RESUMEN

UNLABELLED: Our objective was to compare the stability of Kinevac when reconstituted with sodium chloride injection, USP, 0.9%, versus the manufacturer's recommended sterile water for injection, USP, and to determine the effects on stability of deviating from the manufacturer's recommended methods of product preparation. METHODS: Kinevac was reconstituted with either sterile water or 0.9% sodium chloride. Triplicate high-performance liquid chromatography was performed on each vial of reconstituted sample at time zero and at time zero plus 8 h. The concentration of each sample, as measured by the peak area, was recorded at each time point. The process was repeated over 4 consecutive days. RESULTS: Kinevac reconstituted with sterile water resulted in the recovery of 89.73% of the time zero concentration after 8 h. Kinevac reconstituted with 0.9% sodium chloride resulted in chemical stability of the injection, with 80.05% recovery of the time zero value after 8 h. CONCLUSION: Kinevac is more stable when reconstituted with sterile water than when reconstituted with 0.9% sodium chloride. Kinevac should be reconstituted with sterile water for injection as per the manufacturer's instructions.


Asunto(s)
Sincalida/química , Cloruro de Sodio/química , Cromatografía Líquida de Alta Presión , Estabilidad de Medicamentos , Inyecciones , Agua