1.
J Nucl Cardiol ; 30(4): 1630-1641, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36740650

RESUMEN

PURPOSE: We developed a method of standardizing the heart-to-mediastinal ratio in 123I-labeled meta-iodobenzylguanidine (MIBG) images using a conversion coefficient derived from a dedicated phantom. This study aimed to create a machine-learning (ML) model to estimate conversion coefficients without using a phantom. METHODS: 210 Monte Carlo (MC) simulations of 123I-MIBG images to obtain conversion coefficients using collimators that differed in terms of hole diameter, septal thickness, and length. Simulated conversion coefficients and collimator parameters were prepared as training datasets, then a gradient-boosting ML was trained to estimate conversion coefficients from collimator parameters. Conversion coefficients derived by ML were compared with those that were MC simulated and experimentally derived from 613 phantom images. RESULTS: Conversion coefficients were superior when estimated by ML compared with the classical multiple linear regression model (root mean square deviations: 0.021 and 0.059, respectively). The experimental, MC simulated, and ML-estimated conversion coefficients agreed, being, respectively, 0.54, 0.55, and 0.55 for the low-; 0.74, 0.70, and 0.72 for the low-middle; and 0.88, 0.88, and 0.88 for the medium-energy collimators. CONCLUSIONS: The ML model estimated conversion coefficients without the need for phantom experiments. This means that conversion coefficients were comparable when estimated based on collimator parameters and on experiments.


Asunto(s)
3-Yodobencilguanidina , Mediastino , Humanos , Mediastino/diagnóstico por imagen , Corazón/diagnóstico por imagen , Radioisótopos de Yodo , Fantasmas de Imagen , Método de Montecarlo
2.
Eur J Nucl Med Mol Imaging ; 49(11): 3830-3840, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35451612

RESUMEN

PURPOSE: Radionuclide therapy with 177Lu-DOTATATE is well established for patients with advanced somatostatin receptor-positive neuroendocrine tumors with a standard schedule of 7.4 GBq at four occasions. However, this approach does not consider individual variability affecting the tumor radiation dose or dose to organs at risk. Therefore, it is important to assess more personalized strategies. The aim of this phase II trial was to evaluate individualized 177Lu-DOTATATE for which the number of cycles varied based on renal dosimetry. METHODS: Patients were eligible if they had a progressive, somatostatin receptor-positive neuroendocrine tumor with a Ki 67 labeling index < 20%. They received cycles of 7.4 GBq of 177Lu-DOTATATE at 10 ± 2-week intervals until a predefined radiation dose to the kidneys was reached. The primary endpoint was objective tumor response (RECIST v 1.1). Secondary endpoints included progression-free survival (PFS), overall survival (OS), and toxicity (CTCAE v. 4.0). RESULTS: Ninety-six patients who had received a median of 5 cycles (range 1-9) were evaluable for efficacy. The objective tumor response was 16% partial response, 66% stable disease, and 19% progressive disease. The median PFS and OS were 29 months and 47 months, respectively, and were significantly associated with kidney dose, performance status, and Ki 67 levels but not with tumor origin. The overall toxicity was mild, and the most common events were grade 1-2 anemia, thrombocytopenia, fatigue, nausea, and diarrhea. Grade 3-4 toxicity occurred in < 10% of patients and was mostly hematological, with no grade 3-4 renal toxicity. CONCLUSION: Individualized treatment with 177Lu-DOTATATE based on renal dosimetry is clearly feasible with low toxicity and promising efficacy, showing the potential to further improve outcome beyond the standard approach, and should be further assessed in randomized trials. TRIAL REGISTRATION: EudraCT 2011-000,240-16. NCT01456078. https://clinicaltrials.gov/ct2/show/NCT01456078.


Asunto(s)
Tumores Neuroendocrinos , Compuestos Organometálicos , Humanos , Antígeno Ki-67 , Tumores Neuroendocrinos/patología , Octreótido/efectos adversos , Compuestos Organometálicos/efectos adversos , Tomografía de Emisión de Positrones , Cintigrafía , Radiofármacos/uso terapéutico , Receptores de Somatostatina/uso terapéutico
3.
Artículo en Japonés | MEDLINE | ID: mdl-33473078

RESUMEN

Validation study of simulation codes was performed based on the measurement of a sphere phantom and the National Electrical Manufacturers Association (NEMA) body phantoms. SIMIND and Prominence Processor were used for the simulation. Both source and density maps were generated using the characteristics of 99mTc energy. A full width at half maximum (FWHM) of the sphere phantom was measured and simulated. Simulated recovery coefficient and the background count coefficient of variation were also compared with the measured values in the body phantom study. When the two simulation codes were compared with actual measurements, maximum relative errors of FWHM values were 3.6% for Prominence Processor and -10.0% for SIMIND. The maximum relative errors of relative recovery coefficients exhibited 11.8% for Prominence Processor and -2.0% for SIMIND in the body phantom study. The coefficients of variation of the SPECT count in the background were significantly different among the measurement and two simulation codes. The simulated FWHM values and recovery coefficients paralleled measured results. However, the noise characteristic differed among actual measurements and two simulation codes in the background count statistics.


Asunto(s)
Tomografía Computarizada de Emisión de Fotón Único , Simulación por Computador , Fantasmas de Imagen
4.
Eur J Nucl Med Mol Imaging ; 44(9): 1480-1489, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28331954

RESUMEN

PURPOSE: To present data from an interim analysis of a Phase II trial designed to determine the feasibility, safety, and efficacy of individualising treatment based on renal dosimetry, by giving as many cycles as possible within a maximum renal biologically effective dose (BED). METHOD: Treatment was given with repeated cycles of 7.4 GBq 177Lu-DOTATATE at 8-12-week intervals. Detailed dosimetry was performed in all patients after each cycle using a hybrid method (SPECT + planar imaging). All patients received treatment up to a renal BED of 27 ± 2 Gy (α/ß = 2.6 Gy) (Step 1). Selected patients were offered further treatment up to a renal BED of 40 ± 2 Gy (Step 2). Renal function was followed by estimation and measurement of the glomerular filtration rate (GFR). RESULTS: Fifty-one patients were included in the present analysis. Among the patients who received treatment as planned, the median number of cycles in Step 1 was 5 (range 3-7), and for those who completed Step 2 it was 7 (range 5-8); 73% were able to receive >4 cycles. Although GFR decreased in most patients after the completion of treatment, no grade 3-4 toxicity was observed. Patients with a reduced baseline GFR seemed to have an increased risk of GFR decline. Five patients received treatment in Step 2, none of whom exhibited a significant reduction in renal function. CONCLUSIONS: Individualising PRRT using renal dosimetry seems feasible and safe and leads to an increased number of cycles in the majority of patients. The trial will continue as planned.


Asunto(s)
Riñón/efectos de la radiación , Tumores Neuroendocrinos/radioterapia , Octreótido/análogos & derivados , Compuestos Organometálicos/uso terapéutico , Medicina de Precisión , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Octreótido/uso terapéutico , Radiometría
5.
Eur J Nucl Med Mol Imaging ; 42(12): 1929-40, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26290421

RESUMEN

Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/publications/guidelines/2015_07_EANM_FINAL_myocardial_perfusion_guideline.pdf .


Asunto(s)
Imagen de Perfusión Miocárdica/métodos , Guías de Práctica Clínica como Asunto , Sociedades Médicas , Tomografía Computarizada por Rayos X/métodos , Adulto , Medios de Contraste , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Relación Dosis-Respuesta a Droga , Ejercicio Físico , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Imagen Multimodal , Imagen de Perfusión Miocárdica/efectos adversos , Imagen de Perfusión Miocárdica/instrumentación , Purinas/efectos adversos , Purinas/farmacología , Pirazoles/efectos adversos , Pirazoles/farmacología , Exposición a la Radiación , Seguridad , Programas Informáticos , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/instrumentación , Vasodilatadores/efectos adversos , Vasodilatadores/farmacología
6.
Br J Nutr ; 111(3): 547-53, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23930999

RESUMEN

Se metabolism in humans is not well characterised. Currently, the estimates of Se absorption, whole-body retention and excretion are being obtained from balance and tracer studies. In the present study, we used gamma camera imaging to evaluate the whole-body retention and distribution of radiolabelled selenomethionine (SeMet), the predominant form of Se present in foods. A total of eight healthy young men participated in the study. After consumption of a meal containing 4 MBq [75Se]L-SeMet ([75Se]SeMet), whole-body gamma camera scanning was performed for 45 min every hour over a 6 h period, every second hour for the next 18 h and once on each of the subsequent 6 d. Blood, urine and faecal samples were collected to determine the plasma content of [75Se]SeMet as well as its excretion in urine and faeces. Imaging showed that 87·9 (sd 3·3)% of the administered activity of [75Se]SeMet was retained within the body after 7 d. In contrast, the measured excretion in urine and faeces for the 7 d period was 8·2 (sd 1·1)% of the activity. Time-activity curves were generated for the whole body, stomach, liver, abdomen (other than the stomach and the liver), brain and femoral muscles. Gamma camera imaging allows for the assessment of the postprandial absorption of SeMet. This technique may also permit concurrent studies of organ turnover of SeMet.


Asunto(s)
Absorción Intestinal , Modelos Biológicos , Radiofármacos/farmacocinética , Selenio/metabolismo , Selenometionina/farmacocinética , Adulto , Heces/química , Cámaras gamma , Humanos , Masculino , Periodo Posprandial , Cintigrafía , Radiofármacos/análisis , Radiofármacos/sangre , Radiofármacos/orina , Radioisótopos de Selenio , Selenometionina/análisis , Selenometionina/sangre , Selenometionina/orina , Distribución Tisular , Imagen de Cuerpo Entero
7.
J Nucl Cardiol ; 21(3): 503-18, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24532031

RESUMEN

BACKGROUND: Myocardial perfusion SPECT (MPS) is one of the frequently used methods for quantification of perfusion defects in patients with known or suspected coronary artery disease. This article describes open access software for automated quantification in MPS of stress-induced ischemia and infarction and provides phantom and in vivo validation. METHODS AND RESULTS: A total of 492 patients with known or suspected coronary artery disease underwent both stress and rest MPS. The proposed perfusion analysis algorithm (Segment) was trained in 140 patients and validated in the remaining 352 patients using visual scoring in MPS by an expert reader as reference standard. Furthermore, validation was performed with simulated perfusion defects in an anthropomorphic computer model. Total perfusion deficit (TPD, range 0-100), including both extent and severity of the perfusion defect, was used as the global measurement of the perfusion defects. Mean bias ± SD between TPD by Segment and the simulated TPD was 3.6 ± 3.8 (R(2) = 0.92). Mean bias ± SD between TPD by Segment and the visual scoring in the patients was 1.2 ± 2.9 (R (2)= 0.64) for stress-induced ischemia and -0.3 ± 3.1 (R(2) = 0.86) for infarction. CONCLUSION: The proposed algorithm can detect and quantify perfusion defects in MPS with good agreement to expert readers and to simulated values in a computer phantom.


Asunto(s)
Inteligencia Artificial , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Infarto del Miocardio/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Algoritmos , Enfermedad de la Arteria Coronaria/complicaciones , Prueba de Esfuerzo/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Método Simple Ciego
8.
World J Nucl Med ; 23(2): 95-102, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38933066

RESUMEN

Objectives The purpose of a parallel-hole collimator in a scintillation camera system is to transmit only those photons that have an emission angle close to the direction of the hole. This makes it possible to receive spatial information about the origin of the emission, that is, radioactivity decay. The dimension, shape, and intrahole thickness determine the spatial resolution and, by a tradeoff, sensitivity. The composition of the collimator material also plays an important role in determining a proper collimator. In this study, we compared tungsten alloys as a potential collimator material replacement for the conventional lead antimony material used in most of the current camera systems. Materials and Methods Monte Carlo simulations of a commercial scintillation camera system with low energy high resolution (LEHR), medium-energy (ME), and high-energy (HE) collimators of lead, tungsten, and tungsten-based alloy were simulated for different I-131, Lu-177, I-123, and Tc-99m sources, and a Deluxe rod phantom using the SIMIND Monte Carlo code. Planar images were analyzed regarding spatial resolution, image contrast in a cold source case, and system sensitivity for each collimator configuration. The hole dimensions for the three collimators were those specified in the vendor's datasheet. Results Using Pb, W, and tungsten alloy (Wolfmet) as collimator materials, the full width at half maximum (FWHM) measures for total counts (T) for LEHR with Tc-99m source (6.9, 6.8, and 6.8 mm), for ME with Lu-177 source (11.7, 11.5, and 11.6 mm), and for HE with I-131 (6.2, 13.1, and 13.1 mm) were obtained, and the system sensitivities were calculated as 89.9, 86.1, and 89.8 cps T /MBq with Tc-99m source; 42.7, 17.4, and 20.9 cps T /MBq with Lu-177 source; and 40.1, 69.7, and 77.4 cps T /MBq with I-131 source. The collimators of tungsten and tungsten alloy (97.0% W, 1.5% Fe, 1.5% Ni) provided better spatial resolution and improved image contrast when compared with conventional lead-based collimators. This was due to lower septal penetration. Conclusion The results suggest that development of a new set of ME and HE tungsten and tungsten alloy collimators could improve imaging of I-131, Lu-177, and I-123.

9.
EJNMMI Phys ; 11(1): 62, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39004644

RESUMEN

BACKGROUND: The aim was to investigate the noise and bias properties of quantitative 177Lu-SPECT with respect to the number of projection angles, and the number of subsets and iterations in the OS-EM reconstruction, for different total acquisition times. METHODS: Experimental SPECT acquisition of six spheres in a NEMA body phantom filled with 177Lu was performed, using medium-energy collimators and 120 projections with 180 s per projection. Bootstrapping was applied to generate data sets representing acquisitions with 20 to 120 projections for 10 min, 20 min, and 40 min, with 32 noise realizations per setting. Monte Carlo simulations were performed of 177Lu-DOTA-TATE in an anthropomorphic computer phantom with three tumours (2.8 mL to 40.0 mL). Projections representing 24 h and 168 h post administration were simulated, each with 32 noise realizations. Images were reconstructed using OS-EM with compensation for attenuation, scatter, and distance-dependent resolution. The number of subsets and iterations were varied within a constrained range of the product number of iterations × number of projections ≤ 2400 . Volumes-of-interest were defined following the physical size of the spheres and tumours, the mean activity-concentrations estimated, and the absolute mean relative error and coefficient of variation (CV) over noise realizations calculated. Pareto fronts were established by analysis of CV versus mean relative error. RESULTS: Points at the Pareto fronts with low CV and high mean error resulted from using a low number of subsets, whilst points at the Pareto fronts associated with high CV but low mean error resulted from reconstructions with a high number of subsets. The number of projection angles had limited impact. CONCLUSIONS: For accurate estimation of the 177Lu activity-concentration from SPECT images, the number of projection angles has limited importance, whilst the total acquisition time and the number of subsets and iterations are parameters of importance.

10.
EJNMMI Phys ; 11(1): 2, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38167976

RESUMEN

BACKGROUND: In image processing for activity quantification, the end goal is to produce a metric that is independent of the measurement geometry. Photon attenuation needs to be accounted for and can be accomplished utilizing spectral information, avoiding the need of additional image acquisitions. The aim of this work is to investigate the feasibility of 177Lu activity quantification with a small CZT-based hand-held gamma-camera, using such an attenuation correction method. METHODS: A previously presented dual photopeak method, based on the differential attenuation for two photon energies, is adapted for the three photopeaks at 55 keV, 113 keV, and 208 keV for 177Lu. The measurement model describes the count rates in each energy window as a function of source depth and activity, accounting for distance-dependent system sensitivity, attenuation, and build-up. Parameter values are estimated from characterizing measurements, and the source depth and activity are obtained by minimizing the difference between measured and modelled count rates. The method is applied and evaluated in phantom measurements, in a clinical setting for superficial lesions in two patients, and in a pre-clinical setting for one human tumour xenograft. Evaluation is made for a LEHR and an MEGP collimator. RESULTS: For phantom measurements at clinically relevant depths, the average (and standard deviation) in activity errors are 17% ± 9.6% (LEHR) and 2.9% ± 3.6% (MEGP). For patient measurements, deviations from activity estimates from planar images from a full-sized gamma-camera are 0% ± 21% (LEHR) and 16% ± 18% (MEGP). For mouse measurements, average deviations of - 16% (LEHR) and - 6% (MEGP) are obtained when compared to a small-animal SPECT/CT system. The MEGP collimator appears to be better suited for activity quantification, yielding a smaller variability in activity estimates, whereas the LEHR results are more severely affected by septal penetration. CONCLUSIONS: Activity quantification for 177Lu using the hand-held camera is found to be feasible. The readily available nature of the hand-held camera may enable more frequent activity quantification in e.g., superficial structures in patients or in the pre-clinical setting.

11.
EJNMMI Phys ; 11(1): 8, 2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38252205

RESUMEN

BACKGROUND: A 3D printing grid-based method was developed to construct anthropomorphic phantoms with non-uniform activity distributions, to be used for evaluation of quantitative SPECT images. The aims were to characterize the grid-based method and to evaluate its capability to provide realistically shaped phantoms with non-uniform activity distributions. METHODS: Characterization of the grid structures was performed by printing grid-filled spheres. Evaluation was performed by micro-CT imaging to investigate the printing accuracy and by studying the modulation contrast ([Formula: see text]) in SPECT images for 177Lu and 99mTc as a function of the grid fillable-volume fraction (FVF) determined from weighing. The grid-based technique was applied for the construction of two kidney phantoms and two thyroid phantoms, designed using templates from the XCAT digital phantoms. The kidneys were constructed with a hollow outer container shaped as cortex, an inner grid-based structure representing medulla and a solid section representing pelvis. The thyroids consisted of two lobes printed as grid-based structures, with void hot spots within the lobes. The phantoms were filled with solutions of 177Lu (kidneys) or 99mTc (thyroids) and imaged with SPECT. For verification, Monte Carlo simulations of SPECT imaging were performed for activity distributions corresponding to those of the printed phantoms. Measured and simulated SPECT images were compared qualitatively and quantitatively. RESULTS: Micro-CT images showed that printing inaccuracies were mainly uniform across the grid. The relationships between the FVF from weighing and [Formula: see text] were found to be linear (r = 0.9995 and r = 0.9993 for 177Lu and 99mTc, respectively). The FVF-deviations from the design were up to 15% for thyroids and 4% for kidneys, mainly related to possibilities of cleaning after printing. Measured and simulated SPECT images of kidneys and thyroids exhibited similar activity distributions and quantitative comparisons agreed well, thus verifying the grid-based method. CONCLUSIONS: We find the grid-based technique useful for the provision of 3D printed, realistically shaped, phantoms with non-uniform activity distributions, which can be used for evaluation of different quantitative methods in SPECT imaging.

12.
EJNMMI Phys ; 11(1): 50, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38898326

RESUMEN

PURPOSE: This study aimed to assess the accuracy of patient-specific absorbed dose calculations for tumours and organs at risk in radiopharmaceutical therapy planning, utilizing hybrid planar-SPECT/CT imaging. METHODS: Three Monte Carlo (MC) simulated digital patient phantoms were created, with time-activity data for mIBG labelled to I-123 (LEHR and ME collimators) and I-131 (HE collimator). The study assessed the accuracy of the mean absorbed doses for I-131-mIBG therapy treatment planning. Multiple planar whole-body (WB) images were simulated (between 1 to 72 h post-injection (p.i)). The geometric-mean image of the anterior and posterior WB images was calculated, with scatter and attenuation corrections applied. Time-activity curves were created for regions of interest over the liver and two tumours (diameters: 3.0 cm and 5.0 cm) in the WB images. A corresponding SPECT study was simulated at 24 h p.i and reconstructed using the OS-EM algorithm, incorporating scatter, attenuation, collimator-detector response, septal scatter and penetration corrections. MC voxel-based absorbed dose rate calculations used two image sets, (i) the activity distribution represented by the SPECT images and (ii) the activity distribution from the SPECT images distributed uniformly within the volume of interest. Mean absorbed doses were calculated considering photon and charged particle emissions, and beta emissions only. True absorbed doses were calculated by MC voxel-based dosimetry of the known activity distributions for reference. RESULTS: Considering photon and charged particle emissions, mean absorbed dose accuracies across all three radionuclide-collimator combinations of 3.8 ± 5.5% and 0.1 ± 0.9% (liver), 5.2 ± 10.0% and 4.3 ± 1.7% (3.0 cm tumour) and 15.0 ± 5.8% and 2.6 ± 0.6% (5.0 cm tumour) were obtained for image set (i) and (ii) respectively. Considering charged particle emissions, accuracies of 2.7 ± 4.1% and 5.7 ± 0.7% (liver), 3.2 ± 10.2% and 9.1 ± 1.7% (3.0 cm tumour) and 13.6 ± 5.7% and 7.0 ± 0.6% (5.0 cm tumour) were obtained for image set (i) and (ii) respectively. CONCLUSION: The hybrid WB planar-SPECT/CT method proved accurate for I-131-mIBG dosimetry, suggesting its potential for personalized treatment planning.

13.
World J Nucl Med ; 22(3): 217-225, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37854088

RESUMEN

Objectives Collimators have a significant role in image quality and detectability in single-photon emission computed tomography (SPECT) imaging. Using an appropriate alloy that effectively absorbs scattered photons, without induced secondary x-rays, and with proper rigidity and weight may provide an effective approach to the image improvement that conventionally collimators made of lead (Pb). Materials and Methods A Siemens E.CAM SPECT imaging system equipped with low-energy high-resolution (LEHR) collimator was simulated by the Simulating Medical Imaging Nuclear Detectors Monte Carlo program. Experimental and simulated data were compared based on a 2-mm 99m Tc point source in an acrylic cylindrical Deluxe phantom (Data Spectrum, Inc). Seven types of tungsten (W) alloys (Wolfmet), with W content from 90 to 97% by weight, were then used as collimator materials of the simulated system. Camera parameters, such as energy- and spatial resolution, image contrast, and collimator-related parameters, such as fraction of septal penetration, scatter-to-primary ratios, and percentage of induced secondary x-rays, due to interactions in the collimator, were evaluated. Results Acceptable conformity was found for the simulated and experiment systems in terms of energy spectra, 10.113 and 10.140%, full width at half-maximum (FWHM) of the point spread function (PSF) curves, 8.78 and 9.06 mm, sensitivity, 78.46 and 78.34 cps/MBq, and contrast in images of 19.1 mm cold spheres in the Deluxe phantom, 79.17 and 78.97%, respectively. Results on the parameters of the simulated system with LEHR collimator made from the alloys showed that the alloy consisting of 90% W, 6% nickel, and 4% copper provided an FWHM of 8.76 mm, resulting in a 0.2% improvement in spatial resolution. Furthermore, all the Wolfmet collimators showed a 48% reduction in the amount of X-rays production compared to the Pb. Conclusion A Wolfmet LEHR collimator, made by a combination of W (90%), Ni (6%), and Cu (6%) provides a better image quality and detectability compared to the Pb.

14.
Heliyon ; 9(9): e19504, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37681181

RESUMEN

One example of a PET exam that suffers from noise problems is [68Ga]Ga-DOTA-TOC, where patients are generally administered between 100 and 200 MBq [68Ga]Ga-DOTA-TOC, irrespective of size. However, a fixed activity can result in low signal-to-noise ratios (SNRs) in larger patients. This study aimed to evaluate the impact on image quality with respect to injected activity and patient habitus through Monte Carlo (MC) simulation. Eight anthropomorphic computer phantoms with body mass indices (BMIs) between 19 kg/m2 and 38 kg/m2 and tumours distributed in the liver were simulated using the MC software Gate v8.2 with an activity distribution defined according to [68Ga]Ga-DOTA-TOC standardised uptake values. Three activity-administration protocols were simulated: (i) with a fixed activity of 100 MBq, (ii) with the activity scaled by 2 MBq/kg, and (iii) with the activity scaled by a body size-dependent power-function based on the SNR obtained with (ii). BMI, weight, body surface area, and abdominal circumference were evaluated body size parameters. Images were reconstructed with the CASToR software and evaluated for background SNR and lesion contrast-to-noise ratio (CNR). Large SNR variabilities were obtained with protocols (i) and (ii), while (iii) generated good consistency. Several tumours failed to reach a CNR of 5 for large phantoms with protocol (i), but the CNR was generally improved by (ii) and (iii). An activity scaled by patient habitus generate better image quality consistency, which increases the likelihood that patients receive a similar standard of care.

15.
Med Phys ; 50(10): 6600-6613, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37272586

RESUMEN

BACKGROUND: Dosimetry in radionuclide therapy often requires the calculation of average absorbed doses within and between spatial regions, for example, for voxel-based dosimetry methods, for paired organs, or across multiple tumors. Formation of such averages can be made in different ways, starting from different definitions. PURPOSE: The aim of this study is to formally specify different averaging strategies for absorbed doses, and to compare their results when applied to absorbed dose distributions that are non-uniform within and between regions. METHODS: For averaging within regions, two definitions of the average absorbed dose are considered: the simple average over the region (the region average) and the average when weighting by the mass density (density-weighted region average). The latter is shown to follow from the definition of mean absorbed dose according to the ICRU, and to be consistent with the MIRD formalism. For averaging between different spatial regions, three definitions follow: the volume-weighted, the mass-weighted, and the unweighted average. With respect to characterizing non-uniformity, the different average definitions lead to the use of dose-volume histograms (DVHs) (region average), dose-mass histograms (DMHs) (density-weighted region average), and unweighted histograms (unweighted average). Average absorbed doses are calculated for three worked examples, starting from the different definitions. The first, schematic, example concerns the calculation of the average absorbed dose between two regions with different volumes or mass densities. The second, stylized, example concerns voxel-based dosimetry, for which the average absorbed-dose rate within a region is calculated. The geometries studied include three 177 Lu-filled voxelized spheres, where the sphere masses are held constant while the material compositions, densities, and volumes are varied. For comparison, the mean absorbed-dose rates obtained using unit-density sphere S-values are also included. The third example concerns SPECT/CT-based tumor dosimetry for five patients undergoing therapy with 177 Lu-PSMA and six patients undergoing therapy with 177 Lu-DOTA-TATE, for which the average absorbed-dose rates across multiple tumors are calculated. For the second and third examples, analyses also include representations by histograms. RESULTS: Example 1 shows that the average absorbed doses, calculated using different definitions, can differ considerably if the masses and absorbed doses for two regions are markedly different. From example 2 it is seen that the density-weighted region average is stable under different activity and density distributions and is also in line with results using S-values. In contrast, the region average varies as function of the activity distribution. In example 3, the absorbed dose rates for individual tumors differ by (1.1 ± 4.3)% and (-0.1 ± 0.4)% with maximum deviations of +34.4% and -1.4% for 177 Lu-PSMA and 177 Lu-DOTA-TATE, respectively, when calculated as region averages or density-weighted region averages, with largest deviations obtained when the density is non-uniform. The average absorbed doses calculated across all tumors are similar when comparing mass-weighted and volume-weighted averages but these differ substantially from unweighted averages. CONCLUSION: Different strategies for averaging of absorbed doses within and between regions can lead to substantially different absorbed-dose estimates. At reporting of radionuclide therapy dosimetry, it is important to specify the averaging strategy applied.


Asunto(s)
Neoplasias , Radiofármacos , Humanos , Radiometría/métodos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos
16.
IEEE Trans Radiat Plasma Med Sci ; 7(8): 839-850, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38745858

RESUMEN

SPECT systems distinguish radionuclides by using multiple energy windows. For CZT detectors, the energy spectrum has a low energy tail leading to additional crosstalk between the radionuclides. Previous work developed models to correct the scatter and crosstalk for CZT-based dedicated cardiac systems with similar 99mTc/123I tracer distributions. These models estimate the primary and scatter components by solving a set of equations employing the MLEM approach. A penalty term is applied to ensure convergence. The present work estimates the penalty term for any 99mTc/123I activity level. An iterative approach incorporating Monte Carlo into the iterative image reconstruction loops was developed to estimate the penalty terms. We used SIMIND and XCAT phantoms in this study. Distribution of tracers in the myocardial tissue and blood pool were varied to simulate a dynamic acquisition. Evaluations of the estimated and the real penalty terms were performed using simulations and large animal data. The myocardium to blood pool ratio was calculated using ROIs in the myocardial tissue and the blood pool for quantitative analysis. All corrected images yielded a good agreement with the gold standard images. In conclusion, we developed a CZT crosstalk correction method for quantitative imaging of 99mTc/123I activity levels by dynamically estimating the penalty terms.

17.
EJNMMI Phys ; 10(1): 73, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37993667

RESUMEN

INTRODUCTION: Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. MATERIALS AND METHODS: Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68-107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. RESULTS: As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12-1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. CONCLUSION: This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.

18.
Med Phys ; 39(5): 2346-58, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22559605

RESUMEN

PURPOSE: Yttrium-90 ((90)Y) is one of the most commonly used radionuclides in targeted radionuclide therapy (TRT). Since it decays with essentially no gamma photon emissions, surrogate radionuclides (e.g., (111)In) or imaging agents (e.g., (99m)Tc MAA) are typically used for treatment planning. It would, however, be useful to image (90)Y directly in order to confirm that the distributions measured with these other radionuclides or agents are the same as for the (90)Y labeled agents. As a result, there has been a great deal of interest in quantitative imaging of (90)Y bremsstrahlung photons using single photon emission computed tomography (SPECT) imaging. The continuous and broad energy distribution of bremsstrahlung photons, however, imposes substantial challenges on accurate quantification of the activity distribution. The aim of this work was to develop and evaluate an improved quantitative (90)Y bremsstrahlung SPECT reconstruction method appropriate for these imaging applications. METHODS: Accurate modeling of image degrading factors such as object attenuation and scatter and the collimator-detector response is essential to obtain quantitatively accurate images. All of the image degrading factors are energy dependent. Thus, the authors separated the modeling of the bremsstrahlung photons into multiple categories and energy ranges. To improve the accuracy, the authors used a bremsstrahlung energy spectrum previously estimated from experimental measurements and incorporated a model of the distance between (90)Y decay location and bremsstrahlung emission location into the SIMIND code used to generate the response functions and kernels used in the model. This improved Monte Carlo bremsstrahlung simulation was validated by comparison to experimentally measured projection data of a (90)Y line source. The authors validated the accuracy of the forward projection model for photons in the various categories and energy ranges using the validated Monte Carlo (MC) simulation method. The forward projection model was incorporated into an iterative ordered subsets-expectation maximization (OS-EM) reconstruction code to allow for quantitative SPECT reconstruction. The resulting code was validated using both a physical phantom experiment with spherical objects in a warm background and a realistic anatomical phantom simulation. In the physical phantom study, the authors evaluated the method in terms of quantitative accuracy of activity estimates in the spheres; in the simulation study, the authors evaluated the accuracy and precision of activity estimates from various organs and compared them to results from a previously proposed method. RESULTS: The authors demonstrated excellent agreement between the experimental measurement and Monte Carlo simulation. In the XCAT phantom simulation, the proposed method achieved much better accuracy in the modeling (error in photon counts was -1.1 %) compared to a previously proposed method (errors were more than 20 %); the quantitative accuracy of activity estimates was excellent for all organs (errors were from -1.6 % to 11.9 %) and comparable to previously published results for (131)I using the same collimator. CONCLUSIONS: The proposed (90)Y bremsstrahlung SPECT reconstruction method provided very accurate estimates of organ activities, with accuracies approaching those previously observed for (131)I. The method may be useful in verifying organ doses for targeted radionuclide therapy using (90)Y.


Asunto(s)
Tomografía Computarizada de Emisión de Fotón Único/métodos , Método de Montecarlo , Fantasmas de Imagen , Fotones , Radiometría , Reproducibilidad de los Resultados , Dispersión de Radiación , Radioisótopos de Itrio
19.
Med Phys ; 39(7): 4434-43, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22830776

RESUMEN

PURPOSE: Biokinetic and dosimetry studies in laboratory animals often precede clinical radionuclide therapies in humans. A reliable evaluation of therapeutic efficacy is essential and should be based on accurate dosimetry data from a realistic dosimetry model. The aim of this study was to develop an anatomically realistic dosimetry model for Brown Norway rats to calculate S factors for use in evaluating correlations between absorbed dose and biological effects in a preclinical therapy study. METHODS: A realistic rat phantom (Roby) was used, which has some flexibility that allows for a redefinition of organ sizes. The phantom was modified to represent the anatomic geometry of a Brown Norway rat, which was used for Monte Carlo calculations of S factors. Kinetic data for radiolabeled BR96 monoclonal antibodies were used to calculate the absorbed dose. Biological data were gathered from an activity escalation study with (90)Y- and (177)Lu-labeled BR96 monoclonal antibodies, in which blood cell counts and bodyweight were examined up to 2 months follow-up after injection. Reductions in white blood cell and platelet counts and declines in bodyweight were quantified by four methods and compared to the calculated absorbed dose to the bone marrow or the total body. RESULTS: A red marrow absorbed dose-dependent effect on hematological parameters was observed, which could be evaluated by a decrease in blood cell counts. The absorbed dose to the bone marrow, corresponding to the maximal tolerable activity that could safely be administered, was determined to 8.3 Gy for (177)Lu and 12.5 Gy for (90)Y. CONCLUSIONS: There was a clear correlation between the hematological effects, quantified with some of the studied parameters, and the calculated red marrow absorbed doses. The decline in body weight was stronger correlated to the total body absorbed dose, rather than the red marrow absorbed dose. Finally, when considering a constant activity concentration, the phantom weight, ranging from 225 g to 300 g, appeared to have no substantial effect for the estimated absorbed dose.


Asunto(s)
Anticuerpos Monoclonales/farmacocinética , Médula Ósea/metabolismo , Médula Ósea/efectos de la radiación , Sistema Hematopoyético/metabolismo , Sistema Hematopoyético/efectos de la radiación , Lutecio/farmacocinética , Modelos Biológicos , Radioisótopos/farmacocinética , Animales , Materiales Biomiméticos , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Tasa de Depuración Metabólica , Modelos Estadísticos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiofármacos/farmacocinética , Ratas , Estadística como Asunto , Radioisótopos de Itrio/farmacocinética
20.
Heliyon ; 8(4): e09316, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35520630

RESUMEN

The study aimed to create a pipeline from Monte Carlo simulated projections of a Gate PET system to reconstructed images. The PET system was modelled after the GE Discovery MI (DMI) PET/CT, and the simulated projections were reconstructed with the stand-alone reconstruction software CASToR. Attenuation correction, normalisation calibration, random estimation, and scatter estimation for the simulations were computed with in-house programs. The pipeline was compared in both projection and image space with data acquired on a clinical DMI and reconstructed with GE's off-line PET reconstruction software (PET Toolbox) and CASToR. The simulated and measured data were compared for the number of prompt coincidences, scatter fraction, contrast recovery coefficient (CRC), signal-to-noise ratio (SNR), background variability, residual lung error, and image profiles. A slight discrepancy was noted in the projection space, but good agreements were generally achieved in image space between simulated and measured data. The CRC was found to be 81 % for Gate - CASToR, 84 % for GE - CASToR, and 84 % for GE - PET Toolbox for the largest sphere of the NEMA image quality (IQ) phantom, and the SNR was found to be 98 for Gate - CASToR, 91 for GE - CASToR, and 93 for GE - PET Toolbox. Profiles drawn over the spheres for the NEMA IQ phantom and the Data Spectrum (DS) phantom show a good match between measurement and simulation. The results indicate feasibility to utilise the pipeline as a tool for off-line simulation-based studies. A complete pipeline introduces possibilities to study the impact of single parameters in the whole chain from simulation to reconstructed images.