurately recovering the longitudinal angle of the local field through observations of EIT spectra has not been established. In this work, we address this problem of angle determination with an unsupervised machine learning algorithm utilizing nonlinear dimensionality reduction. The proposed algorithm was developed to interface with spectroscopic measurements from an EIT-based atomic rubidium magnetometer and uses kernel principal component analysis (KPCA) as an unsupervised feature extraction tool. The resulting KPCA features allow each EIT spectrum measurement to be represented by a single coordinate in a new reduced dimensional feature space, thereby streamlining the process of angle determination. A supervised support vector regression (SVR) machine was implemented to model the resulting relationship between the KPCA projections and field direction. If the magnetometer is configured so that the azimuthal angle of the field is defined with a polarization lock, the KPCA-SVR algorithm is capable of predicting the longitudinal angle of the local magnetic field within 1 degree of accuracy and the magnitude of the absolute field with a resolution of 70 nT. The combined scalar and angular sensitivity of this method make the KPCA-enabled EIT magnetometer competitive with conventional vector magnetometry methods.

16.
Opt Express ; 18(26): 27167-72, 2010 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-21196993

RESUMEN

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.


Asunto(s)
Rayos Láser , Magnetismo/instrumentación , Campos Electromagnéticos , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización
17.
Phys Rev Lett ; 105(10): 101101, 2010 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-20867507

RESUMEN

We propose an experiment using optically trapped and cooled dielectric micro-spheres for the detection of short-range forces. The center-of-mass motion of a microsphere trapped in vacuum can experience extremely low dissipation and quality factors of 10(12), leading to yoctonewton force sensitivity. Trapping the sphere in an optical field enables positioning at less than 1 µm from a surface, a regime where exotic new forces may exist. We expect that the proposed system could advance the search for non-Newtonian gravity forces via an enhanced sensitivity of 10(5)-10(7) over current experiments at the 1 µm length scale. Moreover, our system may be useful for characterizing other short-range physics such as Casimir forces.

18.
Sci Rep ; 10(1): 16590, 2020 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-33024172

RESUMEN

We show that micro-machined non-evaporable getter pumps (NEGs) can extend the time over which laser cooled atoms can be produced in a magneto-optical trap (MOT), in the absence of other vacuum pumping mechanisms. In a first study, we incorporate a silicon-glass microfabricated ultra-high vacuum (UHV) cell with silicon etched NEG cavities and alumino-silicate glass (ASG) windows and demonstrate the observation of a repeatedly-loading MOT over a 10 min period with a single laser-activated NEG. In a second study, the capacity of passive pumping with laser activated NEG materials is further investigated in a borosilicate glass-blown cuvette cell containing five NEG tablets. In this cell, the MOT remained visible for over 4 days without any external active pumping system. This MOT observation time exceeds the one obtained in the no-NEG scenario by almost five orders of magnitude. The cell scalability and potential vacuum longevity made possible with NEG materials may enable in the future the development of miniaturized cold-atom instruments.

19.
Laser Photon Rev ; 14(6)2020.
Artículo en Inglés | MEDLINE | ID: mdl-38847002

RESUMEN

Lasers precisely stabilized to known transitions between energy levels in simple, well-isolated quantum systems such as atoms and molecules are essential for a plethora of applications in metrology and optical communications. The implementation of such spectroscopic systems in a chip-scale format would allow to reduce cost dramatically and would open up new opportunities in both photonically integrated platforms and free-space applications such as lidar. Here the design, fabrication, and experimental characterization of a molecular cladded waveguide platform based on the integration of serpentine nanoscale photonic waveguides with a miniaturized acetylene chamber is presented. The goal of this platform is to enable cost-effective, miniaturized, and low power optical frequency references in the telecommunications C band. Finally, this platform is used to stabilize a 1.5 µm laser with a precision better than 400 kHz at 34 s. The molecular cladded waveguide platform introduced here could be integrated with components such as on-chip modulators, detectors, and other devices to form a complete on-chip laser stabilization system.

20.
Sci Adv ; 6(9): eaax6230, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32158936

RESUMEN

Microresonator-based soliton frequency combs, microcombs, have recently emerged to offer low-noise, photonic-chip sources for applications, spanning from timekeeping to optical-frequency synthesis and ranging. Broad optical bandwidth, brightness, coherence, and frequency stability have made frequency combs important to directly probe atoms and molecules, especially in trace gas detection, multiphoton light-atom interactions, and spectroscopy in the extreme ultraviolet. Here, we explore direct microcomb atomic spectroscopy, using a cascaded, two-photon 1529-nm atomic transition in a rubidium micromachined cell. Fine and simultaneous repetition rate and carrier-envelope offset frequency control of the soliton enables direct sub-Doppler and hyperfine spectroscopy. Moreover, the entire set of microcomb modes are stabilized to this atomic transition, yielding absolute optical-frequency fluctuations at the kilohertz level over a few seconds and <1-MHz day-to-day accuracy. Our work demonstrates direct atomic spectroscopy with Kerr microcombs and provides an atomic-stabilized microcomb laser source, operating across the telecom band for sensing, dimensional metrology, and communication.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA