RESUMEN
BACKGROUND: There is increasing evidence that defibrillation from prolonged ventricular fibrillation (VF) before CPR decreases survival. It remains unclear, however, whether harmful effects are due primarily to initial countershock of ischemic myocardium or to resultant postdefibrillation rhythms (ie, pulseless electrical activity [PEA] or asystole). METHODS AND RESULTS: We induced 15 dogs into 12 minutes of VF and randomized them to 3 groups. Group 1 was defibrillated at 12 minutes and then administered advanced cardiac life support (ACLS); group 2 was allowed to remain in VF and was subsequently defibrillated after 4 minutes of ACLS; group 3 was defibrillated at 12 minutes, electrically refibrillated, and then defibrillated after 4 minutes of ACLS. All group 1 and 3 animals were defibrillated into PEA/asystole at 12 minutes. After 4 minutes of ACLS, group 2 and 3 animals were effectively defibrillated into sinus rhythm. The extension of VF in group 2 and 3 subjects paradoxically resulted in shorter mean resuscitation times (251+/-15 and 245+/-7 seconds, respectively, versus 459+/-66 seconds for group 1; P<0.05) and improved 1-hour survival (10 of 10 group 2 and 3 dogs versus 1 of 5 group 1 dogs; Fisher's exact, P<0.005) compared with more conservatively managed group 1 subjects. CONCLUSIONS: Precountershock CPR during VF appears more conducive to resuscitation than CPR during postcountershock PEA or asystole. The intentional induction of VF may prove useful in the management of PEA and asystolic arrests.
Asunto(s)
Reanimación Cardiopulmonar , Paro Cardíaco/fisiopatología , Fibrilación Ventricular/fisiopatología , Animales , Perros , Cardioversión Eléctrica , Estimulación Eléctrica , Paro Cardíaco/prevención & control , Ventrículos Cardíacos/fisiopatología , Hemodinámica/fisiología , Factores de Tiempo , Disfunción Ventricular Izquierda/fisiopatología , Fibrilación Ventricular/terapiaRESUMEN
BACKGROUND: Survival after prolonged ventricular fibrillation (VF) appears severely limited by 2 major factors: (1) low defibrillation success rates and (2) persistent post-countershock myocardial dysfunction. Biphasic (BP) waveforms may prove capable of favorably modifying these limitations. However, they have not been rigorously tested against monophasic (MP) waveforms in clinical models of external defibrillation, particularly where rescue from prolonged VF is the general rule. METHODS AND RESULTS: We randomized 26 dogs to external countershocks with either MP or BP waveforms. Hemodynamics were assessed after shocks applied during sinus rhythm, after brief VF (>10 seconds), and after resuscitation from prolonged VF (>10 minutes). Short-term differences in percent change in left ventricular +dP/dt(max) (MP -16+/-28%, BP +9.1+/-24%; P=0.03) and left ventricular -dP/dt(max) (MP -37+/-26%, BP -18+/-20%; P=0.05) were present after rescue from brief VF, with BP animals exhibiting less countershock-induced dysfunction. After prolonged VF, the BP group had lower mean defibrillation thresholds (107+/-57 versus 172+/-88 J for MP, P=0.04) and significantly shorter resuscitation times (397+/-73.7 versus 488+/-74.3 seconds for MP, P=0.03). CONCLUSIONS: External defibrillation is more efficacious with BP countershocks than with MP countershocks. The lower defibrillation thresholds and shorter resuscitation times associated with BP waveform defibrillation may improve survival after prolonged VF arrest.
Asunto(s)
Cardioversión Eléctrica/métodos , Resucitación , Fibrilación Ventricular/terapia , Animales , Presión Sanguínea , Cardiomiopatías/etiología , Cardiomiopatías/fisiopatología , Circulación Coronaria , Perros , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/normas , Corazón/fisiopatología , Paro Cardíaco/terapia , Factores de TiempoRESUMEN
The authors devised a nonthoracotomy defibrillation system for a patient with a prosthetic tricuspid valve using existing technology and previously established implantation techniques. Their lead configuration deviates substantially from existing designs in its primary use of a coronary sinus defibrillation coil and a left-sided subcutaneous array to distribute current across the ventricular myocardium.