Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Sensors (Basel) ; 24(9)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38732996

RESUMEN

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

2.
Opt Express ; 31(10): 15355-15371, 2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37157639

RESUMEN

X-ray tomography is a non-destructive imaging technique that reveals the interior of an object from its projections at different angles. Under sparse-view and low-photon sampling, regularization priors are required to retrieve a high-fidelity reconstruction. Recently, deep learning has been used in X-ray tomography. The prior learned from training data replaces the general-purpose priors in iterative algorithms, achieving high-quality reconstructions with a neural network. Previous studies typically assume the noise statistics of test data are acquired a priori from training data, leaving the network susceptible to a change in the noise characteristics under practical imaging conditions. In this work, we propose a noise-resilient deep-reconstruction algorithm and apply it to integrated circuit tomography. By training the network with regularized reconstructions from a conventional algorithm, the learned prior shows strong noise resilience without the need for additional training with noisy examples, and allows us to obtain acceptable reconstructions with fewer photons in test data. The advantages of our framework may further enable low-photon tomographic imaging where long acquisition times limit the ability to acquire a large training set.

3.
Opt Express ; 31(3): 4899-4919, 2023 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-36785446

RESUMEN

Photon echoes in rare-earth-doped crystals are studied to understand the challenges of making broadband quantum memories using the atomic frequency comb (AFC) protocol in systems with hyperfine structure. The hyperfine structure of Pr3+ poses an obstacle to this goal because frequencies associated with the hyperfine transitions change the simple picture of modulation at an externally imposed frequency. The current work focuses on the intermediate case where the hyperfine spacing is comparable to the comb spacing, a challenging regime that has recently been considered. Operating in this regime may facilitate storing quantum information over a larger spectral range in such systems. In this work, we prepare broadband AFCs using optical combs with tooth spacings ranging from 1 MHz to 16 MHz in fine steps, and measure transmission spectra and photon echoes for each. We predict the spectra and echoes theoretically using the optical combs as input to either a rate equation code or a density matrix code, which calculates the redistribution of populations. We then use the redistributed populations as input to a semiclassical theory using the frequency-dependent dielectric function. The two sets of predictions each give a good, but different account of the photon echoes.

4.
Metrologia ; 60(2)2023.
Artículo en Inglés | MEDLINE | ID: mdl-38379870

RESUMEN

A technique for characterizing and correcting the linearity of radiometric instruments is known by the names the "flux-addition method" and the "combinatorial technique". In this paper, we develop a rigorous uncertainty quantification method for use with this technique and illustrate its use with both synthetic data and experimental data from a "beam conjoiner" instrument. We present a probabilistic model that relates the instrument readout to a set of unknown fluxes via a set of polynomial coefficients. Maximum likelihood estimates (MLEs) of the unknown fluxes and polynomial coefficients are recommended, while a non-parametric bootstrap algorithm enables uncertainty quantification including standard errors and confidence intervals. The synthetic data represent plausible outputs of a radiometric instrument and enable testing and validation of the method. The MLEs for these data are found to be approximately unbiased, and confidence intervals derived from the bootstrap replicates are found to be consistent with their target coverage of 95%. For the polynomial coefficients, the observed coverages range from 91% to 99%. The experimental data set illustrates how a complete calibration with uncertainties can be achieved using the method plus one well-known flux level. The uncertainty contribution attributable to estimation of the instrument's nonlinear response is less than 0.025% over most of its range.

5.
Opt Express ; 30(13): 23238-23259, 2022 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-36225009

RESUMEN

X-ray tomography is capable of imaging the interior of objects in three dimensions non-invasively, with applications in biomedical imaging, materials science, electronic inspection, and other fields. The reconstruction process can be an ill-conditioned inverse problem, requiring regularization to obtain satisfactory results. Recently, deep learning has been adopted for tomographic reconstruction. Unlike iterative algorithms which require a distribution that is known a priori, deep reconstruction networks can learn a prior distribution through sampling the training distributions. In this work, we develop a Physics-assisted Generative Adversarial Network (PGAN), a two-step algorithm for tomographic reconstruction. In contrast to previous efforts, our PGAN utilizes maximum-likelihood estimates derived from the measurements to regularize the reconstruction with both known physics and the learned prior. Compared with methods with less physics assisting in training, PGAN can reduce the photon requirement with limited projection angles to achieve a given error rate. The advantages of using a physics-assisted learned prior in X-ray tomography may further enable low-photon nanoscale imaging.

6.
Opt Express ; 29(2): 1788-1804, 2021 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-33726385

RESUMEN

A reconstruction algorithm for partially coherent x-ray computed tomography (XCT) including Fresnel diffraction is developed and applied to an optical fiber. The algorithm is applicable to a high-resolution tube-based laboratory-scale x-ray tomography instrument. The computing time is only a few times longer than the projective counterpart. The algorithm is used to reconstruct, with projections and diffraction, a tilt series acquired at the micrometer scale of a graded-index optical fiber using maximum likelihood and a Bayesian method based on the work of Bouman and Sauer. The inclusion of Fresnel diffraction removes some reconstruction artifacts and use of a Bayesian prior probability distribution removes others, resulting in a substantially more accurate reconstruction.

7.
Artículo en Inglés | MEDLINE | ID: mdl-35529769

RESUMEN

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of ∼ 1 µm. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.

8.
Microsc Microanal ; 25(1): 70-76, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30869576

RESUMEN

Using a commercial X-ray tomography instrument, we have obtained reconstructions of a graded-index optical fiber with voxels of edge length 1.05 µm at 12 tube voltages. The fiber manufacturer created a graded index in the central region by varying the germanium concentration from a peak value in the center of the core to a very small value at the core-cladding boundary. Operating on 12 tube voltages, we show by a singular value decomposition that there are only two singular vectors with significant weight. Physically, this means scans beyond two tube voltages contain largely redundant information. We concentrate on an analysis of the images associated with these two singular vectors. The first singular vector is dominant and images of the coefficients of the first singular vector at each voxel look are similar to any of the single-energy reconstructions. Images of the coefficients of the second singular vector by itself appear to be noise. However, by averaging the reconstructed voxels in each of several narrow bands of radii, we can obtain values of the second singular vector at each radius. In the core region, where we expect the germanium doping to go from a peak value at the fiber center to zero at the core-cladding boundary, we find that a plot of the two coefficients of the singular vectors forms a line in the two-dimensional space consistent with the dopant decreasing linearly with radial distance from the core center. The coating, made of a polymer rather than silica, is not on this line indicating that the two-dimensional results are sensitive not only to the density but also to the elemental composition.

9.
Artículo en Inglés | MEDLINE | ID: mdl-34877164

RESUMEN

Fundamental limits for the calculation of scattering corrections within X-ray computed tomography (CT) are found within the independent atom approximation from an analysis of the cross sections, CT geometry, and the Nyquist sampling theorem, suggesting large reductions in computational time compared to existing methods. By modifying the scatter by less than 1 %, it is possible to treat some of the elastic scattering in the forward direction as inelastic to achieve a smoother elastic scattering distribution. We present an analysis showing that the number of samples required for the smoother distribution can be greatly reduced. We show that fixed forced detection can be used with many fewer points for inelastic scattering, but that for pure elastic scattering, a standard Monte Carlo calculation is preferred. We use smoothing for both elastic and inelastic scattering because the intrinsic angular resolution is much poorer than can be achieved for projective tomography. Representative numerical examples are given.

10.
Opt Express ; 26(25): 32788-32801, 2018 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-30645441

RESUMEN

The low-latency requirements of a practical loophole-free Bell test preclude time-consuming post-processing steps that are often used to improve the statistical quality of a physical random number generator (RNG). Here we demonstrate a post-processing-free RNG that produces a random bit within 2.4(2) ns of an input trigger. We use weak feedback to eliminate long-term drift, resulting in 24 hour operation with output that is statistically indistinguishable from a Bernoulli process. We quantify the impact of the feedback on the predictability of the output as less than 6.4×10-7 and demonstrate the utility of the Allan variance as a tool for characterizing non-idealities in RNGs.

11.
Appl Opt ; 57(4): 788-793, 2018 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-29400755

RESUMEN

We have significantly accelerated diffraction calculations using three independent acceleration devices. These innovations are restricted to cylindrically symmetrical systems. In the first case, we consider Wolf's formula for integrated flux in a circular region following diffraction of light from a point source by a circular aperture or a circular lens. Although the formula involves a double sum, we evaluate it with the effort of a single sum by use of fast Fourier transforms (FFTs) to perform convolutions. In the second case, we exploit properties of the Fresnel-Kirchhoff propagator in the Gaussian, paraxial optics approximation to achieve the propagation of a partial wave from one optical element to the next. Ordinarily, this would involve a double loop over the radial variables on each element, but we have reduced the computational cost by a factor approximately equal to the smaller number of radius values. In the third case, we reduce the number of partial waves, for which the propagation needs to be calculated, to determine the throughput of an optical system of interest in radiometry when at least one element is very small, such as a pinhole aperture. As a demonstration of the benefits of the second case, we analyze intricate diffraction effects that occur in a satellite-based solar radiometry instrument.

12.
Opt Express ; 25(22): 26728-26746, 2017 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-29092156

RESUMEN

Preliminary experiments at the NIST Spectral Tri-function Automated Reference Reflectometer (STARR) facility have been conducted with the goal of providing the diffuse optical properties of a solid reference standard with optical properties similar to human skin. Here, we describe an algorithm for determining the best-fit parameters and the statistical uncertainty associated with the measurement. The objective function is determined from the profile log likelihood, including both experimental and Monte Carlo uncertainties. Initially, the log likelihood is determined over a large parameter search box using a relatively small number of Monte Carlo samples such as 2·104. The search area is iteratively reduced to include the 99.9999% confidence region, while doubling the number of samples at each iteration until the experimental uncertainty dominates over the Monte Carlo uncertainty. Typically this occurs by 1.28·106 samples. The log likelihood is then fit to determine a 95% confidence ellipse. The inverse problem requires the values of the log likelihood on many points. Our implementation uses importance sampling to calculate these points on a grid in an efficient manner. Ultimately, the time-to-solution is approximately six times the cost of a Monte Carlo simulation of the radiation transport problem for a single set of parameters with the largest number of photons required. The results are found to be 64 times faster than our implementation of Particle Swarm Optimization.

13.
Artículo en Inglés | MEDLINE | ID: mdl-34877089

RESUMEN

The goal of this study was to compare volumetric analysis in computed tomography (CT) with the length measurement prescribed by the Response Evaluation Criteria in Solid Tumors (RECIST) for a system with known mass and unknown shape. We injected 2 mL to 4 mL of water into vials of sodium polyacrylate and into disposable diapers. Volume measurements of the sodium polyacrylate powder were able to predict both mass and proportional changes in mass within a 95 % prediction interval of width 12 % and 16 %, respectively. The corresponding figures for RECIST were 102 % and 82 %.

14.
Opt Express ; 24(13): 14100-23, 2016 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-27410570

RESUMEN

We consider the problem of sorting, by size, spherical particles of order 100 nm radius. The scheme we analyze consists of a heterogeneous stream of spherical particles flowing at an oblique angle across an optical Gaussian mode standing wave. Sorting is achieved by the combined spatial and size dependencies of the optical force. Particles of all sizes enter the flow at a point, but exit at different locations depending on size. Exiting particles may be detected optically or separated for further processing. The scheme has the advantages of accommodating a high throughput, producing a continuous stream of continuously dispersed particles, and exhibiting excellent size resolution. We performed detailed Monte Carlo simulations of particle trajectories through the optical field under the influence of convective air flow. We also developed a method for deriving effective velocities and diffusion constants from the Fokker-Planck equation that can generate equivalent results much more quickly. With an optical wavelength of 1064 nm, polystyrene particles with radii in the neighborhood of 275 nm, for which the optical force vanishes, may be sorted with a resolution below 1 nm.

15.
Opt Express ; 23(12): 16372-82, 2015 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-26193610

RESUMEN

We demonstrate the ability to calibrate a variable optical attenuator directly at the few-photon level using a superconducting Transition Edge Sensor (TES). Because of the inherent linearity of photon-number resolving detection, no external calibrations are required, even for the energy of the laser pulses, which ranged from means of 0.15 to 18 photons per pulse at the detector. To verify this method, calibrations were compared to an independent conventional calibration made at much higher photon fluxes using analog detectors. In all cases, the attenuations estimated by the two methods agree within their uncertainties.Our few-photon measurement determined attenuations using the Poisson-Influenced K-Means Algorithm (PIKA) to extract mean numbers of photons per pulse along with the uncertainties of these means. The robustness of the method is highlighted by the agreement of the two calibrations even in the presence of significant drifts in the optical power over the course of the experiment.Work of the United States Government. Not subject to copyright.

16.
J Res Natl Inst Stand Technol ; 118: 375-80, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-26401438

RESUMEN

We propose a method to extend the frequency range of polarization entanglement in periodically poled rubidium-doped potassium titanyl phosphate (Rb:KTP) waveguides. Our calculations predict that output wavelengths from 1130 nm to 1257 nm may be achieved using Rb:KTP by the appropriate selection of a direction of propagation for the waveguide. The fidelity using a poling period of 1 mm is approximately 0.98.

17.
Microsyst Nanoeng ; 9: 47, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37064166

RESUMEN

We show three-dimensional reconstructions of a region of an integrated circuit from a 130 nm copper process. The reconstructions employ x-ray computed tomography, measured with a new and innovative high-magnification x-ray microscope. The instrument uses a focused electron beam to generate x-rays in a 100 nm spot and energy-resolving x-ray detectors that minimize backgrounds and hold promise for the identification of materials within the sample. The x-ray generation target, a layer of platinum, is fabricated on the circuit wafer itself. A region of interest is imaged from a limited range of angles and without physically removing the region from the larger circuit. The reconstruction is consistent with the circuit's design file.

18.
Med Phys ; 39(5): 2628-37, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22559633

RESUMEN

PURPOSE: The authors wish to determine the extent to which the Response Evaluation Criteria in Solid Tumors (RECIST) and the criteria of the World Health Organization (WHO) can predict tumor volumes and changes in volume using clinical data. METHODS: The data presented are a reanalysis of data acquired in other studies, including the public database from the Lung Image Database Consortium (LIDC) and from a study of liver tumors. RESULTS: The principal result is that a given RECIST diameter predicts volume to a factor of 16 or 10 for the two data sets, respectively, by examining 95% prediction bounds and that changes in volume are predicted only little better: to within a factor of 7 for the liver data. The WHO criteria reduce the prediction bounds by a factor of 1.3 in all cases. Also, the RECIST threshold of 10 mm to measure a nodule corresponds to a transition zone width of a factor of more than 2 in volume for the nodules in the LIDC database. CONCLUSIONS: While the RECIST diameter is certainly correlated with the volume, and similarly for changes in these quantities, the use of the diameter introduces additional variation assuming volume is the quantity of interest. Exactly how much this reduces the statistical power of clinical drug trials is a key open question for future research.


Asunto(s)
Neoplasias Hepáticas/patología , Neoplasias Pulmonares/patología , Carga Tumoral , Incertidumbre , Bases de Datos Factuales , Humanos
20.
Opt Express ; 19(2): 1470-83, 2011 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-21263689

RESUMEN

We present a quantum-mechanical theory to describe narrowband photon-pair generation via four-wave mixing in a Silicon-on-Insulator (SOI) micro-resonator. We also provide design principles for efficient photon-pair generation in an SOI micro-resonator through extensive numerical simulations. Microring cavities are shown to have a much wider dispersion-compensated frequency range than straight cavities. A microring with an inner radius of 8 µm can output an entangled photon comb of 21 pairwise-correlated peaks (42 comb lines) spanning from 1.3 µm to 1.8 µm. Such on-chip quantum photonic devices offer a path toward future integrated quantum photonics and quantum integrated circuits.


Asunto(s)
Sistemas Microelectromecánicos/instrumentación , Dispositivos Ópticos , Refractometría/instrumentación , Transductores , Diseño Asistido por Computadora , Conductividad Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización , Fotones , Teoría Cuántica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA