Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Endosc Int Open ; 8(10): E1273-E1279, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33015328

RESUMEN

Background and study aims Endoscopic submucosal dissection (ESD) with the double-balloon endoluminal intervention platform (DEIP) is a novel technique for removal of complex colon polyps (> 2 cm) or those located in anatomically difficult positions. DEIP helps create a therapeutic zone with improved visualization and stability, facilitating polyp removal. We aimed to compare the outcomes of DEIP with the conventional cap-assisted ESD (standard ESD) technique for colon polyp resection, in particular, the ability to complete the ESD procedure without resorting to hybrid ESD or piecemeal resection. Patients and methods This was a retrospective cohort of all patients who underwent colon ESD in a single large tertiary referral center between September 2016 and October 2019. Information was collected on patient demographics and study outcomes including procedure time, rates of en bloc and curative resection, operative and postoperative complications. All patients were followed up for 1 month after the procedure. Results 111 patients were included in the study (DEIP 60, standard ESD 51). There was no statistically significant difference between mean procedures time (±â€ŠSD) in the two groups, mean (81.9 ±â€Š35.4 min standard vs. 96.4 ±â€Š42.2 min in DEIP). Mean polyp size (±â€ŠSD) was similar between the two groups (7.6 ±â€Š6.0 cm 2 vs. 6.2 ±â€Š5.5 cm 2 , P  = .2). There were no significant differences in en bloc and curative resection rates or operative and postoperative complications between the two techniques. Conclusion Procedure time was similar using both techniques. However, DEIP enabled the entire procedure to be performed using the ESD technique without resorting to snare resection, which may affect the en bloc and curative resection rate. There were no significant differences in en bloc and curative resection rates between the two groups, probably due to the small sample size.

2.
Nat Commun ; 5: 3459, 2014 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-24619206

RESUMEN

Improving small interfering RNA (siRNA) efficacy in target cell populations remains a challenge to its clinical implementation. Here, we report a chemical modification, consisting of phosphorodithioate (PS2) and 2'-O-Methyl (2'-OMe) MePS2 on one nucleotide that significantly enhances potency and resistance to degradation for various siRNAs. We find enhanced potency stems from an unforeseen increase in siRNA loading to the RNA-induced silencing complex, likely due to the unique interaction mediated by 2'-OMe and PS2. We demonstrate the therapeutic utility of MePS2 siRNAs in chemoresistant ovarian cancer mouse models via targeting GRAM domain containing 1B (GRAMD1B), a protein involved in chemoresistance. GRAMD1B silencing is achieved in tumours following MePS2-modified siRNA treatment, leading to a synergistic anti-tumour effect in combination with paclitaxel. Given the previously limited success in enhancing siRNA potency with chemically modified siRNAs, our findings represent an important advance in siRNA design with the potential for application in numerous cancer types.


Asunto(s)
Fosfatos/química , ARN Interferente Pequeño/química , Complejo Silenciador Inducido por ARN/química , Complejo Silenciador Inducido por ARN/metabolismo , Animales , Línea Celular Tumoral , Femenino , Humanos , Inmunohistoquímica , Ratones , Ratones Desnudos , ARN Interferente Pequeño/uso terapéutico , Ensayos Antitumor por Modelo de Xenoinjerto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA