Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 92(2): 401-407, 2018 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-29388306

RESUMEN

BACKGROUND: Preliminary data comparing 3-dimensional computed tomography (3D-CT) to transesophageal echocardiography (TEE) for left atrial appendage occlusion (LAAO) indicates that 3D-CT provides more accurate measurements and improves case planning. Therefore, we conducted a pilot study comparing 3D-CT to TEE in occluder selection accuracy and procedural efficiency. METHODS: From May 2016 to February 2017, 24 patients were prospectively randomized to undergo LAAO using either TEE or 3D-CT. The primary endpoint was device accuracy while the secondary endpoints included # devices per case, # guide catheters used per case, # fluoroscopy angles used, procedure time, fluoroscopy time, radiation dose, and major adverse events (stroke, MI, device embolization, perforation, death). RESULTS: Procedure success was 100% and 92% for the 3D-CT and 2D-TEE cohorts respectively. Accuracy for 1st device selection 92% and 27% (P = .01) for 3D-CT and 2D-TEE respectively but with intra-procedural upsizing in the 2D-TEE cohort, the 2D-TEE cohort accuracy increased to 64% while the 3D-CT groups 92% was accurate (P = .33). Case planning using 3D-CT was significantly more efficient with respect to device utilization (CT 1.33 ± 0.7 vs. 2D-TEE 2.5 ± 1.2 P = .01), guide catheters (CT 1 vs. 2D-TEE 1.7 ± 0.8 P = .01) and procedure time (3D-CT 55 ± 17 min vs. 2D-TEE 73 ± 24 min P < .05). One major adverse event, a stroke occurred in the 2D-TEE group. CONCLUSION: In this single-center pilot study, CT guided LAAO case planning was associated with improved device selection accuracy and procedural efficiency. This study data supports the notion that comprehensive 3D assessment significantly simplifies LAAO, minimizing the time and number of steps needed.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco/métodos , Ecocardiografía Transesofágica , Imagenología Tridimensional , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Ecocardiografía Transesofágica/efectos adversos , Femenino , Humanos , Imagenología Tridimensional/efectos adversos , Masculino , Michigan , Proyectos Piloto , Valor Predictivo de las Pruebas , Impresión Tridimensional , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Intervencional/efectos adversos , Reproducibilidad de los Resultados , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos
2.
J Electrocardiol ; 51(1): 135-137, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28982476

RESUMEN

Peculiar electrocardiographic findings are not unusual and upon careful review can often be clarified. We present a case of an 85year-old woman with no previous cardiac history, incidentally discovered high grade atrioventricular block, and a puzzling electrocardiographic complex of unclear etiology which defies reasonable physiological explanations. The finding resembled a tiny QRS in a perfectly regular R-R interval following only non-conducted P-waves. The patient declined further work-up, so a definite cause could not be determined, but based on history, complex morphology, and inability to reproduce or explain the findings, we were compelled to accept the finding as an artifact.


Asunto(s)
Artefactos , Bloqueo Atrioventricular/fisiopatología , Electrocardiografía , Anciano de 80 o más Años , Bloqueo Atrioventricular/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos
3.
Am Heart J ; 185: 35-42, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28267473

RESUMEN

BACKGROUND: Prior studies have demonstrated cardiorespiratory fitness (CRF) to be a strong marker of cardiovascular health. However, there are limited data investigating the association between CRF and risk of progression to heart failure (HF). The purpose of this study was to determine the relationship between CRF and incident HF. METHODS: We included 66,329 patients (53.8% men, mean age 55 years) free of HF who underwent exercise treadmill stress testing at Henry Ford Health Systems between 1991 and 2009. Incident HF was determined using International Classification of Diseases, Ninth Revision codes from electronic medical records or administrative claim files. Cox proportional hazards models were performed to determine the association between CRF and incident HF. RESULTS: A total of 4,652 patients developed HF after a median follow-up duration of 6.8 (±3) years. Patients with incident HF were older (63 vs 54 years, P<.001) and had higher prevalence of known coronary artery disease (42.3% vs 11%, P<.001). Peak metabolic equivalents (METs) of task were 6.3 (±2.9) and 9.1 (±3) in the HF and non-HF groups, respectively. After adjustment for potential confounders, patients able to achieve ≥12 METs had an 81% lower risk of incident HF compared with those achieving <6 METs (hazard ratio 0.19 [95% CI 0.14-0.29], P for trend < .001). Each 1 MET achieved was associated with a 16% lower risk (hazard ratio 0.84 [95% CI 0.82-0.86], P<.001) of incident HF. CONCLUSIONS: Our analysis demonstrates that higher level of fitness is associated with a lower incidence of HF independent of HF risk factors.


Asunto(s)
Capacidad Cardiovascular , Insuficiencia Cardíaca/epidemiología , Adulto , Anciano , Fibrilación Atrial/epidemiología , Estudios de Cohortes , Comorbilidad , Enfermedad de la Arteria Coronaria/epidemiología , Diabetes Mellitus/epidemiología , Prueba de Esfuerzo , Femenino , Humanos , Hipertensión/epidemiología , Incidencia , Masculino , Equivalente Metabólico , Michigan/epidemiología , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Obesidad/epidemiología , Prevalencia , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Conducta Sedentaria
4.
Echocardiography ; 33(7): 1085-1088, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27009593

RESUMEN

Myocardial abscess is an extremely rare entity and is often deadly in nature. We present a case of a patient with recent orthotopic liver transplant, on immunosuppression, who presented with cardiac tamponade due to Aspergillus fumigatus pericarditis and associated myocardial abscess. The diagnosis was made based on computed tomography imaging, culture of pericardial fluid for Aspergillus, and transthoracic echocardiography. The patient received antifungal therapy with clinical improvement and documented reduction in abscess size based on repeat echocardiogram. Aspergillus myocardial abscess is an extremely rare diagnosis but should be considered in an immunosuppressed patient presenting with pericardial effusion or ventricular mass.

5.
Echocardiography ; 33(2): 186-92, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26460068

RESUMEN

OBJECTIVE: Cardiac angiosarcoma is the most common primary malignant cardiac tumor. The dismal prognosis and nonspecific symptomatology underscore the need for an accurate and cost-effective approach to the identification and characterization of this rare tumor. METHODS: Mayo Clinic tissue registry archives were queried for all histologically confirmed cases of cardiac angiosarcoma (1976-2013) with available imaging data. Echocardiograms were retrospectively reviewed. RESULTS: Thirty-three cases of cardiac angiosarcoma were identified; of these, 17 had echocardiograms available (mean age, 46 years; six men). Transthoracic echocardiography (TTE) as the initial diagnostic test had 75% sensitivity for visualizing primary cardiac angiosarcoma (9/12 patients). Tumor extension into the pericardium was common and pericardial effusion was present in 15 patients (88%); however, pericardial fluid cytology was negative for malignancy in all tested patients (n = 15). Left ventricular ejection fraction (LVEF) was preserved in 16 patients (94%) (average LVEF, 62%). Right ventricular function was mildly reduced in two patients (12%) at initial presentation. Tricuspid valve obstruction was present in three patients (18%; mean diastolic gradient, 6.3 mmHg [range, 3-11 mmHg]). CONCLUSION: The sensitivity of TTE as the first diagnostic imaging modality compared favorably with computed tomography. Pericardial effusion was common, but pericardial fluid cytology was negative in all patients who underwent pericardiocentesis. The absence of a stalk was a universal finding that may help distinguish angiosarcoma from benign, primarily pedunculated tumors such as myxoma and papillary fibroelastoma.


Asunto(s)
Neoplasias Cardíacas/diagnóstico por imagen , Hemangiosarcoma/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros/estadística & datos numéricos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
6.
Radiol Cardiothorac Imaging ; 3(2): e200446, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33969306

RESUMEN

PURPOSE: To compare invasive right heart catheterization with four-dimensional (4D) flow MRI for estimating shunt fraction in patients with intracardiac and extracardiac shunts. MATERIALS AND METHODS: In this retrospective study, patients who underwent 4D flow MRI and invasive right heart catheterization with a shunt run between August 2015 and November 2018 were included. The primary objective was comparison of estimated shunt fraction (ratio of pulmonary-to-systemic flow, Qp/Qs) at 4D flow and catheterization. Secondary objectives included comparison of the right ventricular-to-left ventricular stroke volume ratio (RVSV/LVSV) to shunt fraction (for those with applicable shunts) and comparison of cardiac output between 4D flow and catheterization. Statistical analysis included Pearson correlation and Bland-Altman plots. RESULTS: A total of 33 patients met inclusion criteria (mean age, 49 years ± 16 [standard deviation]; 24 women). 4D flow measurements of Qp/Qs strongly correlated with those at catheterization (r = 0.938), and there was no bias. RVSV/LVSV correlated strongly with Qp/Qs from 4D flow (r = 0.852) and catheterization (r = 0.842). Measurements of left ventricle (Qs) and right ventricle (QP) cardiac output from 4D flow and catheterization (Fick) correlated moderately overall (r = 0.673 [Qp] and r = 0.750 [Qs]). CONCLUSION: Shunt fraction measurement using 4D flow MRI compares well with that using invasive cardiac catheterization.Supplemental material is available for this article.© RSNA, 2021.

8.
Transl Res ; 209: 138-155, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30986384

RESUMEN

The inappropriate deposition of extracellular matrix within the heart (termed cardiac fibrosis) is associated with nearly all types of heart disease, including ischemic, hypertensive, diabetic, and valvular. This alteration in the composition of the myocardium can physically limit cardiomyocyte contractility and relaxation, impede electrical conductivity, and hamper regional nutrient diffusion. Fibrosis can be grossly divided into 2 types, namely reparative (where collagen deposition replaces damaged myocardium) and reactive (where typically diffuse collagen deposition occurs without myocardial damage). Despite the widespread association of fibrosis with heart disease and general understanding of its negative impact on heart physiology, it is still not clear when collagen deposition becomes pathologic and translates into disease symptoms. In this review, we have summarized the current knowledge of cardiac fibrosis in human patients and experimental animal models, discussing the mechanisms that have been deduced from the latter in relation to the former. Because assessment of the extent of fibrosis is paramount both as a research tool to further understanding and as a clinical tool to assess patients, we have also summarized the current state of noninvasive/minimally invasive detection systems for cardiac fibrosis. Albeit not exhaustive, our aim is to provide an overview of the current understanding of cardiac fibrosis, both clinically and experimentally.


Asunto(s)
Colágeno/metabolismo , Modelos Animales de Enfermedad , Cardiopatías/metabolismo , Cardiopatías/patología , Miocardio/metabolismo , Animales , Biomarcadores/metabolismo , Fibrosis , Humanos
9.
Heart ; 104(22): 1887-1890, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30093546

RESUMEN

CLINICAL INTRODUCTION: An 82-year-old man with a history of coronary artery bypass surgery, hypertension and small bowel gastrointestinal stromal tumour underwent cardiac risk evaluation prior to surgical resection of his tumour. He was asymptomatic from a cardiovascular perspective, but his activity level was less than four metabolic equivalents. Physical examination was notable for a 2/6 systolic murmur at the apex. ECG showed sinus rhythm. A transthoracic echocardiogram was performed (figure 1 and online supplementary video 1).DC1SP110.1136/heartjnl-2018-313413.supp1Supplementary file 1 heartjnl;104/22/1887/F1F1F1Figure 1Transthoracic echocardiography. (A) Mitral valve continuous wave Doppler and (B) tricuspid valve continuous wave Doppler. QUESTION: The findings in figure 1 are most likely due to which of the following?Atrioventricular conduction block.Acute severe aortic regurgitation.Patent ductus arteriosus.Atrial flutter.Severe mitral stenosis.


Asunto(s)
Bloqueo Atrioventricular/diagnóstico por imagen , Ecocardiografía Doppler en Color , Soplos Sistólicos , Anciano de 80 o más Años , Bloqueo Atrioventricular/fisiopatología , Electrocardiografía , Frecuencia Cardíaca , Humanos , Masculino , Valor Predictivo de las Pruebas
10.
JACC Cardiovasc Interv ; 9(22): 2329-2340, 2016 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-27884358

RESUMEN

OBJECTIVES: The aim of this study was to examine the impact of 3-dimensional (3D) computed tomographic (CT) guided procedural planning for left atrial appendage (LAA) occlusion on the early operator WATCHMAN learning curve. BACKGROUND: Traditional WATCHMAN implantation is dependent on 2-dimensional transesophageal echocardiographic (TEE) sizing and intraprocedural guidance. METHODS: LAA occlusion with the WATCHMAN device was performed in 53 patients. Pre-procedural case plans were generated from CT studies with recommended device size, catheter selection, and C-arm angle for deployment. RESULTS: All 53 patients underwent successful LAA occlusion with the WATCHMAN. Three-dimensional CT LAA maximal-width sizing was 2.7 ± 2.2 mm and 2.3 ± 3.0 mm larger than 2-dimensional and 3D TEE measurements, respectively (p ≤ 0.0001). By CT imaging, device selection was 100% accurate. There were 4 peri-WATCHMAN leaks (<4.5 mm) secondary to accessory LAA pedunculations. By 2-dimensional TEE maximal-width measurements alone, 62.3% (33 of 53) would have required larger devices. Using 3D TEE maximal-width measurements, 52.8% of cases (28 of 53) would have required larger devices. Three-dimensional TEE length would have inappropriately excluded 10 patients from WATCHMAN implantation. Compared with the average of 1.8 devices used per implantation attempt in PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) (82% success rate), the present site averaged 1.245 devices per implantation attempt (100% success rate). There were no intraprocedural screen failures and no major adverse cardiac events. CONCLUSIONS: Three-dimensional CT image case planning provides a comprehensive and customized patient-specific LAA assessment that appears to be accurate and may possibly facilitate reducing the early WATCHMAN implantation learning curve.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Cateterismo Cardíaco/instrumentación , Competencia Clínica , Imagenología Tridimensional , Curva de Aprendizaje , Interpretación de Imagen Radiográfica Asistida por Computador , Dispositivo Oclusor Septal , Terapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Michigan , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA