Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
N Engl J Med ; 387(10): 869-881, 2022 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-36069869

RESUMEN

BACKGROUND: Open-source automated insulin delivery (AID) systems are used by many patients with type 1 diabetes. Data are needed on the efficacy and safety of an open-source AID system. METHODS: In this multicenter, open-label, randomized, controlled trial, we assigned patients with type 1 diabetes in a 1:1 ratio to use an open-source AID system or a sensor-augmented insulin pump (control). The patients included both children (defined as 7 to 15 years of age) and adults (defined as 16 to 70 years of age). The AID system was a modified version of AndroidAPS 2.8 (with a standard OpenAPS 0.7.0 algorithm) paired with a preproduction DANA-i insulin pump and Dexcom G6 CGM, which has an Android smartphone application as the user interface. The primary outcome was the percentage of time in the target glucose range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter) between days 155 and 168 (the final 2 weeks of the trial). RESULTS: A total of 97 patients (48 children and 49 adults) underwent randomization (44 to open-source AID and 53 to the control group). At 24 weeks, the mean (±SD) time in the target range increased from 61.2±12.3% to 71.2±12.1% in the AID group and decreased from 57.7±14.3% to 54.5±16.0% in the control group (adjusted difference, 14 percentage points; 95% confidence interval, 9.2 to 18.8; P<0.001), with no treatment effect according to age (P = 0.56). Patients in the AID group spent 3 hours 21 minutes more in the target range per day than those in the control group. No severe hypoglycemia or diabetic ketoacidosis occurred in either group. Two patients in the AID group withdrew from the trial owing to connectivity issues. CONCLUSIONS: In children and adults with type 1 diabetes, the use of an open-source AID system resulted in a significantly higher percentage of time in the target glucose range than the use of a sensor-augmented insulin pump at 24 weeks. (Supported by the Health Research Council of New Zealand; Australian New Zealand Clinical Trials Registry number, ACTRN12620000034932.).


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Bombas de Infusión , Insulina , Adolescente , Adulto , Anciano , Australia , Glucemia/análisis , Niño , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Persona de Mediana Edad , Adulto Joven
2.
Diabet Med ; : e15348, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758653

RESUMEN

AIMS: To investigate the impact of real-time continuous glucose monitoring (rtCGM) on glycaemia in a predominantly indigenous (Maori) population of adults with insulin-requiring type 2 diabetes (T2D) in New Zealand. METHODS: Twelve-week, multicentre randomised controlled trial (RCT) of adults with T2D using ≥0.2 units/kg/day of insulin and elevated glycated haemoglobin (HbA1c) ≥64 mmol/mol (8.0%). Following a 2-week blinded CGM run-in phase, participants were randomised to rtCGM or control (self-monitoring blood glucose [SMBG]). The primary outcome was time in the target glucose range (3.9-10 mmol/L; TIR) during weeks 10-12, with data collected by blinded rtCGM in the control group. RESULTS: Sixty-seven participants entered the RCT phase (54% Maori, 57% female), median age 53 (range 16-70 years), HbA1c 85 (IQR 74, 94) mmol/mol (9.9 [IQR 8.9, 10.8]%), body mass index (36.7 ± 7.7 kg/m2). Mean (±SD) TIR increased from 37 (24)% to 53 (24)% [Δ 13%; 95% CI 4.2 to 22; P = 0.007] in the rtCGM group but did not change in the SMBG group [45 (21)% to 45 (25)%, Δ 2.5%, 95% CI -6.1 to 11, P = 0.84]. Baseline-adjusted between-group difference in TIR was 10.4% [95% CI -0.9 to 21.7; P = 0.070]. Mean HbA1c (±SD) decreased in both groups from 85 (18) mmol/mol (10.0 [1.7]%) to 64 (16) mmol/mol (8.0 [1.4]%) in the rtCGM arm and from 81 (12) mmol/mol (9.6 [1.1]%) to 65 (13) mmol/mol (8.1 [1.2]%) in the SMBG arm (P < 0.001 for both). There were no severe hypoglycaemic or ketoacidosis events in either group. CONCLUSIONS: Real-time CGM use in a supportive treat-to-target model of care likely improves glycaemia in a population with insulin-treated T2D and elevated HbA1c.

3.
Diabet Med ; 39(5): e14750, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34826158

RESUMEN

BACKGROUND: Open-source automated insulin delivery (AID) is a user-driven treatment modality used by thousands globally. Healthcare professionals' (HCPs) ability to support users of this technology is limited by a lack of knowledge of these systems. AIMS: To describe the challenges experienced by HCPs supporting participants' use of open-source automated insulin delivery in the Community deRivEd AuTomatEd insulin delivery (CREATE) study. METHODS: Data were collected prospectively from the study team's fortnightly meetings and Slack Workspace (Slack Technologies, Ltd. 2018) during the first 4 months of the trial. Key topics were identified from minutes of meetings. Slack conversations were categorised by topic, with the number of posts per conversation, number of sites per conversation and involvement of experts in open-source AID being recorded. RESULTS: In the first 4 months of the trial, there were 254 conversations in Slack with a mean of 5.2 (±4.25) posts per conversation. The most frequent learning challenge was insulin pump and cannula problems relating to the DANA-iTM insulin pump, which totalled 24.0% of all conversations. Experts on open-source AID use were involved in 83.3% of conversations. CONCLUSIONS: A significant proportion of challenges related to specific devices, rather than AID. Challenges relating to the functioning of open-source AID were more likely to involve input from experts in open-source AID. This is the first report of challenges experienced by a multidisciplinary team in a supported open-source environment that may inform expectations in routine clinical care.


Asunto(s)
Diabetes Mellitus Tipo 1 , Páncreas Artificial , Atención a la Salud , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico
4.
J Diabetes Metab Disord ; 23(1): 1163-1171, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38932793

RESUMEN

Aims: To explore the lived experiences of initiating real-time continuous glucose monitoring (rt-CGM) use in individuals with type 2 diabetes using insulin. Methods: Twelve semi-structured interviews were conducted amongst individuals with type 2 diabetes taking insulin who were enrolled in the 2GO-CGM randomised controlled trial and had completed 3 months of rtCGM. Interviews were transcribed verbatim and analysed to identify common themes regarding their experiences. Results: The interviews revealed three key themes: i) rtCGM as a facilitator of improved health behaviours; ii) the acceptability of rtCGM systems compared to capillary blood glucose testing; and iii) barriers to the continual usage of rtCGM technology - including: connection difficulties, longevity of the sensors, and local cutaneous reactions to the sensor adhesive. Conclusion: Adults on insulin with type 2 diabetes find rtCGM systems widely acceptable, and easier to engage with than traditional self-monitoring of capillary blood glucose. Supplementary Information: The online version contains supplementary material available at 10.1007/s40200-024-01403-9.

5.
J Diabetes Metab Disord ; 22(2): 1779-1792, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37969919

RESUMEN

Purpose: Improving glycaemic control in type 2 diabetes (T2D) is essential to reducing social and health-economic burden of diabetes-related complications. Continuous glucose monitoring (CGM) has been established as beneficial in improving glycaemic control and reducing hypoglycaemia in people with type 1 diabetes, however data in T2D is limited. This study has been designed to assess the effect of initiating real-time CGM (rtCGM) on glycaemic control in a high-risk population of adults with T2D. Secondary objectives are to assess the cost-effectiveness and safety of rtCGM, and the effects of rtCGM on diet/lifestyle and the burden of diabetic complications, including cardiovascular risk. Methods: This multicentre randomised controlled trial (RCT) will be conducted at three sites in New Zealand (Waikato, Christchurch and Dunedin). Eighty adults with T2D on insulin with suboptimal glycaemic control (HbA1c > 8.0% or 64 mmol/mol) will be randomised 1:1 to rtCGM or routine care with self-monitoring of blood glucose levels (SMBG) for three months. This intervention phase will be followed by a three-month continuation phase where SMBG group crossover to use rtCGM. Participants will then be invited to join the extension phase with continued use of rtCGM for a further 12 months. During the extension phase, both groups will independently titrate their insulin under the remote supervision of prescribing diabetes nurse specialists following an insulin titration algorithm. The primary outcome of the study is time in target glucose range (3.9-10 mmol/L or 70-180 mg/dL; TIR). Secondary outcomes include CGM metrics as per consensus statement recommendations, and HbA1c. Additional planned analyses include cardiovascular risk profile, incremental cost-effectiveness analyses, dietary patterns, and qualitative analyses. Trial registration number: The trial was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12621000889853) on 8 July 2021 and the World Health Organisation International Clinical Trial Registry Platform (Universal Trial Number U1111-1264-5822).

6.
J Diabetes Metab Disord ; 22(1): 861-871, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37250371

RESUMEN

Purpose: Open-source automated insulin delivery (AID) is used by thousands of people with type 1 diabetes (T1D), but has unknown generalisability to marginalised ethnic groups. This study explored experiences of Indigenous Maori participants in the CREATE trial with use of an open-source AID system to identify enablers/barriers to health equity. Methods: The CREATE randomised trial compared open-source AID (OpenAPS algorithm on an Android phone with a Bluetooth-connected pump) to sensor-augmented pump therapy. Kaupapa Maori Research methodology was used in this sub-study. Ten semi-structured interviews with Maori participants (5 children, 5 adults) and whanau (extended family) were completed. Interviews were recorded and transcribed, and data were analysed thematically. NVivo was used for descriptive and pattern coding. Results: Enablers/barriers to equity aligned with four themes: access (to diabetes technologies), training/support, operation (of open-source AID), and outcomes. Participants described a sense of empowerment, and improved quality of life, wellbeing, and glycaemia. Parents felt reassured by the system's ability to control glucose, and children were granted greater independence. Participants were able to use the open-source AID system with ease to suit whanau needs, and technical problems were manageable with healthcare professional support. All participants identified structures in the health system precluding equitable utilisation of diabetes technologies for Maori. Conclusion: Maori experienced open-source AID positively, and aspired to use this therapy; however, structural and socio-economic barriers to equity were identified. This research proposes strength-based solutions which should be considered in the redesign of diabetes services to improve health outcomes for Maori with T1D.Trial Registration: The CREATE trial, encompassing this qualitative sub-study, was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12620000034932p) on the 20th January 2020. Supplementary Information: The online version contains supplementary material available at 10.1007/s40200-023-01215-3.

7.
Diabetes Technol Ther ; 25(4): 250-259, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36763345

RESUMEN

Aim: To assess long-term efficacy and safety of open-source automated insulin delivery (AID) in children and adults (7-70 years) with type 1 diabetes. Methods: Both arms of a 24-week randomized controlled trial comparing open-source AID (OpenAPS algorithm within a modified version of AndroidAPS, preproduction DANA-i™ insulin pump, Dexcom G6 continuous glucose monitor) with sensor-augmented pump therapy (SAPT), entered a 24-week continuation phase where the SAPT arm (termed SAPT-AID) crossed over to join the open-source AID arm (termed AID-AID). Most participants (69/94) used a preproduction YpsoPump® insulin pump during the continuation phase. Analyses incorporated all 52 weeks of data, and combined between-group and within-subject differences to calculate an overall "treatment effect" of AID versus SAPT. Results: Mean time in range (TIR; 3.9-10 mmol/L [70-180 mg/dL]) was 12.2% higher with AID than SAPT (95% confidence interval [CI] 10.4 to 14.1; P < 0.001). TIR was 56.9% (95% CI 54.2 to 59.6) with SAPT and 69.1% (95% CI 67.1 to 71.1) with AID. The treatment effect did not differ by age (P = 0.39) or insulin pump type (P = 0.37). HbA1c was 5.1 mmol/mol lower [0.5%] with AID (95% CI -6.6 to -3.6; P < 0.001). There were no episodes of diabetic ketoacidosis or severe hypoglycemia with either treatment over the 48 weeks. Six participants (all in SAPT-AID) withdrew: three with hardware issues, two preferred SAPT, and one with infusion-site skin irritation. Conclusion: Further evaluation of the community derived automated insulin delivery (CREATE) trial to 48 weeks confirms that open-source AID is efficacious and safe with different insulin pumps, and demonstrates sustained glycemic improvements without additional safety concerns.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Adulto , Humanos , Niño , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Hipoglucemia/inducido químicamente , Glucemia , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA