Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int Heart J ; 65(1): 21-28, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38296575

RESUMEN

Although guidelines recommend early aspirin administration after diagnosis of ST-elevation myocardial infarction (STEMI), the decision of pretransfer aspirin administration is at the discretion of the primary physicians. Therefore, this study aimed to determine whether pretransfer aspirin administration was associated with better angiographical outcomes in patients with STEMI. This study compared the angiographic findings of thrombolysis in myocardial infarction (TIMI) flow grade in the infarct-related artery before percutaneous coronary intervention (PCI) between patients who received pretransfer aspirin and those who did not. In total, 28 patients (11.2%) were administered aspirin before transfer and 219 (88.8%) were administered aspirin upon arrival at the hospital. Propensity score matching yielded 135 patients [27 patients (20%) who were administered aspirin before transfer and 108 patients (80%) who were administered aspirin upon arrival at the hospital]. Patients who received pretransfer aspirin had a higher rate of TIMI-3 flow before PCI compared to those who did not receive pretransfer aspirin [8 (28.6%) versus 15 (6.8%), P < 0.01, in all study patients; 8 (26.6%) versus 7 (6.5%), P < 0.01, in propensity-score-matched patients]. Multivariable logistic regression analysis revealed that pretransfer aspirin administration was significantly associated with the presence of TIMI-3 flow before PCI, independent of age, gender, transfer time, and statin use (OR: 5.43, 95% CI: 1.94-15.2, P < 0.01, in all study patients; OR: 6.17, 95% CI: 1.86-20.46, P < 0.01, in propensity-score-matched patients). Pretransfer aspirin administration could lead to the early restoration of coronary blood flow in patients with STEMI, supporting its active use in STEMI care.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/etiología , Aspirina/uso terapéutico , Intervención Coronaria Percutánea/efectos adversos , Angiografía Coronaria , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 34(2): 315-324, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36511472

RESUMEN

INTRODUCTION: Visually-guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi-automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi-automated (SA) VGLA to that of manual (MN) VGLA. METHODS: Acute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13-18 W), MN (n = 3, 8.5-12 W), or radiofrequency (RF, n = 3, 25-40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation. RESULTS: Acute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 ± 5.9, 33.7 ± 10.0, and 28.0 ± 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 ± 17.4% vs.91.9 ± 25.9%), and circumferentiality (95.8 ± 6.6% vs. 94.8 ± 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 ± 12.7 vs. 21.8 ± 3.8 min, p = .046 and 4.8 ± 3.83 vs. 35.4 ± 4.4, p < .001). CONCLUSION: Motor-assisted semi-automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Terapia por Láser , Venas Pulmonares , Porcinos , Animales , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Terapia por Láser/efectos adversos
3.
Circ J ; 87(2): 296-305, 2023 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-36261336

RESUMEN

BACKGROUND: The predictive value of both atrial natriuretic peptide (ANP) and B-type natriuretic peptide (BNP) is well known. This study evaluated the prognostic value of a novel natriuretic peptide index (NPI) combining ANP and BNP. Methods and Results: This study included 849 consecutive patients with coronary artery disease who underwent successful percutaneous coronary intervention (PCI). Patients were followed up clinically for up to 3 years or until the occurrence of major adverse cardiac events (MACE). The primary endpoint was a composite of all-cause death and non-fatal myocardial infarction. The NPI (pg/mL) was defined as √ANP×BNP. MACE occurred in 73 patients (8.6%) during the follow-up period. Receiver operating characteristic curve analysis showed the highest area under the curve for NPI (0.779) compared with ANP and BNP (0.773 and 0.755, respectively). A risk analysis of MACE occurrence adjusted for the multivariable model showed the highest hazard ratio (HR) for NPI (1.33; 95% confidence interval [CI] 1.18-1.51; P<0.001) compared with ANP and BNP (HR 1.25 [95% CI 1.13-1.39] and 1.30 [95% CI 1.13-1.49], respectively; P<0.001). The NPI was a significant independent predictor of MACE, among other clinical parameters, in the multivariable analysis. CONCLUSIONS: Compared with ANP and BNP, the NPI was more effective in predicting future adverse events after PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Biomarcadores , Enfermedad de la Arteria Coronaria/cirugía , Péptido Natriurético Encefálico , Valor Predictivo de las Pruebas , Pronóstico , Vasodilatadores
4.
Europace ; 23(11): 1757-1766, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-34151947

RESUMEN

AIMS: We studied the extent/area of electrical pulmonary vein isolation (PVI) after either pulsed field ablation (PFA) using a pentaspline catheter or thermal ablation technologies. METHODS AND RESULTS: In a clinical trial (NCT03714178), paroxysmal atrial fibrillation (PAF) patients underwent PVI with a multi-electrode pentaspline PFA catheter using a biphasic waveform, and after 75 days, detailed voltage maps were created during protocol-specified remapping studies. Comparative voltage mapping data were retrospectively collected from consecutive PAF patients who (i) underwent PVI using thermal energy, (ii) underwent reablation for recurrence, and (iii) had durably isolated PVs. The left and right PV antral isolation areas and non-ablated posterior wall were quantified. There were 20 patients with durable PVI in the PFA cohort, and 39 in the thermal ablation cohort [29 radiofrequency ablation (RFA), 6 cryoballoon, and 4 visually guided laser balloon]. Pulsed field ablation patients were younger with shorter follow-up. Left atrial diameter and ventricular systolic function were preserved in both cohorts. There was no significant difference between the PFA and thermal ablation cohorts in either the left- and right-sided PV isolation areas, or the non-ablated posterior wall area. The right superior PV isolation area was smaller with PFA than RFA, but this disappeared after propensity score matching. Notch-like normal voltage areas were seen at the posterior aspect of the carina in the balloon sub-cohort, but not the PFA or RFA cohorts. CONCLUSION: Catheter-based PVI with the pentaspline PFA catheter creates chronic PV antral isolation areas as encompassing as thermal energy ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía , Humanos , Terapia por Láser , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 31(6): 1323-1331, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32250501

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) using standard radiofrequency (RF) catheters is limited by incomplete contiguity and prolonged procedural times. A novel, 9-mm lattice-tip irrigated RF catheter can create wide lesions rapidly in swine atria. METHODS: In five swine, temperature limited (75°C) irrigated RF for 5 seconds/ablation was selected, to isolate seven pulmonary veins (PVs; five right superior and two inferior commons) and create five right atrial lines. After 4 weeks, repeat mapping and additional ablation to create atrial isthmus lesions were performed. The chronic lesions were submitted for histology. This was compared with right superior PVI data using standard 3.5-mm irrigated tip ablation in six swine. RESULTS: All targeted PVs (seven of seven, 100%) were acutely isolated. Durable isolation was observed in all six of six PVs treated with 5-second applications, but not in one PV inadvertently treated with 4-second applications. For the durably isolated PVs, the mean lesion count/PV and total RF time/PV was 16.3 ± 5.2 applications and 81.3 ± 25.9 seconds for the right superior and 14.5 ± 0.7 applications and 71.1 ± 5.5 seconds for the inferior common PV. Right atrial linear ablation was performed with a lesion count of 12 ± 2.3 applications and RF times of 59.5 ± 12.5 seconds. Cavotricuspid and mitral isthmus linear ablations were transmural along their entire length. All 53 of 53 (100%) sections were transmural on histology. CONCLUSION: Rapid and durable PVI and linear atrial ablation is feasible with this novel 9-mm lattice-tip catheter.


Asunto(s)
Catéteres Cardíacos , Ablación por Catéter/instrumentación , Venas Pulmonares/cirugía , Irrigación Terapéutica/instrumentación , Potenciales de Acción , Animales , Ablación por Catéter/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Frecuencia Cardíaca , Tempo Operativo , Venas Pulmonares/patología , Venas Pulmonares/fisiopatología , Reoperación , Sus scrofa , Irrigación Terapéutica/efectos adversos , Factores de Tiempo
6.
Catheter Cardiovasc Interv ; 95(5): 906-910, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31364807

RESUMEN

OBJECTIVES: This study aimed to validate the clinical implications of audiovisual telesupport system use. BACKGROUND: An audiovisual telesupport system with supervisors has been effective in guiding procedures when surgeons have limited experience with the technique. However, cardiovascular catheter interventions using an audiovisual telesupport system has not been previously reported. METHODS: Starting in September 2017, two cardiologists in Kamisu Saiseikai Hospital (Kamisu, Japan, with limited cardiologists) began performing cardiovascular catheter interventions using an audiovisual telesupport system. This system enabled them to perform catheter interventions with the support of advisors in the University of Tsukuba (Tsukuba, Japan). We retrospectively assessed procedure time and complications of percutaneous coronary intervention (PCI) and catheter ablation (CA). RESULTS: In the first 10 months, 21 patients with coronary artery disease underwent PCI using this system. The mean procedure duration of PCI was 42 ± 10 min. Nine patients with tachyarrhythmia including supraventricular tachycardia (SVT), ventricular premature contraction (VPC), common atrial flutter, and paroxysmal atrial fibrillation (AF) underwent CA using this system. The mean CA procedure time was 134 ± 31 min for SVT, 100 ± 14 min for VPC, and 200 min for AF. All PCI and CA procedures were successfully performed without any complications. CONCLUSIONS: The audiovisual telesupport system enabled cardiologists with limited human resources to provide safe and high-quality catheter interventions.


Asunto(s)
Arritmias Cardíacas/cirugía , Recursos Audiovisuales , Cardiólogos/educación , Ablación por Catéter , Instrucción por Computador , Enfermedad de la Arteria Coronaria/terapia , Educación de Postgrado en Medicina , Intervención Coronaria Percutánea/educación , Consulta Remota/instrumentación , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Ablación por Catéter/efectos adversos , Competencia Clínica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Tempo Operativo , Intervención Coronaria Percutánea/efectos adversos , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Europace ; 22(3): 434-439, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31876913

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel, non-thermal modality that selectively ablates myocardium with ultra-short electrical impulses while sparing collateral tissues. In a proof-of-concept study, the safety and feasibility of ventricular PFA were assessed using a prototype steerable, endocardial catheter. METHODS AND RESULTS: Under general anaesthesia, the left and right ventricles of four healthy swine were ablated using the 12-Fr deflectable PFA catheter and a deflectable sheath guided by electroanatomic mapping. Using the study catheter, electrograms were recorded for each site and pre-ablation and post-ablation pacing thresholds (at 2.0 ms pulse width) were recorded in two of four animals. After euthanasia at 35.5 days, the hearts were submitted for histology. The PFA applications (n = 39) resulted in significant electrogram reduction without ventricular arrhythmias. In ablation sites where it was measured, the pacing thresholds increased by >16.8 mA in the right ventricle (3 sites) and >16.1 mA in the left ventricle (7 sites), with non-capture at maximum amplitude (20 mA) observable in 8 of 10 sites. Gross measurements, available for 28 of 30 ablation sites, revealed average lesion dimensions to be 6.5 ± 1.7 mm deep by 22.6 ± 4.1 mm wide, with a maximum depth and width of 9.4 mm and 28.6 mm, respectively. In the PFA lesions, fibrous tissue homogeneously replaced myocytes with a narrow zone of surrounding myocytolysis and no overlying thrombus. When present, nerve fascicles and vasculature were preserved within surrounding fibrosis. CONCLUSION: We demonstrate that endocardial PFA can be focally delivered using this prototype catheter to create homogeneous, myocardium-specific lesions.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Animales , Arritmias Cardíacas , Endocardio , Ventrículos Cardíacos/cirugía , Miocardio , Porcinos , Taquicardia Ventricular/cirugía
10.
J Electrocardiol ; 51(2): 338-342, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29103619

RESUMEN

A 71-year-old woman with narrow QRS tachycardia was referred for catheter ablation. The clinical tachycardia was diagnosed as slow/fast form of atrioventricular (AV) nodal reentrant tachycardia (AVNRT) with the upper common pathway. Although neither conventional nor double atrial programmed extrastimulation (APS) showed any evidence of a dual AV nodal pathway, AV simultaneous pacing during basic stimulation preceding APS (AVSP-APS) reproducibly revealed a dual AV nodal pathway as a double ventricular response. The AVSP-APS pacing method may be helpful to unmask a "concealed slow pathway" in patients with AVNRT.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Anciano , Diagnóstico Diferencial , Electrocardiografía , Femenino , Humanos
11.
J Cardiovasc Electrophysiol ; 28(3): 327-335, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27925329

RESUMEN

INTRODUCTION: A fragmented QRS (fQRS) is reported to be associated with a poor prognosis or sudden cardiac death (SCD) in patients with Brugada syndrome or ischemic heart disease. However, no studies have clarified the impact of the presence of an fQRS on SCD or ventricular arrhythmic events in patients receiving cardiac resynchronization therapy (CRT). This study aimed to clarify this point in patients with nonischemic cardiomyopathy. METHODS AND RESULTS: This study included 137 heart failure patients with nonischemic cardiomyopathy who received CRT (NYHA functional class: II/III/IV = 25/84/28). The 12-lead ECGs before and after CRT were analyzed. The presence of an fQRS was decided in accordance with the definition in previous papers. Before the CRT, an fQRS was observed in 67 patients (fQRS-pre; 49%). However, it was masked in 35 (52% of fQRS-pre) patients after the CRT. Inversely, in 70 patients in whom an fQRS was absent before the CRT, it appeared after the CRT in 15 (21%) patients. As a result, 47 patients (34%) had an fQRS after the CRT (fQRS-post), and it was less than that before the CRT (P = 0.014). During 18 months of follow-up, SCD or ventricular arrhythmic events were observed more frequently in patients with an fQRS-post than in those without (36.2% vs. 3.3%, P < 0.001). A Cox regression analysis revealed that an fQRS-post was significantly associated with those events (hazard ratio = 9.18; 95% confidence interval = 2.45-34.48, P = 0.001). CONCLUSION: In patients with nonischemic cardiomyopathy who received CRT, an fQRS-post was independently associated with SCD or ventricular arrhythmic events.


Asunto(s)
Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Cardiomiopatías/complicaciones , Muerte Súbita Cardíaca/prevención & control , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Potenciales de Acción , Adulto , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/mortalidad , Cardiomiopatías/fisiopatología , Distribución de Chi-Cuadrado , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
Circ J ; 81(12): 1807-1815, 2017 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-28652528

RESUMEN

BACKGROUND: Idiopathic ventricular arrhythmias (VAs) rarely arise from the epicardium at the crux of the heart. However, the electrophysiological characteristics of VAs successfully ablated from the ostium of the coronary sinus (CSO) have not yet been documented.Methods and Results:Electrocardiographic and electrophysiological data were analyzed in patients with idiopathic VAs successfully ablated from the CSO.Among 309 patients with idiopathic VAs treated with radiofrequency catheter ablation (RFCA), 6 (1.94%; 3 men; age: 66.3±9.7 years) had VAs successfully ablated from the CSO. Only 1 patient had sustained ventricular tachycardia. The morphology of the QRS showed a left superior axis and QS pattern in leads III and aVF. Furthermore, the precordial maximum deflection index was >0.55 in all patients and a right bundle branch block pattern was recorded in 5 of 6 patients. All VAs were successfully eliminated by RFCA within the CSO. Intracardiac ECGs at sites where VAs were eliminated by RFCA showed clear atrial and ventricular potentials (atrial amplitude: 0.21±0.11 mV; ventricular amplitude: 0.43±0.24 mV), except in 1 case of atrial fibrillation. No patients had recurrence during the 3.4±1.8-year follow-up period. CONCLUSIONS: The idiopathic VAs in our study were eliminated by RFCA within the CS, where a clear atrial amplitude was recorded.


Asunto(s)
Ablación por Catéter/métodos , Seno Coronario/fisiopatología , Fenómenos Electrofisiológicos , Taquicardia Ventricular/terapia , Anciano , Bloqueo de Rama/fisiopatología , Electrocardiografía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
13.
Circ J ; 81(11): 1603-1610, 2017 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-28579601

RESUMEN

BACKGROUND: Several reports have demonstrated the importance of severely low voltage areas as arrhythmogenic substrates of ventricular tachycardia (VT). However, a comparative study of dense scar-targeted and infarcted border zone-targeted strategies has not been reported.Methods and Results:We divided 109 consecutive patients with VT post-infarction from 6 centers into 2 groups according to the ablation strategy used: dense scar-targeted ablation (DS ablation, 48%) or border zone-targeted ablation (BZ ablation, 52%). During DS ablation, we attempted to identify VT isthmuses in the dense scar areas (≤0.6 mV) using detailed pace mapping, and linear ablation lesions were applied mainly to those areas. During BZ ablation, linear ablation of standard low voltage areas (0.5-1.5 mV) was performed along with good pace map sites of the clinical VT. Acute success was defined as complete success (no VTs inducible) or partial success (clinical VT was noninducible). The acute complete success rate was significantly higher for DS ablation than for BZ ablation (62% vs. 42%, P=0.043). During a median follow-up of 37 months, the VT-free survival rate was significantly higher for DS ablation than for BZ ablation (80% vs. 58% at 48 months; log-rank P=0.038). CONCLUSIONS: DS ablation may be a more effective therapy for post-infarction VT than BZ ablation in terms of the acute complete success rate and long-term follow-up.


Asunto(s)
Ablación por Catéter/métodos , Infarto del Miocardio/patología , Taquicardia Ventricular/cirugía , Anciano , Ablación por Catéter/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Tasa de Supervivencia , Resultado del Tratamiento
14.
J Cardiovasc Electrophysiol ; 27(12): 1448-1453, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27593399

RESUMEN

INTRODUCTION: Recent studies showed that J waves were associated with higher incidence of ventricular tachyarrhythmia (VT/VF) in patients with idiopathic ventricular fibrillation (VF) and myocardial infarction. We sought to assess the association between J waves and VT/VF in patients with nonischemic cardiomyopathy (NICM). METHODS AND RESULTS: We retrospectively enrolled 109 patients (79 men; mean age, 60 ± 15 years) with NICM who underwent implantable cardioverter defibrillator (ICD) implantation. The primary endpoint of this study was the occurrence of appropriate device therapy due to sustained VT/VF. The J wave was electrocardiographically defined as an elevation of the terminal portion of the QRS complex of >0.1 mV in at least 2 contiguous inferior or lateral leads. Among the 109 patients, 37 (34%) experienced an episode of appropriate device therapy during a median follow-up period of 25.9 (IQR 11.5-54.3) months. Kaplan-Meier curves showed that the presence of J waves on the 12-lead ECG obtained before device implantation was associated with an increased occurrence of appropriate device therapy (P < 0.001). Multivariate Cox proportional regression analysis revealed that the presence of J waves (HR 2.95; 95% CI 1.31-6.64; P = 0.009) was an independent predictor for the occurrence of appropriate device therapy. In the subgroup analysis of the patients with dilated or hypertrophic cardiomyopathy, J wave tended to increase the occurrence of appropriate device therapy (P = 0.056 and P = 0.092, respectively). CONCLUSIONS: The presence of J waves was an independent predictor for the occurrence of appropriate device therapy in patients with NICM who underwent ICD implantation.


Asunto(s)
Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Hipertrófica/complicaciones , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular/etiología , Fibrilación Ventricular/etiología , Potenciales de Acción , Anciano , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Dilatada/terapia , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/fisiopatología , Cardiomiopatía Hipertrófica/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia
15.
Europace ; 17(7): 1107-16, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25564550

RESUMEN

AIMS: There are many reports on the ECG characteristics of idiopathic outflow tract ventricular arrhythmias (OT-VAs) to predict their origin. However, differentiating near regions using 12-lead ECGs is still complicated. The synthesized 18-lead ECG derived from the 12-lead ECG can provide virtual waveforms of the right-sided chest leads (V3R, V4R, and V5R) and back leads (V7, V8, and V9). The aim of this study was to develop a simple and useful parameter for differentiating OT-VA origins using the 18-lead ECG. METHODS AND RESULTS: We studied 28 and 73 patients with idiopathic VAs in a pacemapping study and validation cohort, respectively. In the pacemapping study, several sites out of five different sites were paced in each patient: the anterior and posterior right ventricular OT (RVOT-ant and RVOT-post), right and left coronary cusps (RCC and LCC), and junction of both cusps (RLJ). The 18-lead ECGs during pacemapping among the five sites were compared for establishing a simple parameter to predict VA origins. A novel parameter using 18-lead ECGs was tested prospectively in 73 patients. In the pacemapping study, the dominant QRS morphology pattern in the synthesized V5R significantly differed among those sites (RVOT-ant:Rs, RVOT-post:rS, RCC:QS, RLJ:qR, and LCC:R). The patients in the validation cohort were divided into five groups depending on those QRS morphology patterns during VAs in the synthesized V5R. Each V5R QRS morphology pattern could predict a precise origin of the OT-VAs with an overall accuracy of 75%. CONCLUSION: The QRS morphology pattern in V5R was a simple and useful parameter for differentiating detailed OT-VA origins.


Asunto(s)
Algoritmos , Mapeo del Potencial de Superficie Corporal/métodos , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Adolescente , Adulto , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
17.
Heart Vessels ; 30(3): 416-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24687560

RESUMEN

Radiofrequency catheter ablation of an atrial tachycardia (AT) and atrial fibrillation (AF) was performed in a patient with a history of pulmonary vein isolation for paroxysmal AF. The AT exhibited a centrifugal pattern with the posterolateral LA as the earliest activation site. The AT was not terminated by ablation at the endocardial earliest site, but its cycle length was prolonged by ablation at an opposite site within the Vein of Marshall. Finally, the AT was terminated by an energy application at a site 7 mm posteroinferior to the initial earliest activation site. We analyzed the local potentials of each energy delivery site in detail.


Asunto(s)
Ablación por Catéter/métodos , Endocardio/cirugía , Sistema de Conducción Cardíaco/cirugía , Pericardio/cirugía , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Angiografía Coronaria , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Endocardio/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Pericardio/fisiopatología , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento
18.
Circ J ; 78(4): 859-64, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24531743

RESUMEN

BACKGROUND: Linear ablation of atrial flutter usually targets a 6 o'clock position on the cavotricuspid isthmus on left anterior oblique view, but the difficulty of the ablation often requires a variation in successful ablation line position from 5 to 7 o'clock. METHODS AND RESULTS: This study included 94 patients without structural heart disease. A linear lesion was created in turn at the 6, 7, and 5 o'clock positions until bidirectional block of the isthmus was completed; the final lesion was defined as the successful ablation line. The degree of counterclockwise heart rotation (CCW-HR) was evaluated in a blinded fashion according to the angle between the vertical line crossing the His bundle catheter and the line connecting the His bundle catheter and coronary sinus ostium. Successful ablation lines were obtained at the 6 o'clock position in 59 patients (63%); the 7 o'clock position in 19 patients (20%; the oldest group with a moderate radiofrequency burden); and the 5 o'clock position in the remaining 16 (17%; the youngest group with the largest radiofrequency burden). Age-related increase in CCW-HR was the only independent predictor of a more septal successful ablation line (OR, 7.1; 95% CI: 3.3-14.3; P<0.01). CONCLUSIONS: Variation in successful ablation line position was affected by age-related CCW-HR; its evaluation might reduce radiofrequency burden, especially in the young and elderly.


Asunto(s)
Aleteo Atrial , Fascículo Atrioventricular , Ablación por Catéter/métodos , Adulto , Anciano , Aleteo Atrial/patología , Aleteo Atrial/fisiopatología , Aleteo Atrial/cirugía , Fascículo Atrioventricular/patología , Fascículo Atrioventricular/fisiopatología , Fascículo Atrioventricular/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Heart Vessels ; 29(4): 464-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23801459

RESUMEN

The purpose of this study was to find a safe dosing regimen for landiolol, an ultra-short-acting ß-adrenergic blocking agent, to rapidly control supraventricular tachyarrhythmias (SVTs) in patients with heart failure (HF). Landiolol is reported to have good effects in the treatment of SVTs after cardiac surgery. We evaluated 52 patients with SVT and symptoms of HF (NYHA class III/IV, 10/42; EF 32 ± 12 %) on admission because of ischaemic disease (n = 10), non-ischaemic cardiomyopathy (n = 32), or valvular disease (n = 10). Paroxysmal/persistent atrial fibrillation and atrial tachycardia were present in 16 (30 %), 23 (45 %), and 13 (25 %) patients, respectively. The patients first underwent conventional therapy with carperitide, dobutamine, or milrinone. Intravenous landiolol was administered at an infusion rate of 1 µg/kg/min and, if no adverse effects developed, the maintenance dose, titrated to HR and blood pressure response, was increased. At an average dose of 10.8 ± 9.4 µg/kg/min, mean HR significantly decreased significantly from 133 ± 27 to 82 ± 15 beats/min (P < 0.01), whereas systolic blood pressure did not differ from baseline to attainment of an effective dose level (105 ± 21 vs. 101 ± 19 mmHg, P = ns). Within 60 min after initiation of therapy, all patients had achieved a 20 % reduction in HR at the maintenance dose. Transient asymptomatic hypotension requiring cessation of landiolol therapy occurred in three patients. Intravenous administration of landiolol was both effective in rapidly controlling HR for up to 24 h and useful as bridging treatment to additional therapy of oral ß blockade, pulmonary vein catheter ablation, or cardiac resynchronisation therapy in patients with HF.


Asunto(s)
Antagonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Insuficiencia Cardíaca/tratamiento farmacológico , Frecuencia Cardíaca/efectos de los fármacos , Morfolinas/administración & dosificación , Taquicardia Supraventricular/tratamiento farmacológico , Urea/análogos & derivados , Antagonistas de Receptores Adrenérgicos beta 1/efectos adversos , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Presión Sanguínea/efectos de los fármacos , Esquema de Medicación , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Infusiones Intravenosas , Japón , Masculino , Persona de Mediana Edad , Morfolinas/efectos adversos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Urea/administración & dosificación , Urea/efectos adversos
20.
Front Neurol ; 15: 1368890, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39170075

RESUMEN

Background and purpose: Despite the ongoing advancements in mechanical thrombectomy for large vessel occlusions causing acute ischemic stroke, successful recanalization is not achieved in all patients. One contributing factor is the presence of fibrin-rich hard clots. We proposed a new technique called the PREMIER technique, which aims to retrieve fibrin-rich clots. This study evaluated the efficacy of the PREMIER technique on fibrin-rich and erythrocyte-rich clots by comparing it with the simple use of EmboTrap III in an in vitro vessel model. Methods: The PREMIER technique involves partially resheathing a fully deployed EmboTrap III (CERENOVUS, Johnson & Johnson Medical Devices, Irvine, California, USA) using a microcatheter to capture and retrieve a hard clot between the inner channel and outer cages of EmboTrap III. We compared recanalization rate of the PREMIER technique with the simple use of EmboTrap III in an in vitro vessel model, occluding the M1 segment with fibrin-rich hard clots (0% erythrocyte composition) and erythrocyte-rich clots (50% erythrocyte composition). Results: Among the 40 procedures (10 each for the PREMIER technique and the simple use of EmboTrap III for two different clots) for fibrin-rich clots, the PREMIER technique achieved successful recanalization in all 10 cases, with a significantly higher recanalization rate than the EmboTrap III (100% vs. 50%, p = 0.03). For erythrocyte-rich clots, the recanalization rate was not significantly different in the PREMIER technique compared with the simple use of EmboTrap III (80% vs. 70%, p = 1.00). Conclusion: The PREMIER technique is a novel technique for acute large-vessel occlusions caused by fibrin-rich hard clots that hinders successful recanalization during mechanical thrombectomy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA