Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
J Interv Card Electrophysiol ; 38(3): 197-202, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24022757

RESUMEN

PURPOSE: Cardiac rhythm management devices (CRMD) require a ventricular lead to be placed across the tricuspid valve. Tricuspid regurgitation (TR) is an under-recognized clinical complication of lead implantation and its clinical significance is unknown. We studied the incidence of hospitalizations for congestive heart failure (CHF) exacerbation among patients with worsening TR after ventricular lead implantation. METHODS: We reviewed 148 patients (age 68 ± 15) that received a CRMD. TR and pulmonary artery systolic pressure (PASP) measured by Doppler echocardiography before and after CRMD implantation were analyzed. Hospitalizations for CHF exacerbation post-implantation were counted. RESULTS: Follow-up was 32 ± 14 months. Ninety-nine (67%) patients had no change, 24 (16%) slight, and 9 (6%) significant increase in TR after CRMD implantation, while 13 (9%) patients had slight and 3 (2%) significant improvement. Patients with a significant increase in TR had higher incidence of hospitalizations (1.7 ± 0.5) compared to patients with slight (0.8 ± 1; p = 0.006) or no increase (0.5 ± 1; p = 0.0002) in TR. Patients with significant increase in TR had a greater change in PASP (25 mmHg; p = 0.002) after device implantation compared to those with a slight (10 mmHg; p = 0.002) or no increase (0.7 mmHg; p = 0.17). CONCLUSION: Increased TR following CRMD implantation is relatively common (33%) and correlated with subsequent risk of hospitalization for heart failure. A preventive strategy and close monitoring for development or worsening of CHF after CRMD implantation may help prevent hospital admissions.


Asunto(s)
Estimulación Cardíaca Artificial/estadística & datos numéricos , Electrodos Implantados/estadística & datos numéricos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Complicaciones Posoperatorias/epidemiología , Insuficiencia de la Válvula Tricúspide/epidemiología , Anciano , Estimulación Cardíaca Artificial/efectos adversos , Comorbilidad , Electrodos Implantados/efectos adversos , Femenino , Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos/cirugía , Hospitalización , Humanos , Masculino , Pennsylvania/epidemiología , Prevalencia , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA