Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Pediatr ; 204: 157-161, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30268396

RESUMEN

OBJECTIVE: To assess sound levels of 4 high-frequency neonatal ventilators to determine whether there is a safety benefit in using modern high-frequency ventilators compared with older models. STUDY DESIGN: We performed a bench study comparing noise production of the Sensormedics 3100A Oscillator, Bunnell Life Pulse Jet Ventilators Model 203 and Model 204, and Dräger VN500 in high-frequency mode. A wide range of ventilation settings was examined. All measurements were performed in triplicate using a high-fidelity sound meter, with data analyzed using ANOVA and regression analyses. RESULTS: The Dräger ventilator was quietest overall, with average sound levels of 49.8 ± 0.49 dB across all settings. The average noise from the Sensormedics was 53.6 ± 2.01 dB, for Bunnell Model 203 was 54.1 ± 1.09 dB, and for Bunnell Model 204 was 53.7 ± 1.45 dB. Adjustments made to frequency/rate and mean airway pressure/positive end-expiratory pressure had minimal effect on noise, and increasing amplitude/peak inspiratory pressure resulted in significantly more noise by all ventilators. At all settings, the Sensormedics and Bunnell ventilators were louder than the Dräger, and the difference became greater as amplitude/peak inspiratory pressure was increased. CONCLUSIONS: The Dräger VN500 in high-frequency mode produces significantly less noise that both the Sensormedics and Bunnell ventilators. These data suggest that using the Dräger VN500 as a high-frequency ventilator may reduce the potential for adverse outcomes created by ventilator noise.


Asunto(s)
Ventilación de Alta Frecuencia/instrumentación , Unidades de Cuidado Intensivo Neonatal/estadística & datos numéricos , Ruido , Ventilación de Alta Frecuencia/efectos adversos , Ventilación de Alta Frecuencia/estadística & datos numéricos , Humanos , Recién Nacido
2.
J Pediatr ; 205: 70-76.e2, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30404739

RESUMEN

OBJECTIVE: To explore the relation between time to reintubation and death or bronchopulmonary dysplasia (BPD) in extremely preterm infants. STUDY DESIGN: This was a subanalysis from an ongoing multicenter observational study. Infants with birth weight ≤1250 g, requiring mechanical ventilation, and undergoing their first elective extubation were prospectively followed throughout hospitalization. Time to reintubation was defined as the time interval between first elective extubation and reintubation. Univariate and multivariate logistic regression analyses were performed to evaluate associations between time to reintubation, using different observation windows after extubation (24-hour intervals), and death/BPD (primary outcome) or BPD among survivors (secondary outcome). aORs were computed with and without the confounding effects of cumulative mechanical ventilation duration. RESULTS: Of 216 infants included for analysis, 103 (48%) were reintubated at least once after their first elective extubation. Reintubation was associated with lower gestational age/weight and greater morbidities compared with infants never reintubated. After adjusting for confounders, reintubation within observation windows ranging between 24 hours and 3 weeks postextubation was associated with increased odds of death/BPD (but not BPD among survivors), independent of the cumulative mechanical ventilation duration. Reintubation within 48 hours from extubation conferred higher risk-adjusted odds of death/BPD vs other observation windows. CONCLUSIONS: Although reintubation after elective extubation was independently associated with increased likelihood of death/BPD in extremely preterm infants, the greatest risk was attributable to reintubation within the first 48 hours postextubation. Prediction models capable of identifying the highest-risk infants may further improve outcomes.


Asunto(s)
Extubación Traqueal/efectos adversos , Displasia Broncopulmonar/etiología , Intubación Intratraqueal/efectos adversos , Respiración Artificial/mortalidad , Extubación Traqueal/estadística & datos numéricos , Displasia Broncopulmonar/mortalidad , Estudios de Casos y Controles , Femenino , Edad Gestacional , Humanos , Lactante , Recien Nacido Extremadamente Prematuro , Recién Nacido , Recién Nacido de muy Bajo Peso , Unidades de Cuidado Intensivo Neonatal , Masculino , Estudios Prospectivos , Respiración Artificial/efectos adversos , Respiración Artificial/métodos , Ajuste de Riesgo , Factores de Tiempo
3.
Pediatr Res ; 83(5): 969-975, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29389921

RESUMEN

BackgroundThe optimal approach for reporting reintubation rates in extremely preterm infants is unknown. This study aims to longitudinally describe patterns of reintubation in this population over a broad range of observation windows following extubation.MethodsTiming and reasons for reintubation following a first planned extubation were collected from infants with birth weight ≤1,250 g. An algorithm was generated to discriminate between reintubations attributable to respiratory and non-respiratory causes. Frequency and cumulative distribution curves were constructed for each category using 24 h intervals. The ability of observation windows to capture respiratory-related reintubations while limiting non-respiratory reasons was assessed using a receiver operating characteristic curve.ResultsOut of 194 infants, 91 (47%) were reintubated during hospitalization; 68% for respiratory and 32% for non-respiratory reasons. Respiratory-related reintubation rates steadily increased from 0 to 14 days post-extubation before reaching a plateau. In contrast, non-respiratory reintubations were negligible in the first post-extubation week, but became predominant after 14 days. An observation window of 7 days captured 77% of respiratory-related reintubations while only including 14% of non-respiratory cases.ConclusionReintubation patterns are highly variable and affected by the reasons for reintubation and observation window used. Ideally, reintubation rates should be reported using a cumulative distribution curve over time.


Asunto(s)
Intubación Intratraqueal/métodos , Intubación Intratraqueal/estadística & datos numéricos , Reconocimiento de Normas Patrones Automatizadas , Extubación Traqueal , Algoritmos , Femenino , Edad Gestacional , Hospitalización , Humanos , Lactante , Recien Nacido Extremadamente Prematuro , Recién Nacido , Estudios Longitudinales , Masculino , Modelos Estadísticos , Estudios Prospectivos , Curva ROC , Respiración Artificial , Factores de Riesgo
4.
Dev Psychobiol ; 53(7): 711-23, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21547899

RESUMEN

We sought to determine if maternal depression, anxiety, and/or treatment with selective serotonin reuptake inhibitors (SSRIs) affect placental human serotonin transporter (SLC6A4), norepinephrine transporter (SLC6A2), and 11ß-hydroxysteroid dehydrogenase type 2 (11ß-HSD2) gene expression. Relative mRNA expression was compared among placental samples (n = 164) from healthy women, women with untreated depression and/or anxiety symptoms during pregnancy, and women who used SSRIs. SLC6A4 expression was significantly increased in placentas from women with untreated mood disorders and from women treated with SSRIs, compared to controls. SLC6A2 and 11ß-HSD2 expression was increased in noncontrol groups, though the differences were not significant. SLC6A4, SLC6A2, and 11ß-HSD2 expression levels were positively correlated. The finding that maternal depression/anxiety affects gene expression of placental SLC6A4 suggests a possible mechanism for the effect(s) of maternal mood on fetal neurodevelopmental programming. SSRI treatment does not further alter the elevated SLC6A4 expression levels observed with exposure to maternal depression or anxiety.


Asunto(s)
11-beta-Hidroxiesteroide Deshidrogenasa de Tipo 2/genética , Ansiedad/genética , Depresión/genética , Proteínas de Transporte de Noradrenalina a través de la Membrana Plasmática/genética , Placenta/metabolismo , Proteínas de Transporte de Serotonina en la Membrana Plasmática/genética , 11-beta-Hidroxiesteroide Deshidrogenasa de Tipo 2/metabolismo , Antidepresivos/uso terapéutico , Ansiedad/metabolismo , Depresión/tratamiento farmacológico , Depresión/metabolismo , Femenino , Desarrollo Fetal/fisiología , Expresión Génica , Humanos , Proteínas de Transporte de Noradrenalina a través de la Membrana Plasmática/metabolismo , Embarazo , Proteínas de Transporte de Serotonina en la Membrana Plasmática/metabolismo
5.
Database (Oxford) ; 2012: bar069, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22323062

RESUMEN

Genome-wide association studies (GWAS) query the entire genome in a hypothesis-free, unbiased manner. Since they have the potential for identifying novel genetic variants, they have become a very popular approach to the investigation of complex diseases. Nonetheless, since the success of the GWAS approach varies widely, the identification of genetic variants for complex diseases remains a difficult problem. We developed a novel bioinformatics approach to identify the nominal genetic variants associated with complex diseases. To test the feasibility of our approach, we developed a web-based aggregation tool to organize the genes, genetic variations and pathways involved in preterm birth. We used semantic data mining to extract all published articles related to preterm birth. All articles were reviewed by a team of curators. Genes identified from public databases and archives of expression arrays were aggregated with genes curated from the literature. Pathway analysis was used to impute genes from pathways identified in the curations. The curated articles and collected genetic information form a unique resource for investigators interested in preterm birth. The Database for Preterm Birth exemplifies an approach that is generalizable to other disorders for which there is evidence of significant genetic contributions.


Asunto(s)
Bases de Datos Genéticas , Nacimiento Prematuro/genética , Adulto , Cromosomas Humanos/genética , Femenino , Genes , Humanos , Recién Nacido , Análisis de Secuencia por Matrices de Oligonucleótidos , Publicaciones Periódicas como Asunto , Transducción de Señal/genética , Flujo de Trabajo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA