Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
2.
J Synchrotron Radiat ; 29(Pt 2): 581-590, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35254323

RESUMEN

ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s-1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.


Asunto(s)
Lentes , Sincrotrones , Cristalografía por Rayos X , Recolección de Datos , Sustancias Macromoleculares/química
3.
J Synchrotron Radiat ; 19(Pt 3): 455-61, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22514185

RESUMEN

ID29 is an ESRF undulator beamline with a routinely accessible energy range of between 20.0 keV and 6.0 keV (λ = 0.62 Što 2.07 Å) dedicated to the use of anomalous dispersion techniques in macromolecular crystallography. Since the beamline was first commissioned in 2001, ID29 has, in order to provide an improved service to both its academic and proprietary users, been the subject of almost continuous upgrade and refurbishment. It is now also the home to the ESRF Cryobench facility, ID29S. Here, the current status of the beamline is described and plans for its future are briefly outlined.


Asunto(s)
Sustancias Macromoleculares/química , Sincrotrones/instrumentación , Tripsina/química , Difracción de Rayos X
4.
J Synchrotron Radiat ; 17(5): 700-7, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20724792

RESUMEN

The design and features of a beamline control software system for macromolecular crystallography (MX) experiments developed at the European Synchrotron Radiation Facility (ESRF) are described. This system, MxCuBE, allows users to easily and simply interact with beamline hardware components and provides automated routines for common tasks in the operation of a synchrotron beamline dedicated to experiments in MX. Additional functionality is provided through intuitive interfaces that enable the assessment of the diffraction characteristics of samples, experiment planning, automatic data collection and the on-line collection and analysis of X-ray emission spectra. The software can be run in a tandem client-server mode that allows for remote control and relevant experimental parameters and results are automatically logged in a relational database, ISPyB. MxCuBE is modular, flexible and extensible and is currently deployed on eight macromolecular crystallography beamlines at the ESRF. Additionally, the software is installed at MAX-lab beamline I911-3 and at BESSY beamline BL14.1.


Asunto(s)
Cristalografía por Rayos X/métodos , Programas Informáticos , Sincrotrones , Hidrolasas de Éster Carboxílico/química , Bases de Datos Factuales , Sustancias Macromoleculares/química , Espectrometría por Rayos X , Termolisina/química
5.
Acta Crystallogr D Biol Crystallogr ; 65(Pt 12): 1237-46, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19966409

RESUMEN

Dehydration of protein crystals is rarely used, despite being a post-crystallization method that is useful for the improvement of crystal diffraction properties, as it is difficult to reproduce and monitor. A novel device for hydration control of macromolecular crystals in a standard data-collection environment has been developed. The device delivers an air stream of precise relative humidity that can be used to alter the amount of water in macromolecular crystals. The device can be rapidly installed and is fully compatible with most standard synchrotron X-ray beamlines. Samples are mounted in cryoloops and the progress of dehydration can be monitored both optically and by the acquisition of diffraction images. Once the optimal hydration level has been obtained, cryocooling is easy to achieve by hand or by using a sample changer. The device has been thoroughly tested on several ESRF beamlines and is available to users.


Asunto(s)
Proteínas/análisis , Difracción de Rayos X/instrumentación , Difracción de Rayos X/métodos , Animales , Pollos , Cristalización , Escherichia coli/química , Modelos Moleculares , Estructura Terciaria de Proteína , Proteínas/química , Agua/química
6.
Prog Biophys Mol Biol ; 89(2): 124-52, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15910915

RESUMEN

The production of three-dimensional crystallographic structural information of macromolecules can now be thought of as a pipeline which is being streamlined at every stage from protein cloning, expression and purification, through crystallisation to data collection and structure solution. Synchrotron X-ray beamlines are a key section of this pipeline as it is at these that the X-ray diffraction data that ultimately leads to the elucidation of macromolecular structures are collected. The burgeoning number of macromolecular crystallography (MX) beamlines available worldwide may be enhanced significantly with the automation of both their operation and of the experiments carried out on them. This paper reviews the current situation and provides a glimpse of how a MX beamline may look in the not too distant future.


Asunto(s)
Cristalografía por Rayos X , Proteínas/química , Programas Informáticos , Conformación Proteica , Análisis Espectral/instrumentación , Análisis Espectral/métodos , Sincrotrones/instrumentación
7.
Acta Crystallogr D Biol Crystallogr ; 62(Pt 11): 1348-57, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17057338

RESUMEN

A method is presented to automatically locate a crystal and its holder for centring on a goniometer spindle and alignment with an X-ray beam. Here, a novel algorithm that has been developed and tested with the images of users' crystals saved in an annotated database is described. The algorithm improves on the difficult situations that are commonly observed and poorly handled by the first-generation crystal-centring algorithms. These include highly transparent crystals, bad cryocooling or lens effects arising from the geometry of the drop. Most crystals have polyhedral shapes and a number of straight edges, which yield useful information. In this method, crystal detection relies on a feature-scoring system in which line extraction has the highest weight. Here, the image processing and calculations implemented in the program C3D are described. This program is designed to operate with a client program that controls specific diffractometer hardware. In order to select the best detection conditions, C3D provides various functionalities adapted to various hardware configurations.


Asunto(s)
Automatización , Programas Informáticos , Automatización/métodos , Cristalografía por Rayos X/métodos
8.
Acta Crystallogr D Biol Crystallogr ; 62(Pt 3): 253-61, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16510972

RESUMEN

Structural proteomics has promoted the rapid development of automated protein structure determination using X-ray crystallography. Robotics are now routinely used along the pipeline from genes to protein structures. However, a bottleneck still remains. At synchrotron beamlines, the success rate of automated sample alignment along the X-ray beam is limited by difficulties in visualization of protein crystals, especially when they are small and embedded in mother liquor. Despite considerable improvement in optical microscopes, the use of visible light transmitted or reflected by the sample may result in poor or misleading contrast. Here, the endogenous fluorescence from aromatic amino acids has been used to identify even tiny or weakly fluorescent crystals with a high success rate. The use of a compact laser at 266 nm in combination with non-fluorescent sample holders provides an efficient solution to collect high-contrast fluorescence images in a few milliseconds and using standard camera optics. The best image quality was obtained with direct illumination through a viewing system coaxial with the UV beam. Crystallographic data suggest that the employed UV exposures do not generate detectable structural damage.


Asunto(s)
Proteínas/química , Cristalización , Cristalografía , Fluorescencia , Insulina/química , Rayos Láser , Muramidasa/química , Rayos Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA