Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Med Phys ; 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39140650

RESUMEN

BACKGROUND: Fluoroscopy guided interventions (FGIs) pose a risk of prolonged radiation exposure; personalized patient dosimetry is necessary to improve patient safety during these procedures. However, current FGIs systems do not capture the precise exposure regions of the patient, making it challenging to perform patient-procedure-specific dosimetry. Thus, there is a pressing need to develop approaches to extract and use this information to enable personalized radiation dosimetry for interventional procedures. PURPOSE: To propose a deep learning (DL) approach for the automatic localization of 3D anatomical landmarks on randomly collimated and magnified 2D head fluoroscopy images. MATERIALS AND METHODS: The model was developed with datasets comprising 800 000 pseudo 2D synthetic images (mixture of vessel-enhanced and non-enhancement), each with 55 annotated anatomical landmarks (two are landmarks for eye lenses), generated from 135 retrospectively collected head computed tomography (CT) volumetric data. Before training, dynamic random cropping was performed to mimic the varied field-size collimation in FGI procedures. Gaussian-distributed additive noise was applied to each individual image to enhance the robustness of the DL model in handling image degradation that may occur during clinical image acquisition in a clinical environment. The model was trained with 629 370 synthetic images for approximately 275 000 iterations and evaluated against a synthetic image test set and a clinical fluoroscopy test set. RESULTS: The model shows good performance in estimating in- and out-of-image landmark positions and shows feasibility to instantiate the skull shape. The model successfully detected 96.4% and 92.5% 2D and 3D landmarks, respectively, within a 10 mm error on synthetic test images. It demonstrated an average of 3.6 ± 2.3 mm mean radial error and successfully detected 96.8% 2D landmarks within 10 mm error on clinical fluoroscopy images. CONCLUSION: Our deep-learning model successfully localizes anatomical landmarks and estimates the gross shape of skull structures from collimated 2D projection views. This method may help identify the exposure region required for patient-specific organ dosimetry in FGIs procedures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA