RESUMEN
Nanoscale tellurium (Te) materials are promising for advanced optoelectronics owing to their outstanding photoelectrical properties. In this work, high-performance optoelectronic nanodevice based on a single tellurium nanotube (NT) was prepared by focused ion beam (FIB)-assisted technique. The individual Te NT photodetector demonstrates a high photoresponsivity of 1.65 × 104 AW-1 and a high photoconductivity gain of 5.0 × 106%, which shows great promise for further optoelectronic device applications.
RESUMEN
Ti-doped truncated octahedron LiTixMn2-xO4 nanocomposites were synthesized through a facile hydrothermal treatment and calcination process. By using spherical aberration-corrected scanning transmission electron microscopy (Cs-STEM), the effects of Ti-doping on the structure evolution and stability enhancement of LiMn2O4 are revealed. It is found that truncated octahedrons are easily formed in Ti doping LiMn2O4 material. Structural characterizations reveal that most of the Ti4+ ions are composed into the spinel to form a more stable spinel LiTixMn2-xO4 phase framework in bulk. However, a portion of Ti4+ ions occupy 8a sites around the {001} plane surface to form a new TiMn2O4-like structure. The combination of LiTixMn2-xO4 frameworks in bulk and the TiMn2O4-like structure at the surface may enhance the stability of the spinel LiMn2O4. Our findings demonstrate the critical role of Ti doping in the surface chemical and structural evolution of LiMn2O4 and may guide the design principle for viable electrode materials.
RESUMEN
Graphene oxide-Fe3O4 (GO-Fe3O4) nanocomposite was synthesized by a facile chemical co-precipitation method. The GO-Fe3O4 was used as magnetic sorbent to extract the eight psychoactive drugs from urine samples. The analytes are morphine (MOR), 6-monoacetylmorphine (6-MAM), amphetamine (AMP), methamphetamine (MAMP), codeine, cocaine, dolantin and benzoylecgonine (BZE), which were determined by ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). This method has high selectivity for the target analytes. The limit of detection (LOD) and limit of quantification (LOQ) were 0.02-0.2 µg L-1 and 0.05-0.5 µg L-1, respectively. The Mandel's fitting test revealed good linearity within all linear ranges. The linear ranges were calculated as 0.05-1000 µg L-1 for AMP, MAMP, cocaine and dolantin; 0.1-1000 µg L-1 for 6-MAM and codein; and 0.5-1000 µg L-1 for MOR and BZE. The recoveries ranged in 80.4-105.5%. The intra-day and inter-day RSDs are in the range of 2.7-13.1% and 3.9-13.7%, respectively. Magnetic solid phase extraction (MSPE) with GO-Fe3O4 provides a convenient, rapid and green sample pretreatment method for extracting the target psychoactive drugs from urine. This methodology can be used for simultaneous or individual detection of eight major psychoactive drugs with high sensitivity. This method has high potential in clinical and forensic areas for psychoactive drugs analysis.