Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Endocrine ; 2024 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-39375254

RESUMEN

PURPOSE: Thyroid nodules are highly prevalent in the general population, posing a clinical challenge in accurately distinguishing between benign and malignant cases. This study aimed to investigate the diagnostic performance of different strategies, utilizing a combination of a computer-aided diagnosis system (AmCAD) and shear wave elastography (SWE) imaging, to effectively differentiate benign and malignant thyroid nodules in ultrasonography. METHODS: A total of 126 thyroid nodules with pathological confirmation were prospectively included in this study. The AmCAD was utilized to analyze the ultrasound imaging characteristics of the nodules, while the SWE was employed to measure their stiffness in both transverse and longitudinal thyroid scans. Twelve diagnostic patterns were formed by combining AmCAD diagnosis and SWE values, including isolation, series, parallel, and integration. The diagnostic performance was assessed using the receiver operating characteristic curve and area under the curve (AUC). Sensitivity, specificity, accuracy, missed malignancy rate, and unnecessary biopsy rate were also determined. RESULTS: Various diagnostic schemes have shown specific advantages in terms of diagnostic performance. Overall, integrating AmCAD with SWE imaging in the transverse scan yielded the most favorable diagnostic performance, achieving an AUC of 72.2% (95% confidence interval (CI): 63.0-81.5%), outperforming other diagnostic schemes. Furthermore, in the subgroup analysis of nodules measuring <2 cm or 2-4 cm, the integrated scheme consistently exhibited promising diagnostic performance, with AUCs of 74.2% (95% CI: 61.9-86.4%) and 77.4% (95% CI: 59.4-95.3%) respectively, surpassing other diagnostic schemes. The integrated scheme also effectively addressed thyroid nodule management by reducing the missed malignancy rate to 9.5% and unnecessary biopsy rate to 22.2%. CONCLUSION: The integration of AmCAD and SWE imaging in the transverse thyroid scan significantly enhances the diagnostic performance for distinguishing benign and malignant thyroid nodules. This strategy offers clinicians the advantage of obtaining more accurate clinical diagnoses and making well-informed decisions regarding patient management.

2.
Endocrine ; 2024 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-39394537

RESUMEN

PURPOSE: Large language models (LLMs) are pivotal in artificial intelligence, demonstrating advanced capabilities in natural language understanding and multimodal interactions, with significant potential in medical applications. This study explores the feasibility and efficacy of LLMs, specifically ChatGPT-4o and Claude 3-Opus, in classifying thyroid nodules using ultrasound images. METHODS: This study included 112 patients with a total of 116 thyroid nodules, comprising 75 benign and 41 malignant cases. Ultrasound images of these nodules were analyzed using ChatGPT-4o and Claude 3-Opus to diagnose the benign or malignant nature of the nodules. An independent evaluation by a junior radiologist was also conducted. Diagnostic performance was assessed using Cohen's Kappa and receiver operating characteristic (ROC) curve analysis, referencing pathological diagnoses. RESULTS: ChatGPT-4o demonstrated poor agreement with pathological results (Kappa = 0.116), while Claude 3-Opus showed even lower agreement (Kappa = 0.034). The junior radiologist exhibited moderate agreement (Kappa = 0.450). ChatGPT-4o achieved an area under the ROC curve (AUC) of 57.0% (95% CI: 48.6-65.5%), slightly outperforming Claude 3-Opus (AUC of 52.0%, 95% CI: 43.2-60.9%). In contrast, the junior radiologist achieved a significantly higher AUC of 72.4% (95% CI: 63.7-81.1%). The unnecessary biopsy rates were 41.4% for ChatGPT-4o, 43.1% for Claude 3-Opus, and 12.1% for the junior radiologist. CONCLUSION: While LLMs such as ChatGPT-4o and Claude 3-Opus show promise for future applications in medical imaging, their current use in clinical diagnostics should be approached cautiously due to their limited accuracy.

3.
Biomedicines ; 10(7)2022 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-35884858

RESUMEN

This study investigated the diagnostic value of the Angio Planewave Ultrasensitive (AngioPLUS) Doppler ultrasound in improving the efficacy of grey scale ultrasound in thyroid nodule diagnosis. The EU TIRADS was used for the grey scale ultrasound assessment of 94 thyroid nodules. conventional Doppler and AngioPLUS Doppler ultrasound images were evaluated using qualitative vascularity grading, where predominant central vascularity indicated malignancy-suspicion, and quantitative regional vascularity assessment, where predominant peripheral vascularity using a ratio vascularity index (RVI) of > 1 indicated benign disease. Diagnostic performance outcomes of sole and combination approaches were calculated based on final pathologic results. Using sole EU TIRADS and AngioPLUS + power Doppler imaging (APDI) based on qualitative vascularity and RVI, the results were a sensitivity of 83.3% vs. 83.3 vs. 66.7% and a specificity of 50% vs. 81.3% vs. 73.4, respectively. EU TIRADS combined with APDI significantly improved the specificity using both qualitative vascularity and RVI assessment approaches (84.4% and 81%, respectively, p < 0.05); and slightly reduced the sensitivity (76.7% and 58.1%). For cytologically-equivocal thyroid nodules, the combination approach using qualitative vascularity assessment outperformed the EU TIRADS (sensitivity: both were 88.9%; specificity: 77.4% vs. 38.7%, p < 0.05; and AUROC: 0.83 vs. 0.62, p < 0.05). APDI combined with EU TIRADS is diagnostically efficient in stratifying thyroid nodules, particularly cytologically-equivocal nodules.

4.
Cancers (Basel) ; 14(22)2022 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-36428614

RESUMEN

Although multimodal ultrasound approaches have been suggested to potentially improve the diagnosis of thyroid cancer; the diagnostic utility of the combination of SWE and malignancy-risk stratification systems remains vague due to the lack of standardized criteria. The purpose of the study was to assess the diagnostic value of the combination of grey scale ultrasound assessment using EU TIRADS and shear wave elastography. 121 patients (126 nodules−81 benign; 45 malignant) underwent grey scale ultrasound and SWE imaging of nodules between 0.5 cm and 5 cm prior to biopsy and/or surgery. Nodules were analyzed based on size stratifications: <1 cm (n = 43); 1−2 cm (n = 52) and >2 cm (n = 31) and equivocal cytology status (n = 52), and diagnostic performance assessments were conducted. The combination of EU TIRADS with SWE using the SD parameter; maintained a high sensitivity and significantly improved the specificity of sole EU TIRADS for nodules 1−2 cm (SEN: 72.2% vs. 88.9%, p > 0.05; SPEC: 76.5% vs. 55.9%, p < 0.01) and >2 cm (SEN: 71.4% vs. 85.7%, p > 0.05; SPEC: 95.8% vs. 62.5%, p < 0.01). For cytologically-equivocal nodules; the combination with the SWE minimum parameter resulted in a significant reduction in sensitivity with increased specificity (SEN: 60% vs. 80%; SPEC: 83.4% vs. 37.8%; all p < 0.05). SWE in combination with EU TIRADS is diagnostically efficient in discriminating nodules > 1 cm but is not ideal for discriminating cytologically-equivocal nodules.

5.
PLoS One ; 16(1): e0245617, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33449958

RESUMEN

BACKGROUND: Thyroid cancer diagnosis has evolved to include computer-aided diagnosis (CAD) approaches to overcome the limitations of human ultrasound feature assessment. This study aimed to evaluate the diagnostic performance of a CAD system in thyroid nodule differentiation using varied settings. METHODS: Ultrasound images of 205 thyroid nodules from 198 patients were analysed in this retrospective study. AmCAD-UT software was used at default settings and 3 adjusted settings to diagnose the nodules. Six risk-stratification systems in the software were used to classify the thyroid nodules: The American Thyroid Association (ATA), American College of Radiology Thyroid Imaging, Reporting, and Data System (ACR-TIRADS), British Thyroid Association (BTA), European Union (EU-TIRADS), Kwak (2011) and the Korean Society of Thyroid Radiology (KSThR). The diagnostic performance of CAD was determined relative to the histopathology and/or cytology diagnosis of each nodule. RESULTS: At the default setting, EU-TIRADS yielded the highest sensitivity, 82.6% and lowest specificity, 42.1% while the ATA-TIRADS yielded the highest specificity, 66.4%. Kwak had the highest AUROC (0.74) which was comparable to that of ACR, ATA, and KSThR TIRADS (0.72, 0.73, and 0.70 respectively). At a hyperechoic foci setting of 3.5 with other settings at median values; ATA had the best-balanced sensitivity, specificity and good AUROC (70.4%; 67.3% and 0.71 respectively). CONCLUSION: The default setting achieved the best diagnostic performance with all TIRADS and was best for maximizing the sensitivity of EU-TIRADS. Adjusting the settings by only reducing the sensitivity to echogenic foci may be most helpful for improving specificity with minimal change in sensitivity.


Asunto(s)
Diagnóstico por Computador , Procesamiento de Imagen Asistido por Computador , Programas Informáticos , Nódulo Tiroideo/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Ultrasonografía
6.
Life (Basel) ; 11(11)2021 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-34833024

RESUMEN

The value of computer-aided diagnosis (CAD) and computer-assisted techniques equipped with different TIRADS remains ambiguous. Parallel diagnosis performances of computer-assisted subjective assessments and CAD were compared based on AACE, ATA, EU, and KSThR TIRADS. CAD software computed the diagnosis of 162 thyroid nodule sonograms. Two raters (R1 and R2) independently rated the sonographic features of the nodules using an online risk calculator while blinded to pathology results. Diagnostic efficiency measures were calculated based on the final pathology results. R1 had higher diagnostic performance outcomes than CAD with similarities between KSThR (SEN: 90.3% vs. 83.9%, p = 0.57; SPEC: 46% vs. 51%, p = 0.21; AUROC: 0.76 vs. 0.67, p = 0.02), and EU (SEN: 85.5% vs. 79%, p = 0.82; SPEC: 62% vs. 55%, p = 0.27; AUROC: 0.74 vs. 0.67, p = 0.06). Similarly, R2 had higher AUROC and specificity but lower sensitivity than CAD (KSThR-AUROC: 0.74 vs. 0.67, p = 0.13; SPEC: 61% vs. 46%, p = 0.02 and SEN: 75.8% vs. 83.9%, p = 0.31, and EU-AUROC: 0.69 vs. 0.67, p = 0.57, SPEC: 64% vs. 55%, p = 0.19, and SEN: 71% vs. 79%, p = 0.51, respectively). CAD had higher sensitivity but lower specificity than both R1 and R2 with AACE for 114 specified nodules (SEN: 92.5% vs. 88.7%, p = 0.50; 92.5% vs. 79.3%, p = 0.02, and SPEC: 26.2% vs. 54.1%, p = 0.001; 26.2% vs. 62.3%, p < 0.001, respectively). All diagnostic performance outcomes were comparable for ATA with 96 specified nodules. Computer-assisted subjective interpretation using KSThR is more ideal for ruling out papillary thyroid carcinomas than CAD. Future larger multi-center and multi-rater prospective studies with a diverse representation of thyroid cancers are necessary to validate these findings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA