Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Heart Rhythm ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39032523

RESUMEN

BACKGROUND: Short-term antithrombotic therapy is recommended after left atrial appendage occlusion(LAAO) to reduce the risk of device-related thrombosis(DRT). However, patients referred for LAAO have excess bleeding risk. Yet, short-term bleeding events post-LAAO are not well characterized. OBJECTIVE: We aimed to evaluate the incidence of early bleeding post-LAAO and its association with long-term mortality risk. We also sought to identify predictors of early bleeding. METHODS: Patients who underwent LAAO at Mayo Clinic between 2018 and 2023 were included. Early bleeding was defined as bleeding that occurred within three months of discharge. A multivariable Cox proportional hazards model was used to assess the association between early bleeding and death and to estimate the hazard ratio(HR). Multivariable regression analysis was used to identify predictors of early bleeding. RESULTS: Among the 592 patients included, 389(66%) were male, and mean age was 75.6 years. Eighty-three patients(14.0%) experienced early bleeding, with the majority having minimal(63.4%) or minor(17.3%) bleeding. At a median follow-up of 14.4 months(IQR 4.2-27.9), early bleeding after LAAO was associated with an increased risk of all-cause mortality (adjustedHR, 2.07; 95%CI, 1.15-3.75; P=0.02). A history of intracranial bleeding, non-paroxysmal atrial fibrillation, CHA2DS2VASc score, and early DRT were independent predictors of early bleeding. Anti-thrombotic therapy on discharge was not associated with early non-procedural bleeding. CONCLUSIONS: One in seven patients experience a non-procedural bleeding event within 90 days after LAAO. Early bleeding after LAAO is associated with a higher all-cause mortality during mid-term follow-up. Further studies are needed to optimize the management of patients undergoing LAAO.

2.
J Am Heart Assoc ; 13(4): e032963, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38348804

RESUMEN

BACKGROUND: Acute ischemic stroke complicates 2% to 3% of transcatheter aortic valve replacements (TAVRs). This study aimed to identify the aortic anatomic correlates in patients after TAVR stroke. METHODS AND RESULTS: This is a single-center, retrospective study of patients who underwent TAVR at the Mayo Clinic between 2012 and 2022. The aortic arch morphology was determined via a manual review of the pre-TAVR computed tomography images. An "a priori" approach was used to select the covariates for the following: (1) the logistic regression model assessing the association between a bovine arch and periprocedural stroke (defined as stroke within 7 days after TAVR); and (2) the Cox proportional hazards regression model assessing the association between a bovine arch and long-term stroke after TAVR. A total of 2775 patients were included (59.6% men; 97.8% White race; mean±SD age, 79.3±8.4 years), of whom 495 (17.8%) had a bovine arch morphology. Fifty-seven patients (1.7%) experienced a periprocedural stroke. The incidence of acute stroke was significantly higher among patients with a bovine arch compared with those with a nonbovine arch (3.6% versus 1.7%; P=0.01). After adjustment, a bovine arch was independently associated with increased periprocedural strokes (adjusted odds ratio, 2.16 [95% CI, 1.22-3.83]). At a median follow-up of 2.7 years, the overall incidence of post-TAVR stroke was 6.0% and was significantly higher in patients with a bovine arch even after adjusting for potential confounders (10.5% versus 5.0%; adjusted hazard ratio, 2.11 [95% CI, 1.51-2.93]; P<0.001). CONCLUSIONS: A bovine arch anatomy is associated with a significantly higher risk of periprocedural and long-term stroke after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular Isquémico/cirugía , Resultado del Tratamiento , Factores de Riesgo , Accidente Cerebrovascular/etiología
3.
Heart Rhythm ; 21(7): 1024-1031, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38365125

RESUMEN

BACKGROUND: The hemodynamic effects of transcatheter left atrial appendage occlusion (LAAO) remain unclear. OBJECTIVE: We sought to assess the effect of LAAO on invasive hemodynamics and their correlation with clinical outcomes. METHODS: We recorded mean left atrial pressure (mLAP) before and after device deployment. We assessed the prevalence and predictors of mLAP increase after deployment, the association between significant mLAP increase after deployment and 45-day peridevice leak (PDL), and the association between mLAP increase and heart failure (HF) hospitalization. A significant mLAP increase was defined as one equal to or greater than the mean percentage increase in mLAP after deployment (≥28%). RESULTS: We included 302 patients (36.4% female; mean age, 75.8 ± 9.5 years). After deployment, mLAP increased in 48% of patients, 38% of whom experienced significant mLAP increase. Independent predictors of mLAP increase were baseline mLAP ≤14 mm Hg, nonparoxysmal atrial fibrillation, and age per 5 years (odds ratios: 3.66 [95% CI, 2.21-6.05], 1.81 [95% CI, 1.08-3.02], and 0.85 [95% CI, 0.73-0.99], respectively). Significant mLAP increase was an independent predictor of 45-day PDL (odds ratio, 2.55; 95% CI, 1.04-6.26). There was no association between mLAP increase and HF hospitalization. CONCLUSION: After deployment, mLAP acutely rises in 48% of patients, although this is not associated with increased HF hospitalizations. PDL is more likely to develop at 45 days in patients with significant increase in mLAP after deployment, although most leaks were small (<5 mm). These findings suggest that mLAP increase after deployment is not associated with major safety concerns. Additional studies are warranted to explore the long-term hemodynamic effects of LAAO.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Presión Atrial , Cateterismo Cardíaco , Hemodinámica , Humanos , Femenino , Apéndice Atrial/fisiopatología , Apéndice Atrial/cirugía , Masculino , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/terapia , Cateterismo Cardíaco/métodos , Presión Atrial/fisiología , Hemodinámica/fisiología , Dispositivo Oclusor Septal , Estudios Retrospectivos , Función del Atrio Izquierdo/fisiología , Estudios de Seguimiento , Ecocardiografía Transesofágica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA