Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 39(8): 1453-1460, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32172369

RESUMEN

Annual influenza epidemics cause substantial morbidity and mortality, and the majority of patients with influenza-like illness present to primary care. Point-of-care influenza tests could support treatment decisions. It is critical to establish analytic performance of these platforms in real-life patient samples before uptake can be considered. We aimed to assess the analytical performance and ease of use of the cobas® Liat® PCR POCT in detecting influenza A/B and RSV in samples collected from patients with influenza-like illness in primary care. Sensitivity and specificity of the cobas® Liat® POCT are calculated in comparison with a commercial laboratory-based PCR test (Fast-Track Respiratory Pathogens 21 Plus kit (Fast-Track Diagnostics)). Samples with discordant results were analysed additionally by the RespiFinder 2Smart (PathoFinder) using an Extended Gold Standard (EGS). Acceptability was scored on a five-point Likert scale as well as a failure mode analysis of the cobas® Liat® POCT was performed. Nasal and oropharyngeal swabs were obtained from 140 children and nasopharyngeal swabs from 604 adults (744 patients). The cobas® Liat® POCT had a sensitivity and specificity of 100% (95% CI 99-100%) and 98.1% (95%CI 96.3-99%) for influenza A, 100% (95% CI 97.7-100%) and 99.7% (95%CI 98.7-99.9%) for influenza B and 100% (95% CI 87.1-100%) and 99.4% (95%CI 98.6-99.8%) for RSV, respectively. According to trained lab technicians, the cobas® Liat® POCT was considered easy-to-use, with a fast turn-around-time. Cobas® Liat® POCT is a promising decentralised test platform for influenza A/B and RSV in primary care as it provides fairly rapid results with excellent analytic performance. Point-of-care influenza tests could support treatment decisions in primary care. Cobas® Liat® POCT is a promising decentralised test platform for influenza A/B and RSV in primary care as it provides fairly rapid results with excellent analytic performance.


Asunto(s)
Gripe Humana/diagnóstico , Atención Primaria de Salud , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Lactante , Virus de la Influenza A/genética , Virus de la Influenza A/aislamiento & purificación , Virus de la Influenza B/genética , Virus de la Influenza B/aislamiento & purificación , Gripe Humana/virología , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa , Valor Predictivo de las Pruebas , Infecciones por Virus Sincitial Respiratorio/virología , Virus Sincitial Respiratorio Humano/genética , Virus Sincitial Respiratorio Humano/aislamiento & purificación , Adulto Joven
2.
J Clin Virol ; 144: 104998, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34653942

RESUMEN

BACKGROUND: Influenza virus (IFV) is often encountered in primary care. Implementation of a rapid diagnostic test for its detection at the point-of-care would enable discrimination from other viral causes of influenza-like-illness (ILI) and might be helpful in individual patient management. In this study, the diagnostic performance of such a point-of-care platform was evaluated. METHODS: Respiratory samples (n = 1490) from ILI-patients in primary care in 15 European countries were collected as part of a prospective clinical trial. Both children (n = 252) and adults (n = 1238) were sampled during 3 consecutive periods of high IFV endemicity. Samples were analysed in a central laboratory, after storage at -70 °C, with the Idylla™ Respiratory Panel, detecting both IFV and RSV, on the Idylla™ platform. The Fast Track Diagnostics (FTD) Respiratory Pathogens 21 plus assay was used as reference. A subset of samples (n = 192) was analysed both fresh and after being frozen. RESULTS: The reference method detected IFV-A in 42% and IFV-B in 13% of the samples. Sensitivity of the Idylla for detection of IFV-A and IFV-B was 98.2% and 92.3% and specificity 97.7% and 98.4% respectively. False negative samples contained significantly lower viral loads than true positive samples (FTD mean Ct-value 30.7 versus 26.1 for IFV-A and 30.4 versus 25.1 for IFV-B, p < 0.001). Comparable results were obtained for Idylla analysis using fresh and frozen samples. CONCLUSIONS: The Idylla Respiratory Panel is a promising point-of-care test for detection of IFV in ILI patients due to its excellent diagnostic performance, minimal training requirements and limited hands-on time.


Asunto(s)
Virus de la Influenza A , Gripe Humana , Adulto , Niño , Humanos , Virus de la Influenza B , Gripe Humana/diagnóstico , Atención Primaria de Salud , Estudios Prospectivos , Estaciones del Año , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA