Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Aerosol Sci ; 99: 27-39, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27493296

RESUMEN

Despite substantial development of sophisticated subject-specific computational models of aerosol transport and deposition in human lungs, experimental validation of predictions from these new models is sparse. We collected aerosol retention and exhalation profiles in seven healthy volunteers and six subjects with mild-to-moderate COPD (FEV1 = 50-80%predicted) in the supine posture. Total deposition was measured during continuous breathing of 1 and 2.9 µm-diameter particles (tidal volume of 1 L, flow rate of 0.3 L/s and 0.75 L/s). Bolus inhalations of 1 µm particles were performed to penetration volumes of 200, 500 and 800 mL (flow rate of 0.5 L/s). Aerosol bolus dispersion (H), deposition, and mode shift (MS) were calculated from these data. There was no significant difference in total deposition between healthy subjects and those with COPD. Total deposition increased with increasing particle size and also with increasing flow rate. Similarly, there was no significant difference in aerosol bolus deposition between subject groups. Yet, the rate of increase in dispersion and of decrease in MS with increasing penetration volume was higher in subjects with COPD than in healthy volunteers (H: 0.798 ± 0.205 vs. 0.527 ± 0.122 mL/mL, p=0.01; MS: -0.271±0.129 vs. -0.145 ± 0.076 mL/mL, p=0.05) indicating larger ventilation inhomogeneities (based on H) and increased flow sequencing (based on MS) in the COPD than in the healthy group. In conclusion, in the supine posture, deposition appears to lack sensitivity for assessing the effect of lung morphology and/or ventilation distribution alteration induced by mild-to-moderate lung disease on the fate of inhaled aerosols. However, other parameters such as aerosol bolus dispersion and mode shift may be more sensitive parameters for evaluating models of lungs with moderate disease.

2.
Exp Lung Res ; 41(3): 135-45, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25513951

RESUMEN

PURPOSE: Computer models for inhalation toxicology and drug-aerosol delivery studies rely on ventilation pattern inputs for predictions of particle deposition and vapor uptake. However, changes in lung mechanics due to disease can impact airflow dynamics and model results. It has been demonstrated that non-invasive, in vivo, 4DCT imaging (3D imaging at multiple time points in the breathing cycle) can be used to map heterogeneities in ventilation patterns under healthy and disease conditions. The purpose of this study was to validate ventilation patterns measured from CT imaging by exposing the same rats to an aerosol of fluorescent microspheres (FMS) and examining particle deposition patterns using cryomicrotome imaging. MATERIALS AND METHODS: Six male Sprague-Dawley rats were intratracheally instilled with elastase to a single lobe to induce a heterogeneous disease. After four weeks, rats were imaged over the breathing cycle by CT then immediately exposed to an aerosol of ∼ 1 µm FMS for ∼ 5 minutes. After the exposure, the lungs were excised and prepared for cryomicrotome imaging, where a 3D image of FMS deposition was acquired using serial sectioning. Cryomicrotome images were spatially registered to match the live CT images to facilitate direct quantitative comparisons of FMS signal intensity with the CT-based ventilation maps. RESULTS: Comparisons of fractional ventilation in contiguous, non-overlapping, 3D regions between CT-based ventilation maps and FMS images showed strong correlations in fractional ventilation (r = 0.888, p < 0.0001). CONCLUSION: We conclude that ventilation maps derived from CT imaging are predictive of the 1 µm aerosol deposition used in ventilation-perfusion heterogeneity inhalation studies.


Asunto(s)
Aerosoles/metabolismo , Pulmón/diagnóstico por imagen , Ventilación Pulmonar/fisiología , Administración por Inhalación , Animales , Imagenología Tridimensional/métodos , Pulmón/metabolismo , Pulmón/fisiología , Masculino , Microesferas , Ratas , Ratas Sprague-Dawley , Respiración , Tomografía Computarizada por Rayos X/métodos
3.
Nat Methods ; 8(1): 91-6, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21151136

RESUMEN

Real-time imaging of cellular and subcellular dynamics in vascularized organs requires image resolution and image registration to be simultaneously optimized without perturbing normal physiology. This problem is particularly pronounced in the lung, in which cells may transit at speeds >1 mm s(-1) and in which normal respiration results in large-scale tissue movements that prevent image registration. Here we report video-rate, two-photon imaging of a physiologically intact preparation of the mouse lung that is stabilizing and nondisruptive. Using our method, we obtained evidence for differential trapping of T cells and neutrophils in mouse pulmonary capillaries, and observed neutrophil mobilization and dynamic vascular leak in response to stretch and inflammatory models of lung injury in mice. The system permits physiological measurement of motility rates of >1 mm s(-1), observation of detailed cellular morphology and could be applied in the future to other organs and tissues while maintaining intact physiology.


Asunto(s)
Imagenología Tridimensional/métodos , Vigilancia Inmunológica/inmunología , Pulmón/citología , Pulmón/inmunología , Movimiento , Animales , Pulmón/irrigación sanguínea , Ratones , Microscopía Fluorescente
4.
Crit Care Med ; 39(3): 527-32, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21187747

RESUMEN

OBJECTIVES: To adapt an animal model of acute lung injury for use as a standard protocol for a screening initial evaluation of limited function, or "surge," ventilators for use in mass casualty scenarios. DESIGN: Prospective, experimental animal study. SETTING: University research laboratory. SUBJECTS: Twelve adult pigs. INTERVENTIONS: Twelve spontaneously breathing pigs (six in each group) were subjected to acute lung injury/acute respiratory distress syndrome via pulmonary artery infusion of oleic acid. After development of respiratory failure, animals were mechanically ventilated with a limited-function ventilator (simplified automatic ventilator [SAVe] I or II; Automedx, Germantown, MD) for 1 hr or until the ventilator could not support the animal. The limited-function ventilator was then exchanged for a full-function ventilator (Servo 900C; Siemens-Elema, Solna, Sweden). MEASUREMENTS AND MAIN RESULTS: Reliable and reproducible levels of acute lung injury/acute respiratory distress syndrome were induced. The SAVe I was unable to adequately oxygenate five animals with Pao2 (52.0±11.1 torr) compared to the Servo (106.0±25.6 torr; p=.002). The SAVe II was able to oxygenate and ventilate all six animals for 1 hr with no difference in Pao2 (141.8±169.3 torr) compared to the Servo (158.3±167.7 torr). CONCLUSIONS: We describe a novel in vivo model of acute lung injury/acute respiratory distress syndrome that can be used to initially screen limited-function ventilators considered for mass respiratory failure stockpiles and that is intended to be combined with additional studies to definitively assess appropriateness for mass respiratory failure. Specifically, during this study we demonstrate that the SAVe I ventilator is unable to provide sufficient gas exchange, whereas the SAVe II, with several more functions, was able to support the same level of hypoxemic respiratory failure secondary to acute lung injury/acute respiratory distress syndrome for 1 hr.


Asunto(s)
Lesión Pulmonar Aguda/terapia , Modelos Animales de Enfermedad , Respiración Artificial , Síndrome de Dificultad Respiratoria/terapia , Enfermedades de los Porcinos/terapia , Lesión Pulmonar Aguda/fisiopatología , Animales , Análisis de los Gases de la Sangre , Presión Sanguínea/fisiología , Respiración con Presión Positiva , Respiración Artificial/instrumentación , Síndrome de Dificultad Respiratoria/fisiopatología , Insuficiencia Respiratoria/fisiopatología , Insuficiencia Respiratoria/terapia , Porcinos , Enfermedades de los Porcinos/fisiopatología
5.
J Appl Physiol (1985) ; 128(2): 309-323, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31774357

RESUMEN

To facilitate computational toxicology, we developed an approach for generating high-resolution lung-anatomy and particle-deposition mouse models. Major processing steps of our method include mouse preparation, serial block-face cryomicrotome imaging, and highly automated image analysis for generating three-dimensional (3D) mesh-based models and volume-based models of lung anatomy (airways, lobes, sublobes, and near-acini structures) that are linked to local particle-deposition measurements. Analysis resulted in 34 mouse models covering 4 different mouse strains (B6C3F1: 8, BALB/C: 11, C57Bl/6: 8, and CD-1: 7) as well as both sexes (16 male and 18 female) and different particle sizes [2 µm (n = 15), 1 µm (n = 16), and 0.5 µm (n = 3)]. On average, resulting mouse airway models had 1,616.9 ± 298.1 segments, a centerline length of 597.6 ± 59.8 mm, and 1,968.9 ± 296.3 outlet regions. In addition to 3D geometric lung models, matching detailed relative particle-deposition measurements are provided. All data sets are available online in the lapdMouse archive for download. The presented approach enables linking relative particle deposition to anatomical structures like airways. This will in turn improve the understanding of site-specific airflows and how they affect drug, environmental, or biological aerosol deposition.NEW & NOTEWORTHY Computer simulations of particle deposition in mouse lungs play an important role in computational toxicology. Until now, a limiting factor was the lack of high-resolution mouse lung models and measured local particle-deposition information, which are required for developing accurate modeling approaches (e.g., computational fluid dynamics). With the developed imaging and analysis approach, we address this issue and provide all of the raw and processed data in a publicly accessible repository.


Asunto(s)
Administración por Inhalación , Aerosoles , Pulmón/anatomía & histología , Modelos Biológicos , Animales , Simulación por Computador , Femenino , Hidrodinámica , Procesamiento de Imagen Asistido por Computador , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Tamaño de la Partícula
6.
J Appl Physiol (1985) ; 107(3): 755-62, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19608933

RESUMEN

Previous studies reported that regional CO(2) tension might affect regional ventilation (V) following acute pulmonary thromboembolism (APTE). We investigated the pathophysiology and magnitude of these changes. Eight anesthetized and ventilated piglets received autologous clots at time = 0 min until mean pulmonary artery pressure was 2.5 times baseline. The distribution of V and perfusion (Q) at four different times (-5, 30, 60, 120 min) was mapped by fluorescent microspheres. Regional V and Q were examined postmortem by sectioning the air-dried lung into 900-1,000 samples of approximately 2 cm(3) each. After the redistribution of regional Q by APTE, but in the scenario assuming that no V shift had yet occurred, CO(2) tension in different lung regions at 30 min post-APTE (P(X)CO(2)) was estimated from the V/Q data and divided into four distinct clusters: i.e., P(X)CO(2) < 10 Torr; 10 < P(X)CO(2) < 25 Torr; 25 < P(X)CO(2) < 50 Torr; P(X)CO(2) > 50 Torr. Our data showed that the clusters in higher V/Q regions (with a P(X)CO(2) < 25 Torr) received approximately 35% less V when measured within 30 min of APTE, whereas, in contrast, the lower V/Q regions showed no statistically significant increases in their V. However, after 30 min, there was minimal further redistribution of V. We conclude that there are significant compensatory V shifts out of regions of low CO(2) tension soon following APTE, and that these variations in regional CO(2) tension, which initiate CO(2)-dependent changes in airway resistance and lung parenchymal compliance, can lead to improved gas exchange.


Asunto(s)
Dióxido de Carbono/metabolismo , Homeostasis/fisiología , Embolia Pulmonar/fisiopatología , Mecánica Respiratoria/fisiología , Enfermedad Aguda , Umbral Anaerobio/fisiología , Animales , Análisis de los Gases de la Sangre , Análisis por Conglomerados , Hemodinámica/fisiología , Pulmón/patología , Microesferas , Alveolos Pulmonares/fisiología , Embolia Pulmonar/patología , Intercambio Gaseoso Pulmonar/fisiología , Porcinos , Volumen de Ventilación Pulmonar/fisiología
7.
J Appl Physiol (1985) ; 102(2): 762-71, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17082362

RESUMEN

We studied the roles of endothelins in determining ventilation (Va) and perfusion (Q) mismatch in a porcine model of acute pulmonary thromboembolism (APTE), using a nonspecific endothelin antagonist, tezosentan. Nine anesthetized piglets (approximately 23 kg) received autologous clots (approximately 20 g) via a central venous catheter at time = 0 min. The distribution of Va and Q at five different time points (-30, -5, 30, 60, 120 min) was mapped by fluorescent microspheres of 10 different colors. Five piglets (group 1) received tezosentan (courtesy of Actelion) starting at time = 40 min for 2 h, and four piglets (group 2) received only saline and served as control. Our results showed that, in all of the animals at 30 min following APTE but before tezosentan, the mean Va/Q was increased, as was Va/Q heterogeneity (log SD Va/Q), which represented a widening of its main peak. Afterwards, tezosentan attenuated the pulmonary hypertension in group 1 but also produced moderate systemic hypotension. However, it did not improve arterial PO2 or Va/Q mismatch. We concluded that endothelin antagonism had minimal impact on gas exchange following APTE and confirmed our earlier observation that the main mechanism for hypoxemia in APTE was due to the mechanical redistribution of pulmonary regional blood flow away from the embolized vessels, resulting in the creation of many divergent low and high Va/Q regions.


Asunto(s)
Antagonistas de los Receptores de Endotelina , Hipoxia/etiología , Hipoxia/fisiopatología , Embolia Pulmonar/complicaciones , Embolia Pulmonar/fisiopatología , Enfermedad Aguda , Animales , Modelos Animales de Enfermedad , Imagenología Tridimensional , Pulmón/irrigación sanguínea , Pulmón/fisiopatología , Microesferas , Intercambio Gaseoso Pulmonar/efectos de los fármacos , Intercambio Gaseoso Pulmonar/fisiología , Ventilación Pulmonar/efectos de los fármacos , Ventilación Pulmonar/fisiología , Piridinas/farmacología , Receptores de Endotelina/efectos de los fármacos , Flujo Sanguíneo Regional/efectos de los fármacos , Flujo Sanguíneo Regional/fisiología , Porcinos , Tetrazoles/farmacología , Vasodilatadores/farmacología , Relación Ventilacion-Perfusión/efectos de los fármacos , Relación Ventilacion-Perfusión/fisiología
8.
Respir Physiol Neurobiol ; 159(1): 76-84, 2007 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-17804304

RESUMEN

Studies in whole animals, isolated lungs and pulmonary tissue strips have shown that the pulmonary vascular resistance (PVR) to hypoxia is temporally biphasic in nature. We studied the regional temporal response to hypoxia in prone pigs. The animals were ventilated with an FIO2 of 0.21 (control), followed by an FIO2 of 0.12 for 180 min. A biphasic response in P(pa) to hypoxia was seen with the first peak between 10 and 20 min and a second rise in P(pa) starting after 30 min, which was due to an increase in cardiac output. Regional blood flow (Q ) and ventilation (V (A)) were measured using i.v. infusion of 15 microm and inhalation of 1 microm fluorescent microspheres, respectively. We grouped the lung pieces according to their temporal relative flow response to hypoxia. The five groups were each spatially distributed similarly, but not identically, among the animals. The corresponding relative ventilation to each group did not vary much. We conclude that in the prone pig, the PVR response to sustained hypoxia varies among regions of the lungs. Following an initial rise in PVR in most lung pieces, we found unexpectedly that some regions continue to increase PVR progressively and while other regions decrease PVR after the initial increase. The net effect is little change of overall PVR to hypoxia with time. Normoxic control animals had little change in their hemodynamics and the large majority of the lung pieces did not change their resistance over 3h. We speculate that the differential response of regions may be due to a differential role of nitric oxide, endothelin-1 release or K(+) channels.


Asunto(s)
Hipoxia/fisiopatología , Pulmón/irrigación sanguínea , Circulación Pulmonar/fisiología , Resistencia Vascular/fisiología , Vasoconstricción/fisiología , Animales , Posición Prona , Porcinos
9.
Chest ; 130(1): 85-92, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16840387

RESUMEN

STUDY OBJECTIVES: Hypercapnic acidosis has antiinflammatory effects in animal models of acute lung injury (ALI) and improves ventilation-perfusion (V/Q) matching in normal lungs. The effect of hypercapnia on V/Q matching in ALI is conflicting. Hypercapnic acidosis produced by reduced tidal volumes (Vts) was associated with an increased shunt fraction (QS/QT) in patients with ALI compared with control subjects. Vt differences between groups make the assessment of hypercapnic acidosis on V/Q matching difficult. Adding CO2 to the inhaled gas allows the comparison of gas exchange under identical Vt conditions. We hypothesized the presence of hypercapnic acidosis from inspired carbon dioxide (ICD) would improve gas exchange in ALI and would be superior to that of low minute ventilation (LVe) produced by reduced respiratory rate, rather than Vt. DESIGN: University laboratory study of anesthetized New Zealand White rabbits. INTERVENTIONS: Assessment of V/Q relationships using the multiple inert gas elimination technique was performed in 10 saline solution-lavaged animals, which were ventilated with 6 mL/kg Vts and a positive end-expiratory pressure of 8 cm H2O. Each rabbit was studied while it was in eucapnia, followed by hypercapnia (Pa(CO2), 95 to 100 mm Hg) induced by LVe from decreased respiratory rate and by 10% ICD, in random order. MEASUREMENTS AND RESULTS: The Pa(O2) was greater in ICD and LVe compared to eucapnia, but no significant differences in alveolar-arterial oxygen pressure difference or Pa(O2)/fraction of inspired oxygen ratio occurred. LVe statistically reduced the mean V/Q distributions compared with ICD and eucapnia. Log SDs of ventilation and combined retention and excretion curves of the dispersion index were both increased during LVe, indicating the presence of unfavorable changes in ventilation distribution. Neither LVe nor ICD altered the QS/QT. CONCLUSIONS: LVe slightly impairs overall gas exchange and ventilation distribution, but does not increase QS/QT compared with eucapnia and ICD. While ICD does not significantly improve gas exchange, it may be superior to LVe in achieving the antiinflammatory effects of "therapeutic" hypercapnia, since it does not adversely alter gas exchange and has the potential to make the lung more uniformly acidotic.


Asunto(s)
Hipercapnia/metabolismo , Síndrome de Dificultad Respiratoria/terapia , Animales , Dióxido de Carbono/metabolismo , Dióxido de Carbono/farmacología , Modelos Animales de Enfermedad , Femenino , Masculino , Intercambio Gaseoso Pulmonar , Conejos , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/metabolismo , Relación Ventilacion-Perfusión/fisiología
10.
J Appl Physiol (1985) ; 100(3): 880-9, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16282431

RESUMEN

Exhaled acetone is measured to estimate exposure or monitor diabetes and congestive heart failure. Interpreting this measurement depends critically on where acetone exchanges in the lung. Health professionals assume exhaled acetone originates from alveolar gas exchange, but experimental data and theoretical predictions suggest that acetone comes predominantly from airway gas exchange. We measured endogenous acetone in the exhaled breath to evaluate acetone exchange in the lung. The acetone concentration in the exhalate of healthy human subjects was measured dynamically with a quadrupole mass spectrometer and was plotted against exhaled volume. Each subject performed a series of breathing maneuvers in which the steady exhaled flow rate was the only variable. Acetone phase III had a positive slope (0.054+/-0.016 liter-1) that was statistically independent of flow rate. Exhaled acetone concentration was normalized by acetone concentration in the alveolar air, as estimated by isothermal rebreathing. Acetone concentration in the rebreathed breath ranged from 0.8 to 2.0 parts per million. Normalized end-exhaled acetone concentration was dependent on flow and was 0.79+/-0.04 and 0.85+/-0.04 for the slow and fast exhalation rates, respectively. A mathematical model of airway and alveolar gas exchange was used to evaluate acetone transport in the lung. By doubling the connective tissue (epithelium+mucosal tissue) thickness, this model predicted accurately (R2=0.94+/-0.05) the experimentally measured expirograms and demonstrated that most acetone exchange occurred in the airways of the lung. Therefore, assays using exhaled acetone measurements need to be reevaluated because they may underestimate blood levels.


Asunto(s)
Acetona/análisis , Espiración , Pulmón/fisiología , Intercambio Gaseoso Pulmonar , Adulto , Simulación por Computador , Femenino , Calor , Humanos , Inhalación/fisiología , Masculino , Espectrometría de Masas , Matemática , Persona de Mediana Edad , Modelos Biológicos , Presión Parcial , Respiración , Pruebas de Función Respiratoria/métodos , Factores de Tiempo
11.
J Appl Physiol (1985) ; 98(6): 2242-8, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15705726

RESUMEN

Vascular infusions of 15-microm-diameter microspheres are used to study pulmonary blood flow distribution. The sites of microsphere lodging and their effects on microvascular perfusion are debated but unknown. Using intravital microscopy of the subpleural surface of rat lungs, we directly observed deposition of fluorescent microspheres. In a pump-perfused lung model, approximately 0.5 million microspheres were infused over 30 s into the pulmonary artery of seven rats. Microsphere lodging was analyzed for the location in the microvasculature and the effect on local flow after lodging. On average, we observed 3.2 microspheres per 160 alveolar facets. The microspheres always entered the arterioles as singlets and lodged at the inlets to capillaries, either in alveolar corner vessels or small arterioles. In all cases, blood flow continued either around the microspheres or into the capillaries via adjacent pathways. We conclude that 15-microm-diameter microspheres, in doses in excess of those used in typical studies, have no significant impact on pulmonary capillary blood flow distribution.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Hemorreología/métodos , Interpretación de Imagen Asistida por Computador/métodos , Microcirculación/citología , Microcirculación/fisiología , Microscopía por Video/métodos , Microesferas , Circulación Pulmonar/fisiología , Animales , Artefactos , Hemorreología/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Microfluídica/instrumentación , Microfluídica/métodos , Microscopía por Video/instrumentación , Técnicas de Sonda Molecular , Tamaño de la Partícula , Ratas , Ratas Sprague-Dawley
12.
J Appl Physiol (1985) ; 98(5): 1862-8, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15591291

RESUMEN

We studied the spatial distribution of the abnormal ventilation-perfusion (Va/Q) units in a porcine model of acute pulmonary thromboembolism (APTE), using the fluorescent microsphere (FMS) technique. Four piglets ( approximately 22 kg) were anesthetized and ventilated with room air in the prone position. Each received approximately 20 g of preformed blood clots at time t = 0 min via a large-bore central venous catheter, until the mean pulmonary arterial pressure reached 2.5 times baseline. The distributions of regional Va and blood flow (Q) at five time points (t = -30, -5, 30, 60, 120 min) were mapped by FMS of 10 distinct colors, i.e., aerosolization of 1-mum FMS for labeling Va and intravenous injection of 15-mum FMS for labeling Q. Our results showed that, at t = 30 min following APTE, mean Va/Q (Va/Q = 2.48 +/- 1.12) and Va/Q heterogeneity (log SD Va/Q = 1.76 +/- 0.23) were significantly increased. There were also significant increases in physiological dead space (11.2 +/- 12.7% at 60 min), but the shunt fraction (Va/Q = 0) remained minimal. Cluster analyses showed that the low Va/Q units were mainly seen in the least embolized regions, whereas the high Va/Q units and dead space were found in the peripheral subpleural regions distal to the clots. At 60 and 120 min, there were modest recoveries in the hemodynamics and gas exchange toward baseline. Redistribution pattern was mostly seen in regional Q, whereas Va remained relatively unchanged. We concluded that the hypoxemia seen after APTE could be explained by the mechanical diversion of Q to the less embolized regions because of the vascular obstruction by clots elsewhere. These low Va/Q units created by high flow, rather than low Va, accounted for most of the resultant hypoxemia.


Asunto(s)
Embolia Pulmonar/metabolismo , Intercambio Gaseoso Pulmonar/fisiología , Ventilación Pulmonar/fisiología , Relación Ventilacion-Perfusión/fisiología , Enfermedad Aguda , Animales , Análisis por Conglomerados , Porcinos
13.
J Appl Physiol (1985) ; 96(5): 1894-8, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-14660515

RESUMEN

We have shown previously that inspired CO2 (3-5%) improves ventilation-perfusion (Va/Q) matching but with the consequence of mild arterial hypercapnia and respiratory acidosis. We hypothesized that adding CO2 only late in inspiration to limit its effects to the conducting airways would enhance Va/Q matching and improve oxygenation without arterial hypercapnia. CO2 was added in the latter half of inspiration in a volume aimed to reach a concentration of 5% in the conducting airways throughout the respiratory cycle. Ten mixed-breed dogs were anesthetized and, in a randomized order, ventilated with room air, 5% CO2 throughout inspiration, and CO2 added only to the latter half of inspiration. The multiple inert-gas elimination technique was used to assess Va/Q heterogeneity. Late-inspired CO2 produced only very small changes in arterial pH (7.38 vs. 7.40) and arterial CO2 (40.6 vs. 39.4 Torr). Compared with baseline, late-inspired CO2 significantly improved arterial oxygenation (97.5 vs. 94.2 Torr), decreased the alveolar-arterial Po2 difference (10.4 vs. 15.7 Torr) and decreased the multiple inert-gas elimination technique-derived arterial-alveolar inert gas area difference, a global measurement of Va/Q heterogeneity (0.36 vs. 0.22). These changes were equal to those with 5% CO2 throughout inspiration (arterial Po2, 102.5 Torr; alveolar-arterial Po2 difference, 10.1 Torr; and arterial-alveolar inert gas area difference, 0.21). In conclusion, we have established that the majority of the improvement in gas exchange efficiency with inspired CO2 can be achieved by limiting its application to the conducting airways and does not require systemic acidosis.


Asunto(s)
Acidosis Respiratoria/prevención & control , Dióxido de Carbono/administración & dosificación , Inhalación , Relación Ventilacion-Perfusión/efectos de los fármacos , Administración por Inhalación , Animales , Arterias , Dióxido de Carbono/farmacología , Perros , Relación Dosis-Respuesta a Droga , Gases/sangre , Concentración de Iones de Hidrógeno , Intercambio Gaseoso Pulmonar/efectos de los fármacos , Factores de Tiempo
14.
J Appl Physiol (1985) ; 96(5): 1589-99, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-14698989

RESUMEN

Hypoxic pulmonary vasoconstriction (HPV) serves to maintain optimal gas exchange by decreasing perfusion to hypoxic regions. However, global hypoxia and nonuniform HPV may result in overperfusion of poorly constricted regions leading to local edema seen in high-altitude pulmonary edema. To quantify the spatial distribution of HPV and its response to regional Po2 (Pr(O2)) among small lung regions, five pigs were anesthetized and mechanically ventilated in the supine posture. The animals were ventilated with an inspired O2 fraction (Fi(O2)) of 0.50 and 0.21 and then (in random order) 0.15, 0.12, and 0.09. Regional blood flow (Q) and alveolar ventilation (Va) were measured by using intravenous infusion of 15 microm and inhalation of 1-microm fluorescent microspheres, respectively. Pr(O2) was calculated for each piece at each Fi(O2). Lung pieces differed in their Q response to hypoxia in a manner related to their initial Va/Q with Fi(O2) = 0.21. Reducing Fi(O2) < 0.15 decreased Q to the initially high Va/Q (higher Pr(O2)) regions and forced Q into the low Va/Q (dorsal-caudal) regions. Resistance increased in most lung pieces as Pr(O2) decreased, reaching a maximum resistance when Pr(O2) is between 40 and 50 Torr. Local resistance decreased at PrO2 < 40 Torr. Pieces were statistically clustered with respect to their relative Q response pattern to each Fi(O2). Some clusters were shown to be spatially organized. We conclude that HPV is spatially heterogeneous. The heterogeneity of Q response may be related, in part, to the heterogeneity of baseline Va/Q.


Asunto(s)
Hipoxia/fisiopatología , Circulación Pulmonar , Vasoconstricción , Resistencia de las Vías Respiratorias , Animales , Femenino , Inhalación , Masculino , Microesferas , Oxígeno , Posición Supina , Porcinos , Relación Ventilacion-Perfusión
15.
Respir Physiol Neurobiol ; 144(2-3): 281-94, 2004 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-15556109

RESUMEN

Hypoxic pulmonary vasoconstriction (HPV) is thought to protect gas exchange by decreasing perfusion to hypoxic regions. However, with global hypoxia, non-uniformity in HPV may cause over-perfusion to some regions, leading to high-altitude pulmonary edema. To quantify the spatial distribution of HPV and regional PO2 (PRO2) among small lung regions (approximately 2.0 cm3), five prone beagles (approximately 8.3 kg) were anesthetized and ventilated (PEEP approximately 2 cm H2O) with an F1O2 of 0.21, then 0.50, 0.18, 0.15, and 0.12 in random order. Regional blood perfusion (Q), ventilation (VA) and calculated PRO2 were obtained using iv infusion of 15 microm and inhalation of 1 microm fluorescent microspheres. Lung pieces were clustered by their relative blood flow response to each F1O2. Clusters were shown to be spatially grouped within animals and across animals. Lung piece resistance increased as PRO2 decreased to 60-70 mmHg but dropped at PRO2's < 60mmHg. Regional ventilation changed little with hypoxia. HPV varied more in strength of response, rather than PRO2 response threshold. In initially homogeneous VA/Q lungs, we conclude that HPV response is heterogeneous and spatially clustered.


Asunto(s)
Hipoxia/fisiopatología , Circulación Pulmonar/fisiología , Intercambio Gaseoso Pulmonar/fisiología , Posición Supina/fisiología , Vasoconstricción/fisiología , Análisis de Varianza , Animales , Análisis por Conglomerados , Perros , Femenino , Precondicionamiento Isquémico/métodos , Pulmón/metabolismo , Pulmón/fisiopatología , Masculino , Oxígeno/metabolismo , Flujo Sanguíneo Regional/fisiología , Relación Ventilacion-Perfusión
16.
IEEE Trans Biomed Eng ; 61(1): 119-30, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23955692

RESUMEN

A highly automated method for the segmentation of airways in the serial block-face cryomicrotome images of rat lungs is presented. First, a point inside of the trachea is manually specified. Then, a set of candidate airway centerline points is automatically identified. By utilizing a novel path extraction method, a centerline path between the root of the airway tree and each point in the set of candidate centerline points is obtained. Local disturbances are robustly handled by a novel path extraction approach, which avoids the shortcut problem of standard minimum cost path algorithms. The union of all centerline paths is utilized to generate an initial airway tree structure, and a pruning algorithm is applied to automatically remove erroneous subtrees or branches. Finally, a surface segmentation method is used to obtain the airway lumen. The method was validated on five image volumes of Sprague-Dawley rats. Based on an expert-generated independent standard, an assessment of airway identification and lumen segmentation performance was conducted. The average of airway detection sensitivity was 87.4% with a 95% confidence interval (CI) of (84.9, 88.6)%. A plot of sensitivity as a function of airway radius is provided. The combined estimate of airway detection specificity was 100% with a 95% CI of (99.4, 100)%. The average number and diameter of terminal airway branches was 1179 and 159 µm, respectively. Segmentation results include airways up to 31 generations. The regression intercept and slope of airway radius measurements derived from final segmentations were estimated to be 7.22 µm and 1.005, respectively. The developed approach enables the quantitative studies of physiology and lung diseases in rats, requiring detailed geometric airway models.


Asunto(s)
Criopreservación/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/anatomía & histología , Microtomía/métodos , Animales , Masculino , Fantasmas de Imagen , Ratas , Ratas Sprague-Dawley
17.
PLoS One ; 8(3): e57179, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23520463

RESUMEN

In the current study, we used a canine model of radiation-induced lung injury to test the effect of a single i.v. infusion of 10×10(6)/kg of marrow fibroblasts on the progression of damage following 15 Gy exposure to the right lung. The fibroblasts, designated DS1 cells, are a cloned population of immortalized cells isolated from a primary culture of marrow stromal cells. DS1 cells were infused at week 5 post-irradiation when lung damage was evident by imaging with high-resolution computed tomography (CT). At 13 weeks post-irradiation we found that 4 out of 5 dogs receiving DS1 cells had significantly improved pulmonary function compared to 0 out of 5 control dogs (p = 0.047, Fisher's Exact). Pulmonary function was measured as the single breath diffusion capacity-hematocrit (DLCO-Hct), the total inspiratory capacity (IC), and the total lung capacity (TLC), which differed significantly between control and DS1-treated dogs; p = 0.002, p = 0.005, and p = 0.004, respectively. The DS1-treated dogs also had less pneumonitis detected by CT imaging and an increased number of TTF-1 (thyroid transcription factor 1, NKX2-1) positive cells in the bronchioli and alveoli compared to control dogs. Endothelial-like progenitor cells (ELC) of host origin, detected by colony assays, were found in peripheral blood after DS1 cell infusion. ELC numbers peaked one day after infusion, and were not detectable by 7 days. These data suggest that infusion of marrow fibroblasts stimulates mobilization of ELC, which is associated with a reduction in otherwise progressive radiation-induced lung injury. We hypothesize that these two observations are related, specifically that circulating ELC contribute to increased angiogenesis, which facilitates endogenous lung repair.


Asunto(s)
Células de la Médula Ósea , Bronquiolos/lesiones , Trasplante de Células , Fibroblastos/trasplante , Enfermedades Pulmonares/terapia , Alveolos Pulmonares/lesiones , Traumatismos Experimentales por Radiación/terapia , Animales , Bronquiolos/patología , Línea Celular Transformada , Perros , Femenino , Enfermedades Pulmonares/etiología , Enfermedades Pulmonares/patología , Masculino , Alveolos Pulmonares/patología , Traumatismos Experimentales por Radiación/patología , Células del Estroma/trasplante , Factores de Tiempo
18.
Respir Physiol Neurobiol ; 189(3): 594-606, 2013 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23942308

RESUMEN

Prior studies exploring the spatial distributions of ventilation and perfusion have partitioned the lung into discrete regions not constrained by anatomical boundaries and may blur regional differences in perfusion and ventilation. To characterize the anatomical heterogeneity of regional ventilation and perfusion, we administered fluorescent microspheres to mark regional ventilation and perfusion in five Sprague-Dawley rats and then using highly automated computer algorithms, partitioned the lungs into regions defined by anatomical structures identified in the images. The anatomical regions ranged in size from the near-acinar to the lobar level. Ventilation and perfusion were well correlated at the smallest anatomical level. Perfusion and ventilation heterogeneity were relatively less in rats compared to data previously published in larger animals. The more uniform distributions may be due to a smaller gravitational gradient and/or the fewer number of generations in the distribution trees before reaching the level of gas exchange, making regional matching of ventilation and perfusion less extensive in small animals.


Asunto(s)
Pulmón/anatomía & histología , Pulmón/irrigación sanguínea , Circulación Pulmonar/fisiología , Mecánica Respiratoria/fisiología , Animales , Colorantes Fluorescentes , Procesamiento de Imagen Asistido por Computador , Pulmón/fisiología , Masculino , Microesferas , Modelos Anatómicos , Intercambio Gaseoso Pulmonar , Ratas , Ratas Sprague-Dawley , Flujo Sanguíneo Regional , Relación Ventilacion-Perfusión
19.
Pulm Circ ; 2(1): 67-74, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22558522

RESUMEN

We aimed to investigate the role of endothelin-mediated vasoconstriction following acute pulmonary thromboembolism (APTE). Thirteen anesthetized piglets (~25 kg) were ventilated with 0 PEEP. Cardiac output (Qt) and wedge pressure (Pw) were measured by a Swan Ganz catheter, along with arterial and venous blood gases. APTE was induced by autologous blood clots (~0.8 g/kg, 12-16 pieces) via a jugular venous catheter at time = 0 minutes until the mean pulmonary arterial pressure (Ppa) was about 2.5 times the baseline at 30 minutes. Eight control animals (Group 1) received only normal saline afterward, while the remaining five (Group 2) received at time = 40-minute saline plus Tezosentan, a nonspecific endothelin antagonist. The drug was initially given as an intravenous bolus (10 mg/kg), followed by an infusion (2 mg/min) until the end of the experiment at 2 hours. Hemodynamic data were measured before APTE and then at 30-minute intervals. Pulmonary vascular resistance index (PVRI) was calculated as (Ppa-Pw)/CI, where CI was cardiac index or Qt/W (body weight). Fluorescent microspheres (FMS) were used to mark regional blood flows and ventilation for cluster analysis. PVRI acutely increased within minutes and remained high despite some recovery over time. With Tezosentan treatment, the results showed that endothelin-mediated vasoconstriction persisted significantly up to 2 hours and accounted for about 25% of the increase in PVRI while clot obstruction accounted for the remaining 75%. CI remained relatively constant throughout. Tezosentan also affected PVRI indirectly by mitigating the shift of regional blood flow back to the embolized areas over time, possibly by attenuating vasoconstriction in the nonembolized areas. We conclude that following APTE, although the increased PVRI is mostly due to mechanical embolic obstruction, secondary factors such as vasoconstriction and pattern of regional blood flow over time also play important roles.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA