RESUMEN
BACKGROUND: After primary percutaneous coronary intervention (PPCI) in patients with acute ST elevation myocardial infarction (STEMI), dual antiplatelet therapy (DAPT) is recommended to continue for 1 year. Occasionally, DAPT interruption may be required due to bleeding issues or unplanned surgical procedures. OBJECTIVE: To systematically evaluate the incidence of DAPT interruption within 1 year after PPCI. METHODS AND RESULTS: This was a single-centre, retrospective registry study. Consecutive patients with STEMI who underwent PPCI from 2013 to 2017 (N=538) were recruited into the analysis. The primary outcome was the incidence of interruption of DAPT within 1 year from the index PPCI. Secondary outcomes included incidence of bleeding in 1 year and prevalence of high bleeding risk (HBR) criteria at index presentation. Within 1 year, 17.1% (84/490) of post-PPCI survivors needed DAPT interruption and 7.1% (35/490) had major bleeding (Bleeding Academic Research Consortium type 3 or 5). At index presentation, HBR criteria were present in 36.1% (194/538) of patients. On univariate analysis, age, female gender, anaemia, anticoagulation, diabetes, hypertension and being a non-smoker were associated with DAPT interruption. On multivariate analysis, age was the only independent factor to predict DAPT interruption. CONCLUSION: DAPT interruption was not uncommon after PPCI in patients with STEMI particularly in the elderly. This has implication on stent selection during PPCI, and further studies are required to investigate which type of stent may best suit our real-life patients with STEMI.
Asunto(s)
Terapia Antiplaquetaria Doble , Hemorragia , Intervención Coronaria Percutánea , Complicaciones Posoperatorias , Infarto del Miocardio con Elevación del ST/cirugía , Terapia Antiplaquetaria Doble/efectos adversos , Terapia Antiplaquetaria Doble/métodos , Femenino , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Hemorragia/terapia , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Selección de Paciente , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Factores de Riesgo , Stents/normas , Procedimientos Quirúrgicos Operativos/efectos adversos , Procedimientos Quirúrgicos Operativos/métodos , Privación de Tratamiento/estadística & datos numéricosRESUMEN
Concomitant chronic kidney disease (CKD) is common in patients with significant valvular heart disease (VHD). This study sought to evaluate the clinical benefit of valvular surgery in patients with concomitant CKD.We evaluated 349 patients with significant VHD who were referred for surgery. Patients were divided into those with CKD stage ≥ 3 (CKD patients; n = 88) and those with CKD stage 1 or 2 (no CKD patients; n = 261). 63 patients did not receive surgery, of which 20 patients had CKD and 43 had no CKD. Mortality and change in eGFR were assessed after a median follow-up of 21 months.In the whole study population, 25% of the patients had CKD and these patients had higher mortality than those with no CKD. The annual mortality rates of patients with CKD who did and did not undergo surgery were 7.9% and 28.0%, respectively. In patients with no CKD, the annual mortality rates of those who did and did not undergo surgery were 1.8% and 2.3%, respectively. Importantly, surgery was associated with significant survival benefit in patients with CKD (log-rank test, P < 0.01), but was neutral in patients with no CKD. Multivariable analysis confirmed the survival benefit of valvular surgery in all patients, which was most significant in patients with CKD. Furthermore, eGFR was preserved in patients who underwent valvular surgery but declined significantly in those who did not.CKD is common in patients with significant VHD and, if left untreated surgically, these patients exhibit a high mortality.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Enfermedades de las Válvulas Cardíacas , Insuficiencia Renal Crónica , Anciano , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Comorbilidad , Femenino , Tasa de Filtración Glomerular , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/epidemiología , Enfermedades de las Válvulas Cardíacas/cirugía , Hong Kong/epidemiología , Humanos , Pruebas de Función Renal/métodos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Gravedad del Paciente , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/mortalidad , Análisis de SupervivenciaRESUMEN
BACKGROUND: Patients who undergo tricuspid annuloplasty during left-side heart valve surgery have a poor postoperative clinical outcome. However, preoperative right ventricular (RV) echocardiography parameters that predict adverse events in these patients are poorly understood. METHODS AND RESULTS: We studied 74 patients (age, 58±10 years; men, 27%) with significant tricuspid regurgitation who consequently underwent tricuspid annuloplasty during left-side heart valve surgery. A total of 26 adverse events (22 heart failures and 4 cardiovascular deaths) occurred during a median follow-up of 26 months. RV midcavity diameter (hazard ratio=2.44; 95% confidence interval=1.48-4.02; P<0.01), RV longitudinal dimension (hazard ratio=1.64; 95% confidence interval=1.10-2.45; P=0.02), and tricuspid valve tethering area (hazard ratio=3.25; 95% confidence interval=1.71-6.19; P<0.01) were independently associated with adverse events after adjustment for age and New York Heart Association class III/IV. Receiver-operator characteristic curve analysis demonstrated that RV midcavity diameter (area under the curve=0.74; P<0.01) and tricuspid valve tethering area (area under the curve=0.70; P=0.04) were most associated with adverse events at the 1-year follow-up. The presence of either a large RV midcavity diameter or tricuspid valve tethering area was predictive of adverse outcome at 1 year after tricuspid annuloplasty. CONCLUSIONS: The present study demonstrates that RV geometry dimensions, namely RV midcavity diameter and tricuspid valve tethering area, are important preoperative measures associated with adverse events in patients undergoing tricuspid annuloplasty.
Asunto(s)
Anuloplastia de la Válvula Cardíaca/métodos , Ventrículos Cardíacos/fisiopatología , Complicaciones Posoperatorias/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Anuloplastia de la Válvula Cardíaca/efectos adversos , Anuloplastia de la Válvula Cardíaca/mortalidad , Ecocardiografía/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Variaciones Dependientes del Observador , Complicaciones Posoperatorias/mortalidad , Valor Predictivo de las Pruebas , Pronóstico , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/mortalidadRESUMEN
BACKGROUND: While statin induces plaque regression, its effects, particularly with different doses on plaque virtual histology composition, remain unknown. METHODS AND RESULTS: In this prospective, randomized, double-blinded study, 40 consecutive statin-naive patients with stable angina requiring percutaneous coronary intervention (PCI) were randomized to 2 arms (20 patients each) receiving 6 months of atorvastatin 10 mg or 40 mg daily. The primary end-point was (VH-IVUS) changes from baseline to 6 months, as assessed by a core laboratory. Fifty-four VH-IVUS lesions were analyzed from the 10 mg group and 57 from the 40 mg group. Overall, plaque volume was reduced by 4.28% (-5.10±14.93 mm(3), P<0.001), absolute VH-IVUS fibrous volume by 10.54% (-4.87±10.74 mm(3), P<0.001), and relative percentage fibrous component by 3.29±7.84% (P<0.001), while relative percentage dense calcium increased by 1.50±3.08% (P<0.001), and necrotic core by 3.19±7.82% (P<0.001). Beneficial changes were more substantial in the higher dose (40 mg) group, with significantly more percentage plaque volume regression (-1.50±3.85% vs. 0.38±4.05% increase in the 10 mg group, P=0.014), less relative percentage necrotic core expansion (1.68±7.57% vs. 4.78±7.82% in the 10 mg group, P=0.037), and without occurrence of major adverse cardiac events (vs. 6 patients in the 10 mg group, P=0.020). CONCLUSIONS: In statin-naive patients requiring PCI, 6 months of atorvastatin induced a significant percentage of plaque volume reduction and substantial modification of VH-IVUS composition. In addition, these effects appeared to vary with different doses of atorvastatin, showing significantly better limitation of relative percentage necrotic core expansion at a higher dose.
Asunto(s)
Anticolesterolemiantes/administración & dosificación , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/terapia , Ácidos Heptanoicos/administración & dosificación , Placa Aterosclerótica/tratamiento farmacológico , Placa Aterosclerótica/patología , Pirroles/administración & dosificación , Anciano , Atorvastatina , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Estudios Prospectivos , Factores de TiempoRESUMEN
BACKGROUND: Liver stiffness (LS) assessed by transient elastography is associated with adverse events in patients with heart failure. However, the predictive value of LS for adverse outcome is uncertain in patients undergoing tricuspid annuloplasty (TA). This study sought to evaluate the prognostic value and reversibility of LS in patients undergoing TA during left-sided valve surgery. METHODS AND RESULTS: A total of 158 patients who underwent TA were prospectively evaluated. Patients were divided into three groups according to tertile of LS. Adverse outcome was defined as heart failure that required hospital admission or all-cause mortality following TA. The median LS was 13.9 (inter-quartile range 8.1-22.3) kPa and independently correlated positively with tricuspid regurgitation (TR) severity, inferior vena cava diameter and negatively with tricuspid annular plane systolic excursion. During a median follow-up of 31 months, 49 adverse events occurred. Multivariable Cox regression analysis revealed that LS was an independent predictor of adverse events. Significant improvement in LS at 1-year post-TA (13.1-7.8 kPa, P < 0.01) was noted only in patients who had no adverse events, not in those who experienced heart failure (17.1-14.2 kPa, P = 0.87) and seems to be linked to an absence of TR recurrence. CONCLUSIONS: This study demonstrated that LS is predictive of adverse outcome and is reversible in patients undergoing TA without TR recurrence at 1 year. These findings suggest that assessing LS, an integrative correlate of right heart condition, may aid the pre-operative risk assessment of candidate for heart surgery including TA.
Asunto(s)
Anuloplastia de la Válvula Cardíaca , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Insuficiencia Cardíaca/etiología , Humanos , Hígado , Pronóstico , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugíaRESUMEN
BACKGROUND: The presence of tricuspid regurgitation (TR) is very common in patients with concomitant left-sided valve disease. Recent studies have advocated an additional grading of massive TR that is beyond severe. The present study sought to characterize the spectrum of TR in patients undergoing tricuspid annuloplasty (TA) and to evaluate the prognostic value of TR severity for post-operative outcome following TA. METHODS: A total of 176 patients who underwent TA with combined left-sided valve surgery, secondary to rheumatic valvular heart disease, were prospectively evaluated. The severity of TR was quantified by effective regurgitant orifice area (EROA) using the proximal isovelocity surface area method. Patients were categorized as having non-massive TR (EROA < 0.6 cm2) or massive TR (EROA ≥ 0.6 cm2). Adverse outcome was defined as all-cause mortality or heart failure requiring hospital admission following TA. RESULTS: A total of 55 (31%) patients were considered to have massive TR. Patients with massive TR had a greater right ventricular dimension but a smaller left ventricular dimension compared with those with non-massive TR. After a median follow-up of 39 months, 35 adverse events occurred. Cox-regression analysis showed that both continuous EROA and dichotomized EROA (massive vs. non-massive TR) were independently associated with adverse events even after multivariable adjustment. Further, Harrell C index demonstrated that the addition of massive TR provided better discrimination ability of a prediction model to known prognosticators following TA. CONCLUSIONS: Massive TR is common and up to 31% of study population had massive TR. Massive TR was associated with adverse outcome in patients undergoing TA. Classification of the severity of TR by quantitative measures and identification of massive TR in patients with concomitant left-sided valve disease are essential when considering the optimal timing of corrective surgery.
RESUMEN
BACKGROUND: We evaluated the long term clinical outcomes of femoral vascular closure devices following its deployment in coronary angiography and percutaneous coronary intervention (PCI) procedures. METHODS: From June 2000 to September 2004, 265 patients who received femoral vascular closure devices after coronary angiography and PCIs were enrolled into the study. Patients' medical records were reviewed and vascular complications within 1 year of follow-up period were recorded. Rutherford's categories of claudication were used to quantify different degrees of claudication and leg ischaemia. Duplex ultrasonography of both femoral arteries (using the nonaccessed site as control) was performed at 1 year after deployment of vascular closure devices. Vessel diameter and flow velocities for both common femoral arteries were obtained. RESULTS: There was no occurrence of late vascular complications like arteriovenous fistula, pseudoaneurysm, surgical repair of access site complications, late groin bleeding and infection. By Rutherford categories of claudication, 99.2% of patients had grade 0 claudication while the remaining 0.8% was in grade 1. By arterial Duplex ultrasonography, the peak systolic velocity of the accessed femoral artery (predominantly right side) was nonsignificantly higher, 94.9 + or - 26.0 cm/s when compared to 91.5 + or - 24.8 cm/s in the control site (P = 0.12). As for vessel diameter, no significant difference was found in the mean end-diastolic vessel diameter 8.8 + or - 1.3 mm (puncture site) versus 8.7 + or - 4.4 mm (control site) (P = 0.72). CONCLUSION: We found that the use of femoral closure devices was safe and it was not associated with any adverse long term vascular complications.
Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Arteria Femoral , Técnicas Hemostáticas/instrumentación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Punciones , Resultado del TratamientoRESUMEN
Implementation of a critical care pathway (CCP) for acute coronary syndrome (ACS) has been shown to improve early compliance to guideline-directed therapies and reduce early mortality. Nevertheless its long-term impact on the compliance with medications or clinical outcomes remains unknown. Between 2004 and 2015, 2023 consecutive patients were admitted to our coronary care unit with ACS. We retrospectively compared the outcomes of 628 versus 1059 patients (mean age 66.1 ± 13.3 years, 74% male) managed before and after full implementation of a CCP. Compared with standard care, implementation of the CCP significantly increased coronary revascularization and long-term compliance with guideline-directed medical therapy (both P < 0.01). After a mean follow-up of 66.5 ± 44.0 months, 46.7% and 22.2% patients admitted before and after implementation of the CCP, respectively, died. Kaplan-Meier analyses showed that patients managed by CCP had better overall survival (P = 0.03) than those managed with standard care. After adjustment for clinical covariates and coronary anatomy, CCP remained independently predictive of better survival from all-cause mortality [hazard ratio (HR): 0.75, 95%confidence intervals (CI): 0.62-0.92, P < 0.01]. Stepwise multivariate cox regression model showed that both revascularization (HR: 0.55, 95%CI: 0.45-0.68, P < 0.01) and compliance to statin (HR: 0.70, 95%CI: 0.58-0.85, P < 0.01) were accountable for the improved outcome.
Asunto(s)
Síndrome Coronario Agudo/terapia , Cuidados Críticos/métodos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Cooperación del Paciente/estadística & datos numéricos , Síndrome Coronario Agudo/mortalidad , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Mortalidad , Guías de Práctica Clínica como Asunto , Estudios Retrospectivos , Nivel de Atención , Resultado del TratamientoRESUMEN
BACKGROUND: The advent of three-dimensional echocardiography (3DE) enables detailed evaluation of the tricuspid valve (TV) apparatus; nonetheless, the clinical value of preoperative 3DE is unknown in patients undergoing tricuspid annuloplasty (TA). The aim of this study was to evaluate the prognostic value of TV geometric parameters and leaflet coaptation status evaluated by 3DE in patients undergoing TA. METHODS: A total of 122 patients who underwent TA during left-sided heart valve surgery were prospectively evaluated. Detailed 3DE was performed before surgery. Adverse outcome was defined as the occurrence of heart failure requiring hospital admission or all-cause mortality following TA. RESULTS: A total of 33 adverse events (17 heart failures and 16 deaths) occurred during a median follow-up of 36 months. Tethering volume (hazard ratio = 1.32; 95% CI = 1.05-1.66; P = .01) and ratio of total leaflet length to closure length (hazard ratio = 1.07; 95% CI = 1.03-1.12; P < .01) were associated with adverse events after adjustment for age, sex, and tricuspid regurgitation vena contracta width. Receiver-operator characteristic curve analysis revealed that tethering volume (area under curve = 0.73) and ratio of total leaflet length to closure length (area under curve = 0.75) were most associated with adverse events at 1-year follow-up. The presence of either a large tethering volume or a low ratio of total leaflet length to closure length was predictive of an adverse outcome 1 year following TA. CONCLUSIONS: Our study suggests that 3DE-derived TV tethering volume and ratio of total leaflet length to closure length are important preoperative measures associated with adverse events in patients undergoing TA.
Asunto(s)
Anuloplastia de la Válvula Cardíaca/métodos , Ecocardiografía Tridimensional/métodos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Anciano , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Curva ROC , Medición de Riesgo , Resultado del Tratamiento , Válvula Tricúspide/cirugíaRESUMEN
There is no surrogate marker in serum for defining disease activity in scleroderma (SSc). Nitric oxide (NO), which regulates vasodilation and possesses pro-inflammatory actions, has been implicated in the pathogenesis of SSc. We compared serum NO(x) (total nitrate and nitrite) level in SSc patients to healthy controls and evaluated its correlation with detailed symptomatology and scoring systems for various organ involvement. Symptoms and physical findings that suggested disease activity in regard to various organs were documented. Lung function test, high-resolution computed tomographic (HRCT) scan of thorax and echocardiography were performed. Serum NO(x) was measured by chemiluminescence. Serum NO(x) levels in SSc (n = 43) were significantly higher (72.4 +/- 47.8 microM) than age- and sex-matched controls (n = 41; 37.1 +/- 13.5 microM; p < 0.001). Serum NO(x) were not found to be associated with lung fibrosis defined by lung function parameters or inflammation and fibrosis scores on HRCT. Twenty-two patients were found to have elevated serum NO(x) level defined as mean +/- 2 SD of normal controls. Logistic regression analysis revealed that age (OR 1.12, p = 0.02) and elevated pulmonary arterial pressure (PAP) (n = 9; OR 145.3, p = 0.01) were predictive factors for elevated serum NO(x). Prednisolone use was associated with lower serum NO(x) level (OR 0.06, p = 0.04). Elevated PAP of increasing severity was found to be associated with higher level of serum NO(x) (p = 0.004 by trend). Serum NO(x) in SSc patients were elevated compared to healthy controls. Serum NO(x) level was determined by multiple factors including age, prednisolone use, and elevated PAP.
Asunto(s)
Óxido Nítrico/sangre , Esclerodermia Sistémica/sangre , Adulto , Antiinflamatorios/farmacología , Biomarcadores/sangre , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Óxido Nítrico/inmunología , Óxido Nítrico/metabolismo , Prednisolona/farmacología , Esclerodermia Sistémica/tratamiento farmacológico , Esclerodermia Sistémica/inmunología , Índice de Severidad de la EnfermedadRESUMEN
Objective To evaluate the 1-year clinical outcomes of patients who received the Resolute Onyx™ stent. Methods This was a single-centre, retrospective registry analysis that reviewed the clinical data from all patients who were implanted with a Resolute Onyx™ stent between March 2015 and February 2016. Clinical follow-up was performed at 1 year post-implantation. Results A total of 252 patients received a Resolute Onyx™ stent and two patients were lost to follow-up. The mean age of the cohort was 66.9 years and 113 (45.2%) had diabetes mellitus. Thirty-eight patients (15.2%) had left main disease and 73 (29.2%) had three-vessel disease. A total of 175 patients (70.0%) had small vessel disease (<2.75 mm) and 210 (84.0%) had long lesions (>20 mm). The 1-year target lesion failure was 4.4% (11 of 250), cardiovascular death occurred in eight patients (3.2%), ischaemia-driven target lesion revascularization was undertaken in five patients (2.0%) and stent thrombosis occurred in one patient (0.4%). Conclusion The Resolute Onyx™ stent showed a favourable 1-year clinical performance in a real-world population.
Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Trombosis Coronaria/tratamiento farmacológico , Diabetes Mellitus/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Infarto del Miocardio/tratamiento farmacológico , Sistema de Registros , Sirolimus/análogos & derivados , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/mortalidad , Trombosis Coronaria/cirugía , Diabetes Mellitus/diagnóstico por imagen , Diabetes Mellitus/mortalidad , Diabetes Mellitus/cirugía , Stents Liberadores de Fármacos , Femenino , Humanos , Inmunosupresores/farmacocinética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea , Estudios Retrospectivos , Sirolimus/farmacocinética , Sirolimus/uso terapéutico , Análisis de Supervivencia , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: The Model for End-stage Liver Disease excluding international normalized ratio (MELD-XI) score and the modified MELD score with albumin replacing international normalized ratio (MELD-Albumin) score, which reflect both liver and renal function, have been reported as predictors of adverse events in liver and heart disease. Nonetheless, their prognostic value in patients undergoing tricuspid annuloplasty has not been addressed. METHODS AND RESULTS: A total of 394 patients who underwent tricuspid annuloplasty were evaluated. Baseline clinical, laboratory, and echocardiographic parameters were recorded. Adverse outcome was defined as the occurrence of heart failure requiring admission or all-cause mortality. Patients who underwent tricuspid annuloplasty had a high prevalence of preoperative hepatorenal dysfunction that was more common in patients with severe tricuspid regurgitation than those with mild to moderate tricuspid regurgitation. The MELD-XI and MELD-Albumin scores were excellent predictors of 1-year adverse outcome (area under the curve: 0.69 and 0.75, respectively). Kaplan-Meier survival curve demonstrated that a high score on MELD-XI (≥12.0) and MELD-Albumin (≥10.7) was associated with an increased risk of adverse events. During a median follow-up of 40 months, both MELD-XI and MELD-Albumin scores were significantly associated with adverse outcome, even after adjusting for potential confounding factors. Significant improvement of hepatorenal function at 1 year postoperation was noted only in patients who had no adverse events, not in those who experienced an adverse outcome. CONCLUSIONS: Both MELD-XI score and MELD-Albumin score can provide useful information to predict adverse outcome in patients undergoing tricuspid annuloplasty. The present study supports monitoring of modified MELD score to improve preoperative risk stratification of these patients.
Asunto(s)
Bilirrubina/metabolismo , Anuloplastia de la Válvula Cardíaca , Creatinina/metabolismo , Albúmina Sérica/metabolismo , Insuficiencia de la Válvula Tricúspide/cirugía , Anciano , Enfermedad Hepática en Estado Terminal , Femenino , Humanos , Relación Normalizada Internacional , Pruebas de Función Renal , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Pronóstico , Modelos de Riesgos Proporcionales , Índice de Severidad de la EnfermedadRESUMEN
BACKGROUND: Tricuspid annuloplasty (TA) is increasingly being performed, but the clinical outcome is unsatisfactory. Acute kidney injury (AKI) is a common complication following cardiac surgery and predicts outcome. Nonetheless the occurrence rate and prognostic value of AKI after TA are unclear. METHODS: This study reviewed 339 consecutive patients (age 65±11 years; male 42%) who underwent TA. The incidence of AKI was defined according to risk/injury/failure/loss/end stage (RIFLE), acute kidney injury network (AKIN), and kidney disease improving global outcomes (KDIGO) criteria, respectively. Major adverse cardiovascular events (MACE) was defined as death, heart failure, stroke, and myocardial infarction (MI). The influence of AKI on MACE was evaluated as a short-term outcome and outcome beyond 30 days. RESULTS: The incidence of AKI, defined according to RIFLE, AKIN, and KDIGO was 57%, 52%, and 53%, respectively. MACE occurred in 94 cases (21 deaths, 63 heart failure requiring hospitalization, 7 stroke, and 3 MI). For short-term outcome, AKI defined by all three scoring systems was independently associated with MACE and death (p<0.01 for both), but not heart failure, stroke, or MI. For outcome beyond 30 days, AKI by all three criteria was associated with MACE and heart failure. Only AKI by AKIN and KDIGO, but not RIFLE, was independently associated with death. CONCLUSION: Our data suggest AKI affects over half of all patients who undergo TA, and has a major and long-lasting impact on survival, MACE, and heart failure. Use of AKIN and KDIGO is more useful than the RIFLE criteria when determining the prognostic value of AKI for mortality beyond 30 days.
Asunto(s)
Lesión Renal Aguda/mortalidad , Anuloplastia de la Válvula Cardíaca/efectos adversos , Enfermedades Cardiovasculares/mortalidad , Complicaciones Posoperatorias/mortalidad , Medición de Riesgo/métodos , Lesión Renal Aguda/etiología , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Enfermedades Cardiovasculares/etiología , Consenso , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Válvula Tricúspide/cirugíaRESUMEN
BACKGROUND: Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer. METHODS AND RESULTS: Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months (P<0.001) and less variance of percent coverage at 9 months, 99.7% (interquartile range, 99.1-100) versus 99.6% (interquartile range, 96.8-99.9; difference, 0.10; 95% confidence interval, 0.00-1.05; P<0.001). No significant difference was observed in major adverse cardiac events or angiographic end points. CONCLUSIONS: Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01742507.
Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Neointima , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica , Anciano , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Vasos Coronarios/diagnóstico por imagen , Femenino , Hong Kong , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del TratamientoRESUMEN
AIMS: This study aimed to establish the early healing and neointimal transformation profile of the new polymer-free BioFreedom stent through sequential optical coherence tomography (OCT) within the first nine months following stent implantation. METHODS AND RESULTS: We randomly assigned 104 BFS recipients to one of five groups with angiography and OCT follow-up at 1, 2, 3, 4, or 5 months, together with another follow-up for all at nine months. The primary endpoint was the degree of OCT-detected strut coverage at nine months. From 1, 2, 3, 4, and 5 months, median neointimal strut coverage increased from 85.8, 87.0, 88.6, 96.8 to 97.1%, respectively, to 99.6% (IQR 98.2-99.9) at nine months. At nine months, median percent neointimal volume was 13.0% and angiographic late lumen loss was 0.21±0.30 mm. Major adverse cardiac events (MACE) were limited to one non-cardiac death, one non-ST-elevation myocardial infarction not related to BFS, and two target lesion revascularisations without stent thrombosis (MACE rate 4.0%). CONCLUSIONS: Neointimal strut coverage of the BFS was rapid and the BFS was shown to be clinically safe and effective.
Asunto(s)
Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angiografía Coronaria , Humanos , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/análogos & derivados , Tomografía de Coherencia Óptica , Resultado del TratamientoRESUMEN
OBJECTIVES: Tricuspid regurgitation (TR) is common in patients referred for cardiac assessment. Nonetheless, current estimates of its prevalence and contributing factors are limited. The aim of the present study was to evaluate the prevalence and demographics of TR in patients referred for echocardiography assessment at two University-affiliated hospitals. METHODS: A total of 6711 consecutive Chinese patients were recruited as part of the Chinese Valvular Heart Disease Study (CVATS). RESULTS: The most common valvular lesion was TR (54.7%), followed by mitral regurgitation (44.7%) and aortic regurgitation (26.5%). Clinically significant (moderate or severe) TR was identified in 8.4% with the proportion increased from 3.9% amongst those aged <51 to 15.9% in those aged ≥81. Multivariable adjustment demonstrated that significant TR was associated with age, congenital heart disease, chronic obstructive pulmonary disease, left-sided valvular heart disease (VHD), impaired left ventricular ejection fraction <50%, atrial fibrillation and pulmonary hypertension. CONCLUSIONS: Among all types of VHD, TR was the most common and was identified in over half of the subjects and clinically significant in 8.4%. These unique data provide contemporary clinical and epidemiological characteristics of TR in a large cohort of patients referred for cardiac assessment and confirm the increased burden of TR in the aged population.
Asunto(s)
Insuficiencia de la Válvula Tricúspide/epidemiología , Factores de Edad , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/epidemiología , China/epidemiología , Comorbilidad , Diabetes Mellitus/epidemiología , Femenino , Humanos , Hiperlipidemias/epidemiología , Hipertensión Pulmonar/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Factores de Riesgo , Insuficiencia de la Válvula Tricúspide/clasificación , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagenAsunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/terapia , Enfermedad Iatrogénica , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de PrótesisRESUMEN
BACKGROUND: Tricuspid annuloplasty is increasingly performed during left heart valve surgery, but the long-term clinical outcome postoperatively is not satisfactory. The aim of this study was to determine whether residual pulmonary hypertension (PHT) contributes to the adverse outcome. METHODS AND RESULTS: One-hundred thirty-seven patients (age 61±11 years; men, 30%) who underwent tricuspid annuloplasty during left-side valve surgery were enrolled. The mean pulmonary artery systolic pressure before surgery was 49±13 mm Hg and 32±15 mm Hg following surgery. Patients were divided into 3 groups according to postoperative pulmonary artery systolic pressure: no residual PHT (n=78, 57%), mild residual PHT (n=43, 31%), or significant residual PHT (n=16, 12%). A preoperative larger right ventricular (RV) geometry and tricuspid valve tethering area were associated with mild or significant residual PHT. A total of 24 adverse events (20 heart failures and 4 cardiovascular deaths) occurred during a median follow-up of 25 months. Kaplan-Meier survival curve demonstrated that patients with significant residual PHT had the highest percentage of adverse events followed by those with mild residual PHT. Patients with no residual PHT had a very low risk of adverse events. Multivariable Cox regression analysis revealed that both mild (hazard ratio=4.94; 95% CI =1.34-18.16; P=0.02) and significant residual PHT (hazard ratio=8.67; 95% CI =2.43-30.98; P<0.01) were independent factors associated with adverse events. CONCLUSIONS: The present study demonstrated that 43% of patients who underwent tricuspid annuloplasty had residual PHT. The presence of mild or significant residual PHT was associated with adverse events in these patients.
Asunto(s)
Anuloplastia de la Válvula Cardíaca , Enfermedades Cardiovasculares/mortalidad , Insuficiencia Cardíaca/epidemiología , Enfermedades de las Válvulas Cardíacas/cirugía , Hipertensión Pulmonar/epidemiología , Cardiopatía Reumática/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Fibrilación Atrial/epidemiología , Comorbilidad , Ecocardiografía , Femenino , Enfermedades de las Válvulas Cardíacas/epidemiología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Prevalencia , Modelos de Riesgos Proporcionales , Cardiopatía Reumática/epidemiología , Volumen Sistólico , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/epidemiologíaRESUMEN
BACKGROUND: Biventricular pacing has been proposed to improve symptoms and exercise capacity in patients with advanced heart failure and wide electrocardiographic wave complexes. This study investigated the effect of biventricular pacing on reverse remodeling and the underlying mechanisms. METHODS AND RESULTS: Twenty-five patients with NYHA class III to IV heart failure and electrocardiographic wave complex duration >140 ms receiving biventricular pacing therapy were assessed serially up to 3 months after pacing and when pacing was withheld for 4 weeks. Tissue Doppler echocardiography was performed using a 6-basal, 6-mid segmental model to assess the time to peak sustained systolic contraction (T(S)). There was significant improvement of ejection fraction, dP/dt, and myocardial performance index; decrease in mitral regurgitation, left ventricular (LV) end-diastolic (205+/-68 versus 168+/-67 mL, P<0.01) and end-systolic volume (162+/-54 versus 122+/-42 mL, P<0.01); and improved 6-minute hall-walk distance and quality of life score after pacing for 3 months. The mechanisms of benefits were as follows: (1) improved LV synchrony, as evident by homogeneous delay of T(S) to a timing close to the latest (usually the lateral) segment abolishing the intersegmental difference in T(S) and decreasing the standard deviation of T(S) within the left ventricle (37.7+/-10.9 versus 29.3+/-8.3 ms, P<0.05); (2) improved interventricular synchrony; and (3) shortened isovolumic contraction time (122+/-57 versus 82+/-36 ms, P<0.05) but increased diastolic filling time. These benefits are pacing dependent, because withholding the pacing resulted in varying speeds in the loss of cardiac improvements. CONCLUSIONS: Biventricular pacing reverses LV remodeling and improves cardiac function. Improvement of LV mechanical synchrony seems to be the predominant mechanism.