Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Biomed Res Int ; 2019: 1932191, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30984776

RESUMEN

Two-dimensional (2D) planning on standard radiographs for total hip arthroplasty may not be sufficiently accurate to predict implant sizing or restore leg length and femoral offset, whereas 3D planning avoids magnification and projection errors. Furthermore, weightbearing measures are not available with computed tomography (CT) and leg length and offset are rarely checked postoperatively using any imaging modality. Navigation can usually achieve a surgical plan precisely, but the choice of that plan remains key, which is best guided by preoperative planning. The study objectives were therefore to (1) evaluate the accuracy of stem/cup size prediction using dedicated 3D planning software based on biplanar radiographic imaging under weightbearing and (2) compare the preplanned leg length and femoral offset with the postoperative result. This single-centre, single-surgeon prospective study consisted of a cohort of 33 patients operated on over 24 months. The routine clinical workflow consisted of preoperative biplanar weightbearing imaging, 3D surgical planning, navigated surgery to execute the plan, and postoperative biplanar imaging to verify the radiological outcomes in 3D weightbearing. 3D planning was performed with the dedicated hipEOS® planning software to determine stem and cup size and position, plus 3D anatomical and functional parameters, in particular variations in leg length and femoral offset. Component size planning accuracy was 94% (31/33) within one size for the femoral stem and 100% (33/33) within one size for the acetabular cup. There were no significant differences between planned versus implanted femoral stem size or planned versus measured changes in leg length or offset. Cup size did differ significantly, tending towards implanting one size larger when there was a difference. Biplanar radiographs plus hipEOS planning software showed good reliability for predicting implant size, leg length, and femoral offset and postoperatively provided a check on the navigated surgery. Compared to previous studies, the predictive results were better than 2D planning on conventional radiography and equal to 3D planning on CT images, with lower radiation dose, and in the weightbearing position.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Imagenología Tridimensional/métodos , Osteoartritis/diagnóstico por imagen , Radiografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/fisiopatología , Osteoartritis/cirugía , Cuidados Preoperatorios , Diseño de Prótesis , Programas Informáticos , Tomografía Computarizada por Rayos X , Soporte de Peso
2.
Orthop Traumatol Surg Res ; 103(4): 531-536, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28323248

RESUMEN

BACKGROUND: In total hip arthroplasty (THA), the acetabular cup and femoral stem must be correctly sized and positioned to avoid intraoperative and postoperative complications, achieve good functional outcomes and ensure long-term survival. Current two-dimensional (2D) techniques do not provide sufficient accuracy, while low-dose biplanar X-rays (EOS) had not been assessed in this indication. Therefore, we performed a case-control study to : (1) evaluate the prediction of stem and cup size for a new 3D planning technique (stereoradiographic imaging plus 3D modeling) in comparison to 2D templating on film radiographs and (2) evaluate the accuracy and reproducibility of this 3D technique for preoperative THA planning. HYPOTHESIS: Accuracy and reproducibility are better with the 3D vs. 2D method. PATIENTS AND METHODS: Stem and cup sizes were retrospectively determined by two senior surgeons, twice, for a total of 31 unilateral primary THA patients in this pilot study, using 3D preplanning software on low-dose biplanar X-rays and with 2D templating on conventional anteroposterior (AP) film radiographs. Patients with a modular neck or dual-mobility prosthesis were excluded. All patients but one had primary osteoarthritis; one following trauma did not have a cup implanted. The retrospectively planned sizes were compared to the sizes selected during surgery, and intraclass coefficients (ICC) calculated. RESULTS: 3D planning predicted stem size more accurately than 2D templating: stem sizes were planned within one size in 26/31 (84%) of cases in 3D versus 21/31 (68%) in 2D (P=0.04). 3D and 2D planning accuracies were not significantly different for cup size: cup sizes were planned within one size in 28/30 (92%) of cases in 3D versus 26/30 (87%) in 2D (P=0.30). ICC for stem size were 0.88 vs. 0.91 for 3D and 2D, respectively. Inter-operator ICCs for cup size were 0.84 vs. 0.71, respectively. Repetitions of the 3D planning were within one size (except one stem), with the majority predicting the same size. DISCUSSION: Increased accuracy in 3D may be due to the use of actual size (non-magnified) images, and judging fit on AP and lateral images simultaneously. Results for other implant components may differ from those presented. Size selection may improve further with planning experience, based on a feedback loop between planning and surgical execution. LEVEL OF EVIDENCE: Level III. Retrospective case-control study.


Asunto(s)
Acetábulo/diagnóstico por imagen , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Proyectos Piloto , Cuidados Preoperatorios , Diseño de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA