Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Science ; 241(4868): 956-8, 1988 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-17731445

RESUMEN

Along-term goal of inertial-confinement fusion research is the generation of energy by imploding capsules containing deuterium-tritium fuel. Progress in designing the capsules is aided by accurate imaging of the fusion burn. Penumbral coded-aperture techniques have been used to obtain neutron images that are a direct measurement of the fusion burn region in the capsules.

2.
Rev Sci Instrum ; 79(2 Pt 1): 023501, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315293

RESUMEN

Neutron-imaging systems are being considered as an ignition diagnostic for the National Ignition Facility (NIF) [Hogan et al., Nucl. Fusion 41, 567 (2001)]. Given the importance of these systems, a neutron-imaging design tool is being used to quantify the effects of aperture fabrication and alignment tolerances on reconstructed neutron images for inertial confinement fusion. The simulations indicate that alignment tolerances of more than 1 mrad would introduce measurable features in a reconstructed image for both pinholes and penumbral aperture systems. These simulations further show that penumbral apertures are several times less sensitive to fabrication errors than pinhole apertures.

3.
Rev Sci Instrum ; 49(5): 650, 1978 May.
Artículo en Inglés | MEDLINE | ID: mdl-18699166

RESUMEN

A streak camera technique with temporal resolution of 20 ps has been used to measure the fluorescence properties of several subnanosecond plastic scintillators. The method employs a vacuum light pipe coupled to an optical streak camera. The scintillators are excited by a 200-ps x-ray pulse generated by a 1.06-microm Nd:YAG laser focused onto an iron target. The time history of the low-energy x-ray pulse is measured with an x-ray streak camera. Results are given for NElll plastic scintillators doped with benzophenone or acetophenone, for PVT doped with butyl-PBD, and for a ZnO phosphor doped with Ga.


Asunto(s)
Ensayo de Materiales/instrumentación , Nanotecnología/instrumentación , Plásticos/química , Plásticos/efectos de la radiación , Radiometría/instrumentación , Radiometría/métodos , Conteo por Cintilación/instrumentación , Relación Dosis-Respuesta en la Radiación , Ensayo de Materiales/métodos , Nanotecnología/métodos , Dosis de Radiación , Conteo por Cintilación/métodos , Sensibilidad y Especificidad , Rayos X
4.
Rev Sci Instrum ; 83(10): 10D308, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126835

RESUMEN

DT neutron yield (Y(n)), ion temperature (T(i)), and down-scatter ratio (dsr) determined from measured neutron spectra are essential metrics for diagnosing the performance of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). A suite of neutron-time-of-flight (nTOF) spectrometers and a magnetic recoil spectrometer (MRS) have been implemented in different locations around the NIF target chamber, providing good implosion coverage and the complementarity required for reliable measurements of Y(n), T(i), and dsr. From the measured dsr value, an areal density (ρR) is determined through the relationship ρR(tot) (g∕cm(2)) = (20.4 ± 0.6) × dsr(10-12 MeV). The proportionality constant is determined considering implosion geometry, neutron attenuation, and energy range used for the dsr measurement. To ensure high accuracy in the measurements, a series of commissioning experiments using exploding pushers have been used for in situ calibration of the as-built spectrometers, which are now performing to the required accuracy. Recent data obtained with the MRS and nTOFs indicate that the implosion performance of cryogenically layered DT implosions, characterized by the experimental ignition threshold factor (ITFx), which is a function of dsr (or fuel ρR) and Y(n), has improved almost two orders of magnitude since the first shot in September, 2010.

5.
Rev Sci Instrum ; 81(10): 10E121, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033986

RESUMEN

Moderately priced oscilloscopes available for the NIF power sensors and target diagnostics have 6 GHz bandwidths at 20-25 Gsamples/s (40 ps sample spacing). Some NIF experiments require cross timing between instruments be determined with accuracy better than 30 ps. A simple analysis algorithm for Gaussian-like pulses such as the 100-ps-wide NIF timing fiducial can achieve single-event cross-timing precision of 1 ps (1/50 of the sample spacing). The midpoint-timing algorithm is presented along with simulations that show why the technique produces good timing results. Optimum pulse width is found to be ∼2.5 times the sample spacing. Experimental measurements demonstrate use of the technique and highlight the conditions needed to obtain optimum timing performance.

6.
Rev Sci Instrum ; 81(10): 10D319, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033845

RESUMEN

The first 3 of 18 neutron time-of-flight (nTOF) channels have been installed at the National Ignition Facility (NIF). The role of these detectors includes yield, temperature, and bang time measurements. This article focuses on nTOF data analysis and quality of results obtained for the first set of experiments to use all 192 NIF beams. Targets produced up to 2×10(10) 2.45 MeV neutrons for initial testing of the nTOF detectors. Differences in neutron scattering at the OMEGA laser facility where the detectors were calibrated and at NIF result in different response functions at the two facilities. Monte Carlo modeling shows this difference. The nTOF performance on these early experiments indicates that the nTOF system with its full complement of detectors should perform well in future measurements of yield, temperature, and bang time.

7.
Rev Sci Instrum ; 81(10): 10D325, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033848

RESUMEN

The National Ignition Facility (NIF) successfully completed its first inertial confinement fusion (ICF) campaign in 2009. A neutron time-of-flight (nTOF) system was part of the nuclear diagnostics used in this campaign. The nTOF technique has been used for decades on ICF facilities to infer the ion temperature of hot deuterium (D(2)) and deuterium-tritium (DT) plasmas based on the temporal Doppler broadening of the primary neutron peak. Once calibrated for absolute neutron sensitivity, the nTOF detectors can be used to measure the yield with high accuracy. The NIF nTOF system is designed to measure neutron yield and ion temperature over 11 orders of magnitude (from 10(8) to 10(19)), neutron bang time in DT implosions between 10(12) and 10(16), and to infer areal density for DT yields above 10(12). During the 2009 campaign, the three most sensitive neutron time-of-flight detectors were installed and used to measure the primary neutron yield and ion temperature from 25 high-convergence implosions using D(2) fuel. The OMEGA yield calibration of these detectors was successfully transferred to the NIF.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA