Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Hand Surg Am ; 48(3): 283-291, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36509592

RESUMEN

Acute disruptions of the terminal extensor tendon are common and can result in significant dysfunction if not recognized and treated appropriately. This article provides a topical review of the contemporary literature concerning acute mallet finger injuries. It also proposes a modification to the Doyle classification to make it more encompassing and less prone to interobserver error.


Asunto(s)
Artritis , Traumatismos de los Dedos , Deformidades Adquiridas de la Mano , Traumatismos de los Tendones , Humanos , Traumatismos de los Dedos/terapia , Traumatismos de los Tendones/terapia , Tendones , Deformidades Adquiridas de la Mano/terapia
2.
J Reconstr Microsurg ; 38(8): 593-603, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34905783

RESUMEN

BACKGROUND: The free medial femoral condyle (MFC) bone flap is an attractive option for reconstruction of scaphoid nonunion utilizing vascularized bone to augment bony healing, especially in cases of failed prior treatment or osteonecrosis. This review aims to determine the role and reliability of the free MFC flap for treatment of scaphoid nonunion. METHODS: A search of electronic databases was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Articles examining free MFC bone flaps for treatment of scaphoid nonunion were included for analysis. Outcomes of interest included flap failure, postoperative union rate, time to union, carpal indices, functional outcomes, and complications. RESULTS: Twelve articles met the inclusion criteria. A total of 262 patients underwent free MFC flaps for treatment of scaphoid nonunion. The most common site of nonunion was the proximal pole of the scaphoid with 47% of patients receiving prior attempts at operative management. Overall bony union rate was 93.4% with a mean time to union of 15.6 weeks. There were no flap failures reported. Improvements in carpal indices including scapholunate (p < 0.0004), radiolunate (p < 0.004), lateral interscaphoid angles (p < 0.035), and revised carpal ratio height (p < 0.024) were seen postoperatively. Visual analog scale improved postoperatively from 6.5 to 2.3 (p < 0.015). Postoperative complications were observed in 69 cases (26.3%), with 27 patients (10.3%) requiring further operative intervention. However, no major donor or recipient site morbidity was appreciated. CONCLUSION: MFC flaps provide a highly versatile and reliable option for reconstruction of scaphoid nonunion with excellent bony union rates and acceptable complication rates. The present literature suggests that MFC reconstruction of scaphoid nonunion restores radiocarpal anatomy and improves wrist function without causing significant donor or recipient site morbidity.


Asunto(s)
Fracturas no Consolidadas , Colgajos Tisulares Libres , Hueso Escafoides , Trasplante Óseo , Fracturas no Consolidadas/cirugía , Humanos , Complicaciones Posoperatorias , Reproducibilidad de los Resultados , Estudios Retrospectivos , Hueso Escafoides/cirugía
3.
J Hand Surg Am ; 43(1): 83.e1-83.e6, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28917547

RESUMEN

PURPOSE: To investigate the radiographic length and width of the new thumb metacarpal in relation to the middle finger proximal phalanx; to assess the incidence of premature physeal closure of the new metacarpal; and to consider whether there is a relationship between growth characteristics and the presence of union or nonunion of the new trapezium to the retained index finger metacarpal base. METHODS: Forty pollicizations were assessed with preoperative or immediate postoperative radiographs and follow-up radiographs to establish the growth characteristics of the new thumb metacarpal. Functional outcomes comprising grip strength, pinch strength, and range of motion were correlated with radiological findings of presence or absence of open physes and presence or absence of union of the new trapezium to the metacarpal base. RESULTS: The new thumb metacarpal physis was open in 28 pollicizations and closed in 12. In the latter group, all physes of the hand had closed indicating skeletal maturity. The length and width indices of the new thumb metacarpal in relation to the middle finger proximal phalanx were equivalent to or greater than the perioperative growth indices. There was a reduced postoperative length ratio in those patients with nonunion of the new trapezium to the base of the metacarpal. There was no change in strength and range of motion parameters with growth other than that related to normal improvement with age. CONCLUSIONS: We are unable to demonstrate premature physeal closure following routine pollicization. The growth of the metacarpal continues in a normal manner to skeletal maturity. A failure of union of the new trapezium to the metacarpal base may compromise growth. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Asunto(s)
Deformidades Congénitas de la Mano/cirugía , Huesos del Metacarpo/crecimiento & desarrollo , Huesos del Metacarpo/trasplante , Pulgar/anomalías , Pulgar/cirugía , Adolescente , Niño , Preescolar , Diáfisis/crecimiento & desarrollo , Diáfisis/cirugía , Femenino , Deformidades Congénitas de la Mano/diagnóstico por imagen , Fuerza de la Mano , Humanos , Lactante , Masculino , Huesos del Metacarpo/diagnóstico por imagen , Rango del Movimiento Articular , Adulto Joven
4.
J Hand Surg Am ; 43(2): 139-145, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29137829

RESUMEN

PURPOSE: This study investigates the loss of compression when 3 commonly used headless compression screws are backed out (reversed), and assesses the ability to re-establish compression with screws of greater diameter. METHODS: Two investigators tested 3 screw designs (Acutrak 2, Synthes HCS, Medartis SpeedTip CCS) in 2 diameters and lengths. Each design had 10 test cycles in a polyurethane foam bone model with compression recorded using a washer load cell. A 28-mm screw of the narrower diameter was inserted until 2 mm recessed and then reversed 30°, 60°, 90°, 180°, 270°, 360°, and 720°. After this the screw was removed completely and a 24-mm screw of greater diameter inserted until recessed 2 mm with the compressive force again recorded. RESULTS: All screws showed an immediate, statistically significant loss of compression at 30° of reversing. The Acutrak 2 Micro screw demonstrated not only the greatest mean compressive force, but also the fastest compressive loss. Insertion of the shorter screw of greater diameter was associated with re-establishment of compression to levels comparable with the original screw. CONCLUSIONS: This study reaffirms the importance of establishing the correct screw length before insertion due to the immediate loss of compression with reversal of these devices. CLINICAL RELEVANCE: If a headless compression screw penetrates the far joint surface, the screw should be completely removed and replaced with a shorter screw of greater diameter.


Asunto(s)
Tornillos Óseos , Fuerza Compresiva , Diseño de Prótesis , Falla de Prótesis , Fijación Interna de Fracturas/instrumentación , Humanos , Modelos Biológicos
5.
J Hand Surg Am ; 40(7): 1318-26, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26095054

RESUMEN

PURPOSE: To investigate the presence or absence of union of the new trapezium to the retained metacarpal base after pollicization and to relate this to stability of the new trapezium and the new carpometacarpal joint. METHODS: Thirty-six patients (46 pollicizations) were assessed at clinical review. Mean time from surgery to review was 96 months (range, 9-260 mo). Clinical assessment measured range of motion (ROM) at the carpometacarpal joint, stability of the carpometacarpal joint, and extrinsic and intrinsic strength of both hands. Radiological review evaluated 3 parameters: bony union between the new trapezium and retained metacarpal base, stability of the new trapezium in relationship to the metacarpal base, and carpometacarpal joint stability. RESULTS: There was radiographic nonunion between the new trapezium and the retained metacarpal base in 8 (1 treated) of 46 pollicizations. Relative risk of instability of the new trapezium was 39 times more likely if nonunion was present. Nine pollicizations were unstable at the carpometacarpal joint, 8 in those with union and 1 with nonunion. Relative risk of instability was 1.4 times more likely for those with union. For patients with nonunion, ROM and grip strength variables were reduced but only grip strength reached statistical significance. In patients with carpometacarpal joint instability, ROM and grip strength variables were reduced but none of the variables reached statistical significance. CONCLUSIONS: This study suggests that when the surgeon is attempting to obtain union of the new trapezium to the retained metacarpal base, failure to do so results in a poorer thumb with a significantly increased risk of trapezial instability and decreased grip strength. There is a mildly increased risk of carpometacarpal joint instability with union, but significantly poorer function as a consequence of this has not been demonstrated. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Asunto(s)
Articulaciones Carpometacarpianas/anomalías , Articulaciones Carpometacarpianas/cirugía , Inestabilidad de la Articulación/fisiopatología , Pulgar/anomalías , Hueso Trapecio/cirugía , Adolescente , Articulaciones Carpometacarpianas/diagnóstico por imagen , Niño , Preescolar , Femenino , Fuerza de la Mano/fisiología , Humanos , Lactante , Inestabilidad de la Articulación/diagnóstico por imagen , Masculino , Radiografía , Rango del Movimiento Articular/fisiología , Hueso Trapecio/anomalías , Hueso Trapecio/diagnóstico por imagen , Resultado del Tratamiento
6.
J Hand Surg Am ; 40(3): 456-61, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25617216

RESUMEN

PURPOSE: To describe 2 simple objective clinical methods of measuring the web position between fingers and to determine their intra-observer and inter-observer reliabilities. METHODS: Two observers examined the second, third, and fourth web spaces on both hands of 30 adult healthy volunteers. The web index measured the web height as a relative ratio to constant anatomical landmarks on both fingers subtending the web. The dorsal web index took reference from the distance between the metacarpophalangeal and proximal interphalangeal joints, whereas the palmar web index was measured in relation to the distance between the most proximal basal digital and proximal interphalangeal joint creases. The intraclass correlation coefficient was used to determine intra-observer and inter-observer reliability. RESULTS: Intraclass correlation coefficient values for intra-observer and inter-observer reliability were greater than 0.80, indicating excellent agreement. There was no statistically significant difference between the dorsal or palmar measurement methods in terms of reliability. CONCLUSIONS: The dorsal or palmar measurement method may be reliably used in healthy adults to establish a web index that describes the web position. The palmar method is considered easier to perform. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic III.


Asunto(s)
Dedos/anatomía & histología , Mano/anatomía & histología , Adulto , Anciano , Estudios de Cohortes , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Sindactilia/diagnóstico , Adulto Joven
7.
Med J Aust ; 199(7): 491-2, 2013 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-24099211

RESUMEN

OBJECTIVES: To conduct a database search, chart and literature review of open extensor tendon and proximal interphalangeal joint injuries incurred while handling mobile garbage bins. DESIGN, SETTING AND PARTICIPANTS: A review of medical records at a Sydney tertiary referral hospital and a NSW rural Level 2 trauma hospital from 1 January 2006 to 31 December 2010, identified through database searches of appropriate medical record codes and followed by a chart review. RESULTS: We identified 11 patients with finger injuries from handling mobile garbage bins that necessitated hospital-based treatments. Their average age was 75 years. Eight patients required surgery. Patients typically fell while maintaining their grip on mobile garbage bin handles, causing abrasive injury to the dorsal aspect of the proximal interphalangeal joint. CONCLUSIONS: Older patients are at risk of significant injuries to the dorsal side of their fingers when manoeuvring mobile garbage bins. This risk could be reduced by providing older members of the community with help to move their bins, or by modifying the design of bin handles. We propose a simple modification to the design of bin handles.


Asunto(s)
Residuos de Alimentos , Traumatismos de la Mano/etiología , Artículos Domésticos , Anciano , Anciano de 80 o más Años , Traumatismos de los Dedos/epidemiología , Traumatismos de los Dedos/etiología , Traumatismos de la Mano/epidemiología , Humanos , Nueva Gales del Sur/epidemiología , Estudios Retrospectivos
9.
J Hand Surg Am ; 38(9): 1845-53, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23684520

RESUMEN

The Oberg, Manske, and Tonkin (OMT) classification of congenital hand and upper limb anomalies was proposed in 2010 as a replacement for the Swanson International Federation of Societies for Surgery of the Hand classification system, which has been the accepted system of classification for the international surgical community since 1976. The OMT system separates malformations from deformations and dysplasias. Malformations are subdivided according to the axis of formation and differentiation that is primarily affected and whether the anomalies involve the whole limb or the hand plate. This review outlines the development of classification systems and explores the difficulty of incorporating our current knowledge of limb embryogenesis at a molecular level into current systems. An assessment of the efficacy of the OMT classification demonstrates acceptable inter- and intraobserver reliability. A prospective review of 101 patients confirms that all diagnoses could be classified within the OMT system. Consensus expert opinion allowed classification of those conditions for which there is not a clear understanding of the mechanism of dysmorphology. A refined and expanded OMT classification is presented.


Asunto(s)
Deformidades Congénitas de la Mano/clasificación , Deformidades Congénitas de las Extremidades Superiores/clasificación , Desarrollo Embrionario , Humanos , Encuestas y Cuestionarios
10.
Hand (N Y) ; 18(2): 264-271, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-33834891

RESUMEN

BACKGROUND: Reverse homodigital island flaps (RHIFs) are increasingly used to reconstruct traumatic fingertip injuries, but there is limited evidence on the efficacy of this technique. We performed a systematic review of the literature to establish the safety and functional outcomes of RHIF for traumatic fingertip injuries. METHODS: Electronic searches were performed using 3 databases (PubMed, Ovid Medline, Cochrane CENTRAL) from their date of inception to April 2020. Relevant studies were required to report on complications and functional outcomes for patients undergoing RHIF for primary fingertip reconstruction. Data were extracted from included studies and analyzed. RESULTS: Sixteen studies were included, which produced a total cohort of 459 patients with 495 fingertip injuries. The index and middle fingers were involved most frequently (34.6% and 34.1%, respectively), followed by the ring finger (22%), the little finger (6.7%), and the thumb (2.6%). The mean postoperative static and moving 2-point discrimination was 7.2 and 6.7 mm, respectively. The mean time to return to work was 8.4 weeks. The mean survivorship was 98.4%, with the pooled complication rate being 28%. The pooled complication rate of complete flap necrosis was 3.6%, of partial flap necrosis was 10.3%, of venous congestion was 14.6%, of pain or hypersensitivity was 11.5%, of wound infection was 7.2%, of flexion contractures was 6.3%, and of cold intolerance was 17.7%. CONCLUSIONS: Reverse homodigital island flaps can be performed safely with excellent outcomes. To minimize complications, care is taken during dissection and insetting, with extensive rehabilitation adhered to postoperatively. Prospective studies assessing outcomes of RHIF compared with other reconstruction techniques would be beneficial.


Asunto(s)
Traumatismos de los Dedos , Humanos , Estudios Prospectivos , Traumatismos de los Dedos/cirugía , Colgajos Quirúrgicos , Dedos/cirugía , Necrosis
11.
Hand (N Y) ; 18(2): 300-306, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-34098748

RESUMEN

Intra-articular fracture dislocations of the base of the middle phalanx are complex and debilitating injuries that present a management conundrum when nonreconstructable. Hemi-hamate arthroplasty (HHA) is a treatment modality of particular use in the setting of highly comminuted fractures. This systematic review aims to summarize the reported outcomes of HHA in this context. A literature search was conducted using MEDLINE, Embase, and PubMed, yielding 22 studies with 235 patients for inclusion. The weighted mean postoperative range of movement at the proximal interphalangeal joint was 74.3° (range, 62.0°-96.0°) and at the distal interphalangeal joint was 57.0° (range, 14.0°-80.4°). The weighted mean postoperative pain Visual Analog Scale was 1.0 (range, 0.0-2.0). The weighted mean postoperative grip strength was 87.1% (range, 74.5%-95.0%) of the strength on the contralateral side. Posttraumatic arthritis was reported in 18% of cases, graft collapse in 4.2%, and donor site morbidity in 3.0%, with a mean follow-up period of 28.4 months (range, 1-87 months). Hemi-hamate arthroplasty is a reliable and effective technique for the reconstruction of intra-articular base of middle phalangeal fracture dislocations, affording symptomatic relief and functional restoration. Further research is required to assess the true incidence of long-term complications.


Asunto(s)
Traumatismos del Brazo , Traumatismos de los Dedos , Fracturas Óseas , Hueso Ganchoso , Hemiartroplastia , Luxaciones Articulares , Humanos , Articulaciones de los Dedos/cirugía , Fracturas Óseas/complicaciones , Hueso Ganchoso/lesiones , Traumatismos de los Dedos/cirugía , Traumatismos del Brazo/cirugía , Luxaciones Articulares/cirugía
12.
Hand (N Y) ; 18(1): 74-79, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-33682483

RESUMEN

Proximal interphalangeal joint (PIPJ) arthrodesis is a salvage option in the management of end-stage PIPJ arthropathy. Numerous techniques have been described, including screws, Kirschner wires, tension band wiring, intramedullary devices, and plate fixation. There remains no consensus as to the optimum method, and no recent summary of the literature exists. A literature search was conducted using the MEDLINE, EMBASE, and PubMed databases. English-language articles reporting PIPJ arthrodesis outcomes were included and presented in a systematic review. Pearson χ2 and 2-sample proportion tests were used to compare fusion time, nonunion rate, and complication rate between arthrodesis techniques. The mean fusion time ranged from 5.1 to 12.9 weeks. There were no statistically significant differences in fusion time between arthrodesis techniques. Nonunion rates ranged from 0.0% to 33.3%. Screw arthrodesis demonstrated a lower nonunion rate than wire fusion (3.0% and 8.5% respectively; P = .01). Complication rates ranged from 0.0% to 22.1%. Aside from nonunions, there were no statistically significant differences in complication rates between arthrodesis techniques. The available PIPJ arthrodesis techniques have similar fusion time, nonunion rate, and complication rate outcomes. The existing data have significant limitations, and further research would be beneficial to elucidate any differences between techniques.


Asunto(s)
Hilos Ortopédicos , Artropatías , Humanos , Tornillos Óseos , Artrodesis/métodos , Articulaciones de los Dedos/cirugía
13.
Hand (N Y) ; 18(2): 355-361, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-34308714

RESUMEN

BACKGROUND: The Coronavirus Disease 2019 (COVID-19) pandemic has had a dramatic impact on individual and societal behaviors, as well as on health care systems. It confers a unique opportunity to examine the relationship among disease, policies, and patterns of activity, as well as their impacts on surgical unit functionality. This study aims to compare the distribution and patterns of injury at a tertiary hand surgery trauma center before and during the COVID-19 pandemic. METHODS: A retrospective analysis of all patients presenting to the Royal North Shore Hospital hand surgery service in the 5-week period from March 16 to April 21 in 2019 and 2020 was undertaken, forming 2 cohorts for comparison. Demographic, injury, and operative data were collected and compared descriptively using comparative statistics. RESULTS: There were 114 primary operative presentations during the 5-week period in 2020, representing a 27.4% decrease from the 157 presentations during the equivalent period in 2019. There was an increase in the proportion of emergency presentations from 73.9% in 2019 to 85.1% in 2020 (P = .03), with a corresponding decrease in elective presentations during 2020. The incidence of sporting injuries and motor vehicle accidents decreased in 2020, whereas falls and accidents involving knives and tools remained relatively constant. Operating times decreased in 2020, whereas the length of hospital stay remained constant. CONCLUSIONS: The COVID-19 pandemic and consequent restrictions of activity have had substantial impacts on the patterns of hand trauma and its management. These insights have implications for staff and resource management during times of social disruption in the future.


Asunto(s)
COVID-19 , Traumatismos de la Mano , Humanos , COVID-19/epidemiología , SARS-CoV-2 , Pandemias , Estudios Retrospectivos , Centros Traumatológicos , Traumatismos de la Mano/epidemiología , Traumatismos de la Mano/cirugía
14.
Hand (N Y) ; 18(6): 978-986, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-35179060

RESUMEN

BACKGROUND: Compared to the traditional open carpal tunnel release (OCTR), the additional safety and efficacy benefits of endoscopic carpal tunnel release (ECTR) remains unclear. The aim of this study is to evaluate the outcomes of ECTR versus conventional OCTR as well as determine if a difference exists between the 2 most common endoscopic techniques: the single-portal and the dual-portal endoscopic technique. METHODS: We conducted a systematic literature search of Medline, Embase, PubMed, and the CENTRAL. Additional articles were identified by handsearching reference lists. We included all randomized controlled trials that compared outcomes of ECTR with OCTR technique. Outcomes assessed included length of surgery, patient reported symptom and functional measures, time to return to work, and complications. A sub-group analysis was performed to indirectly compare single- versus dual-portal endoscopic approaches. Statistical analysis was performed via a random-effects model using Review Manager 5 Software. RESULTS: A meta-analysis of 23 studies revealed a significantly higher incidence of transient postoperative nerve injury with ECTR, regardless of the number of portals, as compared with OCTR, although overall complication and re-operation rates were equivalent. Scar tenderness was significantly diminished with dual-portal endoscopic release when compared to single-portal and open methods. The rates of pillar pain, symptom relief, and patient reported satisfaction did not differ significantly between treatment groups. CONCLUSIONS: Although endoscopic surgery may be appealing in terms of reduced postoperative morbidity and a faster return to work for patients, surgeons should be mindful of the associated learning curve and higher incidence of transient nerve injury. Further study is required to identify if an advantage exists between different endoscopic techniques.


Asunto(s)
Síndrome del Túnel Carpiano , Endoscopía , Humanos , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Endoscopía/métodos , Procedimientos Neuroquirúrgicos/métodos , Síndrome del Túnel Carpiano/cirugía
15.
J Hand Surg Asian Pac Vol ; 27(4): 732-735, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35965358

RESUMEN

Trigger digit is a common condition which is largely idiopathic in etiology. Less frequently, it has been described secondary to anatomical variations or space occupying lesions. We describe a patient who developed a recurrent trigger finger after a surgical release of the first annular pulley. Intraoperatively, the trigger was noted to be caused by herniation of the flexor digitorum profundus (FDP) tendon into a noose formed by the two slips of the flexor digitorum superficialis tendon (FDS) and the proximal edge of the second annular pulley. Level of Evidence: Level V (Therapeutic).


Asunto(s)
Trastorno del Dedo en Gatillo , Fenómenos Biomecánicos , Mano , Humanos , Músculo Esquelético , Tendones/diagnóstico por imagen , Tendones/cirugía , Trastorno del Dedo en Gatillo/etiología , Trastorno del Dedo en Gatillo/cirugía
16.
Hand (N Y) ; : 15589447221084010, 2022 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-35321571

RESUMEN

The one-bone forearm (OBF) is a salvage technique that may be used to correct global forearm instability secondary to osseous defects. This study aims to provide an overview of the contemporary literature regarding the OBF. A literature review was conducted electronically across MEDLINE, Embase, and PubMed databases in May 2020. Studies were eligible for inclusion if published in the English language; detailed the use of the OBF procedure to correct forearm instability; and were original data studies reporting qualitative or quantitative outcomes. Thirty-four studies, describing a cohort of 210 patients undergoing 211 OBFs, were documented in the literature. The primary etiology necessitating the OBF was trauma, followed by genetic/congenital disorders and infections. Technically, the OBF was most frequently achieved via an end-to-end osteosynthesis with plate fixation. In total, 85.0% (154/182) of OBF were fused in neutral rotation or varying degrees of pronation. Union was achieved in more than 80.0% (174/211) of OBFs. The OBF is a feasible salvage technique that has been used for a wide spectrum of pathology, providing satisfactory outcomes in most cases.

17.
Hand (N Y) ; 17(6): 1031-1038, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33511878

RESUMEN

Vascularized joint transfer (VJT) from the proximal interphalangeal joint (PIPJ) of the toe is an attractive reconstructive option in cases of nonsalvageable finger PIPJ but is limited by equivocal functional outcomes. This systematic review aims to provide an update on vascularized toe-to-finger PIPJ transfers, examining functional outcomes, complications, and the latest refinements in operative technique. A systematic review of the available literature was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Studies examining vascularized toe-to-finger PIPJ transfer for post-traumatic indications were included for analysis. Outcomes assessed included postoperative active range of motion, extension lag, and complications. Thirteen studies examining 210 VJTs were analyzed. Five VJTs experienced microsurgical failure giving an overall survival rate of 97.6%. Average postoperative PIPJ active range of motion (ROM) was 40.3° ± 12.9°, with an average extensor lag of 29° ± 10.5° and mean flexion of 68.9° ± 10.9°. For studies reporting complication outcomes, 59/162 complications were seen. No significant differences were seen between studies published prior to 2013 and after 2013 when comparing digital ROM (P = .123), flexion (P = .602), and extensor lag (P = .280). Studies using a reconstructive algorithm based on prior assessment of the donor toe central slip and recipient finger anatomy had significantly improved ROM outcomes (P = .013). Although VJT provides a reliable option for autologous reconstruction in posttraumatic joints, it is limited by impaired postoperative ROM. Careful assessment of the donor toe and recipient finger anatomy followed by systematic and meticulous reconstruction may lead to improved functional outcomes.


Asunto(s)
Articulaciones de los Dedos , Articulación del Dedo del Pie , Humanos , Articulación del Dedo del Pie/cirugía , Articulaciones de los Dedos/cirugía , Dedos , Rango del Movimiento Articular , Dedos del Pie/cirugía
18.
Hand (N Y) ; : 15589447221127332, 2022 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-36278422

RESUMEN

BACKGROUND: Antegrade homodigital neurovascular island flaps (AHIFs) are a heterogeneous group of pedicled flaps used for reconstruction of traumatic digital detipping injuries. While numerous single-center studies have documented their use, there are no large or multicentre studies validating their efficacy, applicability, and functional outcomes. We performed a systematic review of the contemporary literature to establish the safety and functional outcomes of this technique. METHODS: Electronic searches were performed using PubMED, Embase, and MEDLINE from inception date to October 2020, with further studies identified from study reference lists and independent searches. Relevant studies reported on complications and functional outcomes of the AHIFs, as used for digital detipping injuries. Data were then extracted and analyzed. RESULTS: Twenty-seven studies published between 1974 and 2019 yielded 744 patients. Four studies provided incomplete epidemiologic data, resulting in a total of 559 patients with 584 digital injuries. Index and middle fingers were most frequently involved. Mean final 2-point discrimination (2-PD) was 4.9 mm static and 5.1 mm dynamic, with dynamic 2-PD reported in 2 studies. Mean total active motion of the digit was 200.3°. Mean time to return to work was 6.7 weeks in 10 studies. Flap survivorship was found to be 99.6% in 23 studies. Cold intolerance was the most common complication at 18%, followed by pain and hypersensitivity. CONCLUSIONS: Antegrade homodigital neurovascular island flaps provide a safe and effective method of treating distal finger amputations, yielding satisfactory functional outcomes across all ages. Further studies comparing outcomes between the AHIFs and other reconstructive modalities would be useful.

19.
ANZ J Surg ; 92(10): 2655-2660, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35785509

RESUMEN

BACKGROUND: Fractures of the hand, specifically the metacarpals and phalanges, are a common injury. Whilst many of these fractures can be treated non-operatively, a number of advances have led to the increase in popularity of surgical intervention. The aim of this study was to assess and describe trends in management of phalangeal and metacarpal fractures in Australia over the last two decades. METHODS: A review was conducted of the Medicare Benefits Scheme (MBS), specifically querying the item numbers pertaining to the management of metacarpal and phalanx fractures. Data was recorded as the incidence per 100 000 patients. RESULTS: Overall, there was a statistically significant decrease in the incidence of closed reduction of metacarpal and phalanx fractures, with a converse statistically significant increase in open reduction internal fixation. CONCLUSION: This study demonstrates that over the last 20 years, there has been a decrease in closed reduction of intra- and extra-articular phalangeal and metacarpal fractures, with a converse but smaller increase in open reduction and fixation. These trends are likely multi-factorial in aetiology, and should be monitored to guide resource allocation and health provision in the future.


Asunto(s)
Falanges de los Dedos de la Mano , Fracturas Óseas , Traumatismos de la Mano , Huesos del Metacarpo , Anciano , Australia/epidemiología , Falanges de los Dedos de la Mano/cirugía , Fijación Interna de Fracturas , Fracturas Óseas/epidemiología , Fracturas Óseas/cirugía , Traumatismos de la Mano/cirugía , Humanos , Huesos del Metacarpo/cirugía , Programas Nacionales de Salud
20.
Hand (N Y) ; 17(4): 595-601, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-32988227

RESUMEN

Proximal phalangeal fractures have traditionally been fixed via either Kirschner wires or dorsal plating. Concerns regarding lack of compression and potential for infection with wire fixation, and adhesion formation and stiffness with plating, have lead to alternative fixation methods, such as intramedullary screw fixation. However, the literature regarding this modality is limited. Methods: A systematic review was performed to review the literature regarding intramedullary screw fixation for proximal phalangeal fractures. English language studies that reported original data and commented on at least one postoperative measure of function were eligible for inclusion. 4 studies were eligible for inclusion, with a further 3 studies assessing proximal and middle phalanges analysed separately. Total active motion was greater than 240° in all proximal phalangeal studies; mean post-operative DASH was 3.62. 6% of patients sustained a major complication. Intramedullary screw fixation of proximal phalangeal fractures is safe, providing stable fixation to allow early motion.


Asunto(s)
Falanges de los Dedos de la Mano , Fracturas Óseas , Tornillos Óseos , Hilos Ortopédicos , Falanges de los Dedos de la Mano/cirugía , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA