Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(2): 317-327, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38105426

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers. METHODS: We included 179 patients with paroxysmal AF receiving first-time PVI with different ablation technologies: standard RFA (30-40 W/20-30 s, n = 52), power-controlled HPSD (70 W/5-7 s, n = 60), temperature-controlled HPSD (90 W/4 s, n = 32), and PFA (biphasic, bipolar waveform, n = 35). High-sensitivity cardiac troponin T (hs-cTnT), creatine kinase (CK), CK MB isoform (CK-MB), and white blood cell (WBC) count were determined before and after ablation. RESULTS: Baseline characteristics were well-balanced between groups (age 63.1 ± 10.3 years, 61.5% male). Postablation hs-cTnT release was significantly higher with PFA (1469.3 ± 495.0 ng/L), HPSD-70W (1322.3 ± 510.6 ng/L), and HPSD-90W (1441.2 ± 409.9 ng/L) than with standard RFA (1045.9 ± 369.7 ng/L; p < .001). CK and CK-MB release was increased with PFA by 3.4-fold and 5.8-fold, respectively, as compared to standard RFA (p < .001). PFA was associated with the lowest elevation in WBC (Δ1.5 ± 1.5 × 109 /L), as compared to standard RFA (Δ3.8 ± 2.5 × 109 /L, p < .001), HPSD-70W (Δ2.7 ± 1.7 × 109 /L, p = .037), and HPSD-90W (Δ3.6 ± 2.5 × 109 /L, p < .001). CONCLUSION: Among the four investigated ablation technologies, PFA was associated with the highest myocardial injury and the lowest inflammatory reaction.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Lesiones Cardíacas , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Forma MB de la Creatina-Quinasa , Inflamación/diagnóstico , Venas Pulmonares/cirugía , Troponina T , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Recurrencia
2.
Pacing Clin Electrophysiol ; 47(8): 994-1003, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38728067

RESUMEN

BACKGROUND: Lesion durability and transmurality are crucial for successful radiofrequency (RF) ablation. This study provides a model of real-time RF lesion visualization and insights into the role of underlying parameters, as local impedance (LI). METHODS: A force-sensing, LI-sensing catheter was used for lesion creation in an ex vivo model involving cross-sections of porcine cardiac preparations. During 60 s of RF application, one measurement per second was performed regarding lesion size and available ablation parameters. In total, 1847 measurements from n = 36 lesions were performed. Power (20-50 W) and contact force (1-5 g, 10-15 g, 20-25 g) were systematically alternated. RESULTS: Lesion formation was most prominent in the first seconds of RF application during which nonlinear lesion growth was observed (max. 1.08 mm/s for lesion depth and 2.71 mm/s for lesion diameter). Power levels determined the extent of lesion formation in the early phase. After 20 s, lesion size growth velocity approaches 0.1 mm/s at all power levels. LI changes were also highest in the first seconds (up to - 12 Ω/s) and decreased to less than - 0.1Ω/s after prolonged application. CONCLUSION: Lesion formation in irrigated RF ablation is a nonlinear process. Final lesion size resulting from an RF application is mainly influenced by high rates of lesion growth in the first seconds of ablation. LI seems to be a good surrogate for differentiating changes in lesion formation.


Asunto(s)
Ablación por Catéter , Porcinos , Animales , Ablación por Catéter/métodos , Sistemas de Computación , Impedancia Eléctrica , Técnicas In Vitro , Ablación por Radiofrecuencia/métodos , Cirugía Asistida por Computador/métodos
3.
Europace ; 25(2): 408-416, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36504120

RESUMEN

AIMS: This retrospective study sought to compare complication rates and efficacy of power-controlled very high-power short-duration (vHPSD) and conventional catheter ablation in a large cohort of patients with atrial fibrillation (AF). METHODS AND RESULTS: We analyzed 1115 consecutive patients with AF (38.7% paroxysmal, 61.3% persistent) who received first-time catheter ablation at our centre from 2015 to 2021. Circumferential pulmonary vein isolation ± additional substrate ablation using an irrigated-tip catheter was performed with vHPSD (70 W/5-7 s or 60 W/7-10 s) in 574 patients and with conventional power (30-35 W/15-30 s) in 541 patients. Baseline characteristics were well-balanced between groups (mean age 65.1 ± 11.2 years, 63.4% male). The 30-day incidence of cardiac tamponade [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598], pericardial effusion ≥ 10 mm [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598] and transient ischaemic attack [1/574 (0.17%) vs. 2/541 (0.37%), P = 0.529] was not significantly different between vHPSD and conventional ablation. No stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Procedure (122.2 ± 46.8 min vs. 155.0 ± 50.5 min, P < 0.001), radiofrequency (22.4 ± 19.3 min vs. 52.9 ± 22.0 min, P < 0.001), and fluoroscopy (8.1 ± 7.2 vs. 9.2 ± 7.4, P = 0.016) duration were significantly shorter in the vHPSD group. At 12 months follow-up, freedom of any atrial arrhythmia was 44.1% vs. 34.2% (P = 0.010) in persistent AF and 78.1% vs. 70.2% in paroxysmal AF (P = 0.068). CONCLUSION: vHPSD ablation is as safe as conventional ablation and is associated with an improved long-term efficacy in persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Catéteres , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
4.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37067822

RESUMEN

AIMS: Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated. METHODS AND RESULTS: A total of 130 CIED patients performed 561 charges of four BEVs and a test vehicle (350 kW charge capacity) using high-power charging stations under continuous 6-lead electrocardiogram monitoring. The charging cable was placed directly over the CIED, and devices were programmed to maximize the chance of EMI detection. Cardiac implantable electronic devices were re-interrogated after patients charged all BEVs and the test vehicle for evidence of EMI. There were no incidences of EMI, specifically no over-sensing, pacing inhibition, inappropriate tachycardia detection, mode switching, or spontaneous reprogramming. The risk of EMI on a patient-based analysis is 0/130 [95% confidence interval (CI) 0%-2%], and the risk of EMI on a charge-based analysis is 0/561 (95% CI 0%-0.6%). The effective magnetic field along the charging cable was 38.65 µT and at the charging station was 77.9 µT. CONCLUSIONS: The use of electric cars with high-power chargers by patients with cardiac devices appears to be safe with no evidence of clinically relevant EMI. Reasonable caution, by minimizing the time spent in close proximity with the charging cables, is still advised as the occurrence of very rare events cannot be excluded from our results.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Campos Electromagnéticos/efectos adversos , Suministros de Energía Eléctrica , Corazón
5.
Pacing Clin Electrophysiol ; 46(10): 1170-1181, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37616376

RESUMEN

BACKGROUND: The influence of power, duration and contact force (CF) on radiofrequency (RF) lesion formation is well known, whereas data on local impedance (LI) and electrode-tissue-coverage (ETC) is scarce. The objective was to investigate their effect on lesion formation in an ex vivo model. METHODS AND RESULTS: An ex vivo model was developed utilizing cross-sections of porcine heart preparations and a force-sensing, LI-measuring catheter. N = 72 lesion were created systematically varying ETC (minor/full), CF (1-5 g, 10-15 g, 20-25 g) and power (20 W, 30 W, 40 W, 50 W). In minor ETC, the distal tip of the catheter was in electric contact with the tissue, in full ETC the whole catheter tip was embedded within the tissue. Lesion size and all parameters were measured once per second (n = 3320). LI correlated strongly with lesion depth (r = -0.742 for ΔLI; r = 0.781 for %LI-drop). Lesions in full ETC were significantly wider and deeper compared to minor ETC (p < .001) and steam pops were more likely. Baseline LI, ΔLI, and %LI-drop were significantly higher in full ETC (p < .001). In lesions resulting in steam pops, baseline LI, and ΔLI were significantly higher. The influence of CF on lesion size was higher in minor ETC than in full ETC. CONCLUSIONS: ETC is a main determinant of lesion size and occurrence of steam pops. Baseline LI and LI-drop are useful surrogate parameters for real-time assessment of ETC and ΔLI correlates strongly with lesion size.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Impedancia Eléctrica , Ablación por Catéter/métodos , Electrodos
6.
BMC Musculoskelet Disord ; 22(1): 849, 2021 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-34610804

RESUMEN

BACKGROUND: For optimal prosthetic anchoring in omarthritis surgery, a differentiated knowledge on the mineralisation distribution of the glenoid is important. However, database on the mineralisation of diseased joints and potential relations with glenoid angles is limited. METHODS: Shoulder specimens from ten female and nine male body donors with an average age of 81.5 years were investigated. Using 3D-CT-multiplanar reconstruction, glenoid inclination and retroversion angles were measured, and osteoarthritis signs graded. Computed Tomography-Osteoabsorptiometry (CT-OAM) is an established method to determine the subchondral bone plate mineralisation, which has been demonstrated to serve as marker for the long-term loading history of joints. Based on mineralisation distribution mappings of healthy shoulder specimens, physiological and different CT-OAM patterns were compared with glenoid angles. RESULTS: Osteoarthritis grades were 0-I in 52.6% of the 3D-CT-scans, grades II-III in 34.3%, and grade IV in 13.2%, with in females twice as frequently (45%) higher grades (III, IV) than in males (22%, III). The average inclination angle was 8.4°. In glenoids with inclination ≤10°, mineralisation was predominantly centrally distributed and tended to shift more cranially when the inclination raised to > 10°. The average retroversion angle was - 5.2°. A dorsally enhanced mineralisation distribution was found in glenoids with versions from - 15.9° to + 1.7°. A predominantly centrally distributed mineralisation was accompanied by a narrower range of retroversion angles between - 10° to - 0.4°. CONCLUSIONS: This study is one of the first to combine CT-based analyses of glenoid angles and mineralisation distribution in an elderly population. The data set is limited to 19 individuals, however, indicates that superior inclination between 0° and 10°-15°, and dorsal version ranging between - 9° to - 3° may be predominantly associated with anterior and central mineralisation patterns previously classified as physiological for the shoulder joint. The current basic research findings may serve as basic data set for future studies addressing the glenoid geometry for treatment planning in omarthritis.


Asunto(s)
Cuerpo Humano , Articulación del Hombro , Anciano , Anciano de 80 o más Años , Calcificación Fisiológica , Femenino , Humanos , Masculino , Escápula , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X
7.
Sci Rep ; 14(1): 25370, 2024 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-39455654

RESUMEN

The question of optimal timing for catheter ablation of atrial fibrillation (AF) to achieve best outcomes remains a crucial clinical issue. As AF occurs less frequently in younger patients, data regarding Diagnosis-to-Ablation Time (DAT) is especially limited in patients under the age of 55 years with persistent AF. We therefore analyzed the temporal relationship between initial AF presentation and timing of catheter ablation in this cohort. We conducted a retrospective single-centre study of patients ≤ 55 years with persistent AF who underwent first-time catheter ablation at our center. The cohort was divided into patients that underwent catheter ablation after diagnosis of persistent AF within a DAT of ≤ 12 months and patients with a DAT of > 12 months. A total of 101 patients (median age 51 years; female n = 19 (18.8%)) with persistent AF were included. Ablation was performed within 12 months ("early DAT") in 51 patients and > 12 months ("late DAT") in 50 patients. Pulmonary vein isolation was performed using high-power short-duration (HPSD) radiofrequency ablation. Median DAT was 5 months (1-12 months) in the early ablation group and 36 months (13-240 months) in the late ablation group. The median follow-up was 11.3 months (0.03-37.1 months). The rate of any atrial arrhythmia recurrence after a 30-day blanking period was significantly lower in the early DAT group (13/51 patients; 25.5%) as compared to the late DAT group (26/50 patients; 52.0%) (log rank test; p = 0.003). Catheter ablation performed > 12 months after the initial AF diagnosis was an independent predictor for the occurrence of any atrial arrythmia (OR: 2.58; (95%-CI: 1.32-5.07). Early first-time catheter ablation (DAT ≤ 12 months) in patients ≤ 55 years with persistent AF is associated with a significantly lower rate of arrhythmia recurrence.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Femenino , Masculino , Persona de Mediana Edad , Ablación por Catéter/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto , Recurrencia , Factores de Tiempo , Venas Pulmonares/cirugía
8.
Artículo en Inglés | MEDLINE | ID: mdl-38775921

RESUMEN

BACKGROUND: Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of cardiac implantable electronic devices (CIEDs) in the form of electromagnetic interference (EMI). The aim of our study was to assess the impact of PFA on CIEDs. METHODS: PFA lesions (45 per CIED) were applied from the Farapulse system to CIEDs (< 5 cm from the lead tip and < 15 cm from the generator). All devices were checked before and after PFA application for proper sensing and pacing functionality as well as for integrity of shock circuits in ICDs using a heart simulator. Moreover, devices were then interrogated for any spontaneous reprogramming, mode switching or other EMI effects. RESULTS: In total, 44 CIEDs were tested (16 pacemaker, 21 ICDs, 7 CRT-P/D) with 1980 PFA applications. There was no change in device settings, functionality and electrical parameters, and there was no macroscopic damage to the devices. The risk of damage to the electric components or leads on a patient-based analysis is 0/44 (95% CI 0-8%) and on a PFA pulse-based analysis is 0/1980 (95% CI 0-0.2%). Clinically relevant EMI appeared with oversensing and pacing inhibition but not tachycardia detection. CONCLUSIONS: Bipolar PFA appears safe and does not result in damage to CIEDs or leads. Clinically relevant EMI does occur, but appropriate peri-procedural programming may mitigate this. In vivo studies are needed to confirm our findings.

9.
Clin Neuroradiol ; 32(1): 185-196, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34613421

RESUMEN

PURPOSE: In patients with drug-resistant focal epilepsy, surgical resection is often the only treatment option to achieve long-term seizure control. Prior to brain surgery involving potential language areas, identification of hemispheric language dominance is crucial. Our group developed and validated a functional magnetic resonance imaging (fMRI) battery of four pediatric language tasks. The present study aimed at optimizing fMRI data acquisition and analysis using these tasks. METHODS: We retrospectively analyzed speech fMRI examinations of 114 neuropediatric patients (age range 5.8-17.8 years) who were examined prior to possible epilepsy surgery. In order to evaluate hemispheric language dominance, 1-4 language tasks (vowel identification task VIT, word-chain task WCT, beep-story task BST, synonym task SYT) were measured. RESULTS: Language dominance was classified using fMRI activation in the 13 validly lateralizing ROIs (VLR) in frontal, temporal and parietal lobes and cerebellum of the recent validation study from our group: 47/114 patients were classified as left-dominant, 34/114 as bilateral and 6/114 as right-dominant. In an attempt to enlarge the set of VLR, we then compared for each task agreement of these ROI activations with the classified language dominance. We found four additional task-specific ROIs showing concordant activation and activation in ≥ 10 sessions, which we termed validly lateralizing (VLRnew). The new VLRs were: for VIT the temporal language area and for SYT the middle frontal gyrus, the intraparietal sulcus and cerebellum. Finally, in order to find the optimal sequence of measuring the different tasks, we analyzed the success rates of single tasks and all possible task combinations. The sequence 1) VIT 2) WCT 3) BST 4) SYT was identified as the optimal sequence, yielding the highest chance to obtain reliable results even when the fMRI examination has to be stopped, e.g., due to lack of cooperation. CONCLUSION: Our suggested task order together with the enlarged set of VLRnew may contribute to optimize pediatric speech fMRI in a clinical setting.


Asunto(s)
Imagen por Resonancia Magnética , Habla , Adolescente , Algoritmos , Mapeo Encefálico/métodos , Niño , Preescolar , Dominancia Cerebral/fisiología , Lateralidad Funcional/fisiología , Humanos , Estudios Retrospectivos , Habla/fisiología
10.
Gene ; 827: 146470, 2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35381313

RESUMEN

INTRODUCTION: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is now usually referred to as arrhythmogenic cardiomyopathy (ACM) because of the possible left and biventricular affection. In recent years, it has been shown that early-stage ACM, especially in women carrying a disease-causing variant in the DSP gene, may present with clinical signs of myocarditis. CASE PRESENTATION: The female patient was diagnosed with myocarditis based on arrhythmia and findings on magnetic resonance imaging at the age of 24 years. An additional performed myocardial biopsy confirmed a lymphocytic inflammatory reaction. Subsequently, the patient experienced cardiac arrest because of ventricular fibrillation and was resuscitated. As a result, she received an implantable cardioverter defibrillator, and repeated ablations of recurrent ventricular tachycardia were performed. After four years, molecular genetic testing identified the heterozygous, likely pathogenic nonsense variant c.4789G > T, p.(Glu1597*) in DSP (NM_004415.4). Based on this finding, ACM could be diagnosed, and a heart transplantation was performed only a few months later because of rapid disease progression. DISCUSSION: Truncating variants in DSP have been associated with fulminant progression of arrhythmia. However, the currently used ARVC task force criteria are inadequate to detect DSP-associated ACM with left dominant presentation. Moreover, the initial diagnosis of myocarditis may distract from a more extensive search for other causes. Consequently, in cases of recurrent or unusually prolonged myocarditis, especially if present without detected pathogens, molecular genetic testing should be considered.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Miocarditis , Adulto , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/genética , Desmoplaquinas/genética , Femenino , Heterocigoto , Humanos , Imagen por Resonancia Magnética , Miocarditis/diagnóstico , Miocarditis/genética , Adulto Joven
11.
Heart Rhythm ; 19(4): 648-655, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34958942

RESUMEN

BACKGROUND: Catheter ablation in adult congenital heart disease (ACHD) patients is a critical treatment strategy for complex arrhythmias including atrial fibrillation (AF) and atrial tachycardia (AT). In addition to vitamin K antagonists (VKAs), direct oral anticoagulants (DOACs) are increasingly used in this patient population. OBJECTIVE: The purpose of this study was to assess the safety of catheter ablation in ACHD patients on uninterrupted oral anticoagulation with VKA or DOAC, examining thromboembolic, bleeding, and vascular access complications. METHODS: Retrospective analysis of 234 ACHD patients with simple (n = 83), moderate (n = 66), or complex (n = 85) CHD (mean age 46 years) undergoing 368 ablation procedures on uninterrupted oral anticoagulation with VKA (45.4%) or DOAC (54.6%) was undertaken. Arrhythmias were AF in 97, right AT in 181, left AT in 65, or a combination of AF and AT in 25. RESULTS: No thromboembolic complications occurred. Major complications occurred in 4 patients (1.1%; 1 VKA, 3 DOAC), including retroperitoneal hematoma in 2 and arteriovenous (AV) fistula requiring surgical treatment in 2. Minor bleeding or vascular access complications occurred in 46 cases (12.5%), including hematomas >5 cm in 26, AV fistulas (not requiring surgical intervention) in 13, and pseudoaneurysms in 7 (thrombin injection in 3/7). Overall, no significant difference was found between DOAC (14.9%) and VKA groups (12.0%; P = .411). CONCLUSION: Catheter ablation in ACHD patients on uninterrupted oral anticoagulation with VKA or DOAC is feasible and safe. No thromboembolic events occurred, and major bleeding or vascular access complications were rare. No significant differences regarding minor bleeding or vascular access complications between patients on DOAC or VKA were found.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Cardiopatías Congénitas , Administración Oral , Adulto , Anticoagulantes , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
12.
J Clin Med ; 11(22)2022 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-36431243

RESUMEN

Background: Femoral vascular access using the standard anatomic landmark-guided method is often limited by peripheral artery disease and obesity. We investigated the effect of ultrasound-guided vascular puncture (UGVP) on the rate of vascular complications in patients undergoing catheter ablation for atrial or ventricular arrhythmias. Methods: The data of 479 patients (59% male, mean age 68 years ± 11 years) undergoing catheter ablation for left atrial (n = 426; 89%), right atrial (n = 28; 6%) or ventricular arrhythmias (n = 28; 6%) were analyzed. All patients were on uninterrupted oral anticoagulants and heparin was administered intravenously during the procedure. Femoral access complications were compared between patients undergoing UGVP (n = 320; 67%) and patients undergoing a conventional approach (n = 159; 33%). Complication rates were also compared between patients with a BMI of >30 kg/m2 (n = 136) and patients with a BMI < 30 kg/m2 (n = 343). Results: Total vascular access complications including mild hematomas were n = 37 (7.7%). In the conventional group n = 17 (10.7%) and in the ultrasound (US) group n = 20 (6.3%) total vascular access complications occurred (OR 0.557, 95% CI 0.283−1.096). UGVP significantly reduced the risk of hematoma > 5 cm (OR 0.382, 95% CI 0.148, 0.988) or pseudoaneurysm (OR 0.160, 95% CI 0.032, 0.804). There was no significant difference between the groups regarding retroperitoneal hematomas or AV fistulas (p > 0.05). In patients with BMI > 30 kg/m2, UGVP led to a highly relevant reduction in the risk of total vascular access complications (OR 0.138, 95% CI 0.027, 0.659), hematomas > 5 cm (OR 0.051, 95% CI 0.000, 0.466) and pseudoaneurysms (OR 0.051, 95% CI 0.000, 0.466). Conclusion: UGVP significantly reduces vascular access complications. Patients with a BMI > 30 kg/m2 seem to particularly profit from a UGVP approach.

13.
Clin Res Cardiol ; 111(1): 85-95, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34519875

RESUMEN

BACKGROUND: Early recurrence of atrial tachyarrhythmia (ERAT) is common after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF), but its clinical significance in patients with persistent AF remains unclear. We sought to determine the predictive value of ERAT for rhythm outcome after RFCA for persistent AF. METHODS: The study included 207 consecutive patients (mean age 66.4 ± 10.7 years, male 66.2%) with persistent and long-standing persistent AF undergoing de novo pulmonary vein isolation (± atrial substrate ablation). All patients remained off antiarrhythmic drugs. ERAT was defined as any atrial arrhythmia ≥ 30 s occurring within the first 30 days. Late recurrence (LR) was determined during follow-up visits scheduled 1, 3, 6 and 12 months post-ablation using 7-day Holter ECGs. RESULTS: ERAT occurred in 143/207 (69.1%) patients as AF (60%) or atrial tachycardia (40%) and was persistent in 82% of cases. During a median follow-up of 22.2 months, LR occurred significantly more often in patients with ERAT than in patients without ERAT (92.3 vs. 43.8%, P < 0.001). The only independent predictors for LR were ERAT (OR 16.8, 95% CI 6.184-45.797, P < 0.001) and intraprocedural termination to sinus rhythm (OR 0.052, 95% CI 0.003-0.851, P = 0.038). Extending the blanking period from 30 to 90 days did not impact LR rates. CONCLUSION: ERAT following ablation of persistent AF is strongly associated with late arrhythmia recurrence, which challenges the assumption that ERAT represents merely a transient phenomenon. While limiting the blanking period to 30 days seems justified, the benefit of early re-ablations remains to be addressed in future studies.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Anciano , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA