Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Blood ; 130(4): 466-471, 2017 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-28576877

RESUMEN

Immune-mediated thrombotic thrombocytopenic purpura (TTP) is a life-threatening disorder caused by antibodies against ADAMTS13. From the United Kingdom TTP registry, we undertook a prospective study investigating the impact of the presenting anti-ADAMTS13 IgG antibody and ADAMTS13 antigen on mortality. A total of 312 episodes involving 292 patients over 87 months were included; 68% were female, median age 46 (range, 11-88 years), and median presenting ADAMTS13 of <5% (range, <5%-18%). The mortality rate was 10.3% (n = 32); 68% of patients had a raised troponin at presentation conferring a sixfold increase in mortality compared with those with normal troponin levels (12.1% vs 2.0%, P = .04). Twenty-four percent had a reduced Glasgow Coma Score (GCS) at presentation with a ninefold increase in mortality (20% vs 2.2% for normal GCS at presentation, P < .0001). Mortality increased with higher anti-ADAMTS13 antibody levels and lower ADAMTS13 antigen levels. Those with antibody levels in the upper quartile (antibody >77%) had a mortality of 16.9% compared with 5.0% for the lowest quartile (antibody <20%) (P = .004). Those with an antigen level in the lowest quartile (antigen <1.5%) had a mortality of 18% compared with 3.8% for the highest quartile (antigen >11%) (P = .005). The synergistic effect of anti-ADAMTS13 IgG antibody in the upper quartile and ADAMTS13 antigen in the lowest quartile had the highest mortality of 27.3%. We conclude that both anti-ADAMTS13 IgG antibody and ADAMTS13 antigen levels correlate with outcome in TTP with increased cardiac and neurological involvement and increased mortality.


Asunto(s)
Proteína ADAMTS13 , Autoanticuerpos , Inmunoglobulina G , Púrpura Trombocitopénica Trombótica , Proteína ADAMTS13/sangre , Proteína ADAMTS13/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Autoanticuerpos/sangre , Autoanticuerpos/inmunología , Niño , Supervivencia sin Enfermedad , Femenino , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Púrpura Trombocitopénica Trombótica/sangre , Púrpura Trombocitopénica Trombótica/inmunología , Púrpura Trombocitopénica Trombótica/mortalidad , Tasa de Supervivencia
2.
Int J Lab Hematol ; 42(5): 643-649, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32885901

RESUMEN

BACKGROUND: The CN-6000 (Sysmex Corp.) is a new haemostasis analyser with blood coagulation, amidolytic, immuno-turbidometric and light transmission aggregometry (LTA) capabilities. Transmitted light is monitored at multiple wavelengths (340, 405, 575, 660, 800 nm), from an LED light source. AIMS: To evaluate the performance of the CN-6000 against a predicate device. METHODS: The CN-6000 was evaluated against the CS-5100 (Sysmex) for 14 different tests, using 880 samples from normal subjects, anticoagulated patients, critically ill patients, plasmas with high or low fibrinogen content or abnormal levels of interfering substances. Between-day assay imprecision was assessed using commercial QC materials (n = 10 replicates on each of 5 days). RESULTS: Acceptable levels of imprecision were obtained for all assays. Agreement between the two analysers was excellent for all assays. Throughput was 35% higher using the CN-6000 (337 vs 250 tests per hour for PT, aPTT and fibrinogen). The CN-6000 also demonstrated improved clot detection in plasmas with high levels of interfering substances as demonstrated by a 29% reduction in "vote-outs" due to low light transmission (24 vs 34). CONCLUSIONS: The CN-6000 demonstrated excellent comparability with the predicate instrument and acceptable levels of imprecision in all assays. Improvements in throughput and clot detection in the presence of interfering substances were also shown.


Asunto(s)
Pruebas de Coagulación Sanguínea/instrumentación , Pruebas de Coagulación Sanguínea/métodos , Coagulación Sanguínea , Pruebas de Coagulación Sanguínea/normas , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Thromb Haemost ; 109(3): 488-96, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23306535

RESUMEN

ADAMTS13 activity assays are sometimes useful in confirming the clinical diagnosis or to distinguish different thrombotic microangiopathies (TMA). We investigated the commonly used clinical assays for ADAMTS13 activity. 159 samples from normal subjects or acquired TMA patients were studied in collagen binding (CBA), Fret and chromogenic peptide substrate assays. Frozen aliquots of pooled normal plasma gave similar values by CBA, Fret-VWF73 peptide, Fret-VWF86 and chromogenic VWF73 ELISA (chr-VWF73). Two lyophilised commercial calibrants gave lower ADAMTS13 activity by CBA than peptide substrate assays. The addition of solid HEPES to normal plasma caused a significant fall in CBA, but not Fret-VWF73 activity and might partly explain the differences, since lyophilised plasmas are often HEPES buffered. Normal plasmas showed good agreement between CBA and Fret assays, although chr-VWF73 gave slightly higher values. In acquired TMA, there was reasonable agreement between assays for samples with <11% ADAMTS13 activity (83% of samples showed agreement between CBA, Fret-VWF73 and chr-VWF73), but samples with moderate deficiency frequently showed lower CBA levels (only 41-52% agreement). However, there were also some discrepancies among the peptide substrate assays, with Fret-VWF86 sometimes giving slightly higher values than the VWF73 substrate assays. An International reference plasma might improve standardisation, but is not the only problem. It is unclear which assay has greatest clinical utility, this may depend on the nature of the sample. If the activity does not match the clinical picture, an alternative method should be performed. Where therapeutic monitoring is required, the same activity assay should be used throughout.


Asunto(s)
Proteínas ADAM/química , Pruebas Hematológicas/métodos , Microangiopatías Trombóticas/sangre , Proteína ADAMTS13 , Calibración , Colágeno/química , Transferencia Resonante de Energía de Fluorescencia , Pruebas Hematológicas/normas , Hemoglobinas/química , Síndrome Hemolítico-Urémico/sangre , Humanos , Péptidos/química , Unión Proteica , Púrpura Trombocitopénica Trombótica/sangre , Control de Calidad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA